Академический Документы
Профессиональный Документы
Культура Документы
Processor Processor type Expansion Bus Bus type Expansion slots using riser cards PCI Express Generation 2 Two Intel Xeon processors 5500 series
NOTE: Depending on the configuration, your system may have either riser 1 or riser 2.
Riser 1 OR Slot 1: PCIe x4, half-length, full-height Slot 2: PCIe x4, full-length, full-height Slot 3: PCIe x8, half-length, full-height Slot 4: PCIe x4, internal slot for integrated card
Memory module sockets Memory module capacities Fourhard-drive systems Eighthard-drive systems Minimum RAM Maximum RAM Fourhard-drive systems Eighthard-drive systems
Drives Hard drives Fourhard-drive systems Eighthard-drive systems Optical drive Up to four 3.5-inch, cabled SAS or SATA drives Up to eight 3.5-inch or 2.5-inch, hot-swappable SAS or SATA drives Optional internal slim-line SATA DVD-ROM or DVD+/-RW Optional external USB DVD-ROM Optional external USB 1.44-MB
Diskette drive Connectors Back NIC Serial USB Video Front Video USB Internal USB Video Video type Video memory
Two RJ-45 (for integrated 1-GB NICs) 9-pin, DTE, 16550-compatible Two 4-pin, USB 2.0-compliant 15-pin VGA
10
Power AC power supply (per power supply) Wattage Fourhard-drive systems Eighthard-drive systems Voltage Heat dissipation Fourhard-drive systems Eighthard-drive systems Maximum inrush current 1840 BTU/hr maximum 2200 BTU/hr maximum Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less. 480 W (non-redundant power supply) 750W/1100 W (redundant power supply) 100240 VAC, autoranging, 5060 Hz
Batteries System battery Physical Height Width Depth Weight (maximum configuration) Fourhard-drive systems Eighthard-drive systems Weight (empty) Fourhard-drive systems Eighthard-drive systems 13.6 kg (29.92 lbs) 13.5 kg (29.7 lbs) 16 kg (35.2 lbs) 22.5 kg (49.5 lbs) 8.94 cm (3.52 in) 43.66 cm (17.19 in) 61.02 cm (24.09 in) CR 2032 3.0-V lithium ion coin cell
11
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets.
Temperature Operating 10 to 35C (50 to 95F) with a maximum temperature gradation of 10C per hour
Relative humidity Operating 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour 5% to 95% (noncondensing)
One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Storage
12