L74M, L74C
EXCELON 74 Micro-Fog and Oil-Fog Lubricators 3/8", 1/2", 3/4" Port Sizes q EXCELON design allows in-line or modular installation q Quick release bayonet bowl q Highly visible, prismatic liquid level indicator lens q Flow sensor design provides a nearly constant oil/air ratio over a wide range of air flows q All around (360) visibility of the sight-feed dome simplifies installation and adjustment q Modular installations with EXCELON 72, 73, and 74 series can be made to suit particular applications

Use Micro-Fog models in applications with one or more points of lubrication. Use Oil-Fog models to lubricate a single tool, cylinder, or other air driven device.

Technical Data
Fluid: Compressed air Maximum pressure: Transparent bowl: 10 bar (150 psig) Metal bowl: 17 bar (250 psig) Operating temperature*: Transparent bowl: -20 to 50C (0 to 125F) Metal bowl: -20 to 80C (0 to 175F)

Ordering Information
See Ordering Information on the following pages.

* Air supply must be dry enough to avoid ice formation at temperatures below +2C
(+35F).

ISO Symbols

Start point (i.e. minimum flow required for lubricator operation): 0,94 dm3/s (2.5 scfm) at 6,3 bar (90 psig) inlet pressure Typical flow with 6,3 bar (90 psig) inlet pressure and 0,5 bar (7 psig) pressure drop: 70 dm3/s (148 scfm) Nominal bowl size: Standard: 0,2 litre (7 fluid ounce) Optional: 1 litre (1 quart US) Manual drain connection: 1/8" Recommended lubricants: See page N/AL.8.900.935 Materials: Body: Aluminum Bowl: Transparent: Polycarbonate with steel bowl guard Metal: Aluminum Metal bowl liquid level indicator lens: 0,2 litre (7 fluid ounce): Transparent nylon 1 litre (1 quart US): Pyrex Sight-feed dome: Transparent nylon Elastomers: Neoprene and Nitrile

No Drain

With Drain

4/98

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

N/AL.8.200.400.01

L74M, L74C

Typical Performance Characteristics


FLOW CHARACTERISTICS psig bar g MICRO-FOG PORT SIZE: 1/2" bar g psig OIL-FOG PORT SIZE: 1/2" FLOW CHARACTERISTICS

10 PRESSURE DROP 0,6 8 INLET PRESSURE: bar g (psig) 2,5 4,0 (36) (58) 0,4 6,3 8,0 10,0 (90) (116) (150) PRESSURE DROP

10 0,6 8 INLET PRESSURE: bar g (psig) 2,5 4,0 (36) (58) 0,4 6,3 8,0 10,0 (90) (116) (150)

4 0,2 2

4 0,2 2

0 0 0 20 40 40 80 60 120 AIR FLOW 80 160 100 200 dm3/s scfm

0 0 0 20 40 40 80 60 120 AIR FLOW 80 160 100 200 dm3/s scfm

Ordering Information. Models listed include ISO G parallel threads, manual drain, and 0,2 litre (7 fluid ounce) metal bowl with
plastic liquid level indicator.

Main Port Size G3/8 G1/2 G3/4


*

Model Number Micro-Fog Models * L74M-3GP-QDN L74M-4GP-QDN L74M-6GP-QDN

Model Number Oil-Fog Models * L74C-3GP-QDN L74C-4GP-QDN L74C-6GP-QDN

Flow dm3/s (scfm) 50 (106) 70 (148) 70 (148)

Weight kg (lb)** 0,77 (1.70) 0,73 (1.61) 0,71 (1.55)

Models listed in the order table must not be located downstream of frequently cycling directional control valves. Order the optional bi-directional Oil-Fog Lubricator for use under such conditions. ** Lubricators with 1 litre (1 quart US) metal bowl: Add 0,91 kg (2.01 lbs). Typical flow with 6,3 bar (90 psig) inlet pressure and a pressure drop of 0,5 bar (7 psig).

Alternative Models
L 7 4 5 - 5 5 5 - 55 5
Type Oil-Fog Micro-Fog Port Size 3/8" 1/2" 3/4" Threads PTF ISO Rc taper ISO G parallel Air Flow Direction Bi-directional (Oil-Fog only) Uni-directional Substitute C M Substitute 3 4 6 Substitute A B G Substitute E P Options Low oil level switch *** None Pyrex dome * Quick fill nipple Substitute L N P Q

Bowl Substitute 1 litre (1 quart US) metal with A Pyrex liquid level indicator 0,2 litre (7 fluid oz.) metal with D plastic liquid level indicator 0,2 litre (7 fluid oz.) P transparent with guard 0,2 litre (7 fluid oz.) metal with R Pyrex liquid level indicator Drain Substitute Closed bottom E Manual 1/4 turn Q Remote fill device - Use only R with 0,2 litre (7 fluid oz.) bowl.

*** Low oil level switch requires 1 litre bowl, type A at 9th digit. * Pyrex dome used only with bowl type A or R at 9th digit. Pyrex liquid level indicator used only with option P at 10th digit.

N/AL.8.200.400.02

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

4/98

L74M, L74C

Accessories

Wall Mounting Bracket 0,2 litre bowl: 4324-50 1 litre bowl: 4324-51

Quikclamp and Quikclamp Wall Bracket 4314-52

Remote Fill 18-027-984

Quick Fill Nipple (Field Conversion) 18-011-024

Low Oil Level SwitchFor use with 1 litre bowl (Field Conversion) 18-023-610

Dimensions mm (inches)
110 (4.32) 80 (3.15) 80 (3.15) 37 (1.45) 68 (2.69)**

74 (2.89)

47 (1.86)

68 (2.69)**

25 (1.00) 283 (11.14) Closed Bottom 61 (2.40)

47 (1.86) 177 (6.95) With Drain 508 (20.00) *

* Minimum clearance to remove bowl. ** Optional pyrex sight-feed dome.

4/98

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

157 (6.18) Closed Bottom

276 (10.87) *

N/AL.8.200.400.03

303 (11.93) With Drain

25 (1.00)

L74M, L74C

Bracket Mounting
Mounting Bracket Use 5 mm (3/16") screws to mount bracket to wall.
69 (2.72)

Quikclamp and Quikclamp Wall Bracket 0,2 litre (7 fluid ounce) bowl only. Use 6 mm (7/32") screws to mount bracket to wall.
24 (0.95) A Port C L 51 (2.01)

5 (0.20)

50 (1.97)

6 (0.24)

4 (0.16)

25 37 (1.46) (1.00)

Port C L 20 (0.77)

61 (2.40)

Bracket Kit Reference


Model 0,2 litre (7 fluid oz.) bowl 1 litre (1 quart US) bowl Item Wall Bracket Quikclamp and Quikclamp Wall Bracket Wall Bracket Dimension A B 51 (2.00) 79 (3.11) Part Number 4324-50 4314-52 81 (3.17) 109 (4.29) 4324-51

Service Kits
Item Service kit Liquid level lens kit Replacement drain Type Seal & Gasket 0,2 litre (7 fluid ounce) bowl 1 litre (1 quart US) bowl Manual 1/4 turn Part Number 4382-700 4380-050 2273-22 619-50

Service kit includes dome seal, drain seal, bowl seal and fill plug seal

Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

N/AL.8.200.400.04

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

101 (3.98)

82,5 (3.25)

Port C L

4/98