Академический Документы
Профессиональный Документы
Культура Документы
CABINET DESIGN
Compact 33" height
Standardized widths for easy coil fit
CONTROLS
Two stage gas valve
Self diagnostics saves last 5 fault codes regardless
of power interruption
INSTALLATION FEATURES
Left or right utility connections
Removable floor base for bottom return air
Zero step horizontal conversion
VENTING
Rotatable draft inducer for venting flexibility
WARRANTY
10 year limited parts warranty / lifetime
heat exchanger warranty available. See
limited warranty document for details.
80
UH
110
Revision
Code
20
Revision
80 = 80% Efficiency
08 = 2Ton add on cooling
12 = 3Ton add on cooling
16 = 4Ton add on cooling
20 = 5Ton add on cooling
G = Gas
2 = Two Stage
V = Variable Speed
UH = Upflow / Horizontal
A = 14.5" width
B = 17.5" width
C = 21.0" width
Upflow / Horizontal
Volts/
Hz/
Phase
Min.
Approx.
Time Nominal Trans. Shipping
Delay
(V.A.) Weight
Breaker F.L.A.
(lbs.)
or Fuse
Model
Input
(Btuh)
Output*
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
80G2UH070AV12
66,000
52,800
80.0%
3 tons
1/2
120-60-1
15
7.7
40
128
80G2UH090BV16
88,000
70,400
80.0%
4 tons
1/2
120-60-1
20
12.8
40
154
80G2UH110CV20
110,000
88,000
80.0%
5 tons
1/2
120-60-1
20
12.8
40
181
Note: For vent length and clearances to combustibles, please reference installation instructions.
* 1st Stage is 70% of shown capacities
** Capacities shown are 2nd Stage, 100% capacity
- Page 2 -
BOTTOM INLET
Heating
Cooling
Speed
Motor Blower Temp
CFM @ .50" w.c.
CFM @ .50" w.c..
Cooling
AdjustSize
Rise
Size
Setting Setting Setting Setting Stages ment Setting Setting Setting Setting
(hp)
F
40 - 70
80G2UH070AV12
1/2 HP
10 x 8
Upflow / Horizontal
25 - 55
40 - 70
80G2UH090BV16
1 HP
11 x 9
25 - 55
35 - 65
80G2UH110CV20
1 HP 11 x 10
25 - 55
1/2 HP
10 x 8
Upflow / Horizontal
40 - 70
1 HP
11 x 9
25 - 55
35 - 65
80G2UH110CV20
"B"
"C"
"D"
787
715
644
747
679
611
1187
1079
971
1096
996
896
1546
1405
1265
1431
1301
1171
990
900
810
829
754
679
1518
1380
1242
1136
1033
930
1935
1759
1583
1497
1361
1225
1027
934
841
926
842
758
1529
1390
1251
1398
1271
1144
1950
1773
1596
1783
1621
1459
1129
1026
923
1031
937
843
1646
1496
1346
1539
1399
1259
2175
1977
1779
1977
1797
1617
2nd
Stage
1st
Stage
2nd
Stage
1st
Stage
2nd
Stage
1st
Stage
+
Norm
+
Norm
+
Norm
+
Norm
+
Norm
+
Norm
"A"
"B"
"C"
"D"
995
920
820
735
690
650
1030
940
790
665
600
525
1535
1400
1260
1065
955
845
1080
985
905
785
735
685
1335
1200
1060
890
810
690
1705
1560
1395
1230
1085
960
1215
1105
995
865
795
755
1545
1405
1260
1035
960
850
1905
1710
1555
1355
1205
1075
1335
1225
1100
965
885
790
1755
1600
1435
1210
1090
985
2205
2015
1810
1560
1425
1265
Heating
Cooling
Speed
Motor Blower Temp
CFM @ .50" w.c.
CFM
@ .50" w.c.
Cooling AdjustSize
Rise
Size
Stages
Setting Setting Setting Setting
ment Setting Setting Setting Setting
(hp)
F
25 - 55
80G2UH090BV16
"A"
SIDE INLET
40 - 70
80G2UH070AV12
1 HP 11 x 10
25 - 55
"A"
"B"
"C"
"D"
778
707
636
740
673
606
1183
1075
968
1096
996
896
1505
1368
1231
1375
1250
1125
979
890
801
825
750
675
1522
1384
1246
1136
1033
930
1880
1709
1538
1455
1323
1191
1018
925
833
950
864
778
1533
1394
1255
1398
1271
1144
1925
1750
1575
1730
1573
1416
1114
1013
912
1044
949
854
1667
1515
1364
1539
1399
1259
2094
1904
1714
1903
1730
1557
- Page 3 -
2nd
Stage
1st
Stage
2nd
Stage
1st
Stage
2nd
Stage
1st
Stage
+
Norm
+
Norm
+
Norm
+
Norm
+
Norm
+
Norm
"A"
"B"
"C"
"D"
1010
926
820
735
689
635
1006
897
795
638
571
529
1506
1375
1235
1019
942
836
1097
1003
893
767
726
677
1296
1158
1049
901
778
698
1688
1526
1382
1160
1048
944
1218
1104
1013
848
795
727
1498
1346
1210
1013
930
809
1857
1687
1503
1286
1154
1020
1345
1213
1106
916
859
781
1672
1499
1406
1174
1040
956
2011
1843
1640
1420
1277
1116
Upflow / Horizontal
Dimensions
Model
80G2UH070AV12
14-1/2
13-3/8
13
4-3/4
80G2UH090BV16
17-1/2
16-3/8
16
6-1/4
80G2UH110CV20
21
19-7/8
19-1/2
- Page 4 -
Accessory List
Catalog Number
Description
External Filter Rack kits
1.841018
1.841039
68W76
2-Stage - 80
Return Air Base
68W61
14.5", A Width
68W62
17.5, B Width
68W63
21.0, C Width
Night Service Kits
68W81
Two-Stage
Horizontal Suspension Kit
51W10
Note: For vent length and clearances to combustibles, please reference installation instructions.
- Page 5 -
www.ducanehvac.com
1-800-448-5872
- Page 6 -