Вы находитесь на странице: 1из 6

VOLUMETRIC DETECTORS

The Urmet volumetric sensors enclose the best, most innovative intrusion alarm technologies. With solutions for all applications: passive infrared detectors, with interchangeable lens; movement sensors, passive infrared detectors; indoor motion detectors with double optical system; double element pyroelectric infrared detector for outdoor applications, with long or wide range coverage; passive flush-mounted infrared detectors. And finally, dual technology detectors (microwaves +infrared): elegant, reliable and with different ranges.

Detector types
- Passive detectors - Dual technology detectors - Outdoor detectors

224

VOLUMETRIC DETECTORS
Standard passive infrared detector
1033/110 1033/111 1033/125
1033/110
Passive IR detector with pet immunity function. IMQA Level 1 Suitable for ensuring reliable protection in presence of small pets. Passive infrared sensor with joint. IMQA Level 1 Ceiling mounted passive sensor

MAIN CHARACTERISTICS
1033/110
Power Max. consumption 9 - 15 Vdc 13 mA x1/x2 15 m from 1.6 to 1.9 m from 18 to 35 kg selectable NC 100 mA@24V

1033/111
9 - 15 Vdc 16 mA x1/x2 12 m from 1.6 to 2. m NC 100 mA@24V

1033/125
9 - 15 Vdc 20 mA

1033/111

Pulse count Range Recommended install. height Pet discrimination Alarm relay Tamper protection Weight Dimensions (W x H x D) mm

from 2. to 5 m NC 100 mA@24V

80 g 70 x 85 x 54

100 g 70 x 85 x 54

90 g 120 x 32

Yes.

225

WIRED INTRUSION ALARM SYSTEMS

VO LU M E T R I C D E T E CTO R S

Dual technology detectors


1033/115 1033/135
Dual technology detector. IMQA Level 1 Anti-masking dual technology detector. IMQA Level 1

MAIN CHARACTERISTICS
1033/115
Power Range AND/OR function Synchronism function Masking function Synchronism input

1033/115
12 Vdc 15 m Selectable -

1033/135
12Vdc 15 m Selectable

1033/135

Masking output Alarm output Tamperproof output IMQA type approval Dimensions (W x H x D) mm


Level 2 if joint 1033/139 is used 70 x 124 x 54

(max. 3 detectors)
Level 2 if joint 1033/139 is used 70 x 124 x 54

Yes. 226

W I R E D I N T R U S I O N A L A R M SY S T E M S

Outdoor detectors
1033/138
Outdoor triple technological detector Suitable for protecting the perimeter of the home. It is advisable to install in position protected from weather elements. Outdoor duel element pyroelectric element infrared detector Suitable for protecting the perimeter of the home. Double asymmetric coverage of 12 m per side.

1033/149
1033/138

MAIN CHARACTERISTICS
1033/138
Power Range 9 - 15 Vdc 12 m 20 mA -

1033/149
10 - 28 Vdc 24 m (12 m per side) 28 mA 4 (2 zones per side) 2 (NO - NC) -

1033/149

Consumption Detection zones Pulse count Relay output Pet immunity function Tampering Siren output Test mode Degree of protection Dimensions (W x H x D) mm

1 35 kg

IP43 75 x 152 x 55

70 dB at 1 m ON/OFF IP55 55 x 233 x 69

ACCESSORIES FOR VOLUMETRIC DETECTORS


1033/139
1033/139
Joint for detectors 1033/115 and 1033/135 Using joint with tamper kit detectors 1033/110, 1033/111, 1033/115 and 1033/135 are level 2 IMQA. Set of 5 microswitches Tamper microswitch for 1033/139 joint. Set of 5 curtain lenses Lens for volumetric sensor 1033/111. Set of 5 long range lenses Lens for volumetric sensors 1033/111, 1033/115 and 1033/135. - 30 m range for infrared sensor 1033/111 only - 15 m range for dual-technology sensors 1033/115 and 1033/135.

1033/140 1033/667 1033/668

1033/140

Yes.

227

WIRED INTRUSION ALARM SYSTEMS

PERIMETER BARRIERS

For who has a security system, the boundary between security and total security is far from negligible. Urmet technology offers a series of perimeter barriers implementing sophisticated, innovative technology for putting a stop to intrusion problems in open spaces. The devices consist of a modulated infrared light transmitter and a receiver: interrupting the infrared beam emitted by the transmitter generates the alarm. These barriers are widely used for protecting lofts, balconies, courtyards and external fencing. Synchronised curtains must be used for installation with more than two active infrared beams.

Active infrared sensors


1033/190 1033/293
Active synchronised infrared sensor, 50 m range Active synchronised double beam infrared sensor, 150 m range Suitable for external protection, and installed in die-cast aluminium column or in places protected from the weather elements.

Note: avoid installation in locations in which visibility may be reduced to 70% by fog.

1033/190

MAIN CHARACTERISTICS
1033/190
Power Range Consumption 12 - 24 Vdc 50 m 60 mA Modulated infrared beams NC 1A@24Vdc

1033/293
10 - 28 Vdc 150 m 80 mA Modulated infrared beams NO/NC 200mA@30Vdc NO/NC 200mA@30Vdc Automatically adapting From -25C to +55C IP55 100 x 247 x 100

1033/293

Detection system Alarm relay output Tamperproof output Cut-out tripping Working temperature range Degree of protection Dimensions (W x H x D) mm

Adjustable From - 20C to + 70C 60 x 127 x 55

Yes. 228

W I R E D I N T R U S I O N A L A R M SY S T E M S

Multiplexed barriers
1033/282 1033/283 1033/284 1033/285
1033/282
Synchronised multiplexed barriers. Height 0.50 m. IMQA level 2 Synchronised multiplexed barriers. Height 1 m. IMQA level 2 Synchronised multiplexed barriers. Height 1,50 m. IMQA level 2 Synchronised multiplexed barriers. Height 2 m. IMQA level 2

MAIN CHARACTERISTICS
1033/282
Power Indoor range Outdoor range Tx alarm consumption Rx alarm consumption 12Vdc 20 m 10 m 47 mA 18 mA 2 100 mA@24Vdc 50 mA@12Vdc -25C - +55C 250 g 25 x 540 x 23

1033/283
12Vdc 20 m 10 m 73 mA 24 mA 4 100 mA@24Vdc 50 mA@12Vdc -25C - +55C 500 g 25 x 1.030 x 23

1033/284
12Vdc 20 m 10 m 99 mA 30 mA 6 100 mA@24Vdc 50 mA@12Vdc -25C - +55C 750 g 25 x 1.520 x 23

1033/285
12Vdc 20 m 10 m 127 mA 36 mA 8 100 mA@24Vdc 50 mA@12Vdc -25C - +55C 1,000 g 25 x 2.020 x 23

1033/283

Beams Alarm relay output Tamperproof output Working temperature range Weight Dimensions (W x H x D) mm

1033/174
1033/284

Aluminium column H = 100 cm - Height: 100 cm - Thermostat kit included - Cut-out circuit included - Tamperproof device included Aluminium column H = 150 cm - Height: 150 cm - Thermostat kit included - Cut-out circuit included - Tamperproof device included Aluminium column H = 200 cm - Height: 200 cm - Thermostat kit included - Cut-out circuit included - Tamperproof device included Fixing base Suitable for fitting to anodized aluminium columns 1033/174/175/176/177 Wall bracket Suitable for fitting to anodized aluminium columns 1033/174/175/176/177 Support kit for 1033/190 barrier

1033/175

1033/176

1033/177 1033/178
1033/285

1033/173

229

WIRED INTRUSION ALARM SYSTEMS

ACCESSORIES