Вы находитесь на странице: 1из 69

Honeywell

IQ 3 Controller Overview

Course Objective

Honeywell

Introduction Hardware Ethernet Network Configuration Setup Portable Display Panel Supervisor Software Interface Field devices

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

INTRODUCTION

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet TCP/IP Networks


Introduction to TCP/IP

Honeywell

Ethernet TCP/IP is a suite of protocols Original intent of development was to have multiple routes which could be used by computers communicating with each other. Developed by the US Department of Defence in 1973, mainly for the purpose of interconnecting different brands of computers. TCP/IP is a non- proprietary product and is now the accepted communication protocol on the Internet For more details on TCP/IP, visit the following website:

http://www.cisco.com

TCP = Transmission Control Protocol IP = Internet Protocol

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND Ethernet TCP/IP Networks


Why TCP/IP network ?
Market Factor

Honeywell

Demand for simple and fast information access WWW becoming de-facto standard for B2B connectivity Total data connectivity (http, xml,.etc) Distribution of live information (mobile devices etc.) Open solution with lowest proprietary content (harness the IT and Web world of solutions) Increasing regulations Energy issues (Part L, Carbon taxes, cost volatility, etc.) requiring control solutions Changing building infrastructure On-line buildings linked directly to the Internet Flood-wired Ethernet networks becoming standard inside buildings

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet TCP/IP Networks


Why TCP/IP network ?
Employing Ethernet in Building Solution

Honeywell

IT / Web-based technology is widely implemented all over the world. Most widely used OPEN protocol network. Even more popular than BACnet, LONwork, MODbus, etc. Make use of building or structure existing IT backbone setup. Reduce cost and installation works. The smartest and best cost means of liberating field data for both operators and other information systems. Move away from expensive but slow Lease Line. Move away from a typical Building Management System network. No need of expensive software or specialised hardware for remote access. Using commonly available web-browser for access such as INTERNET EXPLORER

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet TCP/IP Networks


Why TCP/IP network ?
Advantages

Honeywell

Web enabled: Makes it easy to access and control the building, in real-time, from a standard Web browser Managers and operators can remotely; find out whats going on in their buildings, take rapid action to help manage costs, correct comfort problems, etc.

WWW

From anywhere, ... at anytime

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet TCP/IP Networks


TREND Strategy..
Creating a Web-based Technology System Web-

Honeywell

IT level

Use IP networking as far down the system as is economically viable Build native embedded web-serving capability as far down the system as is economically viable And ultimatelyManagement and IT level communications in IT compatible formats

Management level Control level Field level

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


INTRODUCTION
IQ 3 XCITE : WHAT IS IT ?

Honeywell

A new platform controller

Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere. Built- webBuilt-in web-server, no proprietary software required to access controller or view user specified web pages Modular Hardware Extendibility and Flexibility, up to 96 Input / Output points Flexible number of strategy modules Controllers optimised to application DIN Rail Mounted Backward compatibility with predecessor controllers IQ2 series of controller

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Types of TREND IQ 3xx Controller :
(A) IQ 3Xact Series
Controller IQ3xact/12 IQ3xcite/16

Honeywell

Inputs & Outputs 6 Analogue outputs & 6 Universal inputs 6 Analogue outputs & 10 Universal inputs only 6 Analogue outputs & 10 Universal inputs Plus up to 80 extra points via I/O expansion modules

TREND IQ 3Xact Controller

IQ3xcite/96

(B) IQ 3Xcite Series

TREND IQ 3Xcite Controller Non-Expandable

TREND IQ 3Xcite Controller Expandable


B U I L D I N G S Y S T E M S

10

N O V A R

I N T E L L I G E N T

File Number

TREND IQ 3xx Series Controller


TREND IQ 3Xcite Expandable CONTROLLER
Input / Output Modules :

Honeywell

Modules is connected via a rigid connector or Belden cable 3084A for up to 30 metres Maximum up to 15 boards can be fitted, limited to an additional of 80 Input / Output points The following module board are available :

Note Xcite 16DI module and Xcite 8DI module can accept both voltage free contact and 24 Vac supply.

11

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND Ethernet System


System Architecture :

Honeywell

3 Levels Hierarchy

TREND Supervisor Software

Management Level Field Controller Level Field Devices Level

Management / Integration Level

Peer-toPeer-to-Peer, Distributed System

TREND IQ 3xx Controller

Intelligence in Every Controller


Network or Standalone Operation Compatible with Standard Protocols BACnet/IP LONworks Open Protocol Communication (OPC)
N O V A R I N T E L L I G E N T

DDC / Field Controller Level

TREND Devices Sensors

Actuators

Field Devices Level

12

B U I L D I N G

S Y S T E M S

File Number

Introduction to TREND IQ 3XCITE Controller Honeywell


IQ 3XCITE FEATURES
Standard TREND IQ Controller Features

Ethernet Platform

BuiltBuilt-in microprocessor, intelligence in every controller. MCF 5272 microprocessor, speed 66MHz Memory 16 Mbytes SDRAM & 8 Mbytes Flash Built-in Real Time Clock BuiltNo replaceable fuse required. Protected by a self resetting thermal solid state breaker Auto-restart capabilities AutoPeer-toPeer-to-Peer Controller Share Global Data among the Ethernet network

IQ 3XCITE

IQ 3XCITE

Network or stand-alone operation stand Ideal for individual or small equipment application for stand-alone operation stand Able to support up to more than 13,400 controllers in a single network, sufficient for large building services or application.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S

13

File Number

Introduction to TREND IQ 3XCITE Controller Honeywell


IQ 3XCITE FEATURES
Standard TREND IQ Controller Features

Fully programmable to suit different application Proportional Integral Derivatives Control Boolean Algebraic & Logic Module Function Modules Optimisation Start/Stop Control Plant Rotation / Duty Cycling Sequential Control Etc. Optional Portable Display Panel Smart Display Panel (SDU) IQVIEW (Network Display Panel)

IQVIEW

SMART DISPLAY UNIT

14

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Introduction to TREND IQ 3XCITE Controller Honeywell


IQ 3XCITE FEATURES
Standard TREND IQ Controller Features

Comply to Different Standards UL Listed Standard (24 Vac) EN Standards (100 230Vac) BSI Standard : BS EN ISO 9001:2000 CE Certified Electromagnetic Compatibility Directive (89/336/EEC) Low Voltage Directive (73123/EEC)

15

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Introduction to TREND IQ 3XCITE Controller Honeywell


IQ 3XCITE FEATURES
Additional Features

Faster Network speed Ethernet 10 Base T Network Network baud rate up to 10 Mbytes/sec No memory battery back-up required. back All strategy and data stored in non-volatile memory nonBuiltBuilt-in Web browser Capability

Use commonly available web-browser for access web-

16

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Introduction to TREND IQ 3XCITE Controller Honeywell


IQ 3XCITE FEATURES
Additional Features

Individual Time Scheduling capabilities Allow more than 5 time zones per controller Unlimited number of switching per 24 hours duration period Incorporate override facilities for special events

Enhance security features More than 6 user can be set up Maximum up to 99 access level Support alphanumeric password up to 30 characters Automatic sign-off capabilities

17

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Introduction to TREND IQ 3XCITE Controller Honeywell


IQ 3XCITE FEATURES
Additional Features

Enhance Alarm handling capabilities


Points in alarms will be highlighted in web pages Retransmit alarm to Supervisor software via IP address Retransmit alarm via SMTP to email server address

Additional LED Indicator


Power Indicator (Status & Fault) Watchdog Indicator (Software & RAM fault) Input / Output Bus Indicator (I/O Module Bus fault) Input / Output Terminal Indicator Network Transmission Indicator

18

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

HARDWARE

19

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Hardware Physical Layout

Honeywell

Optional Battery Card If an IQ 3Xcite Controller is set up to be a time master, an optional battery card is recommended to be installed. The battery shall help to maintain the Real Time Clock (RTC) for several years. However it need to be replaced every 5 years.
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S

20

File Number

TREND IQ 3xx Controllers


Battery Back-up (Optional)
Battery Card Real Time Clock
Battery Card The optional battery card is used only to maintained the Real Time Clock. As memory is stored in Flash, hence no battery required.

Honeywell

IQ 3Xcite Battery Card

21

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Controller Power Supply

Honeywell

Power Supply : 100 ~ 230 Vac

Power Supply : 24 ~ 36 Vdc

22

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Controller Interface

Honeywell

23

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Controller Data Storage

Honeywell

24

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Hardware Physical Layout
Expandable Module
Module Address Switch

Honeywell

BUS I/O Connection

Power Supply

25

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Hardware Physical Layout
Expandable Module Range
8 Channel Module

Honeywell

26

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Hardware Physical Layout
Expandable Module Range
4 Channel Module

Honeywell

27

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Hardware Physical Layout
Expandable Module Range
16 Channel Module
I/O Modules

Honeywell

28

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Series Controller


Expandable Module
Rigid Connector

Honeywell

End-ofEnd-of-Line Terminator

Adjacent Rigid Inter-connector Inter-

29

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Series Controller


Expandable Module
Cable Connector

Honeywell

Wire Connector (terminator)

30

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Auxiliary Power Supply 24Vdc

Honeywell

31

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Power Supply (I/O Modules)

Honeywell

32

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND IQ 3xx Controllers


Power Supply (I/O Modules)

Honeywell

24 Vdc Power Supply (max 1.3 A) 24 Vdc Power Supply (max 2.5 A) 24 Vdc Power Supply (max 5 A)

33

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

ETHERNET NETWORKS

34

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet Networks
TREND Ethernet Networks
IQ 3 series controller

Honeywell
SUPERVISOR

Uses Ethernet and TCP/IP networking technologies, IT network enable, accessible from anywhere.

IQ 3XCITE TREND ETHERNET

WAN

35

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet Networks
Physical Medium
Network Cable

Honeywell

10 Base T Use a Physical STAR Topology, but uses a Logical BUS Topology for communication Device attach to HUB using a CAT3 or higher twisted pair cable HUBs & devices have LINK LED which indicates the segment is healthy Expand the network by daisy chaining HUB, Other similar networks in this style 100 Base T CAT5 (100Mbytes/s) 1000 Base T CAT6 (1Gbytes/s)

36

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet Networks
Physical Medium
Network Cable
Types of cable (Ethernet)

Honeywell

37

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Ethernet Networks
Physical Medium
TREND Ethernet Devices (Industrial Rate)

Honeywell

Industrial rate network equipment is designed to operate in harsh industrial environmental. DIN rail mounting and suitable for use in controller enclosure

TREND EDA-205 5 port switch

TREND EDS-305 5 port switch 4 x 10/100 Base T & 1 x 100 Base T

TREND IMC-101 Media Convertor 10/100 Base T to 100 Base Fx

EDAEDA-205 5 port Ethernet Switch EDSEDS-305 5 port Ethernet Switch


38

IMCIMC-101 Media Convertor

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Web Pages Configuration
Introduction

Honeywell

IQ 3 controllers incorporate a web server which can deliver user-specific pages to a usercomputer running standard internet browser software.

IQ 3XCITE

39

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Web Pages Configuration
Welcome Page

Honeywell

IQ 3 controllers incorporate a web server which can deliver user-specific pages to a usercomputer running standard internet browser software.

40

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Web Pages Configuration
Module Page

Honeywell

Module page options allows the user to see the controller strategy. Values can be changed with the keyboard and sent with eitherEnter or one of the adjustment icons.

41

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Web Pages Configuration
Plant GraphIQs

Honeywell

Using Display & Directory Modules we can create Plant Graphics

42

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Web Pages Configuration
Create GraphIQs

Honeywell

43

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Security Configuration
Default System Guest

Honeywell

IQ 3 controllers incorporate a security features to prevent unathuorised access to the parameter of the controller. However, as default, no user is set up at the controller. Although no user is set up, one user still exist; System Guest with L100 (level 100) access). If you do not Log into the IQ 3 controller, you are log in as a System Guest which allow you full access for an unprotected controller

44

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Security Configuration
Default System Guest

Honeywell

As soon as you configure a user, the System Guess access level is changed to L-1 L(level -1). Hence basic read only access is given However, user 1 should always be configured at level 99 first and removed last.

System Guest with read-only access read-

45

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Configuration
Security Configuration
Level of Access

Honeywell

Once Users are configured, the module view window will only show appropriate modules depending on level access

46

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

PORTABLE DISPLAY PANEL

47

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
Display Panel
Introduction

Honeywell

TREND have provided portable display panel for the new IQ 3 network system

TREND IQ VIEW Display

TREND Smart Display Unit (SDU)

48

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
TREND Network Display Panel IQ VIEW Portable Display A touch screen network display panel for interface to the TREND System Features

Honeywell

TREND IQ VIEW Display

Provide a user interface to the TREND IQ system Self-configuration Display graphs View & adjustment of system values View alarms Trend Loop or Ethernet Connection Password user protection

49

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
Display Panel
IQ View Overview

Honeywell

50

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
Display Panel
IQ View Physical

Honeywell

51

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
Display Panel
IQ View Connection

Honeywell

Via the Built-in Vcnc Built-

52

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
Display Panel
IQ View Connection

Honeywell

Via third-Party Vcnc third-

53

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Portable Display
TREND Portable Display Panel Smart Display Unit (SDU) A small display panel for interface to the TREND System Features

Honeywell

Electroluminescent 4 x 20 character display Illuminated button for selection or adjustment Allows viewing and adjustment of plant parameters. Display the alarm log Access IQ via supervisor port only.

TREND Smart Display Unit (SDU)

Variant of smart display unit

IQ Current loop controllers IQ Xcite Ethernet controller IQL LON Controllers.


N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
File Number

54

Honeywell

SUPERVISOR SOFTWARE

55

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Supervisor Software
INTRODUCTION
SUPERVISOR SOFTWARE : WHAT IS IT ?

Honeywell

A real time, user interface independent of the TREND System to allow monitoring and parameter adjustment to the system controllers. Main Features :

Device Viewer Graph Display Password Access Scheduling Capabilities Alarm Management

TREND 963 Supervisor Software

Types of TREND Supervisor Software:


TREND 916 MDS Software

Workstation Supervisor - 963 Supervisor Software Pocket PC Supervisor - 916 Mobile Display Software (MDS)
N O V A R I N T E L L I G E N T B U I L D I N G S Y S T E M S
File Number

56

Supervisor Software
TREND 963 Supervisor Software
A graphical real-time interface software for monitor / control for the graphical, TREND building system Workstation Supervisor

Honeywell

Features :

Time Schedules

Record Trend Logs

Set-point Adjustment

Schematics Page

Alarm Database

Password Protection

Email Retransmission

Client -Server

57

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND Workstation Supervisor


Available in different version: 963 Lite Most basic package which provide all the fundamental features required of a supervisory package

Honeywell

963 Server Similar facilities with 963 Lite in addition of enabling the 963 to act as a web server allowing access through a web browser software such as Internet Explorer 963 Secure Similar facilities with 963 Lite plus an additional security features to comply to FDA Regulation 21 CPR Part 11 for pharmaceutical application 963 SNMP Similar facilities with 963 Lite plus the capabilities of retransmitting alarm in Simple Network Management Protocol (SNMP) format 963 SMS Direct Similar facilities with 963 Lite plus the capabilities of retransmitting alarm in Short Message Services (SMS) text messaging. GSM modem included
58

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Supervisor Software
TREND 916MDS Software
A portable real-time interface software for monitor / control for the portable, TREND building system Pocket PC Supervisor

Honeywell

Navigator

Monitoring Data

Trend Logs

Alarm Logs

Features Small hand held device true portability Instant operation, fast connection, Any Where Simple interface, easy to train, easy to use Ethernet (wireless), GSM, Bluetooth, Serial connection Trend parameters can be viewed and adjusted
59

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

INTERFACE

60

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Interface Device
TREND Relay Module
Single Relay Module (SRMV) :

Honeywell

Enables a controller analogue voltage output signal to drive a single changeover relay (Digital Output) Maximum resistive load 8 Amps
TREND Single Relay Module Voltage

2 Single Relay Module AC (2 SRM) :

Enables two controller analogue voltage output signal to drive two single changeover relay independently (Digital Output) Maximum resistive load 5 Amps with manual override link
TREND Single Relay Module AC

61

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Interface Device
TREND Signal Converter Module
Two Voltage (V) to two Current (I) Converter Driver Module (2VID)

Honeywell

Converts two channel controller analogue voltage output signal (0 to 10Vdc) to two current output signal (0 mA to 20 mA) Manual override links for aid of commissioning.
TREND 2VID Module

Voltage (V) to Pneumatic Converter Driver Module (PN/VPC)

Converts a controller analogue voltage output signal (0 to 10Vdc) to a proportional pneumatic signal (0.2 bar to 1bar) Requires an external 24 Vac power supply.

TREND PN/VPC Converter Module

62

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

FIELD DEVICES

63

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Field Devices
TREND provides a wide range of field devices to suit the need of many different applications. Range of Field Devices

Honeywell

Field Sensors

Temperature, Humidity, Pressure, Air Quality, Carbon Dioxide, Velocity Differential Pressure Current Transformer, Multi-parameter meter Occupancy Valve, Damper Threaded, Flanged

Field Switches

Electricity Meters

Detectors

Electronic Actuators

Valves

Variable Speed Drive

64

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Field Devices
TREND Wireless Temperature Sensors

Honeywell

Plant Temperature sensor Receiver


coverage of up to 32 sensors with a single receiver covering up to 17,000m2


TREND Wireless Sensor

No cable, no screwdriver, no hassle Simple set-up software Battery life in excess of 5 years

TREND TW/S Sensor

TREND TW/P Sensor

TREND IQ 3Xcite Controller TREND XW/R/IQ Transmitter


65

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Field Devices
TREND LCD Temperature Sensors

Honeywell

Space temperature sensor c/w 3 digit display


Indication & Adjustment of Set-point Indication of fan speed and occupancy

Connect to the controller via supervisor port (T-Bus) Can display reading in either Celsius or Fahrenheit Available in two variants

IQ version : IQ 2xx & IQ 3xx controllers IQL version : IQL controllers

TREND Room Display Unit

66

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Summary
TREND Network Summary
ETHERNET PNC

Honeywell

ENC2

EM/MPO

TMNG

IQ VIEW

GSM

IQ 242

TMNG

LAN LAN CNC2

IQ VIEW

LINC

IQ 3XACT SUPERVISOR

MOBILE SOFTWARE

67

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

TREND System
Typical Building Application
Applications

Honeywell

68

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Honeywell

THE END

Thank you for your attention

69

N O V A R

I N T E L L I G E N T

B U I L D I N G

S Y S T E M S

File Number

Вам также может понравиться