The 200200 dual-input proTIM-R (DIN Rail mount) provides two channels of measurement. All acceleration-to-velocity (A-V) channels condition the signal from an accelerometer and integrate it to velocity units. The Low Frequency A-V channels are better suited for slower speed applications. A-V with Acceleration Enveloping (AE) channels provide both integrated velocity units and advanced AE signal conditioning. Temperature channel types include K-type thermocouples and 100 Platinum (Pt) RTDs with electrical isolation. Each channel is independent and specified when the proTIM is ordered. Measurement Type Acceleration-to-Velocity (General Purpose) Low Frequency Acceleration-toVelocity Acceleration-to-Velocity with AE K-type Thermocouple 2, 3, or 4 Wire Platinum RTD Interfaced Transducer 200150 200155 200157 200125* Industry standard*

*The 200125 is the recommended sensor for Trendmaster temperature measurements when the range of a K-type thermocouple is adequate. Use of other K-type thermocouples is not recommended due to the unique electrical isolation requirements of the Trendmaster system. The use of only nongrounded RTDs and non-grounded tip thermocouples to prevent ground loops is highly recommended. Failure to comply may result in NOT OK or NO DATA conditions, inaccurate readings, or proTIM-R damage. Consult the factory for further information.

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 1 of 12

Specifications
All specifications are at +25 5 C (+77 9 F) unless otherwise specified. Operation outside the specified limits will result in false or inaccurate readings. 200200 proTIM-R and 200150, 200155, 200157 or 200125 transducer systems For detailed specification on the transducers, refer to the individual transducer data sheets. Electrical: AV (General Purpose) Channels (with 200150) Measurement Range: 0 to 50 mm/s pk (0 to 2 in/s pk) Over range: 63 mm/s pk (2.5 in/s pk) Resolution: 0.025 mm/s (0.001 in/s pk) nominal Accuracy: 15% at 80 Hz Frequency Response: 10 Hz to 1 kHz (600 cpm to 60,000 cpm) 20% ( 2 dB) NOT OK Range: Open transducer signal, power, or common is Not OK. Shorted leads are Not OK except for SIG+ shorted to SIG- or common shorted to shield.

Accuracy: 15% at 80 Hz Frequency Response: 3 Hz to 1 kHz (180 cpm to 60,000 cpm) 10% ( 0.9 dB)* * The A-V circuitry attenuates frequencies above 1 kHz. Use of the 200155 transducer to obtain higher frequency information will be ineffective. NOT OK Range: Open transducer signal, power, or common is Not OK. Shorted leads are Not OK except for SIG+ shorted to SIG- or common shorted to shield.

Electrical: AV w/ AE Channels (with 200157)


Measurement Range: 0 to 50 mm/s pk (0 to 2 in/s pk) Over range: 63 mm/s pk (2.5 in/s pk) Resolution: 0.025 mm/s (0.001 in/s pk) nominal Accuracy: 15% at 80 Hz Frequency Response: A-V: 10 Hz to 10 kHz (600 cpm to 600,000 cpm) 20% ( 2.0 dB)** AE: 500 Hz to 10 kHz (30,000 cpm to 600,000 cpm) 20% ( 2.0 dB) ***
** The A-V circuitry attenuates frequencies above 1 kHz. Use of the 200157 transducer to obtain higher frequency information will be ineffective. AE signals up to 10kHz are processed at the proTIM. *** The 500 Hz filter has a 4-pole attenuation slope.

Electrical: Low Frequency AV Channels (with 200155)


Measurement Range: 0 to 50 mm/s pk (0 to 2 in/s pk) Over range: 63 mm/s pk (2.5 in/s pk) Resolution: 0.025 mm/s (0.001 in/s pk) nominal

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 2 of 12

NOT OK Range: Open transducer signal, power, or common is Not OK. Shorted leads are Not OK except for SIG+ shorted to SIG- or common shorted to shield.

Storage Temperature: -40 C to +100 C (-40 F to +212 F) Humidity: 100% non-condensing (Note: Apply DC4 grease on connecter contacts to improve environmental performance and prevent corrosion) Enclosure Type:

Electrical: Temperature Channels


Measurement Range: -18 C to +204 C (0 F to +400 F) Resolution: 0.07 C (0.12 F) Accuracy: K-Type TC: 8 C (14 F), including proTIM-R, thermocouple & lead wire error, maximum length of 6 meters. RTD: 4.45 C (8 F), RTD lead wire error not included OK Range: -31 C to +213 C (-25 F to +415 F) NOT OK Condition: Temperatures outside the OK Range Open RTD or thermocouple wires are "Not OK" Compensation Coefficient Alpha in / / C RTD: European = 0.00385 US Industrial = 0.00392 Software compensation at host computer Dimensions:

Type 4

Mechanical
Housing Material: Powder Coated Aluminum Weight: 545 grams (19 oz)

See diagram

Electromagnetic Compatibility
Radiated Emissions: EN 55011 (1998), Class A. Electrostatic Discharge: EN 61000-4-2 (1995), Criteria B. Radiated Susceptibility: EN 61000-4-3 (1996), Criteria A. Conducted Susceptibility: EN 61000-4-6 (1996), Criteria A. Electrical Fast Transient: EN 61000-4-4 (1995), Criteria A. Surge Capability: EN 61000-4-5 (1996), Criteria B.

Environmental Limits
Operating Temperature: -40 C to +85C (-40 F to +185 F)

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 3 of 12

Hazardous Area Approvals


CSA: Installed with intrinsically safe zener barriers per drawing 164160 Class I, Div 1 Groups A, B, C & D Class II, Div 1 Groups E, F & G Class III, Div 1

Intrinsically safe entity parameters: Maximum # of ProTIMs per line 32 (all gas groups) Power Supply Requirements Ui15V Ii150 mA Ci0 (negligible) Li0 (negligible)

A/Ex ia IIC; Class I, Zone 0 T4 @ Ta = -40 C to +100 C Installed without barriers per drawing 164161 Class I, Div 2 Groups A, B, C & D T4 @ Ta = -40 C to +100 C AEx nA IIC, Class I, Zone 2 T4 @ Ta = -40 C to +100 C CENELEC: Installed with intrinsically safe zener barriers per drawing 164160 II 1 G EEx ia IIC T4 @ Ta = -40 C to +100 C LCIE 03 ATEX 6459 X Installed without barriers per drawing 164161 II 3 G EEx nA II T4 @ Ta = -40 C to +100 C LCIE 03 ATEX 6460 X

Signal Terminals Ui12V Field wiring parameters: IIC IIB IIA Non-incendive (Zone 2 or Div 2) entity parameters:
Capacitanc e(F)

Ii12 mA
Inductance (mH) L/R (H/ohm)

0.09 0.705 2.23

2 8 16

16 64 130

Power Supply Requirements Un=12-15 V (nominal) In=50 mA (nominal) Maximum cable length, number of modules: Gas Group Maximum Cable Length 1000 3599 4876 Maximum Number of ProTIMs per line 125 127 127

IIC IIB IIA

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 4 of 12

200151 and 200152 Transducer Cables


Used to connect the acceleration transducers to the proTIM-R. Operating Temperature: -20 C to +100 C (-4 F to +212 F).
Note: These cables may be used at lower temperatures down to 40 C (-40 F), if the cable is not allowed to move or flex. Flexing these cables at temperatures below 20 C (-4 F) may damage them.

85033 Trendmaster SPA/TIM line cable


Use to connect a SPA to the proTIM For substitutions, reference guide 101206. Operating Temperature: -70 C to +200 C (-94 F to +392 F). Conductors: 4x 18 AWG stranded, tinned copper 1x 18 AWG stranded copper, tinned overcoat un-insulated drain wire Shielding: 100% Aluminum mylar foil out with helically applied drain wire 85% braided tinned copper Insulation: Conductors: Fluoroethylene propylene (FEP) teflon 0.25 mm (0.010 in) thick

Minimum Bend Radius: 63.5 mm (2.5 in) Construction: Four conductor (22 AWG) with foil shield and drain wire (100% coverage), polyvinyl chloride (PVC) outer jacket. Connectors: 200152 Cables: PT06F8-4S (or equivalent) on the transducer end; stripped stranded wire at proTIM end. Connector coupling nut material is -20 2011 T3 aluminum or UNFthreaded nickel-plated brass. Connector contact material is gold-plated brass. 200151 Cables: Screw-on, five-pin, keyed connector on the ProTIM-C end and a PT06F8-4S (or equivalent) on the transducer end. Connector coupling nuts for cables delivered after October 2005 consist of 20 UNF-threaded 2011 T3 aluminum or UV-stabilized black nylon. Contact material is goldplated nickel-coated brass. Classifications: Cable assembly meets UL 2238. Cable meets IP67 ingress protection Capacitance:

Outer: FEP teflon 0.38 mm (0.015 in) thick Classifications: NEC article 725 class 3 UL Listed Voltage rating: 300 Vrms

Between conductors: 131 pF/m (40 pF/ft) Between conductor and drain wire: 262 pF/m (80 pF/ft)

Ordering Information
200200-AXX-BXX-CXX Option Descriptions A: Channel A Input Option 01 Acceleration to Velocity (200150) 02 K-Type Thermocouple (200125) 03 2 or 3 Wire Pt. RTD 04 4 Wire Pt. RTD
Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 5 of 12

05 06 B:

Low Freq Accel-to-Velocity (200155) Accel to Velocity w/ AE (200157)

B:

Armor Option: 02 03 Standard cable, unarmored. Stainless steel over braid (armored) cable Standard aluminum coupling nut Nylon coupling nut Knurled aluminum coupling nut

Channel B Input Option 01 Acceleration to Velocity (200150) 02 K-Type Thermocouple (200125) 03 2 or 3 Wire Pt. RTD 04 4 Wire Pt. RTD 05 Low Freq Accel-to-Velocity (200155) 06 Accel to Velocity w/ AE (200157)
Note: BXX option availability is dependent on AXX options chosen. Not all BXX options are available with each AXX option.

C:

Nut Option: 00 02 10

Accessories
163986-01 proTIM-R Manual; Information & Installation Guide 162411 Trendmaster Pro System Manual 149831-01 Trendmaster DSM Datasheet 164045 Extra Female terminal plugs for TIM line connections. 164046 Extra Male terminal plugs for TIM line connections. 164352 T-Connector, for splitting TIM line cable into two directions. 00500128 Terminal Connector for Transducer inputs into proTIM-R 04500006 Dow Corning 4, Electrical Insulating Compound (5.3 Oz) 149326-01

C:

Approvals 00 05 CSA: Class 1 DIV 2, No Barriers ATEX: Zone 2, No Barriers Multi Approvals

Transducer cable
200152-AXX-BXX Option Descriptions For use with 200150, 200155, and 200157 A: Cable Length: 04 4.0 metre (13.1 feet) cable 15 15.0 metre (49.2 feet) cable 25 25.0 metre (82.0 feet) cable1 B: Nut Option: 00 Standard aluminum or brass coupling nut 10 Knurled aluminum or brass coupling nut
1. Not available for use with the 200155 or 200157 transducers (limited to 15 m [50 ft] max.)

Transducer cable
200151-AXX-BXX-CXX Option Descriptions For use with 200150, 200155, and 200157. NOTE: Only use the 200151 with the 200200 proTIM if using either a 142485 Housing Cable Adapter or a 141887 Conduit Cable Adapter A: Cable Length: 20 2.0 metre (6.6 feet) cable 40 4.0 metre (13.1 feet) cable 60 6.0 metre (19.7 feet) cable

The 200152 Accel cable environmental boot field installation kit contains everything needed to install the boot in the field. It includes ten sets of boots and clamps, silicone lubricant, easy-to-use installation tool, and an instruction sheet. The kit is not compatible with armored cables and only compatible with older, plastic versions of
Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 6 of 12

accelerometers; not compatible with existing stainless steel accelerometers. 85033-02-00 300 Meter (1000 ft) cable for TIM line 85033-01-00 150 Meter (500 ft) cable for TIM line 02180005 Jumper for the RTD proTIM-R terminals 85716-01 Polyester W/P Housing, Div 2, Type 4X, 2 proTIM-R Max (Fig 2) 85717-01 Polyester W/P Housing, Div 2, Type 4X, 4 proTIM-R Max (Fig 2) 88312-01 I.S. Polyester W/P Housing, Div 1, Type 4X, 4 proTIM-R Max (Fig 2) 88313-01 I.S. Polyester W/P Housing, Div 1, Type 4X, 2 proTIM-R Max (Fig 2) 88314-01 I.S. SST W/P Housing, Div1, Type 4X, 4 TIMs Max (Fig 3) 88315-01 I.S. SST W/P Housing, Div 1, Type 4X, 2 TIMs Max (Fig 3) 142485-01 Housing Cable Adapter (see Fig 4)

141887-01 Conduit Cable Adapter, Single 141887-02 Conduit Cable Adapter, Double (see Fig 5) 03817040 Bonding and ground wedge, NPT 03814237 Hub, conduit, -14 NPT 03839129 -14 NPT conduit fitting 03839240 -12 NPT cable seal; diameter 5.0 to 6.7 mm (0.20 to 0.26 in); used with 200152 cable 03839241 -12 NPT cable seal; diameter 1.9 to 3.4mm (0.07 to 0.13 in) 03839242 -12 NPT cable seal; diameter 3.4 to 5.0 mm (0.13 to 0.20 in); used with 200125 armored thermocouple 03839243 -14 NPT cable seal; diameter 6.4 to 7.9 mm (0.25 to 0.31 in) 03880243 Thread Seal for -12 NPT fittings 03840490 Square cut O-ring, for -14 NPT fittings

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 7 of 12

Dimensional Diagram
85.0 (3.35)

P/N: 200200-XX-XX-XX S/N: XXXXXXXX PHY ADDR: XXXX MFG YR: XXXX

100.9 (3.97)

79.0 (3.11)

200200 Trendmaster proTIM-R

86.2 (3.39)

43.2 (1.70)

52.9 (2.08)

Dimensions are in mm (in) 1. 2. 3. 4. Top view Side view Side view #2 Powder coated aluminum housing

Figure 1: proTIM Dimensional Diagram


Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 8 of 12

1. 2. 3.

Side View Top View If not using Quick Release, use 10-32 pan head screw (2 places)

ProTIM Enclosure Dimensions

Part number 85716-01 88313-01 (2 position) 85717-01 88312-01 (4 position)

Overall LxW 165 mm x 165 mm (6.50 in x 6.50 in) 267 mm x 216 mm (10.50 in x 8.50 in)

Mounting GxH 171 mm x 102 mm (6.75 in x 4.00 in) 273 mm x 152 mm (10.75 in x 6.00 in)

J 82.5 mm (3.25 in) 125 mm (4.94 in)

K 25.4 mm (1.00 in) 33.3 mm (1.31 in)

Q 143 mm (5.64 in) 244 mm (9.61 in)

Figure 2: Polyester Housing Dimensions

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 9 of 12

1. 2. 3.

Side View Top View 8 mm (0.31 in) dia., 4 places

NOTE: The number of clamps and the placement is shown for the large enclosure. The small enclosure has only one clamp, centered on the side opposite the hinge. Stainless Steel ProTIM Enclosure Dimensions Part number 85315-01 (2 position) 88314-01 (4 position) Overall LxW 191 mm x 176 mm (7.50 in x 6.94 in) 292 mm x 227 mm (11.50 in x 8.94 in) Mounting GxH 171 mm x 102 mm (6.75 in x 4.00 in) 273 mm x 152 mm (10.75 in x 6.00 in) Box size AxBxC 152 mm x 152 mm x 102 mm (6.00 in x 6.00 in x 4.00 in) 254 mm x 203 mm x 152 mm (10.00 in x 8.00 in x 6.00 in)

Figure 3: Stainless Steel Housing Dimensions

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 10 of 12

1. 2. 3. 4. 5. 6.

Housing cable adapter, 142485-01 200151 cable Accel to Velocity proTIM-R TIM housing 200150 accelerometer Machine casing Figure 4: Housing Cable Adapter

Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 11 of 12

1. 2. 3. 4. 5. 6. 7. 8.

To SPA TIM housing Accel to Velocity proTIM-R 200151 cable 200150 accelerometer Wiring in rigid conduit One inch conduit body near machine 141887-02 Conduit Cable Adapter Figure 5: Conduit Cable Adapter, Dual

Bently Nevada and Trendmaster are trademarks of General Electric Company. Copyright 2003. General Electric Company. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-energy.com/bently All rights reserved.
Specifications and Ordering Information Part Number 163662-01 Rev. F (04/07) Page 12 of 12

Вам также может понравиться