Bolt Torque calculation for flanges 30 600#

Studbolt diameter: Studbolt material: Formula used: 2 ASTM A193 B7

T = k . Fi . d
T is Torque in Lbs.ft K is friction factor (0.15 for lubrication, 0.2 for dry ) Fi is pre load force = 0.75 x A2 x Sp A2 is core surface ( /4 x 1.8443) Sp is proof strength (105,000 psi) D is nominal outside diameter of bolt (2 )

Tlubricated Tdry

= 5260 lbs.ft = 7014 lbs.ft