Вы находитесь на странице: 1из 18

HUAWEI BTS3900 Cabling Guide Standard

www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Introduction to 3900 series

BTS3900 GSM

BTS3900A GSM

DBS3900 GSM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page1

Structure of the BTS3900 Cabinet

1) Double radio filter unit 2) Fan box 3) GSM antenna and TMA control module 4) Baseband unit 5) Direct current distribution unit

-48V Cabinet
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page2

Structure of the BTS3900 Cabinet

(1) Double radio filter unit (2) Fan box (3) Baseband unit (4) Direct current distribution unit (5) Cable in/out unit (6) Power supply unit

+24V or +220V Cabinet


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page3

BBU

The typical power consumption of BBU is 35W


The weight of the BBU is 12 kg at most. All the boards can be inserted from the front panel The Permissible range of power input is 38.4 V DC to 57 V DC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page4

Boards and Modules in BBU


BSBC: The universal BBU subrack backplane type C GTMU: The GSM Transmission, Timing and Management Unit UBFA: The universal BBU fan unit type A UPEU: The universal power and environment interface unit UELP: The universal E1/T1 lightning protection unit
UEIU: The universal environment interface unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page5

GTMU

Controls, maintains, and operates the BTS


Monitors the fan module and the power supply module in the BBU Distributes and manages BTS clock signals Provides the Ethernet port for terminal maintenance Supports four E1 inputs & Ethernet port for transmission. Provides the CPRI ports for communication with the DRFU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page6

GTMU Ports
Port CPRI0 CPRI5 Type DLC Corresponding Cable Optical fiber between BBU and DRFU Description Connected to DRFU for the optical signal transmission

ETH FE0
FE1

RJ45 RJ45
DLC

Special Ethernet cable Ethernet cable


Optical fiber

Terminal maintenance and commissioning A reserved port that performs the following
function: Connects the BBU to a routing device in the equipment room through the

Ethernet cable for transmission


USB USB A reserved port that performs the following

function: Automatically upgrades the


software through the USB disk TEST E1/T1 USB DB26 male BBU E1/T1 Tests the output clock signals with a tester Provides the input and output of the four E1/T1 signals between the GTMU and the UELP or between the GTMU and the BSC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page7

UBFA

The universal BBU fan unit type A (2U) (UBFA) works with the air inlet box of the cabinet to form a ventilation circuit, thus cooling the entire cabinet The UBFA module communicates with the GTMU to regulate the

temperature, adjust the fan speed, and report alarms. The UBFA module is hot swappable
Indicato r Color Green Status Fast flash(0.25s on0.25s off)
Description

STATE

Can not communicate with the board and there is no alarm generated

Red Green

On Slow flash(1s on, 1s off)

There is alarm Runs normally

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page8

UPEU

The universal power and environment interface unit type A (48 V)


(UPEU) supports the 48 V DC power input, supplies power to the boards, modules, and fan in the BBU, and provides access to multiple

environment monitoring signals Port

Type

Description Provides the input and output of the externally collected environment monitoring signals to the GTMU according to the RS485 communications protocol Same as MONO0 Transmits the externally collected environment monitoring signals to the GTMU through communications protocol related to the dry contact Same as EXT-ALM0

MON0 RJ45

MON1 RJ45 EXTALM0 RJ45

EXTALM1

RJ45

PWR

3V3

-48V DC input
Page9

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

UEIU

UEIU is the environment interface board of BBUit can support


multi-route monitoring signal input UEIU is optional and is only used when more ports are needed
Port Type
Description
Provides the input and output of the externally collected environment monitoring signals to the GTMU according to the RS485 communications protocol

MON0 RJ45

MON1 RJ45
EXTALM0 RJ45

Same as MONO0.
Transmits the externally collected environment monitoring signals to the GTMU through communications protocol related to the dry contact Same as EXT-ALM0.

EXTALM1

RJ45

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page10

UELP

UELP is the E1/T1 signal lightening protection unit of BBU and


it can provide protection for 4 route E1/T1 signal

Port INSIDE

Type DB25 male

Relative cables E1 transferring cable E1/T1 cable

Description Transfers the four E1/T1 signals between the UELP and the GTMU Provides the input and output of the four E1/T1 signals between the BBU and the BSC
Page11

OUTSIDE

DB26 male

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

BBU Cables

Grounding cable, -48DC power cable, E1/T1 cable, E1 transferring

cable, main node alarm signal cable, FE port cable, CPRI port signal cable and transmission cabinet monitoring cable

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page12

DCDU Panel

a: Power switch

b: Power output ports


Page13

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Ports of the MRFU


Type Port for transmitting and receiving RF signals CPRI port Connector N female connector Ports
ANT_TX/RXA

Description Used in connection to the antenna subsystem

ANT_RXB

SFP female connector

CPRI0

Used in connection to the BBU, or in connection to the upper-level cascaded MRFU

CPRI1 Port for transmitting RF signals between MRFUs


Power port

Used in connection to the lower-level cascaded MRFU Input port for diversity signals in antenna channel 1 Output port of diversity signals in antenna channel 1
Receives power input

QMA female connector

RX1 in RX1 out

7W2 power connector

PWR

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page14

Cable Connection of -48V Cabinet


Cable Number R1-R12 P1-P2 P3-P8 RF Jumpers External Power Cables (-48 V) Power Cables Between the DCDU and DRFUs Cable Name Qua ntity 12 2 6

P9
P10 P11-P12

Power Cable Between the DCDU and Fan Box


Power Cable Between the DCDU and BBU Reserved

1
1 2

S1-S6 S7
S8 S9

CPRI Signal Cables Between the BBU and DRFU E1 Transfer Cable of the BBU
Monitoring Signal Cables for the DCDU Monitoring Signal Cable for the Fan Box

6 1
1 1

S10

E1/T1 Cable of the BBU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page15

MRFU Topologies Configuration

The MRFU supports various network topologies: star, chain, and ring

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page16

Thank you
www.huawei.com

Вам также может понравиться