Вы находитесь на странице: 1из 3

THIS STANDARD IS: Updated DESIGN STANDARD

STD NO INDEX DATE OWNER PAGE

: : : : :

94-75-02 11.2.6 28 AUG 2000 9810 1 OF 3

SUBJECT PURPOSE DRAWING REMARKS NOTES:

: FABRICATION TOLERANCES AND DETAILING REQUIREMENTS FOR SHOP ASSEMBLED SUPERHEATER AND REHEATER COMPONENTS WITH HEADERS : To advise of the fabrication tolerances and detailing requirements for superheater and reheater components. : D-980-067, D-980-072 : This Standard to be effective immediately. 1. See Page 2 for Versions. 2. See Page 3 for list of Arrangement and Detail drawings.

REVIEWED BY: S. GARCIA APPROVED FOR CONTENT: W. RICE APPROVED FOR PUBLICATION: T. MISKELL

SR. ENGINEERING TECHNICIAN STANDARDS ENGINEERING 8126 MANAGER PRESSURE PART ENGINEERING - 9810 PROGRAM MANAGER STANDARDS ENGINEERING - 8126

This document contains proprietary data and shall not be reproduced or disclosed without permission of ALSTOM Power Inc.

SUBJECT:

STD. NO. : 94-75-02 INDEX : 11.2.6 DATE : 28 AUG 2000 OWNER : 9810 PAGE : 2 of 3 _____________________________________________________________________________________________________ UNITS: n ENGLISH; o METRIC; o BOTH; o NONE PRODUCT LINES: CHECK THE PRODUCT LINES THAT THE STANDARD IS APPLICABLE TO o ALL; n n o o o o A = CONTROLLED CIRC. BOILERS o B = SUPERCRITICAL BOILERS C = VU40 AND VU60 BOILERS o D = STANDARD BOILERS (D AND VP) E = FLUIDIZED BED BOILERS (CFB) n F = NATURAL CIRC. BOILERS (UTILITY) P = BOWL MILLS (PULVERIZERS) o R = CHEMICAL RECOVERY BOILERS H = HEAT RECOVERY STEAM GENERATORS (HRSG) S = SERVICES (AFTER MARKET USE)

Fabrication Tolerances and Detailing Requirements for Shop Assembled Superheater and Reheater Components With Headers

Versions Ver. 1 Revised Drawings D-980-067 and D-980-072. Ver. 2 Updated Standard format; revised Drawings D-980-067 and D-980-072.

SUBJECT:

STD. NO. : 94-75-02 INDEX : 11.2.6 DATE : 28 AUG 2000 OWNER : 9810 PAGE : 3 of 3 _____________________________________________________________________________________________________

Fabrication Tolerances and Detailing Requirements for Shop Assembled Superheater and Reheater Components With Headers

List of Arrangement Drawings Drawing No. D-980-067 Title Fabrication Tolerances and Detailing Requirements (for Two-Header Modules) for Shop Assembled Superheater and Reheater Components Fabrication Tolerances and Detailing Requirements (for Single Header Modules) for Shop Assembled Superheater and Reheater Components

D-980-072

List of Detail Drawings Drawing No. E-980-0072 Title Welded Joint Detail and Assembly for 1-1/4 to 3 Tubes Inclusive for Manual Welds