ALM-28006 Radio Signaling Link Disconnected

Page 1 of 2

ALM-28006 Radio Signaling Link Disconnected


Description
This alarm is reported when the radio signaling link (RSL) between the BSC and the TRX fails.

Parameters
Parameter Name Cabinet No. Subrack No. Slot No. Carrier No. Parameter Description Cabinet number of the faulty board Subrack number of the faulty board Slot number of the faulty board Faulty carrier number

Impact on the System


Alarm Severity Major Alarm Impact The TRX automatically shuts down the power amplifier (PA), and the ongoing services carried on the TRX are disrupted. If the TRX is the BCCH TRX, the ongoing services of the cell holding the TRX are disrupted.

System Actions
If this alarm is generated on the BCCH TRX and if the TRX aiding function is enabled, the BCCH switchover is triggered in the case that this alarm is not cleared within two minutes.

Possible Causes
The CPRI link is unavailable. The transmission between the BSC and the BTS is faulty. The main control board or the TRX board is faulty.

Procedure
1. Check the CPRI port on the M2000. a. Check whether all TRXs on the RF unit report the following alarm on the M2000. 28006 Radio Signaling Link Disconnected Y => All TRXs on the RF unit report the alarm. Go to sub-step b. N => Not all TRXs on the TRX board report the alarm. Go to sub-step d. b. Check for the correlated alarm on the CPRI port of the BTS on the M2000. 26230 BBU CPRI Optical Module Fault 26231 BBU CPRI Optical Module or Electrical Port Not Ready 26232 BBU Optical Module Transmit/Receive Fault 26233 BBU CPRI Optical Interface Performance Degraded 26234 BBU CPRI Interface Error 26262 External Clock Reference Problem 26264 System Clock Unlocked 26235 RF Unit Maintenance Link Failure

mk:@MSITStore:H:\Bahan%20bacaan\Training\BSC%206900\GSM%20BSC6900%20eng... 1/6/2012

ALM-28006 Radio Signaling Link Disconnected

Page 2 of 2

Y => The correlated alarm exists. Go to sub-step c. N => The correlated alarm does not exist. Go to sub-step d. c. Clear the correlated alarm according to the relevant handling suggestions. Check whether the alarm is cleared. Y => The alarm is cleared. No further action is required. N => The alarm is not cleared. Go to sub-step d. d. Obtain the TRX index. Run the MML command RST TRX to reset the faulty TRX on the Web LMT. Check whether the alarm is cleared. Y => The alarm is cleared. No further action is required. N => The alarm is not cleared. Go to step 2. 2. Check the transmission between the BSC and the BTS. a. Check for the correlated alarms on the transmission between the BTS and the BSC on the M2000. 25880 Ethernet Link Fault 25881 MAC Excessive Frame Error Rate E1/T1-Correlated Alarms or PPP/MLPPP-Correlated Alarms Y => The correlated alarm exists. Go to sub-step b. N => The correlated alarm does not exist. Go to step 3. b. Clear the correlated alarm according to the relevant handling suggestions. Check whether the alarm is cleared. Y => The alarm is cleared. No further action is required. N => The alarm is not cleared. Go to step 3. 3. Replace the main control board or the TRX board. a. Replace the RF unit. Check whether the alarm is cleared. Y => The alarm is cleared. No further action is required. N => The alarm is not cleared. Go to sub-step b. b. Run the MML command RST BTSBRD to reset the GTMU. Check whether the alarm is cleared. Y => The alarm is cleared. No further action is required. N => The alarm is not cleared. Go to sub-step c. c. Replace the main control board. Check whether the alarm is cleared. Y => The alarm is cleared. No further action is required. N => The alarm is not cleared. Reinstall the original board. Contact Huawei Customer Service Center.