CIRCUIT-BREAKER SIZE S3, FOR MOTOR PROTECTION, CLASS 10, A-REL. 57...75A, N-REL. 975A, SCREW TERMINAL, STANDARD SWITCHING CAPACITY
IP20
3RV1041-4KA10 Page 1/ 4
04/22/2010
Mechanical switching cycle as operating period / of the main contacts / typical Type of the driving mechanism / Motor drive design of the operating mechanism Product function Overload protection Short-circuit to earth recognition Phase disturbance recognition Product component / auxiliary switch Product component / Undervoltage release mechanism Product component / trip indicator Product extension / optional / Motor drive
50,000
No selector switch
Main circuit:
Number of poles / for main current circuit Type of voltage Operating voltage / at 3 AC / rated value / maximum Operating current / at AC-3 / at 400 V / rated value Service power / at AC-3 at 400 V / rated value Switching frequency / at AC-3 / according to IEC 60947-6-2 / maximum Arrangement of electrical connectors / for main current circuit Adjustable response current of the non-delayed short-circuit release Adjustable response current of the current-dependent overload release Continuous current / rated value Product extension / auxiliary switch A A 57 75 75 Yes A 975 975 kW 1/h 37 15 V A 3 AC/DC 690 75
front side
Auxiliary circuit:
Number of NC contacts / for auxiliary contacts / instantaneous switching Number of NO contacts / for auxiliary contacts / instantaneous switching Number of change-over switches / for auxiliary contact 0
Inputs/ Outputs:
Number of digital inputs 0
Short-circuit:
Breaking capacity limit short-circuit current (lcu) at 400 V / rated value kA 50
3RV1041-4KA10 Page 2/ 4
04/22/2010
at 500 V / rated value at 690 V / rated value Design of the overcurrent release and short-circuit release
kA kA
8 5 thermomagnetic
Installation/mounting/dimensions:
built in orientation Type of fixing/fixation any screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 mm mm mm 70 165 174
Width Height Depth distance, to be maintained, to the ranks assembly backwards sidewards Product function / removable terminal for auxiliary and control circuit
mm mm
0 0 No
Connections:
Design of the electrical connection for main current circuit Type of the connectable conductor cross-section for main contacts unifilar stranded wire stranded wire with conductor end processing Conductor cross section that can be connected / for main contacts unifilar stranded wire stranded wire with conductor end processing mm 2.5 50 mm mm 2.5 16 10 70 2x (2.5 ... 35 mm2), 2.5 ... 50 mm2 2x (2.5 ... 16 mm2) 2x (10 ... 50 mm2), 10 ... 70 mm2 screw-type terminals with box terminals
Safety:
Protection against electrical shock finger-safe
Further information:
Information- and Downloadcenter (Catalogs, Brochures,) http://www.siemens.com/industrial-controls/catalogs Global Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RV1041-4KA10/all
3RV1041-4KA10 Page 3/ 4
04/22/2010
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RV1041-4KA10
last change:
3RV1041-4KA10 Page 4/ 4