Вы находитесь на странице: 1из 34

P113145

Emergency light ttings

Presentation

Avoid public panic for greater safety


Emergency light ttings provide a sufcient lighting level in the event of mains failure. 2 mains benets for buildings occupants: Risk of panic is decreased. The path and obstacles are made visible for complete safety.

P61607

School, administration building, etc.

ELP03642

Hotel, ofce, museum, etc.

P101575

Outdoors, factory, very high warehouse, etc.

12

ISC00648_06-2009_EN

Easy to install and maintain


Special holes for fast, simplied mounting and dismounting. Quick connection by plug-in terminal board.
P101278

Design
Simple and discreet. Choice of three colours. Reinforced sealing.
P101283 P101286

Adaptable
Into emergency exit signs: enhanced with "running man" type stickers.

Intelligent
Lighting units can be deactivated during periods of building inactivity (with Teleur remote control).

Heads that can swivel in all directions. Self-diagnosis version.

Special holes.
P98735 P101284

Discreet.
P101287

P93007

Teleur

Quick connection.
P98734 P101285

Versatile.

Swivelable heads.

Sealing.

"Zoom on

"

Self-diagnosis version (Activa): Save time during test and maintenance!


Some light ttings are available in a self-test version (Domina). These devices make their operational tests. They tell whether the light source, the battery or the device is defective (and has to be replaced). The diagnosis is displayed by a diode that ashes at an appropriate rate and in an appropriate colour.

ISC00648_06-2009_EN

13

Emergency light ttings

Range overview

Range

Rilux
P93014

Primalum
P102892

Luxa
P93015

Technical specications Protection rating IP 40 Self-diagnosis Autonomy 1h b IK 06 / 07 3h b IK 06 Adptable exit sign Average ux in non-maintained mode 60 lm 65 lm 70 lm b IK 06 75 lm 90 lm b IK 06 100 lm 110 lm 115 lm 160 lm 180 lm b IK 07 210 lm 230 lm 250 lm b IK 07 370 lm Average ux in maintained mode (emergency condition) 75 lm b IK 06 90 lm 100 lm Installation methods Wall b Flush Ceiling b False ceiling 45 mounting Hanging Electried track Dimensions (mm) - h x w x (d) 6 W: 100 x 255 x (46)
P99864 P102836

IP 42 b IK 07

IP 42 or IP 65 b IK 06 / 07 b IK 06 / 07 / 08 b b IK 06 / 07

b IK 07

b IK 07 b IK 07 b IK 07 b IK 07

b IK 06 b IK 06 / 07 b IK 07 / 08 b IK 07 / 08 b IK 06 / 07

b IK 07 b IK 07

b IK 07 b IK 06 b b b b b b b b b b b b

The drawings are scale drawings

6/11W: 122 x 270 x (55)


P99867

6/11 W: 125 x 288 x (58)

8W: 100 x 331 x (46)


P99865 P99868

8 W: 135 x 348 x (58)

11/18 W: 125 x 280 x (55)


P99866

Page 14

16

20

24 ISC00648_06-2009_EN

Range

Domina
P99858

Rapida
P99859

Guardian
P93018

Technical specications Protection rating IP 42 or IP 65 Self-diagnosis b Auton omy 1h b IK 08 3h b IK 08 Adptable exit sign b Average ux in non-maintained mode 50 lm 85 lm b IK 08 90 lm 100 lm b IK 08 140 lm b IK 08 150 lm b IK 08 200 lm 210 lm b IK 08 400 lm b IK 08 640 lm b IK 08 1050 lm

IP 42 b IK 04 / 05 b b IK 04 b IK 05

IP 65 b IK 07

b IK 07 b IK 07 b IK 07 b IK 07

Average ux in maintained mode (emergency condition) 100 lm 145 lm b IK 08 Installation methods Wall Flush Ceiling False ceiling 45 mounting Hanging Electried track

b IK 05

b b b b b b

b b b b

b Horizontally or vertically

The drawings are scale drawings

Dimensions (mm) - h x w x (d) 6/11 W: 149 x 302 x (68)


P99869 P99871

6 W: 120 x 284 x (52)


P99873

2 x 10 W / 2 x 20 W: 297 x 400 x (168)

P99870

P99872

8/24 W: 169 x 382 x (82)

8 W: 120 x 360 x (52)

2 x 50 W: 280 x 440 x (230)

Page ISC00648_06-2009_EN

30

36

42 15

Emergency light ttings

Rilux
Standard version IP 40, IK 06 / 07

Good performance and attractive design at the right price!

Up to

250
P103011

lumens
P103015

P93014

3. Access from ve sides

With easy-to-drill and pre-stamped holes and 16 mm tube inlet.

16

ISC00648_06-2009_EN

1. Discrete and aesthetic design


P101283

Small and nicely shaped.

2. Fast installation
P103012 P101278

The connector is tted right from the start.

Handy: special holes for tting and removing while leaving the screw in place.
P103014

P103013

Click!!

Click!!

The connector passes through the quick mounting plate and easily clips into place.

Mechanical and electrical links are made when the unit clips into place at the last moment.

4. Easy to transform
P101286

The light tting can be transformed into an Exit sign with a set of stickers. ISC00648_06-2009_EN 17

Emergency light ttings

Rilux (cont.)
Standard version IP 40, IK 06 / 07

P93014

Technical specications
b b b b b b b b b b b Available for maintained or non-maintained operation Installation: quick mounting on wall or ceiling Compliant with EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 40, IK 06 / 07 Insulation class: II i Operating temperature: 040C Fire behaviour (EN 60695-2-10), incandescent wire: 850C Light source: uorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 24 h

Dimensions
P92716 P92718

Quick mounting 6W 8W 11/18 W 70 lm 75 and 90 lm 180 and 250 lm

Dimensions (mm) A 100 100 125 B 255 331 280 C 46 46 55 D 27 65 40 E 48 48 56

Installation methods
Wall (installation without accessories)
P92717

Ceiling (installation without accessories)

18

ISC00648_06-2009_EN

Product catalogue numbers


Rilux Protection rating Autonomy Average ux (lm) Lamp (h) emergency maintained rated socket condition mode power (W) 1 70 90 IK 07 IK 06 Maintained IP 40 IK 06 1 3 75 75 90 90 8 8 G5 G5 10.1 10.8 6.0 V 6.0 V 0.6 Ah 0.65 1.5 Ah 0.80 OVA37071E OVA37072E 3 180 250 90 6 8 11 18 8 G5 G5 2G7 2G11 G5 Consumption Ni-Cd battery (VA) Weight Cat. no. (kg)

Non-maintained IP 40
P93014

IK 06

2.5 2.5 2.9 3.0 2.7

2.4 V 2.4 V 4.8 V 7.2 V 6.0 V

1.5 Ah 0.55 1.5 Ah 0.63 1.5 Ah 0.75 1.5 Ah 0.85 1.5 Ah 0.80

OVA37066E OVA37067E OVA37069E OVA37070E OVA37068E

Accessory catalogue numbers


Compatibility Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Protective grids Rilux 6 W Rilux 8 W Rilux 11 / 18 W
P92688

Dimensions (mm) Cat. no. height x width x depth 88 x 240 88 x 316 120 x 264 88 x 240 88 x 316 120 x 264 88 x 240 88 x 316 120 x 264 88 x 240 88 x 316 120 x 264 180 x 393 x 89
OVA50236E OVA50238E OVA50240E OVA50247E OVA50249E OVA50251E OVA50248E OVA50250E OVA50252E OVA50237E OVA50239E OVA50241E OVA50343E OVA50344E

P92687

Rilux 6 W Rilux 8 W Rilux 11 / 18 W Rilux 6 W Rilux 8 W Rilux 11 / 18 W Rilux 6 W Rilux 8 W Rilux 11 / 18 W

P92690

P92689

Rilux 6 /11/18 W 170 x 333 x 89


P98698

Rilux 8 W

P93007

Teleur remote control

All models (for 100 luminaires)

102 x 77 x 81 4.5 mod. of 18 mm

OVA50325E

Spare parts catalogue numbers


Description Fluorescent tubes
P98733

P93008

Teleur 500 remote control

All models (for 500 luminaires)

90 x 71 x 60 4 mod. of 18 mm

OVA50326E

Compatibility OVA37066E OVA37067E, OVA37068E OVA37071E, OVA37072E OVA37069E OVA37070E OVA37066E, OVA37067E OVA37068E, OVA37072E OVA37071E OVA37069E OVA37070E

6 W, G5 8 W, G5 11 W, 2G7 18 W, 2G11

Cat. no. OVA51005E


OVA51006E OVA51007E OVA51009E OVA51011E OVA51012E OVA51019E OVA51018E OVA51016E OVA51021E

Batteries (Ni-Cd)
P98733

2.4 V, 1.5 Ah 6 V, 1.5 Ah 6 V, 0.6 Ah 4.8 V, 1.5 Ah 7.2 V, 1.5 Ah

ISC00648_06-2009_EN

19

Emergency light ttings

Primalum
Standard version IP 42, IK 06 / 07

Easy to install, easy to maintain. Primalum is designed in 2 parts for the ultimate in easy installation:
P106290

Light tting with all of the active elements, the reector and the diffuser.

Box with the connector.

P106296

5. Access from 5 sides


P106286 P106287

6. Maximum organization
P106289

With easy to drill pre-stamped holes and 16 tube inlet.

Cable organizer to hold the cables.

20

ISC00648_06-2009_EN

1. Fast installation
P106289 P106295 P106294

Click!!

Click!!

Can be pre-installed so that the light tting then just clicks in place.

2. Safe and easy maintenance


P106284

Click!!

Easy access to the parts thanks to the fastened diffuser.

P106285

P106288

Easy, safe battery connection, no risk.

3. Versatile: an accessory for every type of installation


P106293 P98694 P98693 P98698

For installation in false ceilings, ush-mounted, surface-mounted, in electrical conduits, etc.

4. Personalized
P106291 P106292

Straight frames in 2 colours: white and grey.

7. Easy to fasten and align


P106287 P106283

8. Secure fastening
P106282

Click!!

Several easy ways of fastening the light tting.

There is no chance of getting it wrong when joining the two parts of the light tting. 21

ISC00648_06-2009_EN

Emergency light ttings

Primalum (cont.)
Standard version IP 42, IK 06 / 07

P102892

Technical specications
b b b b b b b b b b b Available for non-maintained operation Installation: quick mounting on wall or ceiling Compliant with EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42, IK 06 / 07 Insulation class: II i Operating temperature: 040C Fire behaviour (EN 60695-2-10), incandescent wire: 850C Light source: uorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 24 h

P102896

Dimensions
P102835

18

Coloured frames (white, grey).

35

200

35

Installation methods
Wall (installation without accessories)
P102838

Dimensions (mm) A 6/11 W 65, 100 and 160 lm 122 B 270 C 55

Flush (installation with ush mounting box)

Ceiling (installation without accessories)

False ceiling (installation with false ceiling kit + ush mounting box)

Hanging (installation with hanging / electried track kit)

Electried track (installation with hanging / electried track kit)

22

ISC00648_06-2009_EN

Product catalogue numbers


Primalum Protection rating Autonomy Average ux (lm) Lamp Consumption Ni-Cd battery Weight Cat. no. (h) (kg) emergency maintained rated socket (VA) condition mode power (W) 1 65 90 115 160 220 320 3 90 6 6 6 11 11 11 6 G5 G5 G5 2G7 2G7 2G7 G5 2.5 2.5 3 4.5 3.2 3.5 3.5 2.4 V 2.4 V 4.8 V 4.8 V 6V 6V 6V 1.5 Ah 0.55 1.5 Ah 0.63 1.5 Ah 0.84 1.5 Ah 0.75 1.5 Ah 0.92 2.2 Ah 0.94 2.2 Ah 0.92 OVA37037E OVA37074E OVA37075E OVA37039E OVA37077E OVA37078E OVA37076E

Non-maintained IP 42 IK 07
P102892

Spare parts catalogue numbers


Description Fluorescent tubes
P98733

Accessory catalogue numbers


Compatibility Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Dimensions (mm) Cat. no. height x width x depth
OVA50284E

Compatibility Cat. no. OVA37037E, OVA51005E OVA37074E, OVA37075E, OVA37076E

6 W, G5

Primalum 6/11 W 108 x 255


P92687

11 W, 2G7

Batteries (Ni-Cd)
P98733

2.4 V, 1.5 Ah 3.6 V, 1.5 Ah 4.8 V, 1.5 Ah 6 V, 2.2 Ah

OVA37037E, OVA51012E OVA37074E, OVA51013E OVA37039E, OVA51016E OVA37075E OVA37076E, OVA51038E OVA37078E

P92690

P92689

OVA37039E, OVA51009E OVA37077E, OVA37078E

P92688

Primalum 6/11 W 108 x 255

OVA50285E

Primalum 6/11 W 108 x 255

OVA50286E

Primalum 6/11 W 108 x 255 EN language Primalum 6/11 W 108 x 255 ES language

OVA50287E OVA50288E

P99857

False ceiling kit (also order a ush mounting box) Hanging / electried track kit

P102895

Flush mounting box

Primalum 6/11 W 138 x 312 x 56

OVA53033E

All models
P98693

OVA53023E

All models
P98694

OVA50347E

Frames
P102894

Primalum 6/11 W White 155 x 328 x 8 Primalum 6/11 W Grey 155 x 328 x 8

OVA53028E OVA53029E

P98698

Protective grids

Primalum 6/11 W 170 x 333 x 89

OVA50343E

Teleur remote control

All models (for 100 luminaires) All models (for 500 luminaires)

P93007

102 x 77 x 81 4.5 mod. of 18 mm

OVA50325E

90 x 71 x 60 4 mod. of 18 mm

OVA50326E

ISC00648_06-2009_EN

23

Emergency light ttings

Luxa
Standard version IP 42 / IP 65, IK 06 / 07 / 08

Wide range.
Luxa has many options so it is suitable for any type of installation:
P106275

Sealed version IP 65 and unsealed version IP42. Permanent or Not Permanent. Battery operation for 1 or 3 hours. From 60 to 370 lumens.

5. Quality materials
P106272

P106280

6. Easy to fasten
P106271 P106270

7. Easy access

Polycarbonate (PC) used in all of the plastic parts. A sturdy product.

Various options for fastening the light tting.

Quality pre-stamped holes that are easy to drill through. 16 or 20 tube inlet, to IP standards. ISC00648_06-2009_EN

24

1. Easy installation
P106277 P106278 P93015

Separate connector for fast, easy connection.

2. Safe and easy maintenance


P106273 P106274

Click!!

Click!!

Easy access to the parts as the uorescent tube and the battery are incorporated in one piece.

3. Versatile: an accessory for every type of installation


P98694 P98693 P101280 P106279 P92991

Accessories for installing the light tting in false ceilings, in electrical conduits, ush-mounted, surface-mounted, etc. Converts to an emergency illuminated sign.

4. Personalized
P106276

8. Sealed version
P106269

Curved frames available in 4 colours: black, white, grey and aluminium.

For places that need installation that is protected from moisture (car park for example). ISC00648_06-2009_EN 25

P106247

Emergency light ttings

Luxa (cont.)
Standard version IP 42 / IP 65, IK 06 / 07 / 08

Technical specications
b b b b b b b b b b b b Available for maintained or non-maintained operation Installation for ush mounting and false ceiling Personalized with coloured frames Compliant with EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42 or IP 65, IK 06 / 07 / 08 Insulation class: II i Operating temperature: 040C Fire behaviour (EN 60695-2-10), incandescent wire: 850C Light source: uorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 12 h for models with 1 h autonomy

P92991-P106279

P93015

Dimensions
P92692

Coloured frames (black, white, grey, aluminium).

Installation methods
Dimensions (mm)
P92702

Wall (installation without accessories)

A 6/11 W 8W 60, 115 and 180 lm 90, 100, 210 and 370 lm 125 135

B 288 348

C 58 58

D 102 73

E 84 200

Flush (installation with ush mounting box)

Ceiling (installation without accessories)

False ceiling (installation with false ceiling kit + ush mounting box)

Hanging (installation with hanging / electried track kit)

Electried track (installation with hanging / electried track kit)

26

ISC00648_06-2009_EN

Product catalogue numbers


Luxa Protection rating Autonomy Average ux (lm) Lamp Consumption Ni-Cd battery (h) emergency maintained rated socket (VA) condition mode power (W) 1 60 100 IK 07 IK 06 IK 06 IK 07 IP 65 IK 07 IK 08 IK 07 IK 07 IK 08 Maintained IP 42 IP 65 IK 06 IK 07 1 3 1 100 90 100 185 165 185 8 8 8 G5 G5 G5 10.5 10 10.5 3.6 V 7.2 V 3.6 V 1.5 Ah 0.90 1.5 Ah 1.10 1.5 Ah 0.92 OVA37096E OVA37097E OVA37099E 3 1 3 180 210 370 60 90 115 60 100 180 210 370 60 115 6 8 11 8 8 6 8 11 6 8 11 8 8 6 11 G5 G5 2G7 G5 G5 G5 G5 2G7 G5 G5 2G7 G5 G5 G5 2G7 5 5 5 5 6.5 5 5 5 5 5 5 5 6.5 5 5 2.4 V 3.6 V 4.8 V 6.0 V 8.4 V 6.0 V 4.8 V 6.0 V 2.4 V 3.6 V 4.8 V 6.0 V 8.4 V 6.0 V 6.0 V Weight Cat. no. (kg)

Non-maintained IP 42
P93015

IK 06

1.5 Ah 0.85 1.5 Ah 0.90 1.5 Ah 0.98 1.5 Ah 0.97 1.5 Ah 1.10 1.5 Ah 1.05 2.2 Ah 0.97 2.2 Ah 1.05 1.5 Ah 0.87 1.5 Ah 0.92 1.5 Ah 1.00 1.5 Ah 0.99 1.5 Ah 1.12 1.5 Ah 1.07 2.2 Ah 1.07

OVA37191E OVA37093E OVA37192E OVA37100E OVA37095E OVA37193E OVA37094E OVA37194E OVA37195E OVA37098E OVA37196E OVA37101E OVA37102E OVA37197E OVA37198E

ISC00648_06-2009_EN

27

Emergency light ttings

Luxa (cont.)
Standard version IP 42 / IP 65, IK 06 / 07 / 08

Accessory catalogue numbers


Compatibility Dimensions (mm) Cat. no. height x width x depth 116 x 284 126 x 342 116 x 284 126 x 342 116 x 284 126 x 342 116 x 284 116 x 284 126 x 342 126 x 342 114 x 272 x 56 124 x 332 x 56 OVA50242E OVA50244E OVA50253E OVA50255E OVA50254E OVA50256E OVA50243E OVA50279E OVA50245E OVA50280E OVA50345E OVA50346E

Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10)

P92687

Luxa 6/11 W Luxa 8 W Luxa 6/11 W Luxa 8 W Luxa 6/11 W Luxa 8 W Luxa 6/11 W EN language Luxa 6/11 W ES language Luxa 8 W EN language Luxa 8 W ES language

P99857

P92690

P92689

P92688

P93016

Flush mounting box

Luxa 6/11 W Luxa 8 W

False ceiling kit (also order a ush mounting box) Hanging / electried track kit

P98693

All models

OVA50348E

Frames

P98695

P98694

All models

OVA50347E

Luxa 6/11 W Luxa 8 W Luxa 6/11 W Luxa 8 W Luxa 6/11 W Luxa 8 W Luxa 6/11 W Luxa 8 W

White 141 x 307 x 26 White 154 x 367 x 26 Black 141 x 307 x 26 Black 154 x 367 x 26 Grey 141 x 307 x 26 Grey 154 x 367 x 26 Aluminium 141 x 307 x 26 Aluminium 154 x 367 x 26 170 x 333 x 89 180 x 393 x 89

OVA50349E OVA50352E OVA50351E OVA50354E OVA50350E OVA50353E OVA53036E OVA53037E OVA50343E OVA50344E

P98698

Protective grids

Luxa 6/11 W Luxa 8 W

P101280

Exit sign kits

Luxa 8 W Pictograms provided 144 x 270

Ceiling mounting Flag mounting Wall mounting

OVA50328E OVA50329E OVA50330E

Teleur remote control

All models (for 100 luminaires) All models (for 500 luminaires)

P93007

102 x 77 x 81 4.5 mod. of 18 mm 90 x 71 x 60 4 mod. of 18 mm

OVA50325E

OVA50326E

28

ISC00648_06-2009_EN

Spare parts catalogue numbers


Description Fluorescent tubes
P98733

Compatibility OVA37191E, OVA37195E OVA37193E, OVA37197E OVA37093E, OVA37094E, OVA37098E OVA37100E, OVA37101E OVA37096E, OVA37097E, OVA37099E OVA37095E, OVA37102E

Cat. no. OVA51005E OVA51037E OVA51006E OVA51043E OVA51007E OVA51008E OVA51010E OVA51044E OVA51012E OVA51013E OVA51016E OVA51017E OVA51019E OVA51038E OVA51021E OVA51022E OVA50283E

6 W, G5 8 W, G5

11 W, 2G7 Batteries (Ni-Cd) 2.4 V, 1.5 Ah 3.6 V, 1.5 Ah 4.8 V, 1.5 Ah 4.8 V, 2.2 Ah 6.0 V, 1.5 Ah 6.0 V, 2.2 Ah 7.2 V, 1.5 Ah 8.4 V, 1.5 Ah Pictogram sticker set (4 pictograms for exit signs kit)
P92687

OVA37192E, OVA37196E OVA37194E, OVA37198E OVA37191E, OVA37195E OVA37093E, OVA37096E, OVA37098E, OVA37099E OVA37192E, OVA37196E OVA37094E OVA37100E, OVA37101E, OVA37193E, OVA37197E, OVA37194E, OVA37198E OVA37097E OVA37095E, OVA37102E
P92688

P98733

+
P92689 P92689

ISC00648_06-2009_EN

29

Emergency light ttings

Domina
Self-diagnosis version (Activa) IP 42 / IP 65, IK 08

The self-testing light tting.


P106258

A light tting that provides information on how it is working, giving its status and, if there is a fault, the cause of the fault.

P106259

5. Self-diagnosis
P106255

Self-testing light tting that performs two types of diagnosis on one LED: 1. Tube verication. 2. Battery life check.

30

P106254

ISC00648_06-2009_EN

1. Quick installation
P106249 P106250 P106251

Separate connector, safe and easy clip-on tting.

2. Safe and easy maintenance


P106252 P106253

Click!!

Easy access to the parts because the tube and the battery are incorporated in the actual reector which can easily be removed.

3. Versatile: an accessory for every type of installation


P98694 P98693 P98698 P101280

The Domina model has various accessories for installing the light tting in false ceilings, in electrical conduits, ush-mounted, surface-mounted, etc. Converts to an illuminated sign with an optional accessory.

4. Remote control (optional)


P106281

- Self-diagnosis synchronization. - Immediate test enable / disable.

6. Pre-stamped holes for easy access


P106256 P106248

7. Sealed version

Pre-stamped holes that are easy to drill through and 16 or 20 tube inlet. ISC00648_06-2009_EN

For places that need installation that is protected from moisture. 31

P106257

Emergency light ttings

Domina (cont.)
Self-diagnosis version (Activa) IP 42 / IP 65, IK 08

Technical specications
b b b b b b b b b b b b Self-diagnosis version (Activa) Available for maintained or non-maintained operation Installation for ush mounting and false ceiling Compliant with EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42 or IP 65, IK 08 Insulation class: II i Operating temperature: 040C Fire behaviour (EN 60695-2-10), incandescent wire: 850C Light source: uorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 12 h for models with 1 h autonomy

P99858

Dimensions
P106423

Dimensions (mm) A 6/11 W 8/24 W 100, 140 and 210 lm 149 85, 145, 150, 400 and 169 640 lm B 302 382 C 68 82 D 91 81 E 120 220

Installation methods
P99863

Wall (installation without accessories)

Flush (installation with ush mounting box)

Ceiling (installation without accessories)

False ceiling (installation with false ceiling kit + ush mounting box) Hanging (installation with hanging / electried track kit) Electried track (installation with hanging / electried track kit)

32

ISC00648_06-2009_EN

Product catalogue numbers


Domina Protection rating Autonomy Average ux (lm) Lamp Consumption Ni-Cd battery (h) emergency maintained rated socket (VA) condition mode power (W) 1 100 140 150 210 400 640 3 IP 65 IK 08 1 85 100 140 150 210 400 640 3 Maintained IP 42 IP 65 IK 08 IK 08 1 1 145 145 240 240 8 8 G5 G5 4.4 4.4 4.8 V 4.8 V 1.5 Ah 0.94 1.5 Ah 0.94 OVA37214E OVA37220E 85 6 6 8 11 24 24 8 6 6 8 11 24 24 8 G5 G5 G5 2G7 2G11 2G11 G5 G5 G5 G5 2G7 2G11 2G11 G5 3.9 3.9 4.4 5.5 6.9 6.9 3.7 3.9 3.9 4.4 5.5 6.9 6.9 3.7 4.8 V 4.8 V 4.8 V 6.0 V 6.0 V 6.0 V 9.6 V 4.8 V 4.8 V 4.8 V 6.0 V 6.0 V 6.0 V 9.6 V Weight Cat. no. (kg)

Non-maintained
P99858

IP 42

IK 08

1.5 Ah 0.90 1.5 Ah 0.90 1.5 Ah 0.90 1.5 Ah 1.00 4.0 Ah 2.04 4.0 Ah 2.04 1.5 Ah 1.30 1.5 Ah 0.90 1.5 Ah 0.90 1.5 Ah 0.90 1.5 Ah 1.00 4.0 Ah 2.04 4.0 Ah 2.04 1.5 Ah 1.30

OVA37226E OVA37212E OVA37213E OVA37216E OVA37224E OVA37217E OVA37215E OVA37227E OVA37218E OVA37219E OVA37222E OVA37225E OVA37223E OVA37221E

ISC00648_06-2009_EN

33

Emergency light ttings

Domina (cont.)
Self-diagnosis version (Activa) IP 42 / IP 65, IK 08

Accessory catalogue numbers


Compatibility Dimensions (mm) Cat. no. height x width x depth 130 x 227 150 x 310 130 x 227 150 x 310 130 x 227 150 x 310 130 x 227 130 x 227 150 x 310 150 x 310 152 x 295 x 50 172 x 375 x 57 OVA50267E OVA50272E OVA50268E OVA50273E OVA50269E OVA50274E OVA50270E OVA50271E OVA50275E OVA50276E OVA53021E OVA53022E

Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10)

P92687

Domina 6/11 W Domina 8/24 W Domina 6/11 W Domina 8/24 W Domina 6/11 W Domina 8/24 W Domina 6/11 W EN language Domina 6/11 W ES language Domina 8/24 W EN language Domina 8/24 W ES language

P93016

Flush mounting box

P99857

P92690

P92689

P92688

Domina 6/11 W Domina 8/24 W

False ceiling kit (also order a ush mounting box) Hanging / electried track kit

All models
P98693

OVA53023E

P98698

Protective grids

P98694

All models

OVA50347E

Domina 6/11 W Domina 8/24 W

196 x 346 x 98 226 x 436 x 110

OVA53019E OVA53020E

P101280

Exit sign kits

Domina 8/24 W Pictograms provided 130 x 336

Ceiling mounting Flag mounting Wall mounting

OVA53024E OVA53025E OVA53026E

Teleur remote control

All models (for 100 luminaires) All models (for 500 luminaires)

P93007

102 x 77 x 81 4.5 mod. of 18 mm 90 x 71 x 60 4 mod. of 18 mm

OVA50325E

OVA50326E

34

ISC00648_06-2009_EN

Spare parts catalogue numbers


Description Fluorescent tubes
P98733

Compatibility OVA37212E, OVA37218E, OVA37226E, OVA37227E OVA37214E, OVA37220E OVA37213E, OVA37215E, OVA37219E, OVA37221E

Cat. no. OVA51037E OVA51007E OVA51041E OVA51009E OVA51042E OVA51016E

6 W, G5 8 W, G5

11 W, 2G7 24 W, 2G11 Batteries (Ni-Cd)


P98733

OVA37216E, OVA37222E OVA37217E, OVA37223E, OVA37224E, OVA37225E OVA37212E, OVA37213E, OVA37214E, OVA37018E, OVA37219E, OVA37220E, OVA37226E, OVA37227E OVA37216E, OVA37222E OVA37217E, OVA37223E, OVA37224E, OVA37225E OVA37215E, OVA37221E
P92688

4.8 V, 1.5 Ah

6.0 V, 1.5 Ah 6.0 V, 4.0 Ah 9.6 V, 1.5 Ah


P92687

OVA51019E OVA51039E OVA51040E OVA50277E

Pictogram sticker set (4 pictograms for exit signs kit)

+
P92689 P92689

ISC00648_06-2009_EN

35

Emergency light ttings

Rapida
Standard version IP 42, IK 04 / 05

Quick installation, maximum integration.


Thanks to its removable base section and even design.
P106322

5. Quality design
P106318

P106324

6. Easy to fasten and align


P106316

Diffuser specically designed to achieve better quality illumination. The diffuser and the reector have been developed to obtain greater luminous efciency. 36

Several easy ways of fastening the light tting and a wide horizontal and vertical cut-out for correct alignment. ISC00648_06-2009_EN

1. Fast, easy installation


P106316 P106312 P106313

Click!!

Connectors integrated in the base section.

Maximum speed, just one click and the base section and lamp are joined together.

2. Safe and easy maintenance


P106319 P106320

Click!!

Easy access to the parts as the various elements are easy to remove.

P106321

Safe and easy battery connection.

3. Versatile: an accessory for every type of installation


P102897 P98698 P102898 P102832

Accessories for installing the light tting in false ceilings, surface-mounted, ush-mounted, ag, etc. Converts to an illuminated sign using methacrylate diffusers which are visible from 30 m.

4. Perfect integration, sophisticated design


P106323 P106315

Its smooth, straight lines allow attractive integration in the most exacting surroundings.

7. Connection without any obstacles


P106317 P106314

8. Adapter, easy access

Separate base section for easy connection.

The light tting includes an accessory for tting a 16 or 20 tube.

ISC00648_06-2009_EN

37

Emergency light ttings

Rapida (cont.)
Standard version IP 42, IK 04 / 05

P99859

Technical specications
b b b b b b b b b b b Available for maintained or non-maintained operation Installation: quick mounting on wall or ceiling Compliant with EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42, IK 04 / 05 Insulation class: II i Operating temperature: 040C Fire behaviour (EN 60695-2-10), incandescent wire: 850C Light source: uorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 12 h

Dimensions
P106424

Dimensions (mm) A 6W 8W 50 lm 90 and 100 lm 120 120 B 284 360 C 52 52

Installation methods
P99862

Wall (installation without accessories)

Flush (installation with ush mounting box)

Ceiling (installation without accessories)

False ceiling (installation with false ceiling kit + ush mounting box)

38

ISC00648_06-2009_EN

Product catalogue numbers


Rapida Protection rating Autonomy Average ux (lm) Lamp Consumption Ni-Cd battery Weight Cat. no. (h) (kg) emergency maintained rated power socket (VA) condition mode (W) 1 50 90 1 100 190 6 8 8 G5 G5 G5 4.5 4.5 4.5 2.4 V 3.6 V 3.6 V 1.5 Ah 0.80 1.5 Ah 0.85 1.5 Ah 0.90 OVA37576E OVA37577E OVA37578E

Non-maintained
P99859

IP 42

IK 04 IK 05

Maintained IP 42 IK 05

ISC00648_06-2009_EN

39

Emergency light ttings

Rapida (cont.)
Standard version IP 40, IK 04 / 05

Accessory catalogue numbers


Compatibility Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10)
P92687

Dimensions (mm) Cat. no. height x width x depth 106 x 274 106 x 350 106 x 274 106 x 350
OVA50257E OVA50262E OVA50258E OVA50263E

Rapida 6 W Rapida 8 W Rapida 6 W Rapida 8 W

P92689

P92688

Rapida 8 W Rapida 6 W EN language Rapida 6 W ES language Rapida 8 W EN language Rapida 8 W ES language

106 x 350 106 x 274 106 x 274 106 x 350 106 x 350
147 x 329 x 52 147 x 405 x 52

OVA50264E OVA50260E OVA50261E OVA50265E OVA50266E OVA53014E OVA53015E

Flush mounting and false ceiling kit

P99857

P92690

Rapida 6 W
P102897

Rapida 8 W

Protective grids for ush mounting

P98698

Rapida 6 W Rapida 8 W

201 x 364 x 41 201 x 443 x 41

OVA53012E OVA53013E

Protective grids for wall mounting

P98698

Rapida 6 W Rapida 8 W

170 x 333 x 89 180 x 393 x 89

OVA50343E OVA50344E

Exit sign kits (visibility 30 m)

P102832

Rapida 8 W

Left and right Down

OVA53016E OVA53017E

Exit sign kit (visibility 23 m)

P102898

Flag type bracket

P102833

Rapida 8 W

Left + right + down

OVA53018E

OVA53016E, OVA53017E, OVA53018E

OVA53027E

Teleur remote control

All models (for 100 luminaires) All models (for 500 luminaires)

P93007

102 x 77 x 81 4.5 mod. of 18 mm

OVA50325E

90 x 71 x 60 4 mod. of 18 mm

OVA50326E

40

ISC00648_06-2009_EN

Spare parts catalogue numbers


Description Fluorescent tubes
P98733

Compatibility OVA37576E OVA37577E OVA37578E

Cat. no. OVA51037E OVA51043E OVA51007E

6 W, G5 8 W, G5

P98733

Batteries (Ni-Cd)

2.4 V, 1.5 Ah 3.6 V, 1.5 Ah

OVA37576E OVA37577E, OVA37578E

OVA51012E OVA51013E

P92687

P92688

Pictogram sticker set (4 pictograms for exit signs kit OVA53018E)

OVA50278E

+
P92689 P92689

ISC00648_06-2009_EN

41

Emergency light ttings

Guardian
Standard version IP 65, IK 07

Security guard in large spaces.


High power and luminosity for buildings with high roofs. Fully recharged in 12 hours.

P106302

5. Halogen lighting
P106299

Provides up to 1050 lumens with two high performance halogen beams.

6. Adjustable beams
P106300

Two individually adjustable beams. Each halogen lamp turns around its axis from 90 to 45 so that they can be turned in any direction, both horizontal and vertical.

42

P106299

ISC00648_06-2009_EN

1. Reliable installation
P106303 P106304

Easy to connect and t.

2. Easy to maintain
P106298 P106297

Easy to maintain and replace parts.

3. Extremely robust to provide a high level of protection


P106301 P101285

Ready for installation outside: IP 65. Robust: IK 07.

4. Just one set


P101279

The spotlight includes a mount for upright installation.

ISC00648_06-2009_EN

43

Emergency light ttings

Guardian (cont.)
Standard version IP 65, IK 07

Technical Specications
b Provided with 2 searchlights with halogen bulbs with high lighting performance (up to 1050 lm) b The searchlights rotate on their axis from 90 to 45 for pointing in any direction b Non-maintained emergency luminaires b Compliant with EN 60598-2-22 standard b Can be inhibited with rest mode via Teleur range of remote controls b Protection rating: IP 65, IK 07 b Insulation class: II i b Operating temperature: 040C b Fire behaviour (EN 60695-2-10), incandescent wire: 850C b Power supply: 230 V, 50 Hz b Complete recharge in 12 h
P93018

Dimensions
P92728 P92693

The searchlights are vertically and horizontally adjustable.


2 x 10 W 2 x 20 W 2 x 50 W 200 lm 400 lm 1050 lm

Dimensions (mm) A 297 297 280 B 400 400 440 C 168 168 230

Installation methods
P101279

Wall (vertically) (installation without accessories)

Wall (horizontally) (installation with support non provided)

44

ISC00648_06-2009_EN

Product catalogue numbers


Guardian Protection rating Non-maintained
P93018

Average ux (lm) Lamp rated power (W) socket 1 200 400 1050 2 x 10 2 x 20 2 x 50 G4 G4

Consumption Pb battery (VA)

Weight Cat. no. (kg)

IP 65

IK 07

30 27

6.0 V 12 V

7.2 Ah 3.40 7.2 Ah 4.60

OVA41437E OVA41435E OVA41436E

GY6.35 37

2 x 12 V 7.2 Ah 7.50

Accessory catalogue numbers


Compatibility Protective grid (2 parts) All models
P98729

Dimensions (mm) Cat. no. height x width x depth 118 x 118 x 20 OVA50342E

P93007

Teleur remote control

All models (for 100 luminaires) All models (for 500 luminaires)

102 x 77 x 81 4.5 mod. of 18 mm 90 x 71 x 60 4 mod. of 18 mm

OVA50325E

OVA50326E

Spare parts catalogue numbers


Compatibility Lamps
P101289

Description 6 V, 10 W 12 V, 20 W 12 V, 50 W 6 V, 7.2 Ah 12 V, 7.2 Ah

Cat. no. OVA51002E OVA51003E OVA51004E OVA51025E OVA51024E

OVA41437E OVA41435E OVA41436E OVA41437E OVA41435E, OVA41436E

P101288

Batteries (Pb)

ISC00648_06-2009_EN

45

Вам также может понравиться