W68130 ROCLINK 800 Configuration Software

7-July-2008

DESCRIPTION This file describes release 1.80 of ROCLINK 800 Configuration Software (W68130). The file describes the items addressed in this release, addresses compatibility, and provides upgrade instructions. It also includes a revision history. ITEMS ADDRESSED =============== Version 1.75 --> 1.80 (7-July-2008) Summary: Added support for print of user displays. Added active flow and property calculation standard information to meter setup and values windows. Resolved issue viewing pulse inputs on FB107 with Russian regional setting. Added support for option to disable logging of FB503 AGA limit type events. Added support for APM pulse input tags and reverse pulse counts. Added support for ROC800 Series 2. Added ability to calibrate MVS via the configuration window. Added all user point data to a configuration file save. Added coriolis meter type to the Flow-Cal conversion when a mass meter type is selected. Added station name to the online title bar. Added mass meter configuration parameters to the ROC800 EFM report. Added FB107 upstream temperature calculation support. Added FB107 configuration option to disable splitting logs on configuration change. Added support for the FB107 Modbus history table expansion. Enhanced ROC809 Modbus configuration dialog screens. Added ROC800 history wizard. Added FB107 history wizard. Added mouse over graphics for the ROC800 device. Added ability to view displays from file & device to access level 1. Changed ability to create and edit custom display to access level 5. Added support for the FB107 Application Modules. Added Mass meter data to the IO monitor listing. ROCLINK 800 automatically reconnects on change of FB107 baud rate. Added support for the FB107 six channel DO Relay module. Added support for the FB107 eight channel AI/DI module Added port owner field to the FB107 communications port window. Added differential pressure, uncorrected volume, static pressure and temperature to the I/O monitor.

Details: RL800-00002339 RL800-00002338 RL800-00002313 Resolved over writing display number on export/import of display objects. Moved all FST parameters to the end of a ROC800 download sequence. Added ability to enter a forward slash in the phone number field to define an IP port for CDMA modems.

RL800-00002239 RL800-00002192 RL800-00002306 RL800-00002302 RL800-00002266 RL800-00002218

Added Factor "Fa" for Flashpac 1985 EFM report. Enabled Print Preview button after device communications loss. Increased delays when downloading or deleting large FB107 user C displays. Removed ROC300 MVS meter calibration static pressure offset pushbutton. Resolved application launch problems with South Africa regional settings. EFM conversion changes meter tag "special" characters to a space.

OUTSTANDING (UNRESOLVED) ISSUES RL800-00002225 A change of the regional language and numerical preferences may change the values stored in the configuration file generated under different regional settings. To work around this issue set the Windows regional setting to English. FST editor allows for a program to write to read-only parameter. Viewing of minimum and maximum values is not supported for history points. If there is a problem with a download, the user must restart the download from the beginning. Events, alarms, history, and EFM reports do not support the short date format as a regional setting for the OS. PGAS conversion, warm and cold start system events are not present in .evt log. PGAS conversion, communications alarms for MVS are not converted to the .alm file. PGAS conversion, station alarms are not duplicated in the .alm file.

RL800-00000075 RL800-00000163 RL800-00000221 RL800-00000897 RL800-00001345 RL800-00001346 RL800-00001347

COMPATIBILITY ============= Item -----------ROC809/827 Boot ROM Image Flash ROM Image

Part Number ----------W68127 W68126

Version ------1.00 1.03/1.10/1.11/1.12/1.20/1.21/1.22/ 1.23/1.24/1.25/1.30/1.31/1.32/1.40/ 1.50/1.51/1.52/1.53/2.00/2.01/2.02/ 2.10/2.11/2.12 2.00* 3.00* 1.00 1.00/1.10/1.11/1.20

ROC809/ROC827 Boot ROM Image Flash ROM Image FB107 Boot ROM Image Flash ROC Image FB103/FB104

W68232 W68233 W68181 W68182

Boot ROM Image Flash ROM Image

W68129 W68123

1.00/1.10 1.00/1.10/1.11/1.12/1.13/1.20/2.00 2.10/2.12 2.20/2.21/2.22/2.23 1.04/1.08/1.10/1.11/1.12/1.13/1.14 2.30/2.40/2.41/2.42/2.43/2.44/2.45/ 2.46/2.47/2.48* 1.00 1.10 1.10 1.10

ROC306/312/364 FlashPAC Flash ROM Image W68067 FB407 Flash ROM Image FB503/FB504 DL8000 Boot ROM Image Flash ROM Image W68044 W68061 W68127 W68201

GB601/GB602 GridBoss Flash ROM Image W68081 Flash ROM Image W68082

*As of this writing, this version has not yet been released but is expected to be supported. COMPUTER REQUIREMENTS ROCLINK 800 software runs on most IBM-compatible personal computers (PCs). The PC can be a desktop or a portable computer, but should meet the following minimum requirements: CD-ROM drive. Pentium-class processor (233 MHz or greater recommended). Windows NT 4.0 (Service Pack 6), 2000 (Service Pack 2 or greater), XP (Service Pack 1 or greater), or Windows Vista. 64 MB of RAM (Random Access memory). SVGA color monitor, 800 x 600 pixels. Font Size - Small Fonts. 70 MB of available hard disk space EIA-232 (RS-232) serial connection, a dial-up modem connection if the ROC has dial-up communications card installed or a TCP/IP connection. NOTE: If there is no serial port available, RAS recommends the use of a USB to Serial adapter (such as the Bafo Model BF-810). NOTE: Installation and upgrades of ROCLINK 800 on the Microsoft Windows Vista platform have been successful. ROCLINK 800 has been tested on the Vista platform and is fully compatible. It is required that user account control be temporarily disabled prior to performing the installation. This will ensure that files will be copied and not be limited by Vistas security enhancements. You can disable user account control using MSCONFIG:

1.

Launch MSCONFIG by from the Run menu. Select the START icon in the lower left hand corner, type MSCONFIG in the start search field, and press enter.

2.

Click on the Tools tab. Scroll down till you find "Disable UAC". Click on that line. 3. Press the Launch button.

4. A CMD window will open. When the command is done, you can close the window.

5.
to apply.

Close MSCONFIG. You need to reboot the computer for changes Note that you can re-enable UAC by selecting the "Enable UAC" line and then clicking on the Launch button.

UPDATE INSTRUCTIONS =================== Follow the installation procedures below. NOTE: The update wizard does not support downgrades. If you require an earlier version, remove the existing version, remove the directory, and install the earlier version. INSTALLATION PROCEDURES: 1) Obtain the CD or .ZIP file containing the installation files. 2) If you have the .ZIP file, extract the files (example location is c:\temp\). 3) Close all applications. 4) If you have a lettered version of ROCLINK 800 installed, uninstall it at this time. 5) Start the setup program using one of the following methods: A) Insert CD. If autorun is enabled, the setup program automatically starts. B) Run setup.exe from the root directory of the CD ROM drive or from the location to which the .ZIP file was extracted. 6) Follow the on-screen instructions. You may need to reboot your system depending on the existing version of some operating system files. NOTE: After the installation, if you receive a DB permissions error after you log on to ROCLINK 800: 1) Verify that the active Windows user (account) has read/write permissions to the *.mdb files in the ROCLINK 800 directory. 2) Close all applications and run the MDAC installation utility located in the \apps directory of the installation CD.

REVISION HISTORY ================

Version 1.74 --> 1.75 (16-October-2007) Summary: Added support for Windows Vista. Please read the computer requirements section of this document for more information. Added support for ROC800 APM point fail alarms. Added support for DL8000 transactional history modifications. Added ability to convert ROC306/312/364, FB103/104, FB107, FB407, FB503/504 device types .efm report format to .CFX Flow-Cal format. Added ability to convert ROC800 .efm report files to .det format. Limited to the first five configured meter runs Requires one meter run per station Alarms are not converted Added ability to edit FST code offline from a .800 configuration file.

Details: RL800-00002279 RL800-00002278 RL800-00002277 RL800-00002251 RL800-00002246 RL800-00002242 RL800-00002241 RL800-00002222 RL800-00002185 RL8000-0002112 RL800-00002148 Moved FST point types to the end of the download sequence to prevent issues with start of an FST prior to download of associated point type parameters. Increased display size limits for saving ROC800 configurations with large keypad display user program files. Converted FB504, FB104, and FB107 EFM files properly display the uncorrected volume for .aga and .det file formats. Corrected need to first configure a FB103 or FB107 DI point type for download of DI configuration. Added ability to store ROC800/DL8000 user displays in the RL800 folder instead of in unit. Enhanced modem number string to allow decimal point. Resolved issue where six characters can be entered for an FST label. Activated FB107 PID Apply button on a paste of data. Resolved issue with invalid reference notifications reading FB407 and ROC300 FST code after downloading the configuration file. Enhanced FB500 series configuration download to include the system variables. Changed FB107 converted file format to a .det from .aga.

Version 1.73 --> 1.74 (11-June-2007) Summary: Added support for MVS IO module. Added support for ROC800 User defined history segment configuration. Added support for ROC800 read directory contents, Opcode 203. Added support for ROC800 version 2.10 expanded DS800 point type 122 parameters. Enhanced PI frequency parameter to allow data entry when in manual mode. Removed daylight saving time for support of ROC800 updates. Added support for ROC800 PID minimum control time parameter.

Added support for ROC800 communications response delay parameter. Added support for ROC800 maximum number of FST instructions attempted parameter. Added support for ROC800 Thermocouple EU offset for meter runs. Added support for GridBoss District Regulator and Low Pressure Point products. Added support for DanLoad 8000 device type.

Details: RL800-00002173 RL800-00002179 RL800-00002176 RL800-00002169 RL800-00002162 RL800-00002123 RL800-00002051 RL800-00000965 ROC800 Master Comm Status is now a read/write parameter. Enhance EFM report to display FB107 ISO calculation method. Enhanced FB103 EFM report to display ISO user program calculation methods. Added the ability to enter an offset (zero shift) for the ROC800 v2.02 static pressure. Resolved issue with HART AI calibration sequence. TLP IO mapping resolves problem with addition of IO to a ROC300 and FB407. Enhanced ROCLINK 800 to use TLP IO mapping for FSTs. ROCLINK continues reading data when it encounters a timestamp value of 0.

Version 1.71 --> 1.73 (23-Feb-2007) Summary: Added the capability to import and export display objects to more efficiently merge and edit displays. Added support for FloBoss 107 license key administration. Added capability to display history from ROC800 keypad display. Added support for ROC800 v2.10 FST parameters. Enhanced security filtering by adding user program tree and menu selections.

Details: RL800-00002121 RL800-00002107 RL800-00002103 RL800-00002100 RL800-00002099 RL800-00002088 RL800-00002084 RL800-00001527 Added EFM File Conversion support for non-TLP-related alarms and events. Enhanced ROCLINK 800 to perform retries on download on ROC800 after system-variable warm start. Enhanced ROCLINK 800 to assure retention of meter station selections during ROC800 download. Enhanced ROC300 and FB407 converted EFM report to properly display uncorrected volume. Increased resolution for total mole to the same resolution as the molecular weights. Enhanced ROCLINK 800 to retain FB100 toolbar and menu IO selections updates after a cold start. Added pass-through support to the FB107 configuration file. Enhanced FB107 display administrator to show memory used and available information.

Version 1.70 --> 1.71 (17-Nov-2006) Summary: Support added for FloBoss 107 device type. Support added for ROC800 version 2.10 parameters. Enhanced calibration to include support for static pressure offset for the ROC800.

Details: RL800-00002066 RL800-00002041 RL800-00002035 RL800-00002024 RL800-00002015 RL800 version 1.71 ROC800 configuration files indicate presence of ACIO modules only when modules are present in the device. RL800 version 1.71 allows user to re-span AI value in calibration mode on ROC300 and FB407. Addition of frequency to I/O monitor for FB107 Pulse Input point type. Changed ROC800 PI point today's total read/write from read/only for version 2.10. Changed ROC800 FST instruction pointer from read/only to read/write for version 2.10.

Version 1.60 --> 1.70 (29-Sep-2006) Summary: Support added for ROC800 user define point types 196 through 255 Support added for ROC800 version 2.10 parameters Support added for ACIO Module Support added for Advanced Pulse Module. Enhanced calibration to include support for static pressure offset for the FB103, FB500, ROC300. Support added for ROC300 1985 AGA meter run configurations. Enhanced Modbus history table to include support for override mode 2 in the ROC800. Enhanced meter calibration form to allow multiple deadweight tester entries for mid point 3. Enhanced FB103 and ROC809 calibration window to include history. Support added for new ROC800 meter alarms. Support added for accessing TLP data types from a ROC300 and FB407 FST.

Details: RL800-00002007 RL800-00001994 RL800-00001973 RL800-00001970 Addition of Override PID threshold field for ROC800 Firmware 2.10. ROC800 Analog Input adjusted A/D 0% and 100% is now a read/write parameter in ROC800 Firmware 2.10 Addition of %Deviation field to FB500 Meter input verifications. Addition of radio button to Modbus history table for support of point type 119 parameter 123

RL800-00001953 value. RL800-00001922 RL800-00001920 RL800-00001912 and RL800-00001906 RL800-00001904 RL800-00001497

Calibration, change made to store the previous range for calculating the calibration report as found Default configuration files have been added for the ROC300, FB407, and FB500 products. Number of points are now updated on pull down menu or toolbar. User Correction Factor has been added to the FB103 FB503 EFM report. Config Tree error is no longer received after update of FB407 firmware. The Modbus Host Parameters of the Communications port screen has been enhanced to show the correct value. FST, allow user access to meter input TLPs for ROC300 and 400.

Version 1.51 --> 1.60 (06-Dec-2005) Summary: FB503/FB504 support added. User manual and help updated. PGAS conversion upgraded to version 1.4.0.0. FlowCal conversion upgraded to version 1.4.0.0. EFM Export conversion upgraded to version 1.8.0.0. Details: RL800-00001354 RL800-00001672 RL800-00001674 RL800-00001775 RL800-00001801 RL800-00001819 RL800-00001823 RL800-00001824 RL800-00001829 RL800-00001834 RL800-00001837 RL800-00001840 A utility for downloading flash to the FB104 PIM and FB103/104 6-Point I/O Termination Boards has been added. MVS calibration, event log entry may indicate successful calibration even though communication was lost with MVS. Improve MVS calibration sequence when a sensor or communication failure occurs. A batch EFM conversion utility has been added. For FloBoss 504 units, added TIM Integrity level to EFM report. For FB103/104 and FB503/504 units, allow only pulse input points to be assigned to the meter input in AGA7 applications. While connected to a ROC800, the PID Tuning Screen's label has changed from "Integral Deadband" to "Control Deadband". The File-New screen for the ROC800 has been enhanced to support version 2.XX of firmware. The Update Hardware procedure for FB103/104 units allows the user to skip firmware update when the firmware is already at the latest version. FST Editor handles use of the compare instruction (>) with large constant values. File New for the ROC800 has been enhanced to default the COMM port of an MVS module to 9600 baud. ROCLINK calculates and displays a program CRC for user programs downloaded to FB103/104, FB407, and ROC300 units.

RL800-00001841 RL800-00001842 RL800-00001848 RL800-00001851 RL800-00001853 RL800-00001858 RL800-00001859 RL800-00001871

RL800-00001878

Filling all of the ROC800's User Define Points will no longer cause errors to be displayed. For FB407 units, a floating point value can be entered for scan period of I/O point types. When creating a new configuration for a FB103 unit, unit labels are properly updated when the Metric option is selected. PGAS, FlowCal, and EFM Export has been updated to the latest OCX files. Full support for version 1.04 of the FB407 has been added. Added Modbus conversion codes options. Data precision value is saved to keypad display file. A NaN value can now be overwritten. Previously, once a NaN value was shown in a Softpoint, for example, attempting to place a new value in the softpoint would be unsuccessful. A warm start and reconnect is not required on expanded 8-point to 16-point change.

Version 1.50 --> 1.51 (31-Aug-2005) Summary: Added MMI 3711 and 4700 support. ROC300 Flashpac version 2.20 and greater support. Number of FST lines increased for FB103/104. Details: RL800-00001698 RL800-00001720 RL800-00001738 RL800-00001742 RL800-00001762 RL800-00001771 RL800-00001774 RL800-00001786 User Display, User point tag in point number field doesn't update without reconnecting. User Displays, Data type S32 (INT32) not displayed properly. ROC809, AGA7 Static K Factor label should show correct units for Meter Type. ROC809, User Program Status not saved to/loaded from configuration file. After EFM conversion to .AGA format, the history for Today's Total shows zeros. WDB & WTM data does not get displayed properly when viewing history. FST - Number lines increased from 300 to 400 for FB103/104. Range checking for Configure/Modbus/Configuration /Start Register is incorrect.

Version 1.40 --> 1.50 (22-Feb-2005) Summary: ROC809 Keypad/Display support. FB103/FB104 flash firmware version 2.12 support. Various help additions and enhancements. Details: RL800-00000070 You will only be prompted to save an FST if a change has been made.

RL800-00001112 RL800-00001228 RL800-00001338 RL800-00001398 RL800-00001417 RL800-00001432 RL800-00001433 RL800-00001480 RL800-00001507 RL800-00001519 RL800-00001522 RL800-00001529 RL800-00001538 RL800-00001542 RL800-00001543

RL800-00001546 RL800-00001570 RL800-00001578 RL800-00001596 RL800-00001606 RL800-00001608 RL800-00001641 RL800-00001647

RL800-00001648

Print Preview, conversion to .xls format no longer causes file corruption error on very large conversions. Support for the ROC809's Keypad and Display has been added. The screen layout for the EFM conversions screen has been changed to more clearly show the options available for the various ROC types. File\New, support has been added for the HART module when using a ROC809. EFM, Daily and Periodic report data is now placed under the header instead of on the next page. Min\Max values are now viewable for the FB407. Viewing of history is now consistent with labeling of periodic data for the FB103 and the ROC809. Flags, an enable/disable flag for user programs was added to the FB407. After downloading an FST, you are now prompted to enable the FST. Calibration, ROC809 meter calibration will now allow calibration of thermocouples. After creating a .800 file from File-New, you are now prompted to open the file. Displays are now cached after reading them once (from the ROC) for the session. FB103, FST instruction pointer is now writable. FB407 User Program Administrator now has a "Download & Start" button to be consistent with other product screens. ROC809, when downloading a configuration to the ROC, the HART point type is now sent with the other I/O points. This will ensure that the points are available if they are used by such things as history or meter runs. FB103, the header of the history point when viewing history is now displayed correctly. ROC809 HART, cancellation of a calibration no longer displays a misleading dialog box. FB103/FB104 - Added support for Point Type 55, parameters 56 and 57 (MODBUS current date and time registers). ROC809, additional HART parameters have been added to the default list of available inputs for sampler and PID. ROC809, The HART channel I/O object has changed from a radio button to a label. ROC809, support for parameter 123, History Index Mode, for point type 119 has been added. FB103, PID set point input is now disabled in manual mode when set point tracking is enabled. Additional communications are now shown in the Debug Communications Dialog box. It now shows communications that was received between the last valid response and the next request. RTS timing and the decoding of responses with noise ahead of the valid bytes have improved.

Version 1.30 --> 1.40 (22-Oct-2004) Summary: ROC809 HART Module Support. ROCLINK 800 Display Editor Enhancements. PGAS conversion upgraded to version 1.3.0.0. FlowCal conversion upgraded to version 1.3.0.0. Details: RL800-00001303 RL800-00001308 RL800-00001309 RL800-00001310 RL800-00001322 RL800-00001337 RL800-00001340 RL800-00001352 RL800-00001357 RL800-00001358 RL800-00001379 RL800-00001384 RL800-00001387 IP, reconnect to ROC809 is now established after a warm or cold start. Upgrade Exports using Active Reports was upgrade to version 1240. File New, Added 6 point I/O board for the FB103/FB104 products. PGAS, quotation marks at the beginning and end of .vol file are no longer created. Installer: Created a directory to place the custom displays for user programs. The ROC_User.mdb file no longer has the chance of getting overwritten on an upgrade. A copy of the ROC_User.mdb file is made during the installation (upgrades) for backup purposes. Flo-Cal conversion, the correct archive type (134) is referenced for totalization instead of 124. Calibration, percent deviation calculation in a calibration report (for a calibration verify) has been updated. The icons for soft points and thermocouple have been changed. ROC809, meter calibration zero shift no longer sends a value with the incorrect sign to the device. Flow-Cal version 1.3.0.0 is now included in the installation. Calibration, AI points was previously left in manual if the AI Calibration tab is left before selecting the combo box and points to another AI Calibration tab. ROC809, Modbus Registers - Selecting of a com that has been renamed to a number between 1 and 5 caused problems with the selection. ROC809 HART module support was added. If more than one modem is installed, the selection box (to select which one to use) is no longer covered by another window. The example displays shipped with ROCLINK 800 have been updated to show some of the new features available with the new display editor. File New, for FB103 and FB104 have been updated. PGAS conversion version 1.3.0.0 has been added to the installer. ROC809 History now supports mixing of FST date, FST data, User Program date, User Program data, and regular history data and dates. FST, read of Timers is now performed properly.

RL800-00001388 RL800-00001389 RL800-00001394 RL800-00001396 RL800-00001400 RL800-00001412 RL800-00001436 RL800-00001444

RL800-00001449 RL800-00001452 RL800-00001455 RL800-00001456 RL800-00001469 RL800-00001470 RL800-00001476

Calibration, support has been added for static pressure offset for the FB407. FB407 - PID, in override mode, you were unable to correctly configure the Primary PV and Override Output. Idle time between packets of Data for the FB103 and FB104 are now configurable. The ability to download and retrieve User Displays in the FB103/104 have been added. ROC809, inputs are now put into manual when the Freeze pushbutton is pressed. Help, various help sections have been updated. Display - Added the ability to download User Display with UserC Program.

Version 1.23 --> 1.30 (21-Apr-2004) Summary: Support for version 1.30 of ROC809 firmware. Support for version 2.00 of FB103 firmware. Support for version 1.11 of FB407 firmware. PGAS conversion upgrade to version 1.1.0.0. FlowCal conversion upgrade to version 1.2.0.0. Details: RL800-00001241 RL800-00001238 RL800-00001237 RL800-00001234 RL800-00001218 RL800-00001217 RL800-00001209 RL800-00001206 RL800-00001197 RL800-00001187 RL800-00001182 RL800-00001171 RL800-00001168 RL800-00001157 RL800-00001154 PGAS, volume data is now consistent between totalize and accumulated. PGAS, conversion of volume data will now properly handle force end of day. ROC809, change from momentary mode to toggle no longer only sends the change to momentary. PGAS, volume file - periodic ending data is now associated with the correct time (not one hour late). ROC809, added support for modbus over IP parameters. Modem communications is now handled consistently independent of the override modem init string selection. ROC809, update firmware menu selection is now correctly enabled when the ROC is in firmware update mode. ROC809, added support for variable K-factor to turbine meter setup. The Device Type is now appended to the Station name and connection type in the form name. A 50 character modem phone number is now supported. FB103 the User program status correctly shows that current status following a download. ROC809, the Frequency parameter has been added for the pulse input. For the TLP selection form, the Point Type is not displayed if the logicals don't exist. FB407, the second DO output of the PID is now correctly written to the correct parameter. FB407, downgrades (to an older version of flash code) are now supported.

RL800-00001153 RL800-00001152 RL800-00001144

RL800-00001143 RL800-00001142 RL800-00001136

FlowCal conversion, now handles an MVS configuration set to hold last value correctly. FlowCal conversion, now handles MVS calibration and alarm limits correctly. Although this has not been tested and is therefore not supported, you can run multiple version of ROCLINK 800 by using the '/multi' switch. From Start-Run, you can type in: "c:\program files\roclink800\roclink.exe" /multi to allow the second instance to run. FB103, allows for the editing of daylight savings time clock parameter in a configuration file. Clock, leap year dates are now read correctly. ROC809, the Master Poll Timeout and Master Poll Number of Retries parameters have been added to the modbus configuration screen.

Version 1.22 --> 1.23 (29-Oct-2003) Summary: Saving of more than 32,767 records of history is now supported. FB103 configurable history point sizes are now supported. Details: RL800-00001110 RL800-00001113 RL800-00001114 RL800-00001119 RL800-00001124 Saving and 'Print Previewing' of more than 32,767 records of history is now supported. FB103, An opcode error no longer occurs after downsizing the number of history points. Requests were being made for points that were removed. A regional setting of 'Spanish - Mexico' no longer causes the MSJET database engine to cause an error while saving a configuration. Saving a configuration with UDP's configured and no user program installed no longer fails while downloading. FB103, changes to the DO status on power reset was incorrectly sending the value to the status parameter.

Version 1.21 --> 1.22 (15-Oct-2003) Summary: Included a workaround for running out of resources when reading a lot of entries in history. Details: RL800-00001104 Reading of more than roughly 20,000 history entries no longer results in the automation client running out of resources.

Version 1.20 --> 1.21 (10-Oct-2003) Summary: Tested with FB103 version 1.20. Tested with ROC809 version 1.22/1.23.

Corrected FB407 version 1.08 support in the areas of FSTs and EFM Reports. EFM Export utility for the FB103 has been improved. Range checking has been added for Point Type 13, parameters 21,22 and 23. Various EFM Enhancements for the FB407 - removed stream and tap type reference. Various EFM Enhancements for the FB407 - added meter factor parameter. Various EFM Enhancements for the FB407 - more precision added for Flow Minutes and Uncorr Volume. Various EFM Enhancements - change uncorrected flow input parameters from number to text. The "ABC, 2000" entry has been removed from the ROCLINK 800 security database. ROCLINK 800 now correctly reads and interprets the user data (user point type) parameters from the FB407 version 1.08. Various error 91 errors have been corrected when working with a FB407 - FST editing offline. Various error 91 errors have been corrected when working with a FB407 - frmConfigTree error 91 is no longer received on close of online window. Various EFM changes - raw pulses for input other than first PI will no longer be zero. When an export is performed from a .EFM to a FlowCal, the GMT bit is now set to default. The EFM conversion utility now correctly uses Point Type 10 instead of Point Type 3 for DP. A error 2704 is no longer received when an attempt to select a new user program during start sequence. Using a FB103 configuration file, a PID tree item is not longer shown if the file was created without a PID. The message when connecting to an unsupported device now lists the FB407 as a supported device. Plot, a run-time error no longer appears if the only segment archive types are FST data\time. When viewing ROC memory, a space is no longer displayed as a . in the text representation window. The EFM conversion/export utility status bar now correctly updates even when overwriting a file. When connected to a ROC809 with firmware < 1.20, saving the configuration will no longer display an error attempting to read displays (Note: Before this update, the configuration WAS saved in its entirety with the exception of the FST's which should be saved by hand). Various EFM Enhancements for the FB407 version 1.08 no longer displays Primary Scale Factor in Uncorr Flow input. Selecting ROC Security when connected to a ROC809 with version 1.1X version of firmware will no longer result in an indefinite showing of the hourglass.

Details: RL800-00001017 RL800-00001018 RL800-00001019 RL800-00001021 RL800-00001022 RL800-00001024 RL800-00001025 RL800-00001027 RL800-00001028 RL800-00001030 RL800-00001031 RL800-00001032 RL800-00001035 RL800-00001036 RL800-00001037 RL800-00001038 RL800-00001039 RL800-00001044 RL800-00001046

RL800-00001047 RL800-00001051

RL800-00001053 RL800-00001061 RL800-00001060 RL800-00001059 RL800-00001058 RL800-00001057 RL800-00001055 RL800-00001054 RL800-00001073 RL800-00001074 RL800-00001076 RL800-00001081 RL800-00001082 RL800-00001083 RL800-00001087 RL800-00001088 RL800-00001090 RL800-00001091

Most ROC and FB references have been changed to 'Device' for clarity. An error 91 is no longer received on a cancel of FB103 update firmware. Various EFM Enhancements for the FB407 - flange\pipe pressure tap has been removed from a FB103 AGA92 EFM report. Various EFM Enhancements for the FB407 - daily history for FB407 version 1.08 is now displayed. Reconnecting to a ROC809 with a version of firmware prior to 1.21 no longer redisplays the warning message about the firmware and RTD support. Within the TLP list, the description of parameters within Point Type 42 now also shows (Km3). EFM reports now correctly display data for the pulse input configured even if it is not the first one. The Station Base Density parameter (Pt 112, Param 61) is now R/W from user display. FB407, User displays with data type of singlecharacter ASCII no longer creates a field that's too small to enter valid data. FB407, FSTS accessing the AO, DO, and TDO points, now correctly compile with the correct references. AI calibration cancel event is now properly decoded. It no longer shows OPC 1. FB407, FST labels are now read and saved to file. FB407, Instruction pointer are now correct when monitoring an FST. FB407, FST - start timer is now displayed with the correct conversion. User Programs displays, widened ASCII fields to view all characters. 809, Update firmware has been disabled when connected via Ethernet since it is not supported. FB103, download of configuration file now correctly sets the daylight savings time setting. FB407, update firmware event description for main flash update is now "Main".

Version 1.10 --> 1.20 (6-Aug-2003) Summary: Added Support for the FB103 version 1.11, 1.12, 1.13, and it is expected that it will work with the 1.20 release. Added Support for the FB407 version 1.08 and it is expected that it will work with the 1.10 release. Added support for ROC809 Flash Firmware Versions 1.21 and is expected that it will work with the 1.22 release. .EFM files can now be exported to .AGA and .DET files if it was created for a FB103 or FB407. Details: RL800-00000119 RL800-00000145 RL800-00000235 Access levels have been added to the security model. Indication now given that the reset occurred. The MVS sensor screen now changes units when set to metric (on the screen only).

RL800-00000236 RL800-00000251 RL800-00000286 RL800-00000300 RL800-00000320 RL800-00000354 RL800-00000393 RL800-00000454 RL800-00000497 RL800-00000504 RL800-00000581 RL800-00000606 RL800-00000658 RL800-00000706 RL800-00000707 RL800-00000712 RL800-00000728 RL800-00000732 RL800-00000734 RL800-00000735 RL800-00000754 RL800-00000767 RL800-00000768 RL800-00000775 RL800-00000776 RL800-00000810 RL800-00000819

The user is now prompted asking that a write to MVS is necessary when an applicable parameter is changed. A parameter has been added to change the rate at which displays are updated. ROC809 PID form: the update button graphical border is now longer 'cut off' on the left-hand side. You are now able to change both the Status and the Scanning parameters within DO's of the ROC809. RTD/TC: 'Units' is no longer the caption for 2 different entries. Download, status bar is now more linear, with respect to time, during data downloaded. Utilities, MVS 'set to factory defaults' now has an "Are you sure?" pop-up box. You can now plot the first 4 history points retrieved in the history view. You can now view memory of the FB103 and FB407. User programs, name and version field are now cleared when a user program is cleared for the FB103. PID Loop Value column has been made more intuitive. In all TLP List Selections, the Data Type and read access (Read-Only or Read/Write) is now listed for reference. ROC809 ROC Displays are now supported in versions 1.21 or 1.22 of firmware. User defined displays are now saved with the configuration file. You can now use the saved user defined displays when working off-line with a configuration file. System AI's and the I/O Board AI scan period are now configurable. A notification is provided when attached to the FB103 and FB407 when a user program is already installed when downloading it. Various locals are now supported. The modem initialization string should be a length of 50. The phone number now allows '#' and *'' for ROCLINK Communications. ROC809, System AI, the units selection has now been added to the form. When setting the clock, the correct AM or PM is now sent to the Roc. Small floating point values (absolute value < 0.0001) are now displayed. When working with displays, ROCLINK 800 now requests the correct logical number for multiple logical type displays. Once a user program is started, a reconnection occurs to take advantage of any possible TLPs that have been added. 809, Download: additional parameters can now be downloaded for the System AI's, Time, DS800, and Internet configuration. When exiting calibration, a message is provided asking if the points should be placed on-scan.

RL800-00000837 RL800-00000847 RL800-00000860 RL800-00000864 RL800-00000878 RL800-00000881 RL800-00000892 RL800-00000902 RL800-00000908 RL800-00000914 RL800-00000916 RL800-00000917 RL800-00000919 RL800-00000921 RL800-00000933 RL800-00000934 RL800-00000935 RL800-00000936 RL800-00000941 RL800-00000949 RL800-00000967 RL800-00000968 RL800-00000969 RL800-00000972 RL800-00000973 RL800-00000978 RL800-00000979

User Level Security Support has been added. A warning is provided if an RTD Module is detected with version of ROC809 firmware of less than 1.21. Within viewing of history, the year is now correctly represented when connected to the FB103. User Alarms now correctly show that it has been set or cleared within the alarm log viewing while attached to the ROC809. Firmware updates and configuration file downloads are now logged to the Roc. 'From disk to ROC event' is now logged by ROCLINK 800. Exit box on 'download firmware version mismatch' popup message now cancels operation. Help about, build date is now correctly displayed no matter what date format is selected within the operating system. FB103: DP, SP, and TMP meter values fields are no longer always displayed in imperial units. WDB & WTM data now gets displayed properly when viewing history. NAN values are now handled more elegantly within displays. ROC809, the reference temperature parameter has been added to the sensor write notification window. Displaying of very large numbers have been enhanced in displays. The number of RAM history points are now reported in the EFM report system parameters section. Event and alarm log export formats have had their need date\time header adjusted. History, press of close button or X box will now stop requesting more data. When exporting to Excel(TM) format, the sixth data column now lines up with its header information. Export of Daily history to html format has been enhanced as far as the position of the date and time. When talking to an TCP (IP) or CDPD device, the packets are no longer split based on the amount of activity. Range checking is now performed on custom displays based on the data type of the parameter. EFM, Reynolds number for ROC809 is now displayed in same units as meter values. EFM, Energy Yesterday units is now displayed the same in the meter values window. EFM, liquid calculation standard is displayed as "ISO". License Key Administrator - the width of Application Name has been widened. Additional items are displayed in print preview while running at 800X600 screen resolution. Added EFM Export support for the FB103. Added EFM Export support for the FB407.

Version 1.00 --> 1.10 (3-Feb-2003) Summary: Added Support for the FB103. Firmware Versions 1.00 and 1.10 are now supported. PGAS/Flow-Cal native format support is provided via a conversion from a collected EFM Report. Added support for ROC809 Flash Firmware Versions 1.10/1.11/1.12/1.20. ================================================================== (c) 2008 Remote Automation Solutions, division of Emerson Process Management. All Rights Reserved