Вы находитесь на странице: 1из 46

SafidRectangular

Safid Rectangular

Benefits Of Safid Rectangular


Assembly Instruction

Safid Rectangular Contents

SafidRectangular
CONTENTS
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Type
Rectangular Ducts

Page
SD ........................................... 7 SDL ......................................... 8 SDS ......................................... 9 SDT ....................................... 10

Product
Split Bend

Page
SE ........................................... 19

Reducer

RED ....................................... 12

Transition

TRANS .................................... 20

Bends

RE ......................................... 13 REV ....................................... 14 SQ ......................................... 15

Branch Connections/Take off TO 45 ..................................... 21 TO 90 ..................................... 22 LYT ......................................... 23 LKT ......................................... 24 SFL ......................................... 25 SFLD ...................................... 26 SFLDE .................................... 27 Installation ............................. 28

Tee

TSR ....................................... 16

Splitter Damper SPL ......................................... 29 Air Extractor SAE ......................................... 30 Turning Vanes/Splitter Vanes TVL/TVS ................................. 31 SV ........................................... 32

8 3
Offset OFF ....................................... 17 Construction Scheduels .......................................... 35-45

R-Fitting

RF .......................................... 18

Specifications

................................................ 46

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular

Benefits of the
Factory fabricated and assembled, ready for installation with complete range of rectangular products.

General

SafidVent

SafidRectangular

Safid Double Wall

Lindab Transfer

Lindab Safe

system

Factory applied sealant on all longitudinal seams and transverse seams in case of flanged duct for all pressure systems.

SafidOval

8 4
Safid Flexible

SafidOval Double Wall

State of the art identification system on duct pieces cross-referenced to drawings for an easy installation procedure and follow up.

Virtually any size of duct can be constructed. (No limitation, to standard manufacturer sizes).

Notes Standards

Quick and easy installation in case of flanged ducts without the use of special tools.

Products & Accessories

Lindab Comfort

Can be supplied with internal acoustic lining and double wall construction (thermal & acoustic).
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular

Right to alterations reserved.


SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent General

is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

Safid Flexible

8 5

SafidRectangular
Assembly Instructions
General

Description
SafidRect must be assembled according to these instructions BEFORE ASSEMBLY The ducts must be free from dirt. Assembly instructions: Only use undamaged SafidRect duct and fittings. Apply continuous gasket to effectively seal flanges and corners. Fasten the duct and fitting together with bolts & nuts at four corners. Mating flange shall be locked together by duct clamps spaced at centers not exceeding 200mm.

Lindab Transfer

Lindab Safe

SafidVent

Safid Double Wall

The following numbers of duct clamps are recommended:

SafidOval

duct dimension mm 0 - 200 250 - 400 450 - 600 650 - 800 850 - 1000 1050 - 1200 1250 - 1400 1450 - 1600 1650 - 1800 1850 - 2000 2050 - 2200

number 0 1 2 3 4 5 6 7 8 9 10

8 6
Safid Flexible Lindab Comfort Products & Accessories Notes Standards

SafidOval Double Wall

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Straight Ducts
SD

SD
General

Description
Safid single wall duct & fittings are factory fabricated and supplied with factory applied sealant on all longitudinal joints for S & Drive slip ducts and additionally on transverse joints for all flanged end ducts & fittings. SafidRect can be supplied either fully assembled form or knocked down form for straight ducts (minimum requirement for assemble of straight ducts on site) fittings will be delivered fully assembled with factory applied sealant. SafidRect can be supplied in various materials: - G, galvanized steel (in accordance with ASTM 653, G90 coating) - H, stainless steel (in accordance with ASTM A240/480 and various material grades) - A, aluminum metal (in accordance with ASTM B209, type alloy 3003, H14) - P, painted galvanized steel (as G, but with various paint system i.e. epoxy...)

Dimensions
All straight ducts are beaded or cross broken (except if duct is double wall, internally lined, negative pressure, Ga.18 ducts, and 4" w.g. or above) and fittings are cross broken from size 483 mm and above.

Beads at 210 mm equal spacing First bead 150 mm (max.) from ends.

H L W

Ordering
Product code: Type W mm H mm L mm SD aaa bbb - ccc Beaded Duct

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

Safid Flexible

SafidOval Double Wall

Standard duct length : 1200 mm (4 feet)

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 7

SafidRectangular
Lined Ducts
General

SDL

SDL

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

Description
Safid lined rectangular duct and fittings are available with an insulating liner coated with black glass tissue to protect against erosion and microbial growth. This acoustic/thermal liner can be used with air velocities up to 5,000 fpm. Standard length is 1200 mm. Standard acoustic/thermal insulation : 25mm, 48 kg/m3, BGT facing. Other thickness and density can be supplied on request. Insulation edge coverings : all insulation edges are covered by galv.steel channels fixed to duct.

Ordering
Product code: Type W mm H mm L mm SDL aaa bbb - ccc

8 8
Safid Flexible

SafidOval Double Wall

SafidOval

Dimensions
Duct Liner Clip Pin

Liner bonded to duct with adhesive and welding pins at approximate centers as shown.

Notes Standards

26 Gauge Liner Duct Insulation Guard as a Standard

Products & Accessories

Dimensions Velocity 0 - 2500 fpm 2501 - 5000 fpm A 76 76 B 305 152 C 102 102 E 457 406

Lindab Comfort

Liner to be 48 kg/m3, (3 lbs/ft3) density, 25 mm thick, unless otherwise specified.

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Double Wall Acoustic Ducts
SDS

SDS
General

Description
Safid double wall rectangular duct and fittings provide exceptional noise control in air distribution systems. Ordering This double-wall, insulated ductwork is constructed of Product code: solid metal outer shell and perforated inner shell with a layer of acoustic insulation sandwiched between. Type Our standard construction is: galvanized steel with a W mm galvanized perforated inner wall and standard acoustic, H mm thermal insulation of 25 mm tickness, 48 kg/m3 density, L mm with BGT facing. Other types of insulation material, density & thickness are avialable. As for the outer shell can be supplied in galvanized steel, stainles steel, black steel, aluminum or painted steel while for the inner perforated shell only in galvanized steel or black steel. Standard length is 1200 mm.

Dimensions
Tack Weld
Safid Flexible

Perforated Galv. Steel Insulation

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

SafidOval Double Wall

SafidOval

SDS -

aaa

bbb - ccc

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 9

SafidRectangular
Double Wall Thermal Ducts
General

SDT

SDT

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

Description
Safid double wall rectangular duct and fittings provide exceptional thermal control in air distribution systems and is ideal for external and roof ducts applications. This double wall, insulated ductwork is constructed of solid metal outer shell and solid inner shell with a layer of insulation sandwiched between. Our standard construction is: galvanized steel (solid) inner and outer shell. several types of insulation material, densities & thickness are available. As for the outer and inner shell can be supplied in galvanized steel, black steel, aluminum, stainless steel and painted steel. Standard length is 1200 mm.

Ordering
Product code: Type W mm H mm L mm SDT aaa - bbb ccc

8 10
Safid Flexible

SafidOval Double Wall

SafidOval

Dimensions

Tack Weld

Notes Standards

Solid Galv. Steel Insulation

Products & Accessories

Lindab Comfort

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Longitudinal Seams
General

Pittsburgh Lock

Double Corner Seam

* 18 Gauge & Up

* Up to 20 Gauge
SafidOval

ACME Lock

Seam Location

For Ducts Length L > 1200 mm

B
Safid Flexible

Seam Location

* Seam numbers and locations vary according to joint type and size.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

SafidOval Double Wall

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 11

SafidRectangular
Reducer
General

RED
Description
Reducer

RED

SafidVent

Ordering
Product code: Type W1 mm H1 mm W2 mm H2 mm L mm RED - aaa - bbb - ccc - ddd - eee

Safid Double Wall

Lindab Transfer

Lindab Safe

Dimensions

SafidOval Double Wall

SafidOval

20 Maximum on Diverging Flow W2 Air Flow H2

8 12
H1
Safid Flexible

L
Notes Standards

W1

30 Maximum on Contracting Flow

Air Flow
Products & Accessories Lindab Comfort

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Radius Bend
RE Description
Radius bend without splitter vanes Throat radius R = W (width).

RE
General

Product code: Type W mm H mm R mm

RE

aaa

bbb - ccc

*R = W
Safid Double Wall

Dimensions

H R

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

Safid Flexible

SafidOval Double Wall

SafidOval

Lindab Transfer

Lindab Safe

Ordering

SafidVent

8 13

SafidRectangular
Radius Bend with Splitter Vanes
General

REV

REV

Description
Radius bend with splitter vanes Throat radius R is less than W (width).

SafidVent

Lindab Safe

Ordering
Product code: Type W mm H mm R mm Splitter vane 1mm Splitter vane 2mm REV - aaa - bbb - ccc - S1 - S2

Safid Double Wall

Lindab Transfer

*For splitter vanes refer to page 8/32.

Dimensions

SafidOval Double Wall

SafidOval

8 14
Safid Flexible Notes Standards

H R

Products & Accessories

S2 S1

Lindab Comfort

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Square Throat Bend with Turning Vanes
SQ Description
Square throat bend with turning vanes Standard square Throat length N = 100mm.

SQ
General

Product code: Type W mm H mm R mm

SQ

aaa

bbb

- ccc

N = Throat, Safid standard is 100 mm but can vary. * For turning vanes refer to page 8/31.

Dimensions

H
Products & Accessories
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.

Lindab Comfort

Notes Standards

Safid Flexible

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

Ordering

SafidVent

8 15

SafidRectangular
Tee
General

TSR
Description
Tee.

SafidVent

Ordering
Product code: TSR - aaa - bbb - ccc -ddd - eee - fff - ggg Type W1 mm H1 mm W2 mm H2 mm W3 mm H3 mm

Lindab Transfer

Lindab Safe

* N = Throat, Safid standard is 100 mm but can vary. *For splitter vanes refer to page 8/31.

Safid Double Wall

Dimensions

SafidOval

H3

SafidOval Double Wall

W3

8 16
Safid Flexible

W2
Notes Standards

H2

Products & Accessories

W1

Lindab Comfort

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Offset
OFF Description
Offset.

OFF
General

Ordering
Product code: Type W mm H mm O mm L mm OFF - aaa - bbb - ccc - ddd

Dimensions
15 Max. W W W O Offset Type 1 (Angled)

60 Max. W W W Offset Type 2 (Mitered)

/4
1

/2
Products & Accessories Lindab Comfort

Throat Radius minimum 6 (150 mm)

/4

Offset Type 3 (Radiussed or ogee)

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Notes Standards

Safid Flexible

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 17

SafidRectangular
R-Fitting
General

RF
Description
R-Fitting or parallel flow branches.

RF

SafidVent

Ordering
Product code: RF - aaa - bbb - ccc - ddd - eee - fff - ggg Type W1 mm H1 mm W2 mm H2 mm W3 mm H3 mm R mm

Safid Double Wall

Lindab Transfer

Lindab Safe

Dimensions

SafidOval

W1
SafidOval Double Wall

H1

8 18
Safid Flexible

H3 H2

Notes Standards

W2

Products & Accessories

W3

Lindab Comfort

Can be supplied with splitter damper upon request. All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Split Bend
SE Description
Split Bend.

SE
General

Ordering
Product code: Type W1 mm H1 mm W2 mm H2 mm W3 mm H3 mm R1 mm R2 mm SE - aaa-bbb-ccc-ddd-eee -fff - ggg-hhh

Dimensions
H3

W3

R1
Safid Flexible

W2
Notes Standards Lindab Comfort Products & Accessories
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

R2 W1

H2

Can be supplied with splitter damper upon request. All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 19

SafidRectangular
Transition, rectangular to round
General

TRANS

TRANS

Description
Transition, rectangular to round.

Lindab Safe

SafidVent

Ordering
Product code: Type W mm H mm mm L mm TRANS - aaa - bbb - ccc - ddd

Safid Double Wall

Lindab Transfer

Dimensions

SafidOval Double Wall

SafidOval

8 20
Safid Flexible

Notes Standards

Lindab Comfort

Products & Accessories

All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Branch Connection / Take Off
TO 45 Description
45 Rectangular Branch Connection / Take Off.

TO 45
General

Ordering
Product code: Type W mm H mm L mm TO 45 aaa bbb - ccc

Dimensions

L Sealant Fixing by rivets or self tapping screw

25

H Straight Tap as a Standard

W Sealant Clinch Lock or Dove Tail as Optional

25

L = 1/4 W, Min. 100 mm

Application of sealant after installation is recommended. Can be supplied with splitter damper upon request. All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

Safid Flexible

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 21

SafidRectangular
Branch Connection / Take Off
General

TO 90

TO 90

Description
90 Rectangular Branch Connection / Take Off.

Lindab Safe

SafidVent

Ordering
Product code: TO 90 aaa bbb ccc Type W mm H mm L mm

Safid Double Wall

Lindab Transfer

Dimensions

SafidOval Double Wall

SafidOval

Sealant Fixing by rivets or self tapping screw

8 22
H
Safid Flexible

25

Straight Tap as a Standard

W Sealant
Notes Standards

25

Clinch Lock or Dove Tail as Optional

Products & Accessories

L = 100 mm

Application of sealant after installation is recommended. Can be supplied with splitter damper upon request. All fittings are available with acoustic lining or double wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

SafidRectangular
Branch Connection / Take off
LYT Description
Round Branch Connection/Take Off - Flanged

LYT
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Ordering
Product code: Type D mm LYT aaa

Dimensions

L Sealant Fixing by rivets or self tapping screw

8 23

12

Flanged

L = 85 mm

Application of sealant after installation is recommended. For "D" dimensions see flexible duct sizes or SafidVent for spiral duct dimensions. All fittings are available with Double Wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Branch Connection / Take off
General

LKT

LKT

Description
Round Branch Connection/Take off - Conical

Lindab Safe

SafidVent

Ordering
Product code: LKT aaa Type D mm

Safid Double Wall

Lindab Transfer

Dimensions

SafidOval Double Wall

SafidOval

Sealant

8 24
Safid Flexible

12

Fixing by rivets or self tapping screw

Flanged

Products & Accessories

Notes Standards

L = 118 mm

Application of sealant after installation is recommended. For "D" dimensions see flexible duct sizes or SafidVent for spiral duct dimensions. All fittings are available with Double Wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

SafidRectangular
Branch Connection / Take Off
SFL Description
Round Branch Connection/Take Off - Spin - in

SFL
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Ordering
Product code: Type D mm SFL bbb

Dimensions

Sealant Spin - In

8 25

L = 85 mm

Application of sealant after installation is recommended. For "D" dimensions see flexible duct sizes or SafidVent for spiral duct dimensions. All fittings are available with Double Wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Branch Connection / Take Off
General

SFLD

SFLD

Description
Round Branch Connection/Take Off - Spin - in with Damper.

Lindab Safe

SafidVent

Ordering
Product code: SFLD aaa Type D mm

Safid Double Wall

Lindab Transfer

Dimensions

SafidOval Double Wall

SafidOval

Sealant L

8 26
Safid Flexible

Spin - In

Notes Standards

Standard Dimensions Dia. Range (D) (mm) 80 - 315 Length (L) (mm) 150

Products & Accessories

Lindab Comfort

Application of sealant after installation is recommended. For Pressure Loss and Installation Details, refer to page 8/28. All fittings are available with Double Wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Branch Connection / Take Off
SFLDE Description
Round Branch Connection/Take Off - Spin - in with Damper and Scoop.

SFLDE
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Ordering
Product code: Type D mm SFLDE - aaa

Dimensions

Spin - In

8 27

Standard Dimensions Dia. Range (D) (mm) 80 - 315 Length (L) (mm) 150

Application of sealant after installation is recommended. For Pressure Loss and Installation Details, refer to page 8/28. All fittings are available with Double Wall construction.
Right to alterations reserved.
is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Branch Connection / Take Off
General

Installation Instruction
1. Cut correct inner diameter hole.

SafidVent

2. Cut slot in hole edge. (in case of spin-in take off) 3. Insert collar notch into cut slot (in case of spin-in take off) 4. Twist in one full turn (in case of spin-in take off) or fix by riveting (in case of flanged spin-in).

Safid Double Wall

Lindab Transfer

Lindab Safe

Installation Details - Spin - in & Flanged Take Off


Duct Nylon or Metal Clamps (QIP Clamps) Spin-in Duct

SafidOval

Sealant

SafidOval Double Wall

Flanged Rivet

8 28
Safid Flexible

Flexible Duct

Duct

Sealant

Technical Data
Pressure Loss
V (m/s)

15

Notes Standards

10 9 8 7 6 5 4

=0 15 30

Products & Accessories

3 2

45

75

90

Lindab Comfort

10
V P

20

30 40 50

70

100

200

300 400 500 700

1000

= air speed in the duct = pressure loss in each position of the air damper

P (Pa)

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Splitter Damper
Splitter Damper
Piano Hinge

SPL
General
Blade
Ai rF lo

Ball Joint

Control Rod

Aerofoil Blade Splitter Damper

Dimensions
W2 x D2

Bracket

Piano Hinge

W3 x D3 R2 R1 R1 = 3/4 W3 R2 = A + R1

B A W1 x D1

Splitter Damper Length is Equal to 1.5 A Where: A = 100 mm Min.

(W3 x D3) A= (W2 x D2) + (W3 x D3) Bracket Piano Hinge (W2 x D2) (W2 x D2) + (W3 x D3) W1

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

One rod up to 610 mm depth (D1) Two rods 635 mm to 1525 mm depth (D1) Three rods above 1525 mm depth (D1)

Products & Accessories

B=

W1

Notes Standards

Safid Flexible

Single Blade Splitter Damper (Standard)

Trunk may be divided using:

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 29

SafidRectangular
Air Extractor
General

SAE
Description
Air Extractor.

Air Extractor

Lindab Transfer

Lindab Safe

SafidVent

Safid Double Wall

Ordering
Product code: Type W mm H mm SAE aaa bbb

SafidOval

Dimensions

8 30
Safid Flexible

SafidOval Double Wall

Rod
Notes Standards

Ball Joint

Products & Accessories

100

Lindab Comfort

W-10 x H-10 WxH Listed Size

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Turning Vanes
Vanes Types & Schedule

TVS/TVL
General
S S 45 R 45 R

Dimensions

45

45

Duct Size

Double Vane Schedule Type R 50 115 S 54 83 Ga 26 24

Duct Size

Single Vane Schedule Type R 50 115 S 38 83 Ga 24 22

0-1000 Small 1000 Up Large

0-900 Small 900 Up Large

* 1500 Up Segmented

* 1500 Up Segmented

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

Products & Accessories

Notes Standards

Safid Flexible

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

8 31

SafidRectangular
Splitter Vanes
General

SV
2540 2290 2030 1780 1520 1270 1020

Number of Splitter Vanes for bends


2540 2290 2030 1780 1520 1270 1020

SafidVent

Lindab Safe

No. 1 of 2

No. 1 of 1

760

No. 2 of 2

Lindab Transfer

760

Safid Double Wall

510

510

Inside Radius for Bend in mm

No. 1 of 3

No. 2 of 3

No. 3 of 3

SafidOval Double Wall

254 229 203 178 152 127 102

254 229 203 178 152 127 102

8 32
Safid Flexible

76

76

Notes Standards

51

Example: 508 235 108 51

51

Products & Accessories

Lindab Comfort

25

25

Number of Splitters
No. 1 of 76 mm i.e. No. 1 vane of a total of 3 vanes. No. 2 of 76 mm i.e. No. 2 vane of a total of 3 vanes.

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Outside Radiusin mm

SafidOval

SafidRectangular
Transverse Joints
General

Transverse Joints

Drive Slip & Hemmed "S" Slip

Reinforced "S" Slip & Standing S


18 Ga. H

Drive Slip 1

Hemmed "S" Slip 2

Reinforced "S" Slip 3

Standing S 4

Slide on Flange - SAF - 30

Companion Angles 8 33
Rivet H

Gasket

Flange - SAF - 30 5 * For details see page 7/31.

Gasket

Backup angle for Drive Slip


Applications
75 mm Drive Slip

Pressure Class
Backup Angle

Duct Height 458 - 915 458 - 559 407 - 508

Backup Angle Size 25x25x3mm 25x25x3mm 25x25x3mm

3" W.G. 4" W.G. Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Lindab Comfort

2" W.G.

Products & Accessories

Notes Standards

Companion Angles

Safid Flexible

SafidOval Double Wall

SafidOval

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

SafidRectangular
Safid Flange System
General

SAF - 30 Flange Joint System


Clamps as Required SACL - 30

Lindab Safe

SafidVent

30 mm

Lindab Transfer

35 mm Duct Wall Gasket Spot Welding

Safid Profile Flange SAF - 30

Safid Double Wall

SAF 30 - Slide on Flange

Dimensions
12 mm

SAF - 30 - Ga. 20 SAF - 30 - Ga. 22

SafidOval

30 mm

SafidOval Double Wall

35 mm

Corner Piece - SACP - 30

Dimensions
106 mm 26 mm

8 34
Safid Flexible

Dia 12 mm

Notes Standards

Clamp - SACL - 30

Dimensions
33 mm

Products & Accessories

19 mm

30 mm

Lindab Comfort

3 mm

Dia 8 mm x L 25 mm

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Table 1: 2" W.G. Pressure Class (Safid Rolled Formed Flange)


Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections Slide on flange 30x35xGa.20 (SAF-30 ) Slide on flange 30x35xGa.20 (SAF-30 ) Slide on flange 30x35xGa.20 (SAF-30 ) Slide on flange 30x35xGa.20 (SAF-30 ) Slide on flange 30x35xGa.20 (SAF-30 )

0 - 508

26

Double corner seam

Not required

509 - 1067

24

Double corner seam

Not required

1068 - 1219

22

Double corner seam

Not required

1220 - 1372

20

Double corner seam

Not required

1373 - 1524

18

Pittsburgh lock seam

Not required

1525 - 2134

18

Pittsburgh lock seam Pittsburgh lock seam

Not required

Companion angle 50x50x5mm Companion angle 50x50x5mm

2135 - 2438

18

Not required

2439 - 2743

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

8 35

2744 - 3048

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General

Table 2: 2" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections

SafidVent

0 - 254

26

Double corner seam

Not required

Hemmed "S slip Drive slip (24 Ga.) Reinforced "S slip with 25x25x16Ga. Drive slip (24 Ga.) 1" Standing S (22Ga.) Drive slip with 25x25x3mm angle Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30)

Lindab Safe

255 - 457

26

Double corner seam

Not required

Lindab Transfer

458 - 610

24

Double corner seam

Not required

Safid Double Wall

611 - 915

24

Double corner seam

Not required

916 - 1219

22

Double corner seam

Not required

SafidOval

1220 - 1372

20

Double corner seam

Not required

SafidOval Double Wall

1373 - 1524

18

Pittsburgh lock seam

Not required

8 36
Safid Flexible

1525 - 2134

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

2135 - 2438

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

2439 - 2743

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

Notes Standards

2744 - 3048

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

Lindab Comfort

Products & Accessories

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Table 2A: 2" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections

0 - 254

26

Double corner seam

Not required

Hemmed "S" slip Drive slip (24 Ga.) Reinforced "S" slip with 25x25x16Ga. Drive slip (24 Ga.) 1" Standing S (20Ga.) Drive slip with 25x25x3mm angle 1" Standing S (18Ga.) Drive slip with 25x25x3mm angle Slide on flange 30x35xGa.20 (SAF-30 ) Slide on flange 30x35xGa.20 (SAF-30 ) Slide on flange 30x35xGa.20 (SAF-30 )

255 - 457

26

Double corner seam

Not required

458 - 711

24

Double corner seam

Not required

712 - 915

24

Double corner seam

Not required

916 - 1219

22

Double corner seam

Not required

1220 - 1372

20

Double corner seam

Not required

1373 - 1524

18

Pittsburgh lock seam

Not required

1525 - 2134

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

8 37

2135 - 2438

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

2439 - 2743

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

2744 - 3048

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General

Table 2B: 2" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections

SafidVent

0 - 254

26

Double corner seam

Not required

Hemmed S slip Drive slip (24 Ga.) Reinforced S slip with 25x25x16Ga. Drive slip (24 Ga.) 1" Standing S (20Ga.) Drive slip with 25x25x3mm angle 1" Standing S (18Ga.) Drive slip with 25x25x3mm angle

Lindab Safe

255 - 457

26

Double corner seam

Not required

Lindab Transfer

458 - 711

24

Double corner seam

Not required

Safid Double Wall

712 - 915

24

Double corner seam

Not required

916 - 1219

22

Double corner seam

Not required

Companion angle 30x30x3mm

SafidOval

1220 - 1372

20

Double corner seam

Not required

Companion angle 40x40x3mm

SafidOval Double Wall

1373 - 1524

18

Pittsburgh lock seam

Not required

Companion angle 40x40x3mm

8 38
Safid Flexible

1525 - 2134

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

2135 - 2438

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

2439 - 2743

18

Pittsburgh lock seam Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c 50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm Companion angle 50x50x5mm

Notes Standards

2744 - 3048

18

Lindab Comfort

Products & Accessories

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Table 2C: 2" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections

0 - 254

26

Double corner seam

Not required

Hemmed S slip Drive slip (24 Ga.) Reinforced S slip with 25x25x16Ga. Drive slip (24 Ga.)

255 - 457

26

Double corner seam

Not required

458 - 610

24

Double corner seam

Not required

Companion angle 25x25x3mm

611 - 915

24

Double corner seam

Not required

Companion angle 25x25x3mm

916 - 1219

22

Double corner seam

Not required

Companion angle 30x30x3mm

1220 - 1372

20

Double corner seam

Not required

Companion angle 40x40x3mm

1373 - 1524

18

Pittsburgh lock seam

Not required

Companion angle 40x40x3mm

1525 - 2134

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

8 39

2135 - 2438

18

Pittsburgh lock seam

Not required

Companion angle 50x50x5mm

2439 - 2743

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

2744 - 3048

18

Pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General

Table 3: 3" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections

SafidVent

0 - 457

24

double corner seam

not required

1" Standing S (22Ga.) Drive slip (24Ga.) 1" Standing S (22Ga.) Drive slip with 25x25x3mm angle Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30)

Lindab Safe

458 - 559

24

double corner seam

not required

Lindab Transfer

560 - 762

24

double corner seam

not required

Safid Double Wall

763 - 915

22

double corner seam

not required

916 - 1067

22

double corner seam

not required

SafidOval

1068 - 1219

20

double corner seam

not required

SafidOval Double Wall

1220 - 1524

18

pittsburgh lock seam

not required

Companion angle 50x50x5mm

8 40
Safid Flexible

1525 - 2438

18

pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Companion angle 50x50x5mm Companion angle 50x50x5mm + tie rod

2439 - 3048

18

pittsburgh lock seam

50x50x5mm angle @ 600mm c-c

Lindab Comfort

Products & Accessories

Notes Standards

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Table 4: 4" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections

0 - 406

24

double corner seam

not required

1" Standing S (22Ga.) Drive slip (24Ga.) 1" Standing S (22Ga.) Drive slip with 25x25x3mm angle Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30)

407 - 508

24

double corner seam

not required

509 - 762

24

double corner seam

not required

763 - 915

22

double corner seam

not required

916 - 1067

20

double corner seam

not required

1068 - 1372

18

pittsburgh lock seam

not required

Companion angle 50x50x5mm

1373 - 2134

18

pittsburgh lock seam

50x50x5mm angle + tie rod @ 600mm c-c 50x50x5mm angle + tie rod @ 600mm c-c 50x50x5mm angle + tie rod @ 600mm c-c

Companion angle 50x50x5mm

2135 - 2438

18

pittsburgh lock seam

Companion angle 50x50x5mm Companion angle 50x50x5mm + tie rod

8 41

2493 - 3048

18

pittsburgh lock seam

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General

Table 5: 6" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30)

SafidVent

0 - 559

24

double corner seam

not required

Lindab Safe

560 - 660

22

double corner seam

not required

Lindab Transfer

661 - 762

22

double corner seam

not required

Safid Double Wall

763 - 915

20

double corner seam

not required

916 - 1219

18

pittsburgh lock seam

not required

Companion angle 50x50x5mm

SafidOval

1220 - 1524

18

pittsburgh lock seam

50x50x5mm angle + tie rod @ 600mm c-c 50x50x5mm angle + tie rod @ 600mm c-c 50x50x5mm angle + tie rod @ 600mm c-c 65x65x5mm angle + tie rod @ 600mm c-c

Companion angle 50x50x5mm

SafidOval Double Wall

1525 - 2134

18

pittsburgh lock seam

Companion angle 50x50x5mm Companion angle 50x50x5mm + tie rod Companion angle 50x50x5mm + tie rod

8 42
Safid Flexible

2135 - 2743

18

pittsburgh lock seam

2744 - 3048

18

pittsburgh lock seam

Lindab Comfort

Products & Accessories

Notes Standards

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Table 6: 10" W.G. Pressure Class (as per SMACNA 1995 2nd ed.)
Maximum Duct Dimension U.S. Gage Longitudinal Connections Intermediate Reinforcement Transverse Connections Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30) Slide on flange 30x35xGa.20 (SAF-30)

0 - 305

24

double corner seam

not required

306 - 406

22

double corner seam

not required

407 - 508

20

double corner seam

not required

509 - 559

20

double corner seam

not required

560 - 660

20

double corner seam

not required

661 - 711

18

pittsburgh lock seam

not required

Companion angle 40x40x3mm

712 - 915

18

pittsburgh lock seam

not required

Companion angle 50x50x5mm

916 - 1372

18

pittsburgh lock seam

50x50x5mm angle + tie rod @ 600mm c-c 50x50x5mm angle + tie rod @ 600mm c-c 50x50x5mm angle + tie rod @ 600mm c-c 65x65x6mm angle + tie rod @ 600mm c-c

Companion angle 50x50x5mm

8 43

1373 - 1524

18

pittsburgh lock seam

Companion angle 50x50x5mm Companion angle 50x50x5mm + tie rod Companion angle 50x50x6mm + tie rod

1525 - 1829

18

pittsburgh lock seam

1830 - 3048

16

pittsburgh lock seam

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General

Table 7: 500 Pa Pressure Class (as per DW/144)


Maximum Duct Dimension 0 - 400 401 - 600 601 - 1000 1001 - 1250 1251 - 1600 1601 - 2000 U.S. Gage 24 22 22 20 20 20 20 18 Longitudinal Connections Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Intermediate Reinforcement Not required Not required Not required Not required 30x30x4mm @ 600 c-c 40x40x4mm @ 600 c-c 50x50x5mm @ 600 c-c 50x50x5mm @ 600 c-c Transverse Connections Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 30x30x4mm Companion angle 40x40x4mm Companion angle 40x40x4mm Companion angle

Safid Double Wall

Lindab Transfer

Lindab Safe

SafidVent

2001 - 2500 2501 - 3000

SafidOval Double Wall

SafidOval

8 44
Safid Flexible

Table 8: 1000 Pa Pressure Class (as per DW/144)


Maximum Duct Dimension 0 - 400 401 - 1000 1001 - 1250 1251 - 1600 1601 - 2500 2501 - 3000 U.S. Gage 24 22 20 20 20 18 Longitudinal Connections Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Intermediate Reinforcement Not required Not required 30x30x4mm @ 600 c-c 40x40x4mm @ 600 c-c 50x50x5mm @ 600 c-c 60x60x5mm @ 600 c-c Transverse Connections Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 30x30x4mm Companion angle 40x40x4mm Companion angle 50x50x5mm Companion angle

Lindab Comfort

Products & Accessories

Notes Standards

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Ductwork Construction Schedule
General Lindab Comfort Products & Accessories Notes Standards Safid Flexible SafidOval Double Wall SafidOval Safid Double Wall Lindab Transfer Lindab Safe SafidVent

Table 9: 2000 Pa Pressure Class (as per DW/144)


Maximum Duct Dimension 0 - 400 401 - 600 601 - 800 801 - 1000 1001 - 1250 1251 - 1600 1601 - 2000 2001 - 2500 U.S. Gage 22 22 22 22 20 20 18 18 Longitudinal Connections Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Pittsburgh lock seam Intermediate Reinforcement Not required Not required Not required 30x30x4mm @ 600 c-c 40x40x4mm @ 600 c-c 50x50x5mm @ 600 c-c 50x50x5mm @ 600 c-c 60x60x5mm @ 600 c-c Transverse Connections Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 Slide on flange 30x35xGa.20 30x30x4mm Companion angle 40x40x4mm Companion angle 40x40x4mm Companion angle 50x50x5mm Companion angle

8 45

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

SafidRectangular
Specifications for duct and fittings
General

SafidVent

I GENERAL A. All Single wall, internally lined or double wall rectangular supply, return and exhaust ductwork shall be SafidRect as manufactured by Safid or approved equal.

B. Rectangular Ducts & Fittings: 1. Rectangular ducts & fittings shall be factory fabricated with factory applied sealant for a dependable quality line of products, and must be sufficiently airtight to ensure economical and quiet performance of the system. 2. All straight ducts shall be beaded, except if duct is internally lined, double wall, Ga. 18 ducts, and 4" w.g. duct pressure class or above. 3. All fittings are cross broken from dimensions 483 mm and above unless if duct is internally lined, double wall, Ga. 18 ducts, and 4" w.g. duct pressure class or above. 4. All fitting ends shall be calibrated to manufacturer's published dimensional tolerance standard. 5. All fittings shall be reinforced like sections of straight duct. One size change fittings, the greater fitting dimension determines the duct gage. 6. The throat radius of all 90 and 45 radius bends shall be equal to the width (R=W). Radius bend with splitter vanes is applicable if the throat radius is less than the width (R<W). 7. All fittings that are of either spot welded or button punched construction shall be internally sealed. Fittings that are continuously welded construction shall be without internal sealant.

Lindab Safe

II MATERIALS A. Unless otherwise noted, all duct and fittings shall be G-90 galvanized steel in accordance with ASTM A924 and A-653. (Formerly A527) B. Unless otherwise specified, reinforcement may be uncoated steel or galvanized steel. C. When specified on contract documents, stainless steel type 304 or type 316 in accordance with ASTM A-240 shall be provided.

Safid Double Wall

Lindab Transfer

SafidOval

III CONSTRUCTION A. Where no specific duct pressure class designations are provided, all duct and fittings shall be constructed as per SMACNAs Duct Construction Standards 500 pa. (+2 in W.G.) shown in the following table:

SafidOval Double Wall

Rectangular Duct & Fittings Maximum Duct Dimensions (mm)


0 - 457 458 - 915 916 - 1219 1220 - 1372 1373 - 1524

U.S. Gage
26 24 22 20 18 18

8 46
Safid Flexible

IV PERFORMANCE

1525 - 3048

A. Duct system performance shall meet SMACNAs Leakage class 6 requirements.

Lindab Comfort

Products & Accessories

Notes Standards

Longitudinal connections, intermediate reinforcement and transverse connections shall be in accordance with SMACNA standards 1995, latest edition, or as per Ductwork Construction Schedule on page 8/35.

Right to alterations reserved.


is a registered trade mark. copyright SAFID 2000 - All Rights Reserved

Вам также может понравиться