Вы находитесь на странице: 1из 32

Technical Specification: STC/HFXJG-01-2005 2000A

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Reference Design ST 104/1/620 of Pirelli Design Authority

02

SHIPBOARD CABLES

CABLES ACCORDING TO IEC 60092-350 Series


SECTION A: POWER AND CONTROL CABLES FOR FIXED INSTALLATION IN SHIP
HFX-U
HFX-A/Cu
HFX-U-FR
HFX-A/Cu-FR

Unarmoured fire retardant


Armoured fire retardant
Unarmoured fire retardant, fire resisting
Armoured fire retardant, fire resisting

pag.
pag.
pag.
pag.

06
08
10
12

Power and control cables, general informations


Legend
Cores identification for power and control cables
Dimensional and electrical data of conductors
Fire retardant and fire resisting cables
Current ratings of continuos service
Correction factors at ambient temperatures
Reactance

pag.

14

SECTION B: INSTRUMENTATION CABLES FOR FIXED INSTALLATIONS IN SHIPS


HFX-OSU
HFX-ISU
HFX-OSA/Cu
HFX-ISA/Cu
HFX-ISOSA/Cu
HFX-OSA/Cu-FR

Collectively screened, unarmoured


Individually screened and overall screened, unarmoured
Collectively screened, armoured
Individually screened and overall screened, armoured
Individually screened and overall screened, armoured
Collectively screened, armoured

pag.
pag.
pag.
pag.
pag.
pag.

18
20
22
24
24
26

Instrumentation cables, general informations


Legend
Colour scheme in instrumentation cables
Dimensional and electrical data of conductors
Conductor size
Maximum shipping length and drum type
Drums: dimensions and weight

pag.

28

TPPC

Reference Design ST 104/1/620


of Pirelli Design Authority

Shipboard, catalogue
03

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD CABLES

SHIPBOARD

Symbols

04

Fire behaviour
According to: IEC 60332-1 flame retardant
IEC 60332-3 cat A fire retardant
IEC 60331 fire resistant
IEC 60332-3A/60331 fire retardant and fire resistant

Chemicals resistance
Outer sheath resistance to chemicals

Impacts
Cable mechanical resistance to impacts

low
Smoke density, corrosivity and toxicity
Low emission of smoke, acid and toxic gases:
IEC 61034 (smoke)
IEC 60754 (acid and toxic gases)

Temperature
Permissible minimum and maximum ambient
temperature

Severe weather conditions


Resistance to sun and rain

Bending radii
Minimum bending radius for installed cables

TPPC

SECTION

Power and control cables


for fixed installation in ship

Shipboard, catalogue
05

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Unarmoured power and control cables


Fire retardant according to

IEC 60332-3A

Cable designation

HFX-U 0.6/1 kV

Construction
Conductors:

plain (or request tinned) annealed copper wires, according to class 2 (class
5 only on request) of IEC 60228.
(See sheet 13 for dimensional and electrical characteristics)

Insulation:

HF-XLPE

Filler (if any):

halogen free compound for cables 35 mm2

Sheath:

SHF1
thickness according to IEC 60092-353 3.7.3 a.

Marking:

e. g. : TPPC HFX-U 0.6/1 kV nc x sect. - IEC 60332-3A

Standards applicable
IEC 60092-350
IEC 60092-353
IEC 60092-351
IEC 60092-359

Design guideline
Design guidelines
Insulating materials
Sheathing materials

IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

low
r

IEC 60332-1
IEC 60332 - 3A

MODERATE

LOW EMISSION

MODERATE

-15 C
+75 C

MODERATE

D 25 mm: r = 4D
D > 25 mm: r = 6D

Table 1: HFX-U 0.6 kV, unarmoured cables

N.
of core

06

Sect.

Conductor
diameter

Insulation
thickness

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm )

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

1
1
1
1
1
1
1
1
1
1
1
1
1

4
6
10
16
25
35
50
70
95
120
150
185
240

2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1
18,6

0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7

1,0
1,0
1,0
1,0
1,1
1,1
1,2
1,3
1,3
1,4
1,5
1,5
1,6

6,2
6,8
7,6
8,6
10,6
12,2
13,6
15,5
17,5
19,0
21,5
23,5
26,0

7,2
7,8
8,6
9,6
11,6
13,2
14,6
16,5
18,5
20,0
23,0
25,0
27,5

65
85
130
185
290
410
530
750
1000
1260
1540
1900
2480

29
31
34
38
46
53
58
66
74
80
92
100
165

4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754

4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762

TPPC
Unarmoured power and control cables
Fire retardant according to

IEC 60332-3A

Table
1: -0.6/1kV,
cables
Table
1 cont. : unarmoured
HFX-U 0.6 kV,
unarmoured cables
N.
of core

Sect.

Conductor
diameter

Insulation
thickness

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

2
2
2
2
2
2
2

1,5
2,5
4
6
10
16
25

1,6
2,1
2,6
3,2
4,1
5,1
6,4

0,7
0,7
0,7
0,7
0,7
0,7
0,9

1,0
1,1
1,1
1,1
1,2
1,3
1,4

8,2
9,2
10,2
11,4
13,4
15,5
19,0

9,2
10,2
11,2
12,4
14,4
16,5
20,0

70
95
130
175
265
395
600

37
41
45
50
58
66
80

12,1
7,41
4,61
3,08
1,83
1,15
0,727

12,2
7,56
4,70
3,11
1,84
1,16
0,734

3
3
3
3
3
3
3
3
3
3
3
3
3
3

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

1,0
1,1
1,1
1,2
1,2
1,3
1,4
1,5
1,7
1,8
1,9
2,1
2,5
2,7

8,6
9,8
10,8
12,4
14,2
16,5
20,5
23,0
26,0
30,0
34,5
38,5
47,5
52,0

9,6
10,8
11,8
13,4
15,2
17,5
22,0
24,5
27,5
32,0
36,5
40,5
50,0
55,0

98
130
180
250
375
600
930
1380
1780
2510
3420
4300
6150
7550

38
43
47
54
61
70
88
98
165
192
219
243
300
330

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
4
4
4
4
4
4
4
4
4
4
4
4
4

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

1,1
1,1
1,2
1,2
1,3
1,4
1,5
1,6
1,8
1,9
2,1
2,2
2,7
2,9

9,6
10,6
12,0
13,6
15,7
18,5
23,0
25,5
29,0
33,5
38,5
42,5
52,5
57,5

10,6
11,6
13,0
14,6
16,7
19,5
24,5
27,0
30,5
35,5
40,5
44,5
55,5
60,5

120
165
235
325
500
785
1215
1720
2275
3210
4400
5520
7750
9500

42
46
52
58
67
78
98
162
183
213
243
267
333
363

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
5
7
10
12
14
16
19
24
27
30
37

1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0

1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,0
1,1
1,1
1,2
1,2
1,2
1,3
1,3
1,4
1,4
1,4
1,5

8,8
9,8
10,6
13,6
14,0
14,8
15,5
16,5
19,5
20,0
20,5
22,5

9,8
10,8
11,6
14,6
15,0
15,8
16,5
17,5
20,5
21,5
22,0
24,0

95
115
150
205
240
270
310
355
450
495
540
660

39
43
46
58
60
63
66
70
82
86
88
96

18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1

18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2

5
7
10
12
14
16
19
24
27
30
37

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,1
1,1
1,2
1,3
1,3
1,3
1,4
1,5
1,5
1,5
1,6

10,4
11,4
14,6
15,0
16,0
16,5
18,0
21,0
21,5
22,0
24,0

11,4
12,4
15,6
16,0
17,0
17,5
19,0
22,5
23,0
23,5
25,5

150
190
270
320
360
410
480
605
665
730
890

46
50
62
64
68
70
76
90
92
94
153

12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1

12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2

Shipboard, catalogue
07

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Armoured power and control cables


Fire retardant according to

IEC 60332-3A

Cable designation

HFX-A/Cu 0.6/1 kV

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 only on request) of IEC 60228.
(See sheet 13 for dimensional and electrical characteristics)

Insulation:

HF-XLPE

Filler (if any):

halogen free compound

Inner covering:

synthetic tape(s) or halogen free compound (for cables 35 mm2) thickness


according to IEC 60092-353 3.5.2

Braid:

made of plain copper wire (on request, tinned copper)


IEC 60092-353 3.8

Sheath:

SHF1
thickness according to IEC 60092-353 3.7.3 a.

Marking:

e. g. : TPPC HFX-A/Cu 0.6/1 kV nc x sect. - IEC 60332-3A

Standards applicable
IEC 60092-350
IEC 60092-353*
IEC 60092-351
IEC 60092-359

Design guideline
Design guidelines
Insulating materials
Sheathing materials

IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

* dont foreseen cables with rated voltage 0.6/1 kV with cross sect. less than 1.5 mm2
low
r

IEC 60332-1
IEC 60332 - 3A

MODERATE

GOOD

LOW EMISSION

-15 C
+75 C

MODERATE

r = 6D

Table 2: HFX-A/Cu 0.6/1 kV, armoured cables

N.
of core

08

Sect.

Conductor
diameter

Insulation
thickness

Armour
wires
diameter

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm )

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

1
1
1
1
1
1
1
1
1
1
1
1
1

4
6
10
16
25
35
50
70
95
120
150
185
240

2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1
18,6

0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7

0,2
0,2
0,2
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,0
1,0
1,1
1,1
1,2
1,2
1,3
1,4
1,5
1,5
1,6
1,7
1,8

7,4
8,0
9,2
10,2
12,0
12,8
16,0
18,0
20,0
21,5
24,0
26,0
29,0

8,4
9,0
10,2
11,2
13,0
13,8
17,0
19,0
21,5
23,0
25,5
27,5
30,5

95
120
170
235
350
440
660
890
1180
1440
1760
2140
2760

50
54
61
67
78
83
102
114
129
138
153
165
183

4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754

4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762

TPPC
Armoured power and control cables
Fire retardant according to

IEC 60332-3A

Table
1: -0.6/1kV,
cables
Table
2 cont. : unarmoured
HFX-A/Cu 0.6/1
kV, armoured cables
N.
of core

Sect.

Conductor
diameter

Insulation
thickness

Armour
wires
diameter

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

2
2
2
2
2
2
2

1,5
2,5
4
6
10
16
25

1,6
2,1
2,6
3,2
4,1
5,1
6,4

0,7
0,7
0,7
0,7
0,7
0,7
0,9

0,2
0,2
0,2
0,2
0,3
0,3
0,3

1,1
1,1
1,2
1,2
1,3
1,4
1,5

9,6
10,6
11,8
13,0
15,5
18,0
21,5

10,6
11,6
12,8
14,0
16,5
19,0
23,0

120
150
195
275
425
590
860

64
70
77
84
99
114
138

12,1
7,41
4,61
3,08
1,83
1,15
0,727

12,2
7,56
4,70
3,11
1,84
1,16
0,734

3
3
3
3
3
3
3
3
3
3
3
3
3
3

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

0,2
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,4
0,4
18,1
20,1

1,1
1,1
1,2
1,2
1,3
1,4
1,5
1,7
1,8
2,0
2,1
2,3
2,5
2,7

10,2
11,0
12,4
13,6
16,5
19,0
22,5
26,5
29,0
34,0
38,5
42,0
47,5
52,0

11,2
12,0
13,4
14,6
17,5
20,0
24,0
28,0
30,5
36,0
40,5
44,0
50,0
55,0

145
185
243
340
520
750
1120
1660
2100
2950
4010
4990
6150
7550

67
72
80
88
105
120
144
168
183
216
243
264
300
330

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
4
4
4
4
4
4
4
4
4
4
4
4
4

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,4
0,4
0,4
18,1
20,1

1,1
1,2
1,2
1,3
1,4
1,5
1,6
1,8
1,9
2,1
2,3
2,4
2,7
2,9

10,8
12,2
13,4
15,5
18,0
20,5
25,0
29,0
32,0
37,5
42,5
46,5
52,5
57,5

11,8
13,2
14,4
16,5
19,0
22,0
26,5
30,5
34,0
39,5
44,5
49,0
55,5
60,5

180
225
305
410
635
905
1360
2070
2640
3700
5070
6300
7750
9500

71
79
86
99
114
132
159
183
204
237
267
294
333
363

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
5
7
10
12
14
16
19
24
27
30
37

1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0

1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,1
1,1
1,2
1,3
1,3
1,3
1,4
1,4
1,5
1,5
1,5
1,6

10,4
11,0
12,2
15,5
16,0
17,0
18,0
18,5
21,5
22,0
22,5
24,5

11,4
12,0
13,2
16,5
17,0
18,0
19,0
19,5
23,0
23,5
24,0
26,0

140
160
200
310
345
385
430
485
600
650
700
840

68
72
79
99
102
108
114
117
138
141
144
156

18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1

18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2

5
7
10
12
14
16
19
24
27
30
37

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,2
1,2
1,3
1,4
1,4
1,4
1,5
1,6
1,6
1,6
1,7

12,0
12,8
16,5
17,5
18,0
19,0
20,0
23,5
24,0
24,5
26,5

13,0
13,8
17,5
18,5
19,0
20,0
21,5
25,0
25,5
26,0
28,0

200
245
380
435
480
530
610
760
830
900
1060

78
83
105
111
114
120
129
150
153
156
168

12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1

12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2

Shipboard, catalogue
09

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Unarmoured power and control cables


Fire retardant according to
Fire resisting according to

IEC 60332-3A
IEC 60331

Cable designation

HFX-U-FR 0.6/1 kV

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 on request) of IEC 60228.
(See sheet 13 for dimensional and electrical characteristics)

Insulation:

mica tape(s) + HF-XLPE

Filler (if any):

halogen free compound (for cables 35 mm2)

Sheath:

SHF1
thickness according to IEC 60092-353 3.7.3 a.

Marking:

e. g. : TPPC HFX-U-FR 0.6/1 kV nc x sect. - IEC 60331


IEC 60332-3A

Standards applicable
IEC 60092-350
IEC 60092-353*
IEC 60092-351
IEC 60092-359

Design guideline
Design guidelines
Insulating materials
Sheathing materials

IEC 60331
Fire resistance
IEC 60332-1
Flame retardance
IEC 60332-3A
Fire retardance on bunched cables
IEC 60754-1, ..-2 Halogen free properties
IEC 61034-1, ..-2 Low smoke emission
* dont foreseen cables with rated voltage 0.6/1 kV with cross sect. less than 1.5 mm2
low
r

IEC 60332 - 3A
IEC 60331

MODERATE

LOW EMISSION

MODERATE

-15 C
+75 C

MODERATE

D 25 mm: r = 4D
D > 25 mm: r = 6D

Table 3: HFX-U-FR 0.6/1 kV, unarmoured fire resisting cables

N.
of core

10

Sect.

Conductor
diameter

Insulation
thickness

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm )

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

1
1
1
1
1
1
1
1
1
1
1
1
1

4
6
10
16
25
35
50
70
95
120
150
185
240

2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1
18,6

0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7

1,1
1,1
1,1
1,2
1,2
1,3
1,3
1,4
1,5
1,5
1,6
1,7
1,8

6,8
7,4
8,4
9,4
11,4
13,0
14,4
16,5
18,5
20,5
22,5
24,5
27,5

7,8
8,4
9,4
10,4
12,4
14,0
15,4
17,5
19,5
22,0
24,0
26,0
29,0

70
95
145
205
310
405
560
780
1040
1300
1600
1960
2540

31
34
38
42
50
56
62
70
78
88
96
156
174

4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754

4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762

TPPC
Unarmoured power and control cables
Fire retardant according to
Fire resisting according to

IEC 60332-3A
IEC 60331

Table
1: -0.6/1kV,
cables
Table
3 cont. : unarmoured
HFX-U-FR 0.6/1
kV, unarmoured fire resisting cables
N.
of core

Sect.

Conductor
diameter

Insulation
thickness

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

2
2
2
2
2
2
2

1,5
2,5
4
6
10
16
25

1,6
2,1
2,6
3,2
4,1
5,1
6,4

0,7
0,7
0,7
0,7
0,7
0,7
0,9

1,0
1,1
1,1
1,1
1,2
1,3
1,4

9,2
10,4
11,4
12,6
14,6
17,0
20,5

10,2
11,4
12,4
13,6
15,6
18,0
22,0

85
110
145
195
280
410
625

41
46
50
54
62
72
88

12,1
7,41
4,61
3,08
1,83
1,15
0,727

12,2
7,56
4,70
3,11
1,84
1,16
0,734

3
3
3
3
3
3
3
3
3
3
3
3
3
3

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

1,0
1,1
1,1
1,2
1,2
1,3
1,4
1,5
1,7
1,8
1,9
2,1
2,5
2,7

9,8
11,0
12,0
13,6
16,0
18,5
22,5
25,0
28,0
32,0
36,5
40,5
47,5
52,0

10,8
12,0
13,0
14,6
17,0
19,5
24,0
26,5
29,5
34,0
38,5
42,5
50,0
55,0

110
145
195
270
390
600
940
1375
1810
2530
3450
4350
6150
7550

43
48
52
58
68
78
96
106
177
204
231
255
300
330

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
4
4
4
4
4
4
4
4
4
4
4
4
4

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

1,1
1,1
1,2
1,2
1,3
1,4
1,5
1,6
1,8
1,9
2,1
2,2
2,7
2,9

10,8
12,0
13,4
14,8
18,0
20,5
25,0
27,5
31,0
35,5
40,5
45,0
52,5
57,5

11,8
13,0
14,4
15,8
19,0
22,0
26,5
29,0
33,0
37,5
42,5
47,5
55,5
60,5

140
185
255
345
530
790
1200
1840
2420
3360
4600
5740
7750
9500

47
52
58
63
76
88
106
174
198
225
255
285
333
363

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
5
7
10
12
14
16
19
24
27
30
37

1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0

1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,0
1,1
1,1
1,2
1,2
1,2
1,3
1,3
1,4
1,4
1,4
1,5

10,0
11,2
12,2
16,0
16,5
17,0
18,5
19,5
22,5
23,0
24,0
26,0

11,0
12,2
13,2
17,0
17,5
18,0
19,5
20,5
24,0
24,5
25,5
27,5

110
135
175
250
285
325
375
430
540
600
650
800

44
49
53
68
70
72
78
82
96
98
102
110

18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1

18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2

5
7
10
12
14
16
19
24
27
30
37

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,1
1,1
1,2
1,3
1,3
1,3
1,4
1,5
1,5
1,5
1,6

12,0
13,0
17,0
17,5
18,5
19,5
20,5
24,5
25,0
26,0
28,0

13,0
14,0
18,0
18,5
19,5
20,5
22,0
26,0
26,5
27,5
29,5

170
220
310
365
420
470
550
700
770
840
1020

52
56
72
74
78
82
88
104
106
110
177

12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1

12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2

Shipboard, catalogue
11

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD CABLES

SHIPBOARD

Armoured power and control cables


Fire retardant according to
Fire resistant according to

IEC 60332-3A
IEC 60331

Cable designation

HFX-A/Cu-FR 0.6/1 kV

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 only on request) of to IEC 60228.
(See sheet 13 for dimensional and electrical characteristics)

Insulation:

mica tape(s) + HF-XLPE

Inner covering:

halohen free compound


thickness according to IEC 60092-353 3.5.2

Braid:

made of plain copper wire (on request, tinned copper)


IEC 60092-353 3.8

Sheath:

SHF1
thickness according to IEC 60092-353 3.7.3 a.

Marking:

e. g. : TPPC HFX-A/Cu-FR 0.6/1 kV nc x sect. - IEC 60331


IEC 60332-3A

Standards applicable
IEC 60092-350
IEC 60092-353*
IEC 60092-351
IEC 60092-359

Design guideline
Design guidelines
Insulating materials
Sheathing materials

IEC 60331
Fire resistance
IEC 60332-1
Flame retardance
IEC 60332-3A
Fire retardance on bunched cables
IEC 60754-1, ..-2 Halogen free properties
IEC 61034-1, ..-2 Low smoke emission
* dont foreseen cables with rated voltage 0.6/1 kV with cross sect. less than 1.5 mm2
low
r

IEC 60332 - 3A
IEC 60331

MODERATE

GOOD

LOW EMISSION

-15 C
+75 C

MODERATE

r = 6D

Table 4: HFX-A/Cu-FR 0.6/1 kV, fire resistant armoured cables

N.
of core

12

Sect.

Conductor
diameter

Insulation
thickness

Armour
wires
diameter

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm )

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

1
1
1
1
1
1
1
1
1
1
1
1
1

4
6
10
16
25
35
50
70
95
120
150
185
240

2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1
18,6

0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,4
1,6
1,7

0,2
0,2
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,1
1,1
1,1
1,2
1,2
1,3
1,3
1,4
1,5
1,5
1,6
1,7
1,8

9,4
10,0
11,0
12,2
14,0
15,5
16,5
18,5
20,5
22,5
24,5
26,5
29,5

10,4
11,0
12,0
13,2
15,0
16,5
17,5
19,5
22,0
24,0
26,0
28,0
31,0

145
170
230
305
425
560
690
930
1220
1480
1800
2200
2800

62
66
72
79
90
99
105
117
132
144
156
168
186

4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754

4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762

TPPC
Armoured power and control cables
Fire retardant according to
Fire resisting according to

IEC 60332-3A
IEC 60331

Table
1: -0.6/1kV,
cables
Table
4 cont. : unarmoured
HFX-A/Cu-FR
0.6/1 kV, fire resistant armoured cables
N.
of core

Sect.

Conductor
diameter

Insulation
thickness

Armour
wires
diameter

Outer
sheath
thickness

Outer
diameter
approx

Outer
diameter
maximum

Net
weight
approx

Bending
radius
minimum

plain max.

tinned max.

D. C. resistant at 20 C

(n)

(mm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(/km)

(/km)

2
2
2
2
2
2
2

1,5
2,5
4
6
10
16
25

1,6
2,1
2,6
3,2
4,1
5,1
6,4

0,7
0,7
0,7
0,7
0,7
0,7
0,9

0,2
0,2
0,2
0,3
0,3
0,3
0,3

1,1
1,2
1,2
1,3
1,3
1,4
1,5

11,8
13,0
14,0
16,0
17,5
20,0
23,5

12,8
14,0
15,0
17,0
18,5
21,5
25,0

210
250
310
425
560
760
1080

77
84
90
102
111
129
150

12,1
7,41
4,61
3,08
1,83
1,15
0,727

12,2
7,56
4,70
3,11
1,84
1,16
0,734

3
3
3
3
3
3
3
3
3
3
3
3
3
3

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

0,2
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,4
0,4
18,1
20,1

1,2
1,2
1,2
1,3
1,4
1,4
1,6
1,7
1,8
2,0
2,1
2,3
2,5
2,7

12,6
13,6
14,6
16,5
19,0
21,5
25,5
28,0
30,5
35,5
40,0
44,0
47,5
52,0

13,6
14,6
15,6
17,5
20,0
23,0
27,0
29,5
32,5
37,5
42,0
46,0
50,0
55,0

240
290
355
490
690
930
1360
1740
2220
3060
4140
5100
6150
7550

82
88
94
105
120
138
162
177
195
225
252
276
300
330

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
4
4
4
4
4
4
4
4
4
4
4
4
4

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

1,6
2,1
2,6
3,2
4,1
5,1
6,4
7,1
8,1
9,7
11,6
13,0
14,5
16,1

0,7
0,7
0,7
0,7
0,7
0,7
0,9
0,9
1,0
1,1
1,1
1,2
1,8
2,0

0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,4
0,4
0,4
18,1
20,1

1,2
1,2
1,3
1,3
1,4
1,5
1,7
1,8
1,9
2,1
2,3
2,4
2,7
2,9

13,4
14,6
16,5
18,0
21,0
23,5
28,0
30,5
33,5
39,0
44,0
48,5
52,5
57,5

14,4
15,6
17,5
19,0
22,5
25,0
29,5
32,5
35,5
41,0
46,0
51,0
55,5
60,5

210
260
370
475
690
960
1420
1800
2740
3900
5180
6420
7750
9500

86
94
105
114
135
150
177
195
213
246
276
306
333
363

12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,126
0,100

12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100

4
5
7
10
12
14
16
19
24
27
30
37

1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0

1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4
1,4

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,2
1,2
1,2
1,3
1,4
1,4
1,4
1,4
1,5
1,6
1,6
1,6

12,8
13,8
14,8
19,0
19,5
20,5
21,5
22,5
25,5
26,5
27,0
29,0

13,8
14,8
15,8
20,0
20,5
22,0
23,0
24,0
27,0
28,0
28,5
30,5

230
260
310
455
510
550
610
680
830
910
970
1120

83
89
95
120
123
132
138
144
162
168
171
183

18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1
18,1

18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2
18,2

5
7
10
12
14
16
19
24
27
30
37

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,2
1,3
1,4
1,4
1,4
1,5
1,5
1,6
1,6
1,7
1,7

14,6
16,5
20,0
20,5
21,5
22,5
23,5
27,5
28,0
29,0
31,0

15,6
17,5
21,5
22,0
23,0
24,0
25,0
29,0
29,5
30,5
33,0

300
370
540
590
650
730
820
1000
1080
1180
1380

94
105
129
132
138
144
150
174
177
183
198

12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1
12,1

12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2
12,2

Shipboard, catalogue
13

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Power and control cables


General informations

14

Legend
Code
HFX*

halogen free cable XLPE insulation (stranded conductors cl. 2)

IS

pairs, triples individually shielded with aluminium/polyester

unarmoured

OS aluminium/polyester overall shielded

armoured (galvanized steel wire braid)

FR fire resistant (IEC 60331 750 C) cable

A/Cu

armoured (copper wire braid-plain or tinned)

* FHFX - for cables with flexible conductors cl.5.

Cores identification for power and control cables


Without earth conductor
LOW VOLTAGE POWER CABLES

LOW VOLTAGE CONTROL CABLES

With earth conductor

2 cores

Black - Blue

3 cores

Black - Blue - Brown

Green/yellow - Black - Blue

4 cores

Black - Blue - Brown - Black

Green/yellow - Black - Blue - Brown

4 or more cores

Black insulation with white printed numbers

1 Green/yellow - the others numbered

Dimensional and electrical data of conductors (0.6/1 kV)


In accordance with IEC 228 class 2, tinned stranded copper conductors, compacted for cross sectional area 35 mm2
FIRE RETARDANT (IEC 332-3A) CABLES

FIRE RETARDANT (IEC 332-3A) AND FIRE RESISTING CABLES (IEC 331)

D. C. resist. at 85 C

Nominal

Conductors

Core

c.s.a.

diameter approx

diameter approx
plain

tinned

(mm2)

(mm)

(mm)

(/km)

1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

1.3
1.6
2.0
2.6
3.2
4.1
5.1
6.4
7.1
8.1
9.7
11.6
13.0
14.5
16.1
18.6
20.7
23.2

2.7
3.0
3.4
4.0
4.6
5.5
6.5
8.2
8.9
10.1
11.9
13.8
15.4
17.3
19.3
22.0
24.3
27.0

22.7
15.2
9.30
5.79
3.87
2.30
1.44
0.913
0.658
0.486
0.336
0.244
0.194
0.158
0.124
0.0983
0.0800
0.0648

D. C. resist. at 85 C

Nominal

Conductors

Core

c.s.a.

diameter approx

diameter approx
plain

tinned

(/km)

(mm2)

(mm)

(mm)

(/km)

(/km)

22.8
15.3
9.49
5.90
3.90
2.31
1.46
0.922
0.665
0.492
0.340
0.246
0.195
0.160
0.128
0.0993
0.0807
0.0654

1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

1.3
1.6
2.0
2.6
3.2
4.1
5.1
6.4
7.1
8.1
9.7
11.6
13.0
14.5
16.1
18.3
20.7
23.2

3.2
3.4
3.8
4.4
5.0
6.0
7.0
8.7
9.4
10.6
12.4
14.3
15.9
17.8
19.8
22.5
24.8
27.5

22.7
15.2
9.30
5.79
3.87
2.30
1.46
0.913
0.658
0.486
0.336
0.244
0.194
0.158
0.124
0.0983
0.0800
0.0648

22.8
15.3
9.49
5.90
3.90
2.31
1.46
0.922
0.665
0.492
0.340
0.246
0.195
0.160
0.128
0.0993
0.0807
0.0654

TPPC
Power and control cables
General informations
Current ratings
For the cables of this catalogue, the current ratings are based on conductors temperature of 85 C, an ambient temperature of 45 C and four cables bunched together
(according to IEC 92-352).
These current ratings are applicable, with fair approximation, both for armoured and unarmoured cables. Where more than six bunched cables, simoultaneosly operating, are used, a
correction factor of 0.85 should be applied. For ambient temperatures different than 45 C a correction factors should be applied.

CURRENT RATINGS OF CONTINUOS SERVICE

CURRENT RATINGS OF CONTINUOS SERVICE


Nominal

Ambient temperature: 45 C

Nominal

Ambient temperature: 45 C

c.s.a.

Conductors temperature: 85 C

c.s.a.

Conductors temperature: 85 C

1 core

2 cores

3 cores

(mm2)

A)
(A

A)
(A

A)
(A

1
1.5
2.5
4
6
10
16
25
35

16
20
28
38
48
67
90
120
145

14
17
24
33
41
57
77
102
124

12
14
20
27
34
47
63
84
102

1 core

2 cores

3 cores

(mm2)

A)
(A

A)
(A

A)
(A

50
70
95
120
150
185
240
300
400

180
225
275
320
365
415
490
560
670

153
192
234
272
311
353
417
476
570

126
158
193
224
256
291
343
392
469

CORRECTION FSCTORS AT AMBIENT TEMPERATURES (ACCORDING TO IEC 60092-352)


Ambient temperature
Correction factors

35
1.12

40
1.06

45
1

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Reactance

REACTANCE AT 60 Hz AND VOLTAGE DROP FOR 3 CORE CABLES


Cross

Reactance

Volt drop

section
60 Hz

D. C.

A. C. single phase cos 0.8

A. C. three phase cos 0.8

(mm2)

(/km)

(mV/am)

(mV/am)

(mV/am)

1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185

0.13
0.12
0.11
0.10
0.099
0.093
0.089
0.090
0.088
0.088
0.086
0.084
0.084
0.084
0.085

45.4
30.4
18.6
11.6
7.73
4.59
2.89
1.83
1.32
0.972
00.673
0.485
0.384
0.311
0.249

36.5
24.4
15.0
9.38
6.31
3.79
2.42
1.57
1.16
0.884
0.644
0.491
0.411
0.354
0.305

31.6
21.1
13.0
8.12
5.45
3.28
2.09
1.36
1.00
0.764
0.557
0.425
0.356
0.306
0.264

Shipboard, catalogue
15

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD CABLES

SHIPBOARD

Symbols

16

Fire behaviour
According to: IEC 60332-1 flame retardant
IEC 60332-3 cat A fire retardant
IEC 60331 fire resistant
IEC 60332-3A/60331 fire retardant and fire resistant

Chemicals resistance
Outer sheath resistance to chemicals

Impacts
Cable mechanical resistance to impacts

low
Smoke density, corrosivity and toxicity
Low emission of smoke, acid and toxic gases:
IEC 61034 (smoke)
IEC 60754 (acid and toxic gases)

Temperature
Permissible minimum and maximum ambient
temperature

Severe weather conditions


Resistance to sun and rain

Bending radii
Minimum bending radius for installed cables

TPPC

SECTION

Instrumentation cables
for fixed installations in ships

Shipboard, catalogue
17

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Telecommunication and instrumentation cables


Collectively screened and unarmoured
Fire retardant according to
Cable designation

IEC 60332-3A

HFX-OSU 60 V

HFX-OSU 250 V

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (


class 5 only on request) of IEC 60228

Insulation:

HF-XLPE

Laying-up:

core lay-up in pairs, triples or quads, laying-up of pairs, triples or quads

Shield:

collective shield, aluminium/polyester tape with tinned copper stranded


drain wire and synthetic tape

Sheath:

SHF1
thickness according to IEC 60092-375 table II (0.50 mm2) or thickness
accord to IEC 60092-3 Amd. 1 table XVII 1st case ( 0.75 mm2)

Marking:

e. g. : TPPC HFX-OSU 60V pr/tr/qd x sect. - IEC 60332-3A

Standards applicable
IEC 60092-3
IEC 60092-375
IEC 60092-351
IEC 60092-359

Design guideline
Design guidelines
Insulating materials
Sheathing materials

Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

low
r

IEC 60332 - 3A
IEC 60331

SHF1: MODERATE
SHF2: GOOD

MODERATE

LOW EMISSION

-15 C
+75 C

SHF1: MODERATE
SHF2: GOOD

r = 6D

Overall shielded unarmoured cables

Table 1: 60 V, 0.50 mm2 cables

18

IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Table 2: 250 V, 0.75 mm2 cables

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

1x2x0,5
2x2x0,5
4x2x0,5
7x2x0,5
10x2x0,5
14x2x0,5
19x2x0,5
24x2x0,5
30x2x0,5

0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5

1,0
1,1
1,1
1,2
1,3
1,4
1,5
1,6
1,6

8,3
10,1
12,0
14,1
17,0
18,6
20,8
23,9
25,2

60
100
130
195
265
350
450
560
660

66
81
96
113
136
149
166
191
202

1x2x0,75
2x2x0,75
4x2x0,75
7x2x0,75
10x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
30x2x0,75

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,0
1,1
1,2
1,3
1,4
1,5
1,7
1,8
1,9

9,3
11,5
14,1
16,6
20,6
22,6
25,5
29,3
31,2

75
135
175
270
370
490
640
800
960

74
92
113
133
165
181
204
234
250

1x4x0,5

0,5

1,0

9,0

80

72

1x4x0,75

0,7

1,1

10,0

100

80

TPPC
Telecommunication and instrumentation cables
Collectively screened and unarmoured
Fire retardant according to

IEC 60332-3A

Table 3: 250 V, 1.0 mm2 cables

Table 4: 250 V, 1.5 mm2 cables

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

1x2x1,0
2x2x1,0
4x2x1,0
7x2X1,0
10x2x1,0
14x2x1,0
19x2x1,0
24x2x1,0
30x2x1,0

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,0
1,2
1,2
1,3
1,5
1,6
1,7
1,9
2,0

9,7
12,3
15,0
17,8
22,1
24,2
27,0
31,1
33,4

75
130
195
320
450
590
760
960
1180

78
98
120
142
177
194
216
249
267

1x2x1,5
2x2x1,5
4x2x1,5
7x2x1,5
10x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
30x2x1,5

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,0
1,2
1,3
1,4
1,6
1,7
1,8
2,0
2,1

10,3
13,1
16,2
19,4
24,3
26,6
29,7
34,3
36,7

90
160
250
415
590
780
1010
1270
1570

82
105
130
155
194
213
238
274
294

1x3x1,0
4x3x1,0
7x3x1,0
10x3x1,0
14x3x1,0
19x3x1,0

0,7
0,7
0,7
0,7
0,7
0,7

1,0
1,3
1,5
1,6
1,7
1,9

10,1
16,7
20,3
25,4
27,8
31,3

90
285
450
630
830
1100

81
134
162
203
222
250

1x3x1,5
4x3x1,5
7x3x1,5
10x3x1,5
14x3x1,5
19x3x1,5

0,7
0,7
0,7
0,7
0,7
0,7

1,1
1,4
1,5
1,7
1,8
2,0

11,0
18,3
22,1
27,9
30,6
34,4

115
370
580
840
1100
1480

88
146
177
223
245
275

1x4x1,0

0,7

1,1

10,5

120

84

1x4x1,5

0,7

1,1

11,5

150

92

Shipboard, catalogue
19

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Telecommunication and instrumentation cables


Individually and overall screened, unarmoured
Fire retardant according to

IEC 60332-3A

HFX-ISU 60 V

Cable designation

HFX-ISU 250 V

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 only on request) of IEC 60228

Insulation:

HF-XLPE

Laying-up:

core lay-up in pairs, triples or quads, laying-up of pairs, triples or quads

Shield:

individual (and collective on request) aluminium/polyester tape with tinned


copper stranded drain wire and synthetic tape

Sheath:

SHF1
thickness according to IEC 60092-375 table II (0.50 mm2) or thickness
according to IEC 60092-3 Amd. 1 table XVII 1st case ( 0.75 mm2)

Marking:

e. g. : TPPC HFX-ISOSU 60 V pr/tr/qd x sect. - IEC 600332-3A

Standards applicable
IEC 60092-3
IEC 60092-375
IEC 60092-351
IEC 60092-359

Design guidelines
Design guidelines
Insulating materials
Sheathing materials

IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

low
r

IEC 60332 - 3A

SHF1: MODERATE
SHF2: GOOD

MODERATE

LOW EMISSION

-15 C
+75 C

SHF1: MODERATE
SHF2: GOOD

r = 6D

Individual & overall or only individual shielded unarmoured cables


Table 5: 60 V, 0.50 mm2 cables

20

Table 6: 250 V, 0.75 mm2 cables

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

2x2x0,5
4x2x0,5
7x2x0,5
10x2x0,5
14x2x0,5
19x2x0,5
24x2x0,5
30x2x0,5

0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5

1,0
1,1
1,2
1,3
1,4
1,5
1,6
1,6

10,8
13,2
15,5
19,2
21,0
23,5
26,9
28,4

110
155
245
340
455
590
740
880

86
106
124
154
168
188
215
227

2x2x0,75
4x2x0,75
7x2x0,75
10x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
30x2x0,75

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,2
1,2
1,3
1,5
1,6
1,7
1,8
1,9

12,6
15,3
18,2
23,1
25,2
28,2
32,3
34,4

155
220
345
490
650
840
1040
1260

101
122
146
185
202
226
258
275

TPPC
Telecommunication and instrumentation cables
Individually and overall screened, unarmoured
Fire retardant according to

IEC 60332-3A

Table 7: 250 V, 1.0 mm2 cables

Table 8: 250 V, 1.5 mm2 cables

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs
or quads
x cross. sect.

Insulation
thickness

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(kg/km)

(mm)

2x2x1,0
4x2x1,0
7x2X1,0
10x2x1,0
14x2x1,0
19x2x1,0
24x2x1,0
30x2x1,0

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,2
1,3
1,4
1,5
1,6
1,8
1,9
2,0

13,1
16,2
19,4
24,3
26,6
30,1
34,3
36,6

165
250
390
540
720
960
1200
1460

105
130
155
194
213
241
274
293

2x2x1,5
4x2x1,5
7x2x1,5
10x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
30x2x1,5

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

1,2
1,3
1,4
1,6
1,7
1,8
2,0
2,1

14,0
17,4
21,0
26,6
29,1
32,6
37,5
39,9

190
300
475
680
910
1180
1500
1840

112
139
168
213
233
261
300
319

4x3x1,0
7x3x1,0
10x3x1,0
14x3x1,0
19x3x1,0

0,7
0,7
0,7
0,7
0,7

1,3
1,5
1,6
1,7
1,9

17,6
21,5
26,9
29,5
33,2

325
520
730
980
1300

141
172
215
236
266

4x3x1,5
7x3x1,5
10x3x1,5
14x3x1,5
19x3x1,5

0,7
0,7
0,7
0,7
0,7

1,4
1,6
1,7
1,8
2,0

19,3
23,4
29,4
32,2
36,3

415
670
940
1260
1660

154
187
235
258
290

Shipboard, catalogue
21

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Telecommunication and instrumentation cables


Collectively screened and armoured
Fire retardant according to
Cable designation

IEC 60332-3A

HFX-OSA/Cu 60 V

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 only on request) of IEC 60228

Insulation:

HF-XLPE

Laying-up:

core lay-up in pairs, triples or quads, laying-up of pairs, triples or quads

Shield:

collective shield, aluminium/polyester tape with tinned copper stranded


drain wire and synthetic tape

Inner covering:

synthetic tape(s)

Braid:

made of plain copper wire (on request, tinned copper) according to


IEC 60092-353 3.8

Sheath:

SHF1
thickness according to IEC 60092-375 table II (0.50 mm2) or thickness
according to IEC 60092-3 Amd. 1 table XVII 1st case ( 0.75 mm2)

Marking:

e. g. : TPPC HFX-OSA/Cu 60 V pr/tr/qd x sect. - IEC 60332-3A

Standards applicable
IEC 60092-3
IEC 60092-375
IEC 60092-351
IEC 60092-359

Design guidelines
Design guidelines
Insulating materials
Sheathing materials

22

IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

low
r

Overall shielded armoured cables

Table 9: 60 V, 0.50 mm2 cables

N. of pairs Insulation
or quads
thickness
x cross. sect.

HFX-OSA/Cu 250 V

Table 10: 250 V, 0.75 mm2 cables

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs Insulation
or quads
thickness
x cross. sect.

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

1x2x0,5
2x2x0,5
4x2x0,5
7x2x0,5
10x2x0,5
14x2x0,5
19x2x0,5
24x2x0,5
30x2x0,5

0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5

0,20
0,20
0,20
0,30
0,30
0,30
0,30
0,30
0,30

1,00
1,00
1,10
1,20
1,30
1,40
1,50
1,60
1,60

9,3
10,9
13,0
15,6
18,7
20,3
22,4
25,5
26,9

85
115
170
270
365
455
570
690
800

74
87
104
125
150
162
179
204
215

1x2x0,75
2x2x0,75
4x2x0,75
7x2x0,75
10x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
30x2x0,75

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,20
0,20
0,30
0,30
0,30
0,30
0,30
0,30
0,30

1,10
1,20
1,30
1,40
1,50
1,60
1,80
1,90
2,00

10,5
12,7
15,8
18,5
22,5
24,4
27,3
31,2
33,1

105
155
265
370
500
620
800
980
1140

84
102
126
148
180
195
218
250
265

1x4x0,5

0,5

0,20

1,00

10,0

105

80

1x4x0,75

0,7

0,20

1,10

10,5

125

84

TPPC
Telecommunication and instrumentation cables
Collectively screened and armoured
Fire retardant according to

IEC 60332-3A

Table 11: 250 V, 1.0 mm2 cables


N. of pairs Insulation
or quads
thickness
x cross. sect.

Table 12: 250 V, 1.5 mm2 cables

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs Insulation
or quads
thickness
x cross. sect.

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

1x2x1,0
2x2x1,0
4x2x1,0
7x2X1,0
10x2x1,0
14x2x1,0
19x2x1,0
24x2x1,0
30x2x1,0

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,1
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,1

10,9
14,0
16,8
19,7
24,0
26,0
28,9
33,0
35,3

115
205
305
435
580
740
930
1140
1380

87
112
134
158
192
208
231
264
282

1x2x1,5
2x2x1,5
4x2x1,5
7x2x1,5
10x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
30x2x1,5

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,4

1,1
1,3
1,4
1,5
1,7
1,8
1,9
2,1
2,2

11,5
14,8
18,0
21,3
26,2
28,4
31,6
36,4
39,1

135
240
365
530
740
940
1200
1500
1860

92
118
144
170
210
227
253
291
313

1x3x1,0
4x3x1,0
7x3x1,0
10x3x1,0
14x3x1,0
19x3x1,0

0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,3
0,3
0,3
0,3
0,3

1,1
1,4
1,6
1,7
1,8
2,0

10,3
16,9
20,5
25,6
28,0
31,5

135
385
570
790
1000
1280

82
135
164
205
224
252

1x3x1,5
4x3x1,5
7x3x1,5
10x3x1,5
14x3x1,5
19x3x1,5

0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,3
0,3
0,3
0,3
0,4

1,1
1,4
1,5
1,7
1,8
2,0

11,0
18,3
22,1
27,9
30,6
34,4

160
470
700
990
1260
1720

88
146
177
223
245
275

1x4x1,0

0,7

0,2

1,2

12,0

160

96

1x4x1,5

0,7

0,2

1,2

13,0

180

104

Shipboard, catalogue
23

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Telecommunication and instrumentation cables


Individually and overall screened and armoured
Fire retardant according to
Cable designation

IEC 60332-3A

HFX-ISA/Cu 60 V
HFX-ISOSA/Cu 60 V

HFX-ISA/Cu 250 V
HFX-ISOSA/Cu 250 V

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 only on request) of IEC 60228

Insulation:

HF-XLPE

Laying-up:

core lay-up in pairs, triples or quads, laying-up of pairs, triples or quads

Shield:

individual (and collective on request) aluminium/polyester tape with tinned


copper stranded drain wire and synthetic tape

Inner covering:

synthetic tape(s)

Braid:

made of plain copper wire (on request, tinned copper) according to


IEC 60092-353 3.8

Sheath:

SHF1
thickness according to IEC 600+375 table II (0.50 mm2) or thickness
according to IEC 60092-3 Amd. table XVII 1st case ( 0.75 mm2)

Marking:

e. g. : TPPC HFX-ISOSA/Cu 60 V pr/tr/qd x sect. - IEC 60332-3A

Standards applicable
IEC 60092-3
IEC 60092-375
IEC 60092-351
IEC 60092-359

Design guidelines
Design guidelines
Insulating materials
Sheathing materials

IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

low
r

IEC 60332 - 3A

SHF1: MODERATE
SHF2: GOOD

MODERATE

LOW EMISSION

-15 C
+75 C

SHF1: MODERATE
SHF2: GOOD

r = 6D

Individual & overall or individual only shielded armoured cables


Table 13: 60 V, 0.50 mm2 cables

N. of pairs Insulation
or quads
thickness
x cross. sect.

24

Table 14: 250 V, 0.75 mm2 cables

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs Insulation
or quads
thickness
x cross. sect.

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

2x2x0,5
4x2x0,5
7x2x0,5
10x2x0,5
14x2x0,5
19x2x0,5
24x2x0,5
30x2x0,5

0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5

0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3

1,2
1,2
1,3
1,4
1,5
1,6
1,7
1,8

12,2
14,4
17,2
21,1
22,9
25,4
28,7
30,5

165
220
355
475
600
760
930
1100

98
115
138
169
183
203
230
244

2x2x0,75
4x2x0,75
7x2x0,75
10x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
30x2x0,75

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3

1,2
1,3
1,4
1,6
1,7
1,8
1,9
2,0

13,6
17,0
20,1
24,9
27,1
30,1
34,1
36,2

170
300
420
630
760
1000
1190
1460

109
136
161
199
217
241
273
290

TPPC
Telecommunication and instrumentation cables
Individually and overall screened and armoured
Fire retardant according to

IEC 60332-3A

Table 15: 250 V, 1.0 mm2 cables


N. of pairs Insulation
or quads
thickness
x cross. sect.

Table 16: 250 V, 1.5 mm2 cables

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs Insulation
or quads
thickness
x cross. sect.

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

2x2x1,0
4x2x1,0
7x2X1,0
10x2x1,0
14x2x1,0
19x2x1,0
24x2x1,0
30x2x1,0

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,4

1,3
1,4
1,5
1,6
1,7
1,9
2,0
2,1

14,8
18,0
21,3
26,2
28,5
31,9
36,2
39,0

250
360
520
710
900
1160
1420
1780

118
144
170
210
228
255
290
312

2x2x1,5
4x2x1,5
7x2x1,5
10x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
30x2x1,5

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,3
0,3
0,3
0,3
0,3
0,3
0,4
0,4

1,3
1,4
1,5
1,7
1,8
2,0
2,1
2,2

15,7
19,3
22,8
28,4
30,9
34,7
39,9
42,3

285
420
620
860
1100
1420
1840
2180

126
154
182
227
247
278
319
338

4x3x1,0
7x3x1,0
10x3x1,0
14x3x1,0
19x3x1,0

0,7
0,7
0,7
0,7
0,7

0,3
0,3
0,3
0,3
0,3

1,4
1,6
1,7
1,8
2,0

19,5
23,3
28,8
31,3
35,1

435
650
900
1160
1500

156
186
230
250
281

4x3x1,5
7x3x1,5
10x3x1,5
14x3x1,5
19x3x1,5

0,7
0,7
0,7
0,7
0,7

0,3
0,3
0,3
0,3
0,4

1,5
1,6
1,8
1,9
2,1

21,1
25,1
31,3
34,1
38,7

530
800
1120
1440
1960

169
201
250
273
310

Shipboard, catalogue
25

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Telecommunication and instrumentation cables


Collectively screened and armoured
Fire retardant according to
IEC 60332-3A
Cable designation

Fire resistant according to

IEC 60331

HFX-OSA/Cu-FR 250 V

Construction
Conductors:

plain (on request tinned) annealed copper wires, according to class 2 (class
5 only on request) of IEC 60228

Insulation:

mica tape(s) + HF-XLPE

Laying-up:

core lay-up in pairs, triples or quads, laying-up of pairs, triples or quads

Shield:

collective shield, aluminium/polyester tape with tinned copper stranded


drain wire and synthetic tape

Inner covering:

halogen free compound


thickness according to IEC 60092-353 3.5.2

Braid:

made of plain copper wire braid (on request, tinned copper) according to
IEC 60092-353 3.8

Sheath:

SHF1
thickness according to IEC 60092-3 Amd. 1 table XVII 2nd case

Marking:

e. g. : TPPC HFX-OSA/Cu-FR 250 V pr/tr x sect. - IEC 60331


IEC 60332-3A

Standards applicable
IEC 60092-3
IEC 60092-375
IEC 60092-351
IEC60092-359

Design guidelines
Design guidelines
Insulating materials
Sheathing materials

IEC 60331
IEC 60332-1
IEC 60332-3A
IEC 60754-1, ..-2
IEC 61034-1, ..-2

Fire resistance
Flame retardance
Fire retardance on bunched cables
Halogen free properties
Low smoke emission

low
r

IEC 60332 - 3A

SHF1: MODERATE
SHF2: GOOD

MODERATE

LOW EMISSION

-15 C
+75 C

SHF1: MODERATE
SHF2: GOOD

r = 6D

Fire resisting overall shielded armoured cables

Table 17: 250 V, 1.0 mm2 cables

N. of pairs Insulation
or quads
thickness
x cross. sect.

26

Table 18: 250 V, 1.5 mm2 cables

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

N. of pairs Insulation
or quads
thickness
x cross. sect.

Armour
wire
diameter

Outer
sheath
thickness

Overall
diameter
maximum

Net
weight
approx

Bending
radius
minimum

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(nxnxmm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

1x2x1,0
2x2x1,0
4x2x1,0
7x2X1,0
10x2x1,0
14x2x1,0
19x2x1,0
24x2x1,0
30x2x1,0

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,20
0,30
0,30
0,30
0,30
0,30
0,30
0,30
0,40

1,20
1,30
1,40
1,50
1,60
1,70
1,90
2,00
2,10

13,7
16,9
20,4
23,8
28,6
30,9
34,4
39,5
42,4

270
390
560
770
1020
1250
1550
1970
2300

110
135
163
190
229
247
275
316
339

1x2x1,5
2x2x1,5
4x2x1,5
7x2x1,5
10x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
30x2x1,5

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7

0,20
0,30
0,30
0,30
0,30
0,30
0,30
0,40
0,40

1,20
1,40
1,40
1,60
1,70
1,80
2,00
2,10
2,30

14,3
18,1
21,6
25,5
30,8
33,4
37,6
43,2
45,9

300
450
670
920
1250
1530
1920
2470
2900

114
145
173
204
246
267
301
346
367

TPPC

Shipboard, catalogue
27

SHIPBOARD CABLES

Reference Design ST 104/1/620 of Pirelli Design Authority

SHIPBOARD

Instrumentation cables
General informations

28

Legend
Code
HFX*

halogen free cable XLPE insulation (stranded conductors cl. 2)

IS

pairs, triples individually shielded with aluminium/polyester

unarmoured

OS aluminium/polyester overall shielded

armoured (galvanized steel wire braid)

FR fire resistant (IEC 60331 750 C) cable

A/Cu

armoured (copper wire braid-plain or tinned)

* FHFX - for cables with flexible conductors cl.5.

Colour scheme in instrumentation cables


Identification of pairs/triples*
PAIR

Black

Blue

TRIPLE

Black

Blue

Brown

QUAD

Black

Blue

Brown

Grey (off-white) - Black


Black

Numbered 1-1-1, 2-2-2, 3-3-3, ...

* In multipairs/triples cables each cores, coloured as above, is numbered with the same number to identify the pair/triple.

DIMENSIONAL AND ELECTRICAL DATA OF CONDUCTORS, PAIRS, TRIPLES

Nominal

N. of wires

Wire

Conductor

Insulation

Core

Core diameter

cross section

minimum

diameter (*)

diameter (*)

average minimum

diameter (*)

(*) FR cables

(mm2)

(n)

(mm)

(mm)

(mm)

(mm)

(mm)

0.5
0.75
1
1.5

7
7
7
7

0.30
0.37
0.43
0.53

0.9
1.1
1.3
1.6

0.5(1)
0.7(2)
0.7(2)
0.7(2)

1.9
2.4
2.7
3

3
3.3

* Indicative value not subject to test.

(1)

According to IEC 60092-375 (60 V).

(2)

According to IEC 60092-3 (150/250 V).

Conductor size

(mm2)

0.50

0.75

1.00

1.50

Max. D. C. resistance at 20 C (plain)

(/km)

40.40

26.00

18.10

12.10

Max. D. C. resistance at 20 C (tinned)

(/km)

41.60

26.60

18.20

12.20

Overall shielded multipairs/triples

(nF/km)

70

70

80

85

Individually shielded pairs/triples

(nF/km)

75

75

85

90

Mutual capacitance (*)

* Indicative value.

TPPC
Instrumentation cables
General informations
Maximum shipping length and drum type
Cable diameter
(mm)

Nom. length
(m)

Drum type

12

3000

14

15

2000

14

20

1500

14

25

1500

16

30

1000

16

35

750

16

40

500

16

45

500

18

50

500

20

55

500

22

60

250

18

65

250

20

* In multipairs/triples cables each cores, coloured as above, is numbered with the same number to identify the pair/triple.

DRUMS: DIMENSIONS AND WEIGHT


Drum

D1

D2

L1

L2

type

D2 D1

L2
L1

06
07
08
09
10
12
14
16
18
20
22
22R
25
25S
26S
28S

Weight
approx

(mm)

(mm)

(mm)

(mm)

(kg)

630
710
800
900
1000
1250
1400
1600
1800
2000
2240
2240
2450
2450
2600
2800

315
355
400
450
500
630
710
900
1120
1250
1400
1300
1500
1250
1600
1600

410
495
545
566
676
740
870
1056
1316
1325
1325
1185
1325
1325
1365
1365

335
420
470
470
580
630
750
900
1140
1140
1140
1000
1140
1140
1140
1140

15
20
25
40
50
85
125
215
270
365
495
480
600
600
770
875

PALAZZO reserves the right to modify at any time the technical, dimensional and weight characteristics shown in this catalogue in case it improves the characteristics of their products.
There is no responsability of the manufacturer for damages to persons and property in case of improper use and/or neglecting the recommendations for using cables contained in IEC normes and
Standards or Regulations of various Classification Institutes.
Shipboard, catalogue
29

SHIPBOARD

Reference Design ST 104/1/620 of Pirelli Design Authority

30

SHIPBOARD CABLES

TPPC

Shipboard, catalogue
31

Reference Design ST 104/1/620 of Pirelli Design Authority

Tianjin Pirelli Power Cables Co., Ltd.


513, Huanghe Road Nankai District, Tianjin, Chian
Post code: 300112
tel. +86 022 275 39605
fax +86 022 275 14840