Вы находитесь на странице: 1из 2

UPM3010

Power supply
Rated voltage: Frequency: Max. repetitive voltage: Max. non repetitive voltage: Consumption:

TECHNICAL SPECIFICATIONS
MEASUREMENT

INSTANTANEOUS MEASUREMENTS
UNIT SUPPLIED

65 - 265 V AC / 90 - 350 V DC or 19 - 60 VDC 45 - 65 Hz 300V 320V (20msec) 8VA max 750 VAC max L-L 1000 Vrms L-L o L-N 600 Vrms L- 2 kVrms L-L or L-N (<1 sec.) 1 kVrms L- >1.3 MOhm max 0.15 VA per phase 45 - 65 Hz 1 / 5 A programmable 20 mA / 7 A 10A continuous - 100 A for 1 sec. 0.02 Ohm approximately max 0,05 VA per phase 150 VAC max between phases 0.2% reading 0.05% full scale 0.2% reading 0.1% full scale 1% reading 0.1% full scale (PF=1) 1% reading (0.5 inductive - 0.8 capacitive) 1.5% reading (0.5 inductive - 0.8 capacitive) 0.05% reading 2 digits from 45 to 65 Hz back-lit graphic LCD 128 x 128 dots 7 push-buttons RS232 / RS485 / PRINTER configurable 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 from -5 oC to +55 oC from -15 o C to +60 o C 75% max. without condensation Metal IP50 for the front panel, IP20 for terminals plug-in type - conductors 2.5 mm 2 - rating 12 A max 144 x 144 x 118 (mm) About 1500 g.

PHASE VOLTAGE (rms) LINE VOLTAGE SYSTEM VOLTAGE LINE CURRENT SYSTEM CURRENT POWER FACTOR SYSTEM POWER FACTOR COS SYSTEM COS APPARENT POWER SYSTEM APPARENT POWER ACTIVE POWER SYSTEM ACTIVE POWER AVERAGE SYSTEM ACTIVE POWER REACTIVE POWER SYSTEM REACTIVE POWER FREQUENCY VOLTAGE THD CURRENT THD FFT ANALYSIS

VL1-N - V L2-N - V L3-N [V] VL1-L2 - VL2-L3 - VL3-L1 [V] V [V] IL1 - IL2 - IL3 [A] I [A] PFL1 - PF L2 - PF L3 PF DPF L1 - DPFL2 - DPFL3 DPF SL1 - S L2 - SL3 [VA] S [VA] PL1 - PL2 - PL3 [W] P [W] PAV [W] QL1 - QL2 - Q L3 [var] Q [var] f [Hz] THDL1 - THD L2 - THDL3 [%] THDL1 - THD L2 - THDL3 [%] [%, V, A]

UPM3010
UNIVERSAL POWER METER
l l l l l l l Typical accuracy 0.2% Modular options Large graphic display with excellent visibility Removable memory card FFT harmonic analysis EN50160 analysis 5-selectable languages

Voltage inputs
Maximum measurable voltage: Maximum continuous overload: Maximum withstandable peak: Input impedance: Burden: Frequency:

Current inputs
Rated current (Ib): Min / max measurable current: Maximum overload: Input impedance: Burden: Insulation voltage:

Typical accuracy
Voltage Current Active power Power factor Active energy Frequency

Display and operating controls


Display Keyboard

STORED DATA
SYSTEM ACTIVE ENERGY (BI-DIRECTIONAL) SYSTEM APPARENT ENERGY (BI-DIRECTIONAL) SYSTEM LAGGING REACTIVE ENERGY (BI-DIRECTIONAL) SYSTEM LEADING REACTIVE ENERGY (BI-DIRECTIONAL) TARIFF REGISTERS MIN/MAX VALUES [Wh] [VAh] [varh ind] [varh cap]

Communication port
Type Baud Rate

[Wh-VAh-varh ind-varh cap] V - V L1-N/L2-N/L3-N - I - IL1/L2/L3 - P - S - PF - PAV []

Environmental conditions
Operating temperature Storage temperature Relative humidity

PROGRAMMABLE RECORDINGS
AVERAGE POWER MIN/MAX HARMONICS SAMPLE VDROP MIN/AVG/MAX - AVAILABLE - NOT AVAILABLE - OPTIONAL

Mechanical characteristics
Material: Protection degree: Terminals: Size: Weight:

CONFIGURATION & OPTIONS


UPM3010E UPM3010STD

Digital Outputs * Digital Inputs * Analogue Outputs * External analogue outputs * Profibus * Flash card (1Mb ... 2Mb) Scope / Profile pages Harmonic analysis WFR (14 ... 500Hz) VDROP MIN/AVG/MAX - AVAILABLE - NOT AVAILABLE - OPTIONAL * maximum No. 2 options for UPM3010E - maximum No. 4 options for UPM3010STD

PROGRAMMABLE RECORDINGS
TYPE OF RECORDED DATA Basic version AVERAGE POWER MINIMUM / MAXIMUM values SAMPLES (Snapshots) HARMONICS * VOLTAGE VARIATIONS RECORDING INTERVAL 1, 5, 10, 15, 30, 60 minutes from 1 to 9999 minutes from 1 to 9999 seconds 1, 5, 10, 15, 30, 60 minutes When event occurs from 1 to 999 seconds START/STOP RECORDING (**) PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE CONTINUOUS PROGRAMMABLE RECORDED PARAMETERS Active, Reactive Inductive, Reactive Capacitive, Apparent (IMPORT/EXPORT) V; V L1-N; VL2-N; VL3-N; I; IL1; IL2; IL3; P; S; PF; PAV V; VL1-N; VL2-N; VL3-N; V L1-L2; VL2-L3; VL3-L1; I; IL1 ; IL2; IL3; IN; PF; PFL1; PFL2; PFL3; Cos; CosL1; CosL2; CosL3; S; SL1; SL2 ; SL3; P; PL1; PL2; P L3; Q; QL1 ; QL2; Q L3; F; THD-(VL1-N; VL2-N; VL3-N; IL1 ; IL2; IL3 ); PAV 1SAUUPM30102 VL1-N; VL2-N; VL3-N; IL1; I L2; IL3 VL1-N; VL2-N ; VL3-N Maximum 10 parameters to be chosen among the main parameters

Option

* MINIMUM / AVERAGE / MAXIMUM values

* The measurements are carried out with continuous sampling ** It is possible to set 10 different start/stop corresponding to 10 different recordings

Subject to change without prior notice.

UPM3010 is a panel analyser able to measure the electrical parameters on single-, two- and three-phase systems. UPM3010 offers an unprecedented flexibility and complete range of functions at a very aggressive price. UPM3010 performs the following functions: - wattmeter / energy meter - harmonics analyser - network anomalies recorder - calculation of Power Factor compensation UPM3010 can be connected to its external printer (LPR40) for data printout. UPM3010 excels at the analysis of energy quality to EN50160 standard. The instrument is manufactured in 2 versions: - UPM3010E: offers the main functions at an extremely competitive price; - UPM3010STD: can be equipped with all the available hardware and software functions and with the Flash Card Memory
Measurement inputs
UPM3010 offers total connection versatility for current and voltage measurement inputs. There are approximately seven ways of connecting the UPM3010, all of them programmable from menu pages, thus allowing measurement on three-, two- and single-phase systems.

UPM3010 's main feature is its flexibility: in the rear side of the instrument it is possible to insert up to 4 add-on option boards. The STD version can be equipped with a second processor board to perform the analysis of network quality (EN50160). Digital outputs:

HARDWARE OPTIONS

This module can be equipped with 2 or 4 isolated outputs. The digital outputs can detect when a threshold is overcome or can be used for energy pulse emission.

Number of channels ML type MH type RL type

2/4 50 VA.C./D.C. / 200mA (OPTOMOS) 250 VA.C./D.C. / 100mA (OPTOMOS) 250 V A.C. / 5A resistive (RELAY)

Analogue outputs:

UPM3010E

This module is equipped with 2 analogue outputs. The analogue outputs can be programmed as 0-20 mA or 420 mA and can be used in order to transmit a signal to an external storing device.

Number of channels Type Resolution

2 0-20 / 4-20 mA configurable (load = 300 Ohm max) 12 bit

Digital inputs:

This module is equipped with 4 isolated digital inputs. The digital inputs can be used for the acquisition of energy pulses.

Number of channels Type Max frequency

4 insulated for voltage-free contact 10Hz

Analogue inputs:

This module is suitable for mesuring the analogue signals. It is possible to read signals with slow variation: temperature, fluid flow, etc.... The module can be equipped with a sensor (rear side of the instrument) measuring the surrounding temperature.

Number of channels Additional channel Type Resolution

4 - for slow signal surrounding temperature 1V, 0-20 mA, 4-20 mA configurable 10 bit

PROFIBUS:
UPM3010STD

Profibus DP is a communication standard complying with EN50170.

Communication
UPM3010 is equipped with a RS232/RS485 serial port for the connection to a Personal Computer or other device. The same port can be set for the connection to LPR40 for data printout.

When the UPM3010STD is connected to a PC running the DEDALO software the computer will display harmonics up to 64th order and the waveform for voltage and current.

Port Transmission Number of points Baud rate Distance

RS485 asynchronous NRZ 32 each segment (99 max) from 9.6 kbaud to 12 Mbaud 100m (@ 12Mbaud)

LONBUS:

Lonbus is a communication standard developped in order to work directly with LONWORKS networks.

Baud rate Distance

9600,n,8,1 kbaud 400m without repeater

EN50160
UPM3010STD can be configured to analyse electrical energy according to EN50160 standard. Options VDROP and MIN/AVG/MAX allow the user to capture, show and analyse variations in the supply system; including transient events such as power failure, voltage sags, overvoltage and frequency changes. Event recording is triggered automatically by pre-defined events. VDROP: this option detects and records voltage anomalies in the three phase voltages to the EN50160 Standard. Sampling is continuous with a 10 ms resolution and events are recorded in the instrument memory. The software (supplied with the instrument) displays 1s before and 1s after the event (100+100 half cycles). Voltage variations can be viewed in tabular or graphical form. When the instrument is equipped with the digital outputs option, an alarm can be activated when a voltage anomaly occurs. MIN/AVG/MAX: this option records the minimum, average and maximum values of the main parameters measured by the unit. Sampling is continuous and both the time resolution (min. 20ms) and the integration time can be varied. The recorded data is viewed on the PC to the EN50160 standard.

FLASH CARD:

Power supply

The instrument can be operated from an extremely wide range of voltages (65- 265VAC / The UPM3010 has a wide range of graphic 90 - 350VDC or 19 - 60VDC) without any need for functions: waveform, Fresnel diagram, harmonic operator to change the voltage selection. content and profiles of the daily energy Very user-friendly consumption with min / max values. The user is able to select any of the five selectable Flash card Memory languages: English, German, Italian, French and UPM3010 is an extremely versatile data recorder. Spanish. It is possible to record, up to 10 different types A simple menu structure makes the instrument of measured data each with different start and easy to use and enables a quick check of the stop times (see PROGRAMMABLE instrument set-up and memory status. RECORDINGS). The display incorporates a very efficient LED The instrument is equipped with removable backlight, which guarantees perfect visibility in memory, contained in a sliding holder on the all light conditions. instruments panel. The memory is a FLASH type module with a Flexibility capacity of either 1 or 2 MB. The memory is very New functions can be retrofitted to the UPM3010. New functions are downloaded from the PC via compact only 45x15x3 mm! The removable memory allows data to be taken the serial port or by remote modem connection. away from the instrument, installed and recording This upgrade procedure makes the instrument in the field, and downloaded to a PC using the completely re-configurable and up-datable. optional flash card reader FLREAD.

Graph functions

The instrument UPM3010STD is equipped with FLASH-Type removable memory. A sliding holder for the FLASH CARD has been mounted on the instruments front panel. The FLASH CARD can be read via serial port or with the reading device FLREAD that can be connected to the parallel port of the PC . In this case the data are downloaded at higher speed than with a direct connection UPM3010/PC via serial port.

FLASH CARD: Capacity Dimension FLASH READER: PC connectio Dimension Weight

1 and 2 MB 45x15x3 mm parallel port 150x118x57 mm 250 g

External printer:

For numeric and graphic printouts. The printer can print the selected measured values at time intervals or it can trace a continuous graph of the variables.

Type Number of column Printout speed

impact on normal paper 42 1.0 line / sec.

External bus:

Module to expand the instrument's internal options even further. For instance, it is possible to connect the EM80A module with 8 analogue outputs 0-20 / 4-20 mA.

Trasmission Connection Length

synchronuos serial 4 wires 10 m maximum

Processor Board:

By mounting the second processor board the UPM3010STD is enabled to sampling of the voltage and current symultaneously. It allows to implement functions such as MIN/ AVG/MAX and VDROP specialized in the network quality analysis according to EN50160. (For the VDROP option the UPM3010 must bepowered by UPS or battery).

Measurement method RMS value calculated

continuous sampling on the three phases VDROP: every 10ms MIN/AVG/MAX: every 20ms

Flash card reader


FLREAD enables the flash card memory to be read and downloaded more quickly than with the serial connection of the UPM3010. The FLREAD is connected to the PC parallel port.

Harmonic analysis

SOFTWARE OPTIONS
Harmonic analysis:
The instrument carries out the FFT analysis up to the 31th harmonic. With the connection to the software DEDALO it is possible to display up to the 64th harmonic according to IEC 1000-4-7.

UPM3010STD can measure and record odd and even harmonics to the 31st order. Harmonics are displayed both in tabular and graphical formats with the spectrum analysis for both voltage and current. When the UPM3010STD is in VDROP or MIN/ UPM3010 calculates the THD for current and AVG/MAX modes, it still maintains the wattmeter voltage. functions as well as harmonic analysis.

Extended measurement range:

With this option the measurement range is extended: 14 to 500Hz instead of 45 to 65Hz. See the table on the following page for the base configuration of UPM3010 E and UPM3010 STD.

Вам также может понравиться