1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 b a a b b d c d c a b c b c a c b a a B B A B c a c C B d a c b d d d b a a b d c c b b b b c b 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 a a d d b a d c a b a a d a d b a c b c b c a c b b a c a b d a c A B D C c a b a c c c c d c b d b

POWER PLANT FAMILIARISATION-EXAMINATION


NOTE: 1) Please do not write any thing on the question paper 2) Mark answer on the answer sheet only

MM-100

Pressure Limit for Natural Circulation is a. 140 ksc c. 200 ksc

b.175 ksc d. None of the above

Ratio of weight of water entering through downcomers to the weight of steam going outside the drum is called a. Circulation Ratio b. Pressure ratio c. Efficiency of Boiler d. None of the above

Which type of heat is absorbed in water walls a. Latent Heat c. Both a & b

b. sensible heat d. None of the above

A decrease in drum level can cause a. Problem in separation of water & steam c. Both a & b

b. Overheating of Water wall tubes. d. None of the above

What is the range of Circulation ratio for Control Circulation system a. 1-4 c. 3-5

b. 6-9 d. None of the above

Effect of reheat.. a.Work O/P increases c.Wetness of exhaust steam decrease.

b.Heat I/P increases d.all of them

Parameters control by Desuperheater are. a.Pressure& Temperature c.Only Temperature

b.Wetness of steam d.all of them

Heat transfer in Pandant Platen SH by.. a.convection c.conduction

b.Radiation d. Both a&b

10 Ratio of Primary air to Secondary air is.. a.1:4 c.1:6

b.1:5 d.1:7

11 Desinged prssure.& temperature.. of boiler drum in 210MW. a.174kgf/cm2& 450c b.174kgf/cm2& 540c c.140kgf/cm2& 350c d. None of the above

12 Temperature rise of feed water across the economiser is... a. 50c~75c c. 150c~175

b. 100c~125 d. 200c~225

13 which of the following type of turbine does not come under the classification of principle of action of steam a. impulse turbines b. radial reaction turbines c. back pressure turbines d. axial turbines

14 location of turbine thrust bearing is a.Front pedestral c. between I.P and L.P

b. Between H.P and I.P d. L.P turbine rear

15 satellite strips in last 2 rows of LP turbine is provide to a. to adjust frequency of blades

b. to prevent thrust

c. to prevent wet erosion

d. to avoid deformation

16 the steam extraction from seal steam at outlet of HP turbine is sent to a. CRH c. LP heaters

b. HP heaters d. deaerator

17 Factor not to be looked at while locating a power plant a. Geology c. Technology

b. Transport d. Environment

18 Primary air temperature control is done by a. circulating water c. Hydrogen cooling

b. Atm air d. None of the above

19 Reheating necessarily increases a. Work output c. both

b. efficiency d. None of the above

20 In once-through boiler, circulating water for condensation required per 100MW is a. 20,000 m3 hr b. 40,000 m3 hr c. 80,000 m3 hr d. None of the above

21

The thin core laminations vibrate at twice the power frequency when transformer is live. This phenomena is called a. Induction effect b. Magnetostriction c. Thermo-syphon action d. None of the above

22

Which of the following statements is not true in case of 3 phase induction motor a. This motor has squirrel cage type rotor or wound rotor b. This motor rotates at synchronous speed c. A rotating magnetic field is produced in this motor d. All are true

23

In step down transformer, a. N1 > N2 c. N1 = N2 (Where N1= Primary winding turns, N2= Secondary winding turns)

b. N2 > N1 d. None of the above

24

During DOL starting, motor can take current up to a. 2 times c. 15 times

b. 6 times d. None of the above

25 Load break switches make or break circuits at a. 2 x rated current c. 8 x rated current

b. 4 x rated current d. 16 x rated current

26 Which gases are formed when arc decomposes the oil in oil circuit breaker ? a. H2 and C2H2 b. CO2 and CO c. SF6 d. N2

27 In SF6, principle of current interruption is similar to that of a. Bulk oil circuit breaker c. Air blast circuit breaker

b. Minimum oil circuit breaker d. none of the above

28 Breaker should not close unless field breaker is closed to . a. avoid a spurious tripping c. avoid motoring of generator

b. facilitate the restoration of supply d. avoid back feeding of breaker

29 The interconnection between service air and instrument air header is provided at the inlet of drying unit to a. Ensure proper mixing of compressed air b. Equalize the pressure in both the systems c. Provide an emergency provision to meet requirement of instrument air in case prevent any leakage of air. d.

30 For cooling air in service air compressor intercooler is provived a. just before the first stage

b. in between first and second stage

c. after second stage

d. no need of intercoolers

31 The Bulb plus bore above the mercury, in a Mercury Thermometer( a Liquid in Glass Thermometer) is filled with : a Nitrogen and Argon b. Nitrogen and Helium c.Nitrogen and Neon d. Nitrogen and Carbon Dioxide

32

To measure liquid level in small tanks and congested areas: a. Float Operated Dial c.Mercury Manometer

b. Bourden Pressure Gauge d. Diaphragm Type

33 Combination Meters are used for measuring widely fluctuation flows. What is the range for Combination Meters? a. 60 to 40,000 gallons per hour b. 100 to 60,000 gallons per hour c. 45 to 40,000 gallons per hour d. 45 to 60,000 gallons per hour.

34 In "Bellows Flowmeter", the differential pressure produced by primary element is measured as: a. E.M.F b. Displacement c. Capacitance d. height

35 In a closed circulating water cooling system the velocity of water in the RCC duct should range within ft/sec a 5-6 b 4-6 c 3-6 d 3-8

36 Of the total amount of ash produced in the boiler the percentage of fly ash may be of the order of a 20 b 40 c 60 d 80

37 The main type of hoppers used in power stations are a steam filter hoppers c ETP hoppers

b spray cooled ash hopper d none

38 The bearings of ID fans are A. Self aligning ball C. Thrust Cylinder roller 39 PA fans flow can be adjusted by A.inlet guide vane control C. Damper regulation 40 Spool piece is provided in A. SAPH C.LPH 41 For given fan size , system resistance and fluid density ,ratio of pressures A. Is equal to ratio rpm1/rpm2 C. Is equal to (rpm1/rpm2)3 42 Which is not an Idler A. return idler C. troughing idler 43 What is the capacity of crusher? A. 500 tons/hr C. 600 tons/hr 44 Capacity of stacker claimer is A. 300 tons/hr C. 200 tones/hr 45 Conveyor belt speed in stage 1 at kahalgaon is B. 400 tons/hr D. 350 tons/hr B. 700 tons/hr D. 400 tones/hr B. return trainer D. impact trainer B.Is equal to (rpm1/rpm2)2 D. Is equal to (rpm1/rpm2)4 B. SCAPH D. HPH B.Variable Speed control D. Variable pitch control B. Self aligning roller D. Thrust Spherical roller

A. 4.5 m/sec D. 3 m/sec 46 Speed of medium speed mill in rev/min is: a 20-30 c 100-200

B. 3.5 m/sec C. 2.5 m/sec

b 30-100 d 100-150

47 Total number of oil burners in a furnace is: a 11 c 13

b 12 d 14

48 Number of nozzles in a wind box meant for air are a 6 c 8

b 7 d 9

49 rate of wear is highest in ______ speed mill a low c high

b medium d none of these

50 what is the pressure and temperature for HRH? a. 19 KSC & 535 C b. 60 KSC & 340 C

b. 25.6 KSC & 535 C d. 50 KSC & 440 C

51

Heating of main steam (MS) during turbine start up is from .? a. 140/6 PRDS c. 140/7 PRDS

b. 140/29 PRDS d. 140/14 PRDS

52

Parameter for single element control is? a. Drum level c. steam flow

b. feed water flow d. none of the above

53 Hydrogen seal oil pressure should be more than ? a. 10 Kg/cm b. 3 Kg/cm

b. 2 Kg/cm d. 4.8 Kg/cm

54 Rated terminal voltage in 210 MW is ..... KV & in 500 MW is ..KV a. 21.00 ; 50.00 b. 6.25 ; 11.75 c. 132 ; 400 d.15.75 ; 21.00

55 Combined cycle run on ..&..cycles a. Rankine & Reverse Rankine c. Rankine & Carnot

b. Rankine & Brayton d. none of the above

56 In unifired combined cycle ..is/are used to produce steam a. only gas b. both gas and coal c.only coal d. none of the above

57 Combined cycle outputat designed condition (MW) under based load in Anta is .. ; in Auraiya is . a. 89.25 MW ; 111.76 MW b. same in both c. 210 MW ; 500 MW d. 413.3 MW ; 652.56 MW

58 Shaft vibration is measured with a. Hall probe c. Proximity Probes

b. Trib bolts d. None of the above

59 In the rotor, Where Trip Bolts can be found? a. Near JB-1 c. In the thrust bearing

b. Between IPT and LPT d. None of the above

60 High temperature can be measured using a. RTD in bridge circuit c. A and B

b. Thermocouple d. None of the above

61 CVSM used for Turbine overspeed trip stands for a. Control vulve servo meter c. Control variable state machine

b. Control vulve servo motor d. Control vulve speed management

62 Expand ATRS a. Automatic Turbine Run Up System c. Automatic Thrust Run System

b. A Thrust Regulating Station d. Automatic Trial Run System

63 SWAS is used for.. a.Assis twater Treatment c. To avoid corrosion

b. To avoid deposits in Heat exchanger tube d. all a,b & c

64 Expand OLCS a.Open Loop Control System c.Oil Lubrication Control System

b.Oil Leakage Control System d.None of the above

65 Function of MMIPIS are.. a.Sequence & modulating controls c.all Plant operation including Emergency condition

b.Plant start up/shut down d.All of the above

66

What does PLCC stand for: a. Power Line Control Circuit c. Power Loss in Control Circuit

b. Power Line Carrier Communication d. Programmable Logic Control Circuit

67

Choice of circuit breaker is limited by: a. load current and fault MVA. c. both a and b.

b. type of fault. d. none of these.

68

Commonly used Voltage level for communication is ____. a. 220V c. 48V

b. 11KV d. 415V

69 Which of the following is part of station auxiliary: a. ID fan. c. boiler feed pump.

b. lighting system. d. coal mills.

70 Which is not the turbine lub oil system ? a. main oil pump (MOP) c. feeder oil pump (FOP)

b. starting oil pump (SOP) d. jacking oil pump (JOP)

71 Arrange the correct sequence of condensate flow through 1) CEP, 2) hot well , 3) deaerator, 4) BFP: ________________ a. 1-2-3-4 b. 2-1-3-4 c. 2-1-4-3 d. 1-2-4-3

72 Which factor primarily accelerate the efficiency of deaerator? a. increased contact time c. both a and b

b. scrubbing of condensate d. none of these

73 HP heaters of the same unit are connected in which of the following fashion? a. series b. parallel c. independent d. both a and b

74 Which of the following is/are the parts of boiler structure a. Supporting structure c. both a & b

b. Gallaries & stair ways d. None of the above

75 In a 210 MW H.P. unit, the outlet temperature & pressure of the steam coming out from the superheater is a.480oC & 157 Kg/cm2 b. 540oC & 157 Kg/cm2 c. 540oC & 126 Kg/cm2 d. None of the above

76 Corrosions and fouling prevails in air Preheater in _________conditions thus they (tubes) are made _______in size (under preceding a. hotter, shorter b. colder, shorter c. hotter, longer d. none of these

77 8. In ESP the collecting plates are made like _________ and discharge plates are made like ________. a. Steel plates, thin wires b. Thin wires, steel plates c. Both steel plates d. Cup cone shape.

78

In reference to FSSS, the logic systems are designed to operate on a. AC supply only c. AC and DC both

b. DC supply only d. none of these.

79

____________relay are extensively used as retentive memory circuits so as to minimize the power consumption of logic panel a.Latch relay b. Control relay c. Time delay relay d. Any of these.

80

Of the total quantum of coal consumed in the boiler the % of ash may be a.50-60% c.60-70%

b.30-45% d.20-30%

81

In a fly ash system, which of the following doesnt have a flushing apparatus under it a. economiser hopper b. air preheater hopper c. stack hopper d. superheater hopper

82

The capital cost of natural draft CT is about . % more than that of the mechanical draft CT a. 60% b. 40% c. 10% d. 80%

83

AWRS is used for a. service water c. both of them

b. bottom ash and fly ash d. none of the above

84 The combined Journal and Thrust bearing is provided between

a. HP rotor and IP rotor c. Either A or B

b. IP rotor and LP rotor d. Both A and B

85 Let P1 = The pressure of Hydrogen in the rotor, P2 = The pressure of water flowing through the tubes of stator windings , the

a. Positive c. Zero

b. Negative d. Sometimes positive, sometimes negative

86 To make economical use of electrolysis of water, we prepare a solution by adding ______ with pure water

a. Baking Soda c. Table Salt

b. Sulphuric Acid d. Caustic Soda

87 To improve Boiler Efficiency and for better performance of Boiler, we must

a. Send less amount of Coal and more amount of secondary air c. Incorporate number of super heaters

b. Send more amount of Coal and reduce the amount of secondary air d. Both (B) and

88 At what percentage of speed the main oil pump takes over? a. 60% of rated speed c. 90% of rated speed

b. 40% of rated speed d. 80% of rated speed

89 main steam presssure & tamperature at full load comdition in 210 MW unit is a. 147.1 kg/cm^2 & 535'C b. 140.8 kg/cm^2 & 550'C c. 138.2 kg/cm^2 & 510'C d. 150 kg/cm^2 & 570'C a

90 How much degree centigrade rise in cold water temperature in a 200MW unit corresponds to 10mm vacuum loss a 1 b 2 c 3 d 4

91 What is the circulation ratio in once through boiler? a. 1 c 4

b. 3 d 12

92 Orientation of water wall tubes in once through boiler is a. horizontal c. spiral

b. vertical d. none of above

93 Turbine governing systems are employed to perform a) Stable speed c) both of these

b) desired degree of load control d) none of above

94 What extent of overspeeding in turbine speed cant be toletrated?

a) 5-10 % b) 15-20 %
95 Ejector performs the following actions in condenser except? a. air evacuation c. regulates water flow in condenser

b) 10 - 15 % d) 0-5 %

b. non-condensing gases evacuation d. maintain vacuum

96 what is the Approximate % of total ash produces, in Coal fired power plants, is carried along with flue gases a. 40 b.50 c. 60 d.80

97 What is % share of coal in country's primary energy resources? a. 85% c. 95%

b. 70% d. 60%

98 Using reheating, wetness of LP turbine exhaust a. Increases c. Remains same

b. Decreases d. No correlation

99 Thermal cycle efficiency is affected by a. Initial steam pressure c. Regenerative feed water heating

b. Reheating d. All of the above

100 Pressure inside furnace induced by I.D. fan is a. 100 mm of water column c. -50 mm of water column

b. -5 to -10 mm of water column d. 30 to 40 mm of water column

1 Pressure Limit for Natural Circulation is a. 140 ksc c. 200 ksc

b b.175 ksc d. None of the above

2 Ratio of weight of water entering through downcomers to the weight of steam going outside the drum is called a. Circulation Ratio b. Pressure ratio c. Efficiency of Boiler d. None of the above

3 Which type of heat is absorbed in water walls a. Latent Heat c. Both a & b

a b. sensible heat d. None of the above

4 which type of flow occurs in Economiser? a. Counter Flow c. Cross-flow

a b. Parallel Flow d. None of the above

5 A decrease in drum level can cause a. Problem in separation of water & steam c. Both a & b

b b. Overheating of Water wall tubes. d. None of the above

6 An increase in drum level can cause a. Problem in separation of water & steam c. Both a & b

a b. Overheating of Water wall tubes. d. None of the above

7 Point at which density of water because equal to the density of steam is called a. Sub critical Point b. Super critical point c. Critical Point d. None of the above

8 What is the range of Circulation ratio for Control Circulation system b. 6-9 a. 1-4 c. 3-5 d. None of the above

9 The circulation ratio value for Combined circulation system is a. 2 b. 4 c. 6 d. None of the above

10 What is the minimum pressure limit for combined circulation system a. 140 ksc b. 175 ksc c. 225 ksc d. 200 ksc

11 Total no. of Boiler drums used in the combined circulation is a. 0 b. 1 c. 2 d. 3

12 Controlled circulation system is used upto which point a. Sub critical Point b. Super critical point c. Critical Point d. None of the above

13 6 degree rise in temp. of feed water by economiser cause a. 1% increase in boiler efficiency b. 1% saving in fuel consumption c. 1% increase in plant efficiency d. None of the above

14 22 degree reduction in flue gas temp cause a. 1% increase in boiler efficiency c. 1% increase in plant efficiency

a b. 1% saving in fuel consumption d. None of the above

15 what is the value of design pressure for 500 MW Boiler drum a. 140 ksc b. 175 ksc c. 225 ksc d. 204 ksc

16 Number of downcomers for 500 MW unit is a. 3 c. 0

b b. 6 d. None of the above

17 .. % of heat of combustion of fuel in furnace is absorbed by water walls b. 50% a. 30% c. 20% d. None of the above

18 Envelope of thin steel casing over water wall tubes providing seal against furnace leakage is called a. Skin Casing b. Membrane c. Outer wall d. None of the above

19 Number of CC Pumps for 500 MW unit is a. 3 c. 0

a b. 6 d. None of the above

20 What is the position of an economiser in boiler a. Horizontal c. Inclined

a b. Vertical d. None of the above

21 What is the prefered temperature control by Desuperheater? a.Above 540C b. Above 450C

c.Below 500C d. None of the above

22 Effect of reheat.. a.Work O/P increases c.Wetness of exhaust steam decrease.

d b.Heat I/P increases d.all of them

23 Parameters control by Desuperheater are. a.Pressure& Temperature c.Only Temperature

c b.Wetness of steam d.all of them

24 Pressure of inlet steam of HPT can be increase with maximum allowable Wetness of exhaust steam by a.Reheating b.Superheating c.Atemperature d. None of the above

25 1.Steam temperature drop as steam flow increases in Radiant superheater 2.Steam temperature increases as as steam flow increase in convective SH 3.Steam temperature increases as as steam flow increase in Radiant SH 4.Steam temperature drop as steam flow increase in con Select the FALSE statement a.1&2 b.3&4 c.2&4 d.1&4 26 Main steam has valve. a.1 b.2 c.3 d.4

27 Functions of using superheater in boiler is a.Controlled Pressure b.Controlled Temperature c.controlled Wetness e. b&c d.all of them

28 No. of stages of SH attemperature in boiler aregenerally. a.1 b.2 c.0 d.3

29 Heat transfer in Pandant Platen SH by.. a.convection b.Radiation c.conduction d. Both a&b

30 Ratio of Primary air to Secondary air is.. a.1:4 c.1:6

c b.1:5 d.1:7

31 Heat gain in SH is..of total heat gain in cycle. a.20% c.25%

b b.30% d.35%

32 Desinged prssure.& temperature.. of boiler drum in 210MW. a.174kgf/cm2& 450c b.174kgf/cm2& 540c c.140kgf/cm2& 350c d. None of the above

33 Heat gain in Reheter is ..% of total gain in cycle. a.10 b.20 c.18 d.14

34 For every 20C fall in temperature of fluegas across the air preheater cause..% increase in boiler efficiency. b.1 a.3 c.2 d.4

35 Temperature of air at outlet of APH is approximately isC. a.360~370 b.300~320 c.270~280 d. None of the above

36 No. of air preheater used in a boiler are. a.1 c.2

c b.4 d.3

37 Gross Calorific value of coal used in indian power plant approx. a.3000kcal/kg b.3500kcal/kg c.2000kcal/kg d.2700kcal/kg

38 Temperature rise of feed water across the economiser is... a. 50c~75c b. 100c~125 c. 150c~175 d. 200c~225

39 No. of Reheater attemperature stage used in boiler are. a.3 b.2 c.4 d.1

40 Flow..and Temperature.in Reheater. a.569 tons/hr & 450c c.569 tons/hr & 540c

c b.669 tons/hr & 450c d.669 tons/hr& 540c

41 what happens when jet enters the locked turbine blade a. maximum force with zero work done b. minimum force with work output c. maximum work output with zero force d. None of the above

42 Neglecting any frictional losses , at what blade speed the work done is maximum? a. blade speed equal to steam inlet speed b. blade speed twice of steam inlet speed c. blade speed half of steam inlet speed d. None of the above

43 which of the following type of turbine does not come under the classification of principle of action of steam a. impulse turbines b. radial reaction turbines c. back pressure turbines d. axial turbines

44 the emergency valves in turbines are provided in a. MS line b. HRH line c. CRH line d. none of the above

45 The IV valves in turbines are located in a. MS line c. HRH line

b b. CRH line d. None of the above

46 the coupling between HPT and IPT is of ..type a. rigid c. semiflexible

a b. flexible d. None of the above

47 the number of bearings in turbine are a. 5 c. 7

c b. 6 d. 8

48 location of turbine thrust bearing is a.Front pedestral c. between I.P and L.P

b b. Between H.P and I.P d. L.P turbine rear

49 the location of main oil pump is a.Front pedestral c. between I.P and L.P

a b. Between H.P and I.P d. L.P turbine rear

50 the axial expansion of H.P turbine inner casing takes about a fixed point . That point is a. HP outlet b. IP inlet c. Front pedestral bearing d. HP inlet

51 which root arrangement of turbine bladings are used for longer blades ? b. fir tree a. T roots c. fork and pin root d. b&c

52 In which of the following turbines shrouding is provided in all stages b. IPT a. HPT c. LPT d. HP and LP TURBINES

53 satellite strips in last 2 rows of LP turbine is provide to a. to adjust frequency of blades b. to prevent thrust c. to prevent wet erosion d. to avoid deformation

54 the inlet pressure of the steam supplied to sealing chamber is around b. 1.03-1.05 ksc abs a. 1.15-1.18 ksc abs c. 1.15-1.18 ksc guage d. 1.03-1.05 ksc guage

55 the barring gear is driven by a. MOP c.JOP

b b. AOP d. EOP

56 T rootsare used for which type of blades a. short blades c. long blades shrunk on disc type rotor

a b. long blades d. a&b

57 in HP rotors balancing holes are machined for minimising a. axial thrust b. axial expansion c. radial thrust d. differential exansion

58 the steam extraction from seal steam at outlet of HP turbine is sent to a. CRH b. HP heaters c. LP heaters d. deaerator

59 the governing system in 210/200 MW predominantly is of type b. nozzle a. throttle c. by pass d. none

60 Barring gear is located at a. front pedestral c.LP rear

c b. between IP and LP d. none

61 The make-up water as % of water required for steam cycle a. 2-3% b. 4-5% c. 6-8% d. None of the above

62 Share of coal in total cost of power generation a. 25-30% c. 50-60%

c b. 70-75% d. None of the above

63 Factor not to be looked at while locating a power plant a. Geology b. Transport c. Technology d. Environment

64 What is % share of coal in country's primary energy resources? a. 85% b. 70% c. 95% d. 60%

65 Daily coal requirement of 500 MW power plant in full load condition is a. 3000 tons b. 6000 tons c. 4500 tons d. 8000 tons

66 Using reheating, wetness of LP turbine exhaust a. Increases c. Remains same

b b. Decreases d. No correlation

67 Thermal cycle efficiency is affected by a. Initial steam pressure c. Regenerative feed water heating

d b. Reheating d. All of the above

68 Primary air temperature control is done by a. circulating water c. Hydrogen cooling

b b. Atm air d. None of the above

69 Pressure inside furnace induced by I.D. fan is a. 100 mm of water column c. -50 mm of water column

b b. -5 to -10 mm of water column d. 30 to 40 mm of water column

70 The type of steam flow in LP turbine is a. single flow c. double flow

c b. mixed flow d. cross flow

71 The superheated temperature of steam is a. 540C c. 500C b. 360C d. 450C

72 Steel rollers in coal mills are rotated by a. motor c. hydraulics

d b. pneumatic valves d. None of the above

73 Reheating necessarily increases a. Work output c. both

a b. efficiency d. None of the above

74 Fly ash produced for each 100 MW a. 100 tons c. 800 tons

b b. 400 tons d. 650 tons

75 Furnace oil required for 500 MW power station at full load a. 75 K.L. b. 120 K.L. c. 30 K.L. d. None of the above

76 Make-up water as % of water in cooling cycle a. 3% c. 5%

a b. 1% d. 4%

77 Air preheaters are used to heat a. Primary air c. both

c b. secondary air d. None of the above

78 ESP is used to remove a. bottom ash c. both

b b. fly ash d. None of the above

79 In once-through boiler, circulating water for condensation required per 100MW is a. 20,000 m3 hr b. 40,000 m3 hr c. 80,000 m3 hr d. None of the above

80 Coal reserves in India are a. 100 billion tons c. 160 billion tons

d b. 180 billion tons d. 130 billion tons

81 What is the benefit of stepping up the generated voltge by Generator Transformer(GT) a. Copper losses are reduced. a. Size of conductor is reduced.

c. Both (a) and (b)

d. None of the above

82 Which of the following relation is correct in case of transformer a. V1/V2=I1/I2=N1/N2 b. V2/V1=I1/I2=N1/N2 c. V1/V2=I1/I2=N2/N1 d. V1/V2=I2/I1=N1/N2

83 In primary and secodary side of a step up transformer, which of the following parameter does not change a. Voltage b. Current c. Frequency d. None of the above

84 The thin core laminations vibrate at twice the power frequency when transformer is live. This phenomena is called a. Induction effect b. Magnetostriction c. Thermo-syphon action d. None of the above

85 Oil Temperature Indicators are used to measure a. Bottom oil temperature c. Middle oill temperature

B b. Top oil temperature d. None of the above

86 UAT means a. Unit Advanced Transformer c. Universal Auxiliary Transformer

D b. Universal Advanced Transformer d. Unit Auxiliary Transformer

87 Station transformer is required a. To feed power from generator to grid c. To feed power to auxiliaries during start-up

C b. To feed power to auxiliariess when plant is running d. None of the above

88 Rotating magnetic field in 3 phase Induction motor rotates with the speed a. (120 X Supply frequency )/Pairs of poles b. (60 X Supply frequency )/Pairs of poles c. (120 X Pairs of Poles )/supply frequency d. None of the above

89 Which of the following statements is not true in case of 3 phase induction motor a. This motor has squirrel cage type rotor or wound rotor This motor rotates at synchronous speed b. c. A rotating magnetic field is produced in this motor d. All are true

90 At what load, efficiency of 3 phase induction motor is more a. Full Load b. No load c. Efficiancy remains same at all loads d. Efficiancy cannot be predicted

91 The EMF induced in the primary winding of transformer is given by a. 1.11 f.N1. m b. 4.44 f.N1. m c. 4.44 f.N2. m d. None of the above

92 The maximum voltage dip which can be permitted on starting of largest motor is normally limited to a. 1% to 5% b. 15% to 20% c. 30% to 35% d. None of the above

93 Heat is not generated in the transformer due to a. Copper losses c. Friction Losses

C b. Iron Losses d. None of the above

94 In step down transformer, a. N1 > N2

A b. N2 > N1

c. N1 = N2 d. None of the above (Where N1= Primary winding turns, N2= Secondary winding turns) 95 Which of the following motor is not a self starting motor a. 3 phase Induction Motor b. 3 phase Synchronous motor c. Both are self starting motors d. None of the above B

96 Rotor winding (field winding) is excited by DC supply in case of a. Synchronous Motor b. Induction Motor c. Both are excited by DC supply d. None of the above

97 DOL starting of motors is a. Direct-On-Load c. Direct-On-Line

C b. Direct-Off-Load d. None of the above

98 In star-delta staring of a motor, torque is reduced to a. 33% c. 80%

A b. 59% d. None of the above

99 During DOL starting, motor can take current up to a. 2 times c. 15 times

B b. 6 times d. None of the above

100 Which motor rotates exactly at speed 120f/ P.(where P=No. of poles, f= Supply frequency) a. Synchronous Motor b. Induction Motor c. DC Motor d. None of the above

101 Which of the following does not fall in the category of switchgear ? a. Load break switches b. Isolators c. Relay d. Earth switches

102 An isolator can break an electric circuit when the circuit is to be switched on a. No load b. Half load c. Full load d. Any load

103 Which of the following switchgear make or break circuit on fault ? a. Load break switches b. Isolators c. Circuit breakers d. Earth switches

104 Load break switches make or break circuits at a. 2 x rated current b. 4 x rated current c. 8 x rated current d. 16 x rated current

105 How many insulators post are there in rotating centre post type isolator in each phase ? a. 1 b. 2 c. 3 d. 4

106 Which of the following medium is not used for arc quenching ? a. Oil b. Air c. SF 6 d. Water

107 Fixed trip type circuit breaker shall trip only when the closing operation is .. a. started b. running c. completed d. not started

108 Circuit breaker make and break the current with the help of a. interrupters b. tension rod c. bakelized papers d. insulators

109 Which gases are formed when arc decomposes the oil in oil circuit breaker ? a. H2 and C2H2 b. CO2 and CO c. SF 6 d. N2

110 Which property of hydrogen assist in cooling of arc in oil circuit breaker? a. Light weight b. Less melting point c. Less boiling point d. High thermal conductivity

111 The di-electric strength build up in oil circuit break increases with a. increase in temperature b. increase in fault current c. increase in system voltage d. all of the above

112 The no. of porcelain insulators in air blast breakers is determined by the a. system voltage b. current c. temperature d. none of the above

113 Which circuit breaker has the excellent performance under faulty condition ? a. Bulk oil circuit breaker b. Minimum oil circuit breaker c. Air blast circuit breaker d. SF6 circuit breaker

114 In SF6, principle of current interruption is similar to that of a. Bulk oil circuit breaker b. Minimum oil circuit breaker c. Air blast circuit breaker d. none of the above

115 SF6 gas is heavier than air by ..... a. five times c. seven times

a b. twice d. ten times

116 Di-electric strength of SF6 gas in comparison to air is . a. five times b. twice c. seven times d. ten times

117 Which side of the transformer should trip when breaker installed on the HV side trips ? a. LV side b. HV side c. Both side d. Any side

118 Breaker should not close unless contacts of Master trip relay are reset, to a. avoid a spurious tripping b. facilitate the restoration of supply c. avoid motoring of generator d. avoid back feeding of breaker

119 Breaker should not close unless field breaker is closed to . a. avoid a spurious tripping b. facilitate the restoration of supply c. avoid motoring of generator d. avoid back feeding of breaker

120 LV side breaker of the transformer should not close unless HV side breaker is closed to a. avoid a spurious tripping b. facilitate the restoration of supply c. avoid motoring of generator d. avoid back feeding of breaker

121 which of the following are the type of compressed air systems used in thermal powre station? a. Instrument air system b Station air system c. Both a & b d. None of the above

122 Which of the following air system is used for operating dampers, diaphragm vavles etc. a. Instrument air system b Station air system c. Both a & b d. None of the above

123 Which of the following air compresser system is used for light oil atomisation, cleaning filters and maintenance work a. Instrument air system b Station air system c. Both a & b d. None of the above

124 The interconnection between service air and instrument air header is provided at the inlet of drying unit to a. Ensure proper mixing of compressed air b. Equalize the pressure in both the systems c. Provide an emergency provision to meet requirementd. prevent any leakage of air. o

125 The control air compressors have been installed for supplying a. High moisture air to instruments b. low moisture air to instruments. c.moisture free dry air to instruments d. moisture free air for cleaning of filters.

126 Instrument air compressor is a. single stage centrifugal type c.Single stage reciprocating type

D b. Double stage centrifugal type d. Double stage reciprocating type

127 The absorption tower of Air drying unit is filled with a. silica gel & activated charlcoal c. silica gel & activated alumina

C b. activated alumina & activated charcoal d. none of the above

128 service air compressor is a. single stage centrifugal type c.Single stage reciprocating type

D b. Double stage centrifugal type d. Double stage reciprocating type

129 For cooling air in service air compressor intercooler is provived a. just before the first stage b. in between first and second stage c. after second stage d. no need of intercoolers

130 The instrument air compressor is driven by a. Electric motor through v-belt c.Electric motor through gears

A b. Turbine through v- belt d. Turbine through gears

131 Thermostat used with water heater is: a. Bi Metallic Strip Thermometer c. Solid Rod Thermometer

c b. Liquid in Glass Thermometer d. Mercury in Steel Thermometer

132 A Bi-Metallic Strip Thermometer works on the principle of: a. Different coefficients of cubical expansion of two meta Different coefficients of linear expansion of two metal strips. b. c. Different coefficients of superficial expansion of two me Difference in rate of molecular conduction of two metal strips. d.

133 The coefficient of cubical expansion of Mercury is __________ : a. eight times greater that of glass. b. Twelve times greater that of glass c. six times greater that of glass d. Ten times greater that of glass

134 The Bulb plus bore above the mercury, in a Mercury Thermometer( a Liquid in Glass Thermometer) is filled with : a Nitrogen and Argon b. Nitrogen and Helium c.Nitrogen and Neon d. Nitrogen and Carbon Dioxide

135 In a gas thermometer, the temperature is measured in relation to: b. The change in kinetic energy(molecular velocity) of the gas particles when subjected to heat. a. The variation of pressure in the capillary at constant vo c. The rate of change of collisions of gas particles with each other and with the thermometer walls. d.The variation in the volume of the gas at constant pressure.

136 Potentiometer type thermometer works on the principle of: a. Thomson Effect. b. Variation in electrical resistance with variation in temperature. c.Peltier Effect. d. Seeback Effect.

137 The low Pressures in steam condensers are measured by: a. Single tube Manometer b. U- tube manometer c.Bourdon Pressure Gauge d. Kentometer

138 The range of Bourdon Pressure Gauge is: a. 10-60,000 psi c.10- 75,000 psi

b b. 10- 80,000 psi d. 10-65,000 psi

139 To measure liquid level in small tanks and congested areas: a. Float Operated Dial b. Bourden Pressure Gauge c.Mercury Manometer d. Diaphragm Type

140 In Air Purge System, the pressure exerted by liquid is proportional to: a. To the volume of liquid b. To the density of the liquid c. To the depth of the liquid d. To the surface tension of the liquid.

141 The principle measurement/s made by flowmeters is/are: a. Volumetric - Quantity of flow b. Inferential - Rate of flow c. Volumetric and Inferential flow of fluid + viscosifty of flu Only Volumetric and Inferential flow. d.

142 For measuring the large flows with the minimum of pressure drop, what kind of flowmeter should be used? a. Rotating Impeller Type Flowmeter b. Turbine Type Flowmeter c. Helical Vane Type Flowmeter d. Rotating Oscillating Piston Type Flowmeter

143 To measure the flow of Petroleum and Commercial liquids what kind of flowmeter should be used? a. Combination Meters b. Rotating Impeller Type d. Turbine Type d. Helical Vane Type

144 Combination Meters are used for measuring widely fluctuation flows. What is the range for Combination Meters? a. 60 to 40,000 gallons per hour b. 100 to 60,000 gallons per hour c. 45 to 40,000 gallons per hour d. 45 to 60,000 gallons per hour.

145 According to the Bernoulli's theorem, the quantity of fluid or gas flowing is proportional to: a. square root of the differential pressure b. square of the differential pressure c. fourth root of the differential pressure d.directly proportional to the differential pressure.

146 What kind of Primary element is used to measure the flow of dirty fluids? a. Ventury b. Flow Nozzle c. Pilot Tube d.Orifice Plate

147 For a U-tube Manometer: a. The density of liquid in manometer > The density of flu Density of liquid in manometer < Density of fluid b. d. Density of liquid in manometer doesn't play any role in measuring the flow of fluid.

c. Density of liquid = Density of fluid

148 "Bell Type" Flow meter is an example of: a. Variable Aperture type Flowmeter c. Low Differential Head Flowmeter

c b. Electromagnetic Flowmeter d. High Differential Head Flowmeter

149 In "Bellows Flowmeter", the differential pressure produced by primary element is measured as: a. E.M.F b. Displacement c. Capacitance d. height

150 To measure the flow of liquids through the circular pipes, what kind of flowmeter is suitable? a. Bellows Flowmeter b. Low differential head flowmeter c. U-tube Manometer d. Electromagnetic Flowmeter

151 Of the total amount of coal consumed in the boiler the percentage of ash may be of the order of a 25-30 b 30-45 c 35-40 d 32-38

152 Dry and wet bulb temperature detector detects a pressure c humidity

c b temperature d air density

153 Velocity caps used for direct water circulating cooling sysytem, from the ocean, changes the direction of water flow from a horizontal to vertical b vertical to horizontal c both a and b d none of the above

154 In a closed circulating water cooling system the velocity of water in the RCC duct should range within ft/sec a 5-6 b 4-6 c 3-6 d 3-8

155 In a closed circulating lake water cooling system extent of cooling of hot water depends on a ambient temperature b reservoir water temperature c both a and b d none

156 In case of induced draft and forced draft cooling towers the location of fan is at level respectively a ground and top b top and ground c ground and base d top

157 Main drawback of forced draft cooling tower is.... a exit velocity is low c inlet velocity is low

a b exit velocity is high d inlet velocity is high

158 Ash produced by a typical 2000 MW plant is.ton per day a 7000-11000 b 12000-15000 c 9000-12000 d 15000-20000

159 Of the total amount of ash produced in the boiler the percentage of fly ash may be of the order of a 20 b 40 c 60 d 80

160 Fly Ash is collected from a Air heater hopper c ESP hopper.

d b Economiser hopper d all of the above

161 Hydrobackter is a vacuum device to collect a pulverised coal c ash

c b steam d condensate

162 How much degree centigrade rise in cold water temperature in a 200MW unit corresponds to 10mm vacuum loss a 1 b 2 c 3 d 4

163 In fly ash system no of air preheater hoppers are a 2 c 4

c b 40 d 12

164 The main type of hoppers used in power stations are a steam filter hoppers c ETP hoppers

d b spray cooled ash hopper d none

165 In ash water system for BA a high pressure water is required c both a and b

a b low pressure water is required d none

166 Bearing tempratures of air pre heater operation must be within A. 55-65 deg C C. 75-85 deg C B. 65-75 deg C D. 85-95 deg C

167 The basic information needed to select a fan A .air or gas flow - kg/hr C. system resistance (losses) B. Density (function of temprature and pressure) D. all of these

168 In 210 MW ID fans are of type A. Axial impulse C. Radial Forward curved B. Axial reaction D. Radial backward curved

169 The bearings of ID fans are A. Self aligning ball C. Thrust Cylinder roller B. Self aligning roller D. Thrust Spherical roller

170 Signalling Temprature for ID bearing A. 70 deg C C. 80 deg C B. 75 deg C D. 85 deg C

171 Stopping Temprature for ID bearing A. 70 deg C C. 80 deg C B. 90 deg C D. 85 deg C

172 Coupling between the motor and fan in ID fan A. Flexible pin type with rubber bush inserts C. Flange coupling B. Flexible pin type without rubber bush inserts D. Sleeve or muff coupling

173 In 210 MW PA fans are of type A. Axial impulse C. Radial Forward curved B. Axial reaction D. Radial backward curved

174 PA fans flow can be adjusted by A.inlet guide vane control C. Damper regulation B.Variable Speed control D. Variable pitch control

175 In 500 MW PA fans are of type A. Axial impulse C. Radial Forward curved B. Axial reaction D. Radial backward curved

176 In 500 MW ID fans are of type A. Axial impulse C. Radial B. Axial reaction D. none of these

177 For every 20 deg. C drop in flue gas temp efficiency of plant increses by A.1% C. 1.5% B. 2% D. 1.8%

178 Size of spool piece is A. 100mm C. 175mm B. 150mm D. 200mm

179 Spool piece is provided in A. SAPH C.LPH B. SCAPH D. HPH

180 In 500 MW which type air preheater is used A. 2 no of trisector C. 3 no of trisector B. 3 no bisector regenarative D. 2 no bisector

181 Generally ID fan dia is of order A.2500mm C. 1000mm B. 3000mm D. 4000mm

182 Pressure and temprature of Steam used for Soot Blower are respectively A.29 kg/cm2 and 330 deg C C. 29kg/cm2 and 220 deg C B. 31 kg/cm2 and 330 deg C D. 31 kg/cm2 and 220 deg C

183 For given fan size , system resistance and fluid density ,ratio of flow rates A. Is equal to ratio rpm1/rpm2 C. Is equal to (rpm1/rpm2)3 B.Is equal to (rpm1/rpm2)2 D. Is equal to (rpm1/rpm2)4

184 For given fan size , system resistance and fluid density ,ratio of pressures A. Is equal to ratio rpm1/rpm2 C. Is equal to (rpm1/rpm2)3 B.Is equal to (rpm1/rpm2)2 D. Is equal to (rpm1/rpm2)4

185 For given fan size , system resistance and fluid density ,ratio of powers A. Is equal to ratio rpm1/rpm2 C. Is equal to (rpm1/rpm2)3 B.Is equal to (rpm1/rpm2)2 D. Is equal to (rpm1/rpm2)4

186 The technique use for transportation of coal from mines to power station is A. MGR C. MOR B. CGR D. MGC

187 The capacity silo varies between A .3000-3500 ton C. 2000-3000 ton B. 2400-4000 ton D. 4000-5500 ton

188 How many types of Idlers are used in coal handling system A. 2 C. 3 B. 4 D. 5

189 Which is not an Idler A. return idler C. troughing idler B. return trainer D. impact trainer

190 Which is not a part of coal handling system? A. idler C. cooling tower B. crusher D. scrapper

191 how many types of scrappers are generally used in coal handling system? A. 4 C. 2 B. 5 D. 3

192 Crushaer crushes the coal from 200 mm to ----mm. A. 35 C. 25 B. 30 D. 20

193 Vibrating screen sends the coal having size less than 20 mm to A. crusher C. magnetic separator B. bellt feeder d. track hopper

194 What is the capacity of crusher? A. 500 tons/hr C. 600 tons/hr B. 700 tons/hr D. 400 tones/hr

195 Which equipment is used for cutting and lifting coal from the stock yard to belt? A. digging wheel C. idlers B. plough feeder D.trippers

196 how many types of tripper are used in coal handling system? A. 5 C. 4 B.2 D. 3

197 Capacity of vibrating screen is A.200 tons/hr C. 450 tons/hr B. 600 tons/hr D. 400 tons/hr

198 The gross calorific value of indian coal is A. 2700-4300 kcal/kg B. 2000-3000 kcal/kg

C. 3000-5000 kcal/kg 199 Capacity of stacker claimer is A. 300 tons/hr C. 200 tones/hr 200 Plough feeder is normally installed under A. crusher C.skirt board 201 Temperature of fuel oil in storage tank is A.40-50 deg C. 30-55 deg 202 Oil pumps used for fuel oil system are A.reciprocating pump C. axial pump

D. 4000-4500 kcal/kg c B. 400 tons/hr D. 350 tons/hr d B. digging wheel D.hopper b B. 50-70 deg D. 35-45 deg d B. centrifugal pump D. screw pump a

203 Which pump is used to transfer oil from storage tank to service tank ? A. oil transfer pump C. CEP pump 204 Conveyor belt speed in stage 1 at kahalgaon is A. 4.5 m/sec D. 3 m/sec 205 plough feeder speed in stage 1 at kahagaon is A. 10-20 rpm C. 5 - 19 rpm 206 which of the following is not a volumetric feeder a. Chain feeder c Rotary feeder B. 20- 30 rpm D. 2 -13 rpm B. 3.5 m/sec C. 2.5 m/sec B.lub boil pump D. CC pump

d b Belt feeder d. Gravimetric feeder

207 Fineness of coal is reduced so that 70-80% of the coal passes through a. 200 mesh sieve b. 150 mesh sieve c. 300 mesh sieve d 100 mesh sieve

208 Speed of low speed mill in rev/min is: a 17-20 b 25-30

a c 30-35 d 40-45

209 Speed of medium speed mill in rev/min is: a 20-30 c 100-200

b b 30-100 d 100-150

210 Speed of high speed mill in rev/min is: a 500-1000 c 300-400

a b 200-300 d 500-700

211 Most efficient mill used nowadays is: a Low speed mill c high speed mill

d b medium speed mill d Bowl mill

212 which of the following is not a method of fuel firing a Vertical firing c Tangential firing

d b Horizontal firing c Line firing

213 total no of pulverised coal burners in a furnace is: a 21 c 23

d b 22 d 24

214 Total number of oil burners in a furnace is: a 11 c 13

b b 12 d 14

215 oil burners are fed with HFO till the boiler load reaches a 20% b 25% c 30% d 35%

216 Number of nozzles in a wind box is: a 13 c 15

a b 14 d 16

217 Firing system employed in NTPC Kahalgaon is a Tangential firing c horizontal firing

a b vertical firing d mechanical firing

218 Number of nozzles in a wind box meant for coal are a 6 c 8

a b 7 d 9

219 Number of nozzles in a wind box meant for air are a 6 c 8

b b 7 d 9

220 type of oil not used in oil burner is a Heavy fuel oil c LSHS

d b light diesel oil d Heavy Diesel oil

221 which of the following is not a type of oil burner a Air atomised burners c Mechanically atomised burners

d b Steam atomised burners d Electrically atomised burners

222 Availability of ________ speed mill is 100% of boiler availability due to low maintenance a Low b medium c hifgh d none of these

223 _______ speed mill consumes more power per ton of coal a low b medium c high d none of these

224 rate of wear is highest in ______ speed mill a low c high

c b medium d none of these

225 Least power is consumed in ________ speed mills a low c high

c b medium d none of these

226 what is the inlet pressure and temperature for HPC ? a. 130 KSC & 535 C c. 130 KSC & 440 C

a b. 170 KSC & 535 d. 180 KSC & 540 C C

227 what is the pressure and temperature of CRH ? a. 60 KSC & 400 C c. 28.7 KSC & 329 C

c b. 110 KSC & 329 d. 80 KSC & 400 C C

228 what are the numbers of stages in HPC, IPC, and LPC ? a. 11, 12, 6 b. 11, 10, 6 c. 12, 10, 8 d. 12, 11, 6

229 what is the pressure and temperature for HRH? a. 19 KSC & 535 C b. 60 KSC & 340 C

b b. 25.6 KSC & 535 d. 50 KSC & 440 C C

230 What Barring speed for 210MW unit ? a. 10 rpm c. 6 rpm

b b. 3.5 rpm d. 12 rpm

231 From where steam (gland steam) is taken for end seal of HP and LP rotor ? a. Deaerator b. auxiliary steam header c. Both a & b d. none of the above

232 Principle of deaeration is based on. a. Henrys law c. Both a & b

c b. Solubility law d. none of the above

233 How many bearing are there in turbine system ? a. 6 c. 8

b b. 7 d. 9

234 Heating of main steam (MS) during turbine start up is from .? a. 140/6 PRDS b. 140/29 PRDS c. 140/7 PRDS d. 140/14 PRDS

235 Where is the turbine fixed point ? a. LPC front part foundation frame c. IPC front part foundation frame

a b. HPC front part foundation frame d. none of the above

236 Terminal temperature difference for open heater is .? a. more than 1 b. 0 c. less than 1 d. 1

237 which one is the only open heater in the system ? a. LP heater c. Deaerator

c b. HP heater d. none of the above

238 Ammonia dosing is use for.? a. To remove oxygen d. To reduce conductivity

b b. To increase pH d. To remove silica

239 Parameter for single element control is? a. Drum level c. steam flow

a b. feed water flow d. none of the above

240 Condenser vacuum failure occur at... ? a. 0.07 KSC b. 0.089 KSC

b b. 0.7 KSC d. none of the above

241 CW inlet temperature to the condenser is? a. 40 C c. 30 C

c b. 50 C d. 20 C

242 Numbers of ejectors in the system are..? a. 4 c. 2

a b. 3 d. 5

243 Heating of HPC, CRH, RH, and HRH is from ...during turbine startup . a. 140/6 PRDS b.140/29 PRDS c. 140/7 PRDS d. 140/14 PRDS

244 Hydrogen seal oil pressure should be more than ? a. 10 Kg/cm b. 2 Kg/cm b. 3 Kg/cm d. 4.8 Kg/cm

245 Commonly used turbine governing system is.? a.hydraulic c.Electro-Hydraulic

c b. Mechanical d. none of the above

246 Which of the following is not found in a 210MW .. a. Bottom ring header b. Second stage Super Heater c. CC Pump d. Secondary air fan

247 Number of stages of super heating in 210MW and 500MW are ... & .. respectively a. 2 & 3 b. 3 & 2 c. 2 & 2 d. 3 & 3 (same for both)

248 If 210MW (Russian)=1 ; 210MW (KW)=2 ; 500MW=3 then, Circulating water quantity im m3 /hr a. 1>2>3 b. 2>1>3 c. 3>2>1 d. Quantity of flow is same

249 Rated terminal voltage in 210 MW is ..... KV & in 500 MW is ..KV a. 21.00 ; 50.00 b. 6.25 ; 11.75 c. 132 ; 400 d.15.75 ; 21.00

250 Differences between (a) 210 MW & (b) 500 MW ; which of the following is not true a. Excitation system in (a) is static and in (b) is brushless Response of excitation system in (a) is fast than (b) b. c. Hydrogen pressure in (a) is 3.5kg/cm2 and in (b) is 4kg Number of stages of reheat system in (a) & (b) is same d.

251 In 210 MW mill pulveriser is denoted by XPR 803; where 80 is . &3 is . a. diameter of roller (in inches) , number of rollers b.diameter of roller (in inches) , mill fineness c. diameter of roller (in mm) , number of rollers d. diameter of roller (in mm) , number of feeders

252 In 210 MW mill pulveriser is denoted by XPR 803; how is it denoted in 500 MW a. XPR 1004 b.XPR 1003 c. XPR 803 d. none of the above

253 Which of the following is not true a. both in 210MW and 500MW we have TDBFP

a b.In 500MW we have only two types of PRDS

c.in both 210 & 500 MW FD fans are axial reaction typed. a&b

254 Combined cycle run on ..&..cycles a. Rankine & Reverse Rankine c. Rankine & Carnot

b b. Rankine & Brayton d. none of the above

255 Gas power plant is run by ...cycle a. Rankine c. Modified Rankine

b b. Brayton d. None of the above

256 Which of the following is not true in case of gas power plant a. Small size and weight per Horsepower b. Rapid loading capability c. Easy maintanance d. Cooling water is used

257 If (1) is gas power plant (2) is coal thermal plant (3) is combine cycle ; then efficiency is of order . d a. (1)>(2)>(3) b. (2)>(3)>(1) c. (1)=(2)=(3) d. (3)>(2)>(1)

258 Which of the following is true a. Gas power plant works only on Natural Gas c. In gas power plant working fluid is steam

b b. Exhaust temperature of gas plant is 540 oC d. condensor is present in gas plant

259 In unifired combined cycle ..is/are used to produce steam a. only gas b. both gas and coal c.only coal d. none of the above

260 Which of the following is not a true for Combined cycle a. Better reliability b. High Installation cost c. better efficiency than gas and steam cycle d. both a & b

261 Number Of combined cycle(s) module in Anta is .. & Auraiya is .. a. 1 & 1 b. 1 & 2 c. 2 &1 d.2 & 2

262 Which of the following is not true for Anta & Auraiya gas plants a. Both use natural gas as fuel b. exhaust gas temperature in both is >500oC c. There are no steam turbine/module in both d.There is 1 steam turbine/module in both

263 Output of gas turbine under design condition & open cycle operation in Anta is . ; in Auraiya is . a. 100 MW ; 100 MW b. 89.25 MW ; 111.76 MW c. 210 MW ; 500 MW d.111.76 MW ; 89.25 MW

264 Combined cycle outputat designed condition (MW) under based load in Anta is .. ; in Auraiya is . a. 89.25 MW ; 111.76 MW b. same in both c. 210 MW ; 500 MW d. 413.3 MW ; 652.56 MW

265 Which of the following is true a. HP super heater outlet temp in Anta is greater than Au b.LP super heater outlet temp in Anta is greater than Auraiya c. Type of fuel in Anta is not same as Auraiya d. none of the above

266 In Turbovisory System the which parameter is not monitored a. Rotor speed b. Journal Babbit Temp c. HPT I/L Temp d. None of the above

267 In 500 MW, rotor axial shift trip is at a. +/- 1 mm c. a. +/- 0.5 mm

a b. +/- 2 mm d. a. +/- 1.5 mm

268 Absolute bearing vibration is measured at a. JB-1 b. JB-4

d b. JB-2 d. all of the above

269 Shaft vibration is measured with a. Hall probe c. Proximity Probes

c b. Trib bolts d. None of the above

270 Rotor Overspeed can measured with a. Hall Probe c. Hydraulic Transducers

d b. Tacho Generator d. All of the above

271 Rotor overspeed in turbine will not a. Increase Vibration c. Increase Bearing heating

d b. Increase Generation Frequency d. Increase Generation Voltage

272 Rotor overspeed may occcur due to a. Increase in DC excitation voltage c. Underloading of Grid

c b. Overloadingof Grid d. All of the above

273 Hall Probe is generally attached to a. JB-1 c. JB-2

a b. Thrust Bearing d. None of the above

274 In the rotor, Where Trip Bolts can be found? a. Near JB-1 c. In the thrust bearing

a b. Between IPT and LPT d. None of the above

275 Rotor axial shift is measured by a. Hall probe c. Proximity Probes

c b. Trib bolts d. None of the above

276 Rotor axial shift measurement is done in a. JB-1 c. JB-4

d b. JB-3 d. JB-2 (IPT Collar in HPT side)

277 Tuirbine casing expansion is measured a. From a anchor point which is located in the middle of b. From Front pedeststal I c. From thrust bearing d. None of the above

278 Rotor axial shift is measured from the '0' point, which is taken to be the a. thrust bearing workinging pad b. thrust bearing surge pad c. midpoint of thrusting pad and surge pad d. JB-1 midpoint

279 High temperature can be measured using a. RTD in bridge circuit c. A and B

b b. Thermocouple d. None of the above

280 Which is not true about Eccentricity? a.It can predict vibration even when the turbine is on barring gear or lower speed c. Eccentricity is measured in JB-3

d b. It's the deviation between rotor CM from the center of the bearing d. None of the above

281

Axial shift in steam turbines accurs due to a. Thermal expansion of casing c. Differential expansion of casing and rotor

b. Wearing of thrust pad d. Axial thrust


c

282

Differential expansion in steam turbine is due to a. thermal expansion of turbine casing b. wearing away of thrust bearing c. unequal expansion of rotor and casing d. both (a) & (b) above

283

Turbine overspeed trip is done by a. Hydraulic control of ESV and CVs


c. Pneumatic control of ESVs b. Emergency opening of drain line for Turbine governing system oil d. None of the above

284 CVSM used for Turbine overspeed trip stands for a. Control vulve servo meter c. Control variable state machine

a b. Control vulve servo motor d. Control vulve speed management

285 Rotor overspeed alarm is at a. 10 & 16% c. 20%

a b. 5% d. 3%

286 Air flow is controlled by a. FD fan blade pitch b. Cooling Tower

a b. BFP d. DM water

287 SH.Temp. is controoled by a. SH attemp spray c. Hydra step

b b. RH attemp spray d. Acid

288 Supply required for FSSS a. only ac c. both ac and dc

c b. only dc d. oil

289 Expand ATRS a. Automatic Turbine Run Up System c. Automatic Thrust Run System

a b. A Thrust Regulating Station d. Automatic Trial Run System

290 Expand ATT a. Automatic Turbine Testing c. Automatic Tempreture Testing

a b. A Thrust tempreture d. Automatic Trial Testing

291 Expand TSCS a. Turrbine Stress Control System c. Thrust Sensor Control System

a b. Tempreture Switch Control System d. Turbine Switch Control Sensor

292 Expand UPS a. Unintrrupted Power Supply c. Universal Power Switch

a b. Unintrrupted Power Supply d. Universal Power Sensor

293 Expand SWAS a. Steam & water analysis system c. Stator Winding Aux. Switch

a b. Stator water aux. Supply d. Static water analyser Sensor

294 SWAS is used for.. a.Assis twater Treatment c. To avoid corrosion

d b. To avoid deposits in Heat exchanger tube d. all a,b & c

295 How many Panels present in SWAS a.1 c.3

c b.2 d.None of the above

296 Name of the SWAS Panels a.Sample Conditioning Panel c.Recorder Panel

d b.Analyser Panel d.All a,b& c

297 Expand DDCMIS a.Distributed Digital Control Monitoring & Information Sys b.Digital Data Control Map Informatin System a.Distributed Digital Control Management Information Sy .None of the above d

298 Expand SERS a.Sequence of Events Recording System c.Sequence of Extre Recording System

a b.Selection of Events Restore System d.None of the above

299 Expand OLCS a.Open Loop Control System c.Oil Lubrication Control System

a b.Oil Leakage Control System d.None of the above

300 Purpose of Master & Slave Clock System in Plant a.To EnsureUniform Timing Throughout unit & Plant c.To assist DDCMIS & SERS System

d b.To assist Traffic System d.Both a&c

301 DDCMIS consist of.. a.OLCS & CLCS c.MMIPIS & Measurement System

d b.SERS & Slave clock system block d.All of the above

302 Expand MMIPIS. a.Man Machine Interface & Plant Information System c.Mid Measurement Id Part Inc System

a b.Many Machine Industrial Part Inc system d.None of the above

303 How many Nos. of COLOUR CRT are connected to MMIPIS. a.5 b.6 c.7 d.110

304 Function of MMIPIS are.. a.Sequence & modulating controls c.all Plant operation including Emergency condition

d b.Plant start up/shut down d.All of the above

305 which one needed feedback path? a.Open Loop Control System c.Both a & b

b b.Close loop control System d.None of the above

306 Complete the Statement : Transmission line emanate from a _____ station and terminate in a _____ substation. a. Step up , Step Down b. Step Down, Step Up c. Step Up, Grid d. Step Down , Grid

307 The Secondary Current in a Current Transformer in the Switchyard is generally: a. 2 Amp b. 1 Amp c. 10 Amp d. Depends on the load.

: 308 The earth resistance of the Sub-stations is generally kept of the order of a. 0.75 ; b. 0.5 ; c. 1 ; d. 2 ;

309 What does PLCC stand for: a. Power Line Control Circuit c. Power Loss in Control Circuit

b b. Power Line Carrier Communication d. Programmable Logic Control Circuit

310 Which one of the following statement is not correct : a. All Aluminum conductors are used for 11 KV and lowe . For 33 KV lines ACSR are used. b c.A Double circuit line carries double the power than that of a single circuit line .

d. Electromagnetic type of potential transformers are mostly used for high voltages.

311 The number of ground wire(s) used for 400 KV lines : a. 1 c0

b b. 2 d. Not Fixed

312 . Capacitor voltage transformers can be used at voltage at: a. 220KV and above. b. 400KV and above. c. both a and b. d. None of these.

313 Total load on auxiliaries in a power station is of the order of ______ a. 5-7%. b. 7-9%. c. 10-12%. d. 9-12%

314 Choice of circuit breaker is limited by: a. load current and fault MVA. c. both a and b.

a b. type of fault. d. none of these.

315 Which of the auxiliaries following is fed from emergency AC switchgear: a. Scanner air fan. b. Seal oil pump. c. Tub oil pump. d. All of these.

316 Which of the following is not part of unit auxiliary : a. ID fan. c. Lighting system.

c b. FD fan. d. Coal mills.

317 For same standby capability which of the following batteries has higher life expectancy: a. Plante lead acid battery b. Tubular lead acid battery. c. Nickel Cadmium battery. d. None of these

318 Which of following statement is incorrect: a.nickel cadmium battery has longer life than lead acid. b. lead acid batteries has lesser energy/weight ratio than nickel cadmium. d c. lead acid batteries are more robust than nickel cadmiu. plante lead acid battery has more life expectancy than tubular lead acid battery for same stand by capacity.

319 Commonly used Voltage level for communication is ____. a. 220V b. 11KV c. 48V d. 415V

320 Voltage level selected for auxiliaries: a. 6.6 KV c. 15.75KV

d b. 3.3 KV d. 6.6KV or 3.3KV

321 In an auxiliary system _____ voltage level is preferred: a. 3.3 KV. b. 15.75 KV. c. 6.6 KV. d. 11KV.

322 Momentary current ratings of circuit breakers in case of 6.6 KV and 3.3 KV are: a. 55KV,110KV respectively. b. 110KV, 55KV respectively. c. 110KV for both. d. 55KV for both.

323 Which of the following is(are) correct: a. Cost of cabling in 6.6KV is lesser than 3.3KV. c. both a and b.

c b. Copper loses are more in 3.3KV than 6.6KV. d. None of these.

324 Which of the following is part of station auxiliary: a. ID fan. c. boiler feed pump.

b b. lighting system. d. coal mills.

325 Which of the following is not a size standardized for the transmission lines a. Dog ACSR b. Panther ACSR c. Zebra ACSR d. Camel ACSR

326 How many condensers are there in 210 MW unit at the exhaust of LP turbine ? a. 1 b.2 c. 3 d. 4

327 Where is the CEP is located ? a. near hot well c.near HP heaters

a b. near deaerator d.near BFP

328 Where is LP heater no.1 is located? a. inside the condenser c. near LP heater no.3

a b.near LP heater no.2 d. none of these

329 Which is not the turbine lub oil system ? a. main oil pump (MOP) c. feeder oil pump (FOP)

c b. starting oil pump (SOP) d. jacking oil pump (JOP)

330 What type of heat exchange method is used in condenser in 210MW unit? a. parallel flow b. counter flow c. mixed flow d. none of these

331 Ejector performs the following actions in condenser except? a. air evacuation b. non-condensing gases evacuation c. regulates water flow in condenser d. maintain vacuum

332 What is approximate pressure of steam supplied to the ejector from deaerator? a. 3 bar b. 5 bar c. 6 bar d. 2 bar

333 What is pressure inside the condenser approx? a. 0.1 bar c. 2 bar

b b. 0.9 bar d. 4 bar

334 Arrange the correct sequence of condensate flow through 1) CEP, 2) hot well , 3) deaerator, 4) BFP: ________________ b a. 1-2-3-4 b. 2-1-3-4 c. 2-1-4-3 d. 1-2-4-3

335 How many HP and LP heaters are used in one 210MW unit? a 3,4 b. 4,3 c. 4,4 d. 3,3

336 Deaerator is employed principally against __ gas, whose ill effect increases at higher/lower temp of feed water? a. oxygen, lower b. oxygen, higher c. nitrogen, higher d. nitrogen, lower

337 What is the tolerable limit of residual oxygen in feed water going to the boiler ? a. 0.005 cc/lit b. 0.05 cc/lit c. 0.005 kg/lit d. 0.05 kg/lit

338 What are basic principle(s) on which deaerator works? a. Henry's law b. Solubilty law c. Both a and b d. None of these

339 Which factor primarily accelerate the efficiency of deaerator? a. increased contact time b. scrubbing of condensate c. both a and b d. none of these

340 Which is not a component of deaerator ? a tubular type gauge glass c. isolating valves for steam pipes

b. pressure gauge d. Non returning valve.

341 In reference to BFP, what is the pressure value for safe operating of balancing device ? a. 0.1 atm b. 1.5 atm c. 5 atm d. 10 atm

342 How many radial sleeve bearings and thrust bearing are there in BFP? a. 2,1 b. 1,2 c. 1,1 d. 2,2

343 Which is not the essential factor in obtaining fine degree of regulation, in reference to feed regulation system ? a. steam flow from the boiler b. feed water flow from the boiler c. water level in the boiler drum d. inlet and outlet temperature difference of the fluid

344 HP heaters of the same unit are connected in which of the following fashion? a. series b. parallel c. independent d. both a and b

345 PRDS stands for ________. a. Pressure regulation and desuperheating c. Power Regulation and Distribution System

b b. Pressure Reducing cum Desuperheating d. Pressure Depression System

346 The combustion elements of a fuel consists of a. Carbon c. Sulphur

d b. Hydrogen d. All of the above

347 The average composition of air by weight is a. 79% Nitrogen & 21% Oxygen c.77% Nitrogen & 23% Oxygen

c b.78% Nitrogen & 22% Oxygen d. None of the above

348 The maximum combustion efficiency of a boiler depends on d b. Skill in obtaining combustion with the minimum amount of excess a a. Fuel used c. Design of the boiler d. All of the above

349 Which of the following is/are the parts of boiler structure a. Supporting structure b. Gallaries & stair ways c. both a & b d. None of the above

350 A chamber under or adjacent to a boiler in which fuel is burned & from which the combustion products pass into the boiler pro c a. Boiler drum b. Super heater c. Furnace d. None of the above

351 Classified according to wall construction the furnace may be a. Solid refractory setting b. Water cooled walls c. Air cooled refractory setting d. All of the above

352 The function of boiler drum is to a. reduce the dissolved solid contents of the steam c. both a & b b. separate the water from the steam generated in the furnace walls d. None of the above

353 To preheat the boiler feed water before it is introduced into steam drum, we use a. Economiser b. Superheater c. Reheater d. None of the above

354 In a 210 MW H.P. unit, the outlet temperature & pressure of the steam coming out from the superheater is a.480oC & 157 Kg/cm 2 b. 540oC & 157 Kg/cm 2 c. 540oC & 126 Kg/cm 2 d. None of the above

355 How many pulverised coal burners are there for corner fired C.E.type boilers in a 210 MW unit a. 16 b. 20 c. 24 d. 28

356 The oil burners are fed with heavy fuel oil till boiler load reaches to about 25% a. True b. False c. d.

357 For every drop of 20C temperature in flue gases (caused due to air Preheater), there is a X% increase in boiler efficiency. a a. 1 b. 5 c. 7 d. no effect

358 Which type of air Preheater is used in 210MW and 500MW units? a. Regenrative type, Recuperative type b. Recuperative type, Regenrative type c. Regenrative type, Regenrative type d.Recuperative type, Recuperative type.

359 Corrosions and fouling prevails in air Preheater in _________conditions thus they (tubes) are made _______in size (under b a. hotter, shorter b. colder, shorter c. hotter, longer d. none of these

360 Langsdorm type, Ruthemuhle type, tri sector type air Preheater are example of a. Regenerative type Air Preheater b. recuperative type Air preheater c. donkeyswell type Air Preheater d none of these

361 Out of many type of Flue Gas Cleaning equipment, which one stresses on SO2 emission control a. Mechanical Precipitator b. Hailment c. Wet scrubbers d. Electrostatic Precipitator.

362 Approximately X% of total ash produces, in Coal fired power plants, is carried along with flue gases a. 40 b.50 c. 60 d.80

363 Efficiency of modern ESP are of the order of a.90.99 c. 95.99

d b. 99.99 d. 99.00

364 8. In ESP the collecting plates are made like _________ and discharge plates are made like ________. a. Steel plates, thin wires b. Thin wires, steel plates c. Both steel plates d. Cup cone shape.

365 Write the full form of FSSS_____________________________________________________ a. Furnace safeguard supervisory system b. Fuel Safeguard and Supervisory System c. Fuel Supply Supervisory System d. Firing Supervisory and Safety System

366 FSSS is not meant for safety and protection during a. Shut down c. Low load

d b. Emergency conditions d. Regular station operation.

367 What is not a component of FSSS a. Logic cabinet c. Mill panel

d b. console insert d. ESM tab.

368 In reference to FSSS emergency trip signals, the signals originate from ___________logic, transmitted via _________-logic and bypass ____________logic and cause immediate shutdown of unit. a. Unit-Elevation-Permissive b. Elevation-Permissive-Unit c. Unit-Permissive-Elevation d. None of the above

369 In reference to FSSS, the logic systems are designed to operate on

a. AC supply only c. AC and DC both

b. DC supply only d. none of these.

370 The dampers which regulate air surrounding a fuel compartment are termed as a. Fuel Air damper b. Auxiliary damper c. Grass root damper d. none of these.

371 The dampers which regulate air adjacent to a fuel compartment are termed as a. Fuel Air damper b. Auxiliary damper c. Grass root damper d. none of these.

372 Which damper is modulated to maintain fixed differential pressure between wind box and the furnace a. Fuel Air damper b. Auxiliary damper c. Grass root damper d. none of these.

373 The FSSS is consist of following major parts a. Logic cabinet c. Secondary air damper control

d b. consol inserts d.All of above

374 ____________relay are extensively used as retentive memory circuits so as to minimize the power consumption of logic a.Latch relay b. Control relay c. Time delay relay d. Any of these.

375 Furnace safeguard supervisory system has been designed to improve a. Safety b. Reliability c. Flexibility d. All of these.

376 In the present BHEL designed boiler tangential firing system is adopted. a. True b. False c. Wrong Question d. None

377 Which of the following is not a part of the bottom ash system a. Bifurcating chute bypass b. scraper chain conveyor c. Flushing apparatus d. clinker grinder

378 The number of E.S.P. hoppers provided in fly ash system are a. 20 b. 35 c. 50 d. 40

379 Of the total quantum of coal consumed in the boiler the % of ash may be a.50-60% b.30-45% c.60-70% d.20-30%

380 Which of the following is not a type of the cooling tower a.Natural draft b.radiation draft c.induced draft d.forced draft

381 In forced draft cooling tower, the fans are located at . of the tower a.top b.bottom c.middle d.all of the above

382 Which of the following subsystem is not a part of the auxilliary cooling water system a.D M plant b.bearing cooling system c.Turbine lub oil d.condensate water cooling system

383 Clinker grinders are used in . a. Quenched cooler ash hopper system c. Both of them

a b. Water filter ash hopper system c. none of them

384 In a fly ash system, which of the following doesnt have a flushing apparatus under it a. economiser hopper b. air preheater hopper c. stack hopper d. superheater hopper

385 Economiser hopper uses . Water for flushing the ash a. high pressure b. low pressure c. both d. none of them

386 In case of lake cooling, extent of cooling of the hot water (coming out of the condenser after cooling the steam) depends ond a. surface area of water b. wind velocity c. ambient temperature d. all of the above

387 Which of the following about the cooling towers(CT) is true a. induced draft CT fan is located at the top whereas For b.efficiency of forced draft CT is less c. exit velocity of forced draft CT is less d. all of the above

388 Rapid growth of fungus inside the CT and eliminators normally occurs in a. Natural draft CT b. induced draft CT c. forced draft CT d. both 'a' and 'b'

389 The capital cost of natural draft CT is about . % more than that of the mechanical draft CT a. 60% b. 40% c. 10% d. 80%

390 The collection efficiency of ESP is a. 90% c. 97%

b b. 99.9% d. 95%

391 ESP deals with a. ionization and migration c .collection and charge dissipation

d b. particle dislodging and particle removal d. all of the above

392 Recommended ash water ratio in bottom ash is . a. 1:5 b. 1:1 c. 1:10 d. 1:20

393 Actual ash water ratio in Fly ash is a. 1:19 c. 1:25

a b. 1:10 d. 1:5

394 AWRS is used for a. service water c. both of them

c b. bottom ash and fly ash d. none of the above

395 In a coal fired boiler, . % of the total ash will be carried away by the flue gas called as fly ash a. 75% b. 70% c. 80% d. 77%

396 Which of the following doesnt need bulk requirement of water: a. cooling of steam in condenser b. to sluicing out ash produced by burning of coal c. In CHP for dust suppression d. for bearing cooling purposes

397

The temperature of steam at the inlet of RH (in degree C)


a. 345 c. 150 b. 540 d. 50

398

For 500 MW, the pressure of steam at the inlet and exit of RH respectively are (in kg/cm ) a. 43.46, 45.85 b. 45.85,43.46 c. 43.46,43.46 d. None of the above

399

The combined Journal and Thrust bearing is provided between a. HP rotor and IP rotor b. IP rotor and LP rotor c. Either A or B d. Both A and B

400

Cold water passes across the stator windings through a. Plastic tubes b. Steel tubes c. Teflon tubes d. Rubber tubes

401

Hydrogen cooler is a a. Plate Heat Exchanger c. Plate Fin Heat Exchanger

b. Shell tube heat exchanger d. Regenerative Heat Exchanger


D

402

The rotor shaft is a single piece solid forging manufactured from a. Die Casting b. Plaster Casting c. Permanent Mould d. Vacuum Casting

403

To ensure effective sealing of the bearings, the seal oil pressure must be maintained a. Equal to that of Hydrogen gas pressure b. Less than that of Hydrogen gas pressure c. Greater than that of Hydrogen gas pressure d. It depends on the quantity of steam flowing in the turbine

404

B Let P1 = The pressure of Hydrogen in the rotor, P2 = The pressure of water flowing through the tubes of stator w a. Positive b. Negative

c. Zero
405

d. Sometimes positive, sometimes negative


C

The type of Governing system used in 500MW main turbine is a. Hydraulic b. Mechanical c. Electro Hydraulic d. None of the above
2

406

In 500MW, the condenser back pressure is (in kg/cm ) a. 1 b. 0 c. 0.1 d. 1.1

407

In 500MW, the rated power factor is a. 0.85 lag c. 0.85 in phase

b. 0.85 lead d. Can't Say


B

408

The amount of Hydrogen gas produced through the water solution is directly proportional to a. Voltage passing through it b. Current passing through it c. Both (A) and (B) d. Resistance offered by the electrodes

409

To make economical use of electrolysis of water, we prepare a solution by adding ______ with pure water a. Baking Soda b. Sulphuric Acid c. Table Salt d. Caustic Soda

410

The Hydrogen Gas holder System is initially purged with ____ for expelling air a. Hydrogen b. Oxygen c. Carbon-di-Oxide d. Moisture Air

411

The function of SCAPH is a. To increase the temperature of flue gases c. To decrease the temperature of secondary air

b. To increase the temperature of primary air d. To increase the temperature of steam


C

412

Among the following Fans, which one is dealing with gas a. FD Fan b. PA Fan c. ID Fan d. Both (A) and (B)

413

The rotor and casing of IP Turbine expand towards a. Generator b. HP Turbine d. Sometimes on Generator side and sometimes on HP Turbine side , it depends on the temperature of steam entering into the IP Turbine

c. Both (A) and (B)


414

To improve Boiler Efficiency and for better performance of Boiler, we must b. Send more amount of Coal and reduce the amount of a. Send less amount of Coal and more amount of se secondary air c. Incorporate number of super heaters d. Both (B) and

415

The temperature of Flue Gas leaving must be a. To carry the pulverized coal to the furnace

b. Less than a particular temperature i.e. 1200 C

c. Greater than a particular temperature i.e.1200 Cd. It doesnt matter whatever its temperature might be
416

The function of Primary Air is a. To carry the pulverized coal to the furnace c. To ensure primary combustion

b. To carry the pulverized coal to the furnace d. All the above


c

417 Currently, what is the type of header used in Auxiliary steam system ? a) Turbine Auxiliary steam header b) Boiler Auxiliary header c)Both of them d)None of Above.

418 The measuring and recording of temperature differences should be carried out during turbine starting atleast once in every b a) 5 minutes b) 10 minutes

c) 15 minutes

d)22 minutes

419 The temperate difference between casing flange should be within ____ C ? a)20 C b) 100 C c)50 C d)250 C

420 The difference between the flange and stud temperature should exceed ____ C , and the stud temperature should never be _____ than that of flange . a) 10 C , more b) 20 C , less c)20 C , more d) 10 C, less

421 It is not permitted to operate the flange heating device in which of the following condition ? i)If the differential expansion of the rotor is less than 1mm the differential expansion indicating instrument is out . ii)If iii) If the differential expansion indicating instrument is disconnected. a) i & ii b) ii & iii c) I , ii & iii d) none of above 422 The steam is supplied at a higher temperature then that of the turbine casing at the sealing till it comes under control , in a)Contraction of HP & IP b) Expansion of HP & IP c) Both of above d) None of above

424 While supplying the steam to the HP & IP front sealing it should be checked up that spindle leak of valve should be in_______ a a) Closed position under interlock action b) Open position under interlock action c) closed position d) Open position

425 The pressure of the cooling water is kept _______ that of the oil to avoid its mixing with oiling the event of tube rupture . a)slightly higher than b) very higher than c)lower than d) same

426 Stand-by oil pump is a ______ a) Centrifugal pump c)Any of above

a b)Axial Pum d)None of above

427 10 )Oil medium for governing and lubrication system of turbine has a flash point in the range of ___ a) 50 100 C b) 100-150 C c) 150-200 C d) >200 C

428 The oil to the lubricating system at the level of turbine axis is supplied through ____ injector arranged in series . a) 7 b) 4 c)2 d)10

429 Starting oil pump is provided for meeting the requirement of oil of the turbo-set during ___ a) i & iii b) I, ii & iii b) I d) all of the above

i) starting, ii) normal working, iii) a

430 Stand-by oil pump for ____ minutes in the ______ to remove air from the governing system and fill oil system with the oil . b a) 20 , beginning b) 10 , beginning c) 5 , beginning d) 5 , end

431 Which of the following is driven by DC motor ? a) Starting oil pump c) stand-by oil pump

b b) Emergency oil pump d) None of above

432 which one of the following enable during turbine generator start up and shut down , thus preventing damage to the bearing d a) Starting oil pump b) Emergency oil pump c) stand-by oil pump d) Jacking oil pump.

433 The oil of the lubrication and the governing system is cooled in the _______a) water coolers b) oil coolers c) air coolers d) none of the above

434 In order to maintain proper tightening of flange joints, it is necessary to supply steam in which order .. a) Flange followed by stud c) at same time b) Stud followed by flange d) in any order

435 In case the contraction of HP rotor reaches ____ mm and that of IP rotor ____ mm , fresh steam is supplied to the front a) 1.5 mm & 0.8 mm b) 0.4 mm & 0.8 mm c) 0.8 mm & 1.5 mm d) 0.8 mm & 0.4 mm

437 Steam from the Boiler auxiliary steam header does the following work ____ a) interconnection of other boiler b) burner cleaning scavenging c) burner atomising d) all of he above

438 The maximum limit of temperature for the cooling water of the oil coolers should be ___ a) < 18 C b) <48 C c) < 36 C d) <50 C

439 How many colour graphic printers , line and dot matrix are provided for logs , reports and alarms of CRTs connected to MM a a. 2 1 3 b 1 2 3 c 2 3 1 d 1 3 2

440 In OLCS controllers , the maximum numbers of redundant drive control modules are restricted to a. 1 b. 2 c. 3 d. 4

441 In case of failure of system bus or CRT/KBD, How much percentage of total drives (through back up push buttoms) be op a a 10% b. 20% c. 30% d. 40%

442 Memory cycle time of DAS is less than equal to a. 2 micro sec c. 3 micro sec

b b. 1 micro sec d. 4 micro sec

443 Memory expandability of DAS at least equivalent to a. 44 k words c. 64 k words

c b. 54 k words d. 74 k words

444 Function /s of DAS is /are a. Storage of DATA for retrieval at a later date. b. Generation of LOGs, for monitoring the parameters and improving the efficiency.

c. Generation of SOEs for analysing the cause of unit Tripping/ any emergency d.

All of the above

445 How many controllers units (NODES) are there in DAS Architecture ? a. 2 b. 3 c. 4 d. 5

446 How many CPUs are there in one controller unit (NODE) of DAS Architecture ? a. 1 b.2 c. 3 d. 4

447 Program in Controller is divided into how many parts ? a. 1 b. 2 c. 3 d. 4

449 Controller send the data to servers via a. AF100 c. AF300

a b. AF200 d. All of the above

450 MOD drives are used for taking the DATA Backup upto a. 60 MB b. 600 MB c. 400 MB d. 500 MB

451 All Operator Work Stations, Servers, Engineering work station runs on a. Windows XP OS b. Windows Vista OS c. Windows 2000 OS d. All of the above.

452 In MMIPS, 128/256 MB RAM AND 4/6 GB HDD FOR OWS to ensure a. Fast Response b. Slow Response c. Both a and b d. No response

453 The maxPAC backplane used in maxDNA is a. 8 wide c. 32 wide

a b. 16 wide d. 4 wide

454 In DPU logging of SOE resolution is a. 4 mili second c. 2 mili second

d b. 3 mili second d. 1 mili second

455 How many channels are available for accepts voltage / current inputs in DPU ? a. 8 b. 16 c. 32 d. 64

456 In DPU, Scanning time is a. 50 ms c. 150 ms

b b. 100 ms d. 200 ms

457 In the form of Analog input module-IOP 303, how many inputs can take one card ? a.32 b. 16 c. 8 d. 4

458 In the form of Analog input module-IOP-304 ,how many inputs can take one card ? a. 32 b. 16 c. 08 d. 04

459 In the form of Analog output module-IOP320, how many outputs can take one card ? a. 32 b. 16 c. 8 d. 4

ANSWER SHEET

SUBJECT

DATE SIGN. OF EMP.

NAME

EMPLOYEE NO.

SIGN. OF INVIGI. NOTE: PLEASE TICK THE CORRECT ANSWER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B

C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D

34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B

C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D

67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B

C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D

MARKS OBTAINED

SIGN. OF EXAMINER

Вам также может понравиться