STS The STS Series square tapered steel pole is designed for 2-3/8 tenon mount and features one-piece construction in heights up to 50.
STS SERIES
SHAFT The pole shaft conforms to ASTM A595 Grade A or A572 Grade 55 with a constant linear taper of 0.11 in/ft. POLE TOP A pole top plate and tenon (must specify size) are provided for top mount luminaire or Williams pole top assembly. HANDHOLE Acovered handhole and grounding provision with hardware is provided. FULL BASE COVER The two-piece standardfull-base cover is fabricated from ABSplastic. ANCHOR BASE Theanchor base (baseplate) conforms toASTMA36. HARDWARE Allstructural fasteners are galvanized high strength carbon steel. All non-structural fasteners are galvanized or zinc-plated carbon steel or stainless steel.
HEIGHT*(Must specify)
200 250 300 350 450 1 500 1
1
7 gauge only.
20-50
4 Anchor Bolts w/ Threaded End Galvanized 12 min., each bolt furnished with 2 hex nuts and 2 flat washers
* For available Base Diameter, Wall Thickness and Height combinations, see Load and Dimensional Data Table on page 7C.
H.E . W illiams, In c.
w w w.hew illia m s .c o m
417- 3 5 8 - 4 0 6 5
F a x : 417- 3 5 8 - 6 015
STS
FIXTURE MOUNTING
Designed for pole top tenon. See Williams Pole Top Assemblies for various fixture mounting tenon and arm assemblies.
Pole Shaft
FINISH OPTIONS
Polyester powder coat applied over chromate pre-treatment.
ANCHOR BOLTS
Anchor bolts conform to ASTM F1554 Grade 55 and are provided with two hex nuts and two flat washers. Bolts have an L bend on one end and are galvanized a minimum of 12 on the threaded end. Template provided with every pole and anchorbolt order.
ANCHOR BOLTS
BOLT SIZE (IN) PROJ. (IN) (IN)
BOLT CIRCLE POLE BASE WALL DIA SQ. THK (IN) (IN) (IN) (GA)
Bolt Circle Square Bolt holes 0.25 larger than Anchor Bolt diameter
5.25 5.50 6.00 6.41 6.41 6.81 7.13 7.18 7.88 8.75 8.81
11 7 11 11 7 11 7 11 7 7 7
10.75 11.00 12.00 12.50 12.50 13.50 13.50 14.50 15.75 16.00
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
10.75 11.00 11.50 11.88 11.88 12.63 12.63 13.38 14.25 15.50
0.750 1.000 0.875 0.875 1.250 1.250 0.875 1.250 1.500 1.250
1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.00 x 36.00 x 4.00 1.25 x 42.00 x 6.00 1.25 x 42.00 x 6.00
4.00 4.25 4.13 4.13 4.50 4.13 4.50 4.13 4.50 5.25 5.00
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
OPTIONS
FS Festoon box only NOTE: Casting only. Outlet, cover and hardware by others. The festoon box is located above the access door at 0, approximately 41 above ground level.
90 180
270
OPTIONS
FULL BASE COVER H.E. Williams, Inc. reserves the right to provide an optional twopiece steel full base cover on some applications depending upon the finish requirement and/ or pole base square. FBCS NC Full base cover, steel Nut covers
H.E . W illiams, In c.
w w w.h ew illia m s .c o m
417- 3 5 8 - 4 0 6 5
F a x : 417- 3 5 8 - 6 015
09/08/11RJ
STS
80 MPH 3,4
STRUCT. WT. 5 (LBS) MA X EPA (SQ F T) MA X WEIGHT (LBS)
90 MPH 3,4
MA X EPA (SQ F T) MA X WEIGHT (LBS)
CATALOG NUMBER
20 25
5.25 5.50 6.00 6.41 6.41 6.41 7.13 6.81 7.13 7.88 7.88 8.75 8.81
3.05 3.30 3.25 3.66 3.11 3.11 3.83 2.96 3.28 4.03 2.93 3.80 3.31
11 7 11 7 11 7 7 11 7 7 7 7 7
155 235 205 310 260 375 431 305 475 540 620 730 780
18.0 30.5 16.8 28.5 13.6 23.6 27.4 10.7 23.4 25.7 16.0 23.5 19.4
452 764 422 713 340 590 687 269 585 643 400 588 485
13.8 24.0 12.6 22.5 9.8 17.9 21.6 7.3 17.4 18.8 11.1 16.6 13.2
345 602 315 563 245 448 542 184 435 470 278 415 332
10.7 19.0 9.5 18.2 7.0 13.7 17.3 4.8 13.0 13.8 7.4 11.4 8.7
268 477 238 455 175 343 434 120 325 345 187 287 218
30
35
45 50
3
4 5 6
Maximum weight and Effective Projected Area (EPA) values are based on top mounted luminaires and/or brackets having a centroid 2-6 above the nominal mounting height. Variations from sizes above are available upon inquiry at the factory. Satisfactory performance of poles is dependent upon the pole being properly attached to a supporting foundation of adequate design. See Williams Outdoor Information Section, page 6, for Load and Dimensional Data specifics. Wind map provided in Williams Outdoor information section, pole information page 6. Structure weight is a nominal value which includes the pole shaft and base plate only. 3 x 5 nominal handhole - all others 4 x 6.5 nominal. Pole installations in various parts of the country perform satisfactorily; however, in select locations destructive vibration can occur. H.E. Williams, Inc. is not responsible for vibration induced fatigue damage. H.E. Williams, Inc. warrants this product to be free from defects in materials and workmanship. Any defective part returned within one year from the date of delivery of the goods will be repaired or replaced without charge, F.O.B. factory. This warranty specifically excludes fatigue or similar phenomena resulting from induced vibration, harmonic oscillation or resonance associated with movement of air currents around the product. The above warranties are given in lieu of all other warranties express or implied, including without limitation, the warranty of merchantabilityand the warranty of suitability for a particular purpose. It is expressly stated that H.E. Williams, Inc. assumes no liability for consequential or liquidated damages arising out of a breach of the sale, including any warranties arising therefrom, and buyers remedy shall belimited to repair or replacement of defective parts as described above. Any action for the breach under a sale including any warranties arising therefrom must be commenced within one year after the cause of action accrues.