SilkWorm 3800 Fan Tray FRU Procedure

Copyright
2001 Brocade Communications Systems, Incorporated. ALL RIGHTS RESERVED. Brocade, SilkWorm, SilkWorm Express, Brocade Fabric OS, Brocade Web Tools, Brocade Zoning, Brocade QuickLoop, Brocade Fabric Watch, Brocade Fabric Access, and the Brocade logo are trademarks or registered trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners. NOTICE: THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY AND DOES NOT SET FORTH ANY WARRANTY, EXPRESS OR IMPLIED, CONCERNING ANY EQUIPMENT, EQUIPMENT FEATURE, OR SERVICE OFFERED OR TO BE OFFERED BY BROCADE. BROCADE RESERVES THE RIGHT TO MAKE CHANGES TO THIS DOCUMENT AT ANY TIME, WITHOUT NOTICE, AND ASSUMES NO RESPONSIBILITY FOR ITS USE. Export of technical data contained in this document may require an export license from the United States Government. Brocade Communications Systems, Incorporated 1745 Technology Drive San Jose, CA 95110
Publication Number #53-0001581-02

*20-1851000-35*

SilkWorm 3800 Fan Tray FRU Procedure

Brocade Communications Systems, Inc.

Replacing a Fan Tray


Use this procedure to replace a fan tray for the SilkWorm 3800. The switch can continue operating if the other fan tray is operating during the replacement and the replacement is completed within 8 minutes. Note: The fan trays are identical and fit into either fan tray slot. Each fan tray contains two fans. Once the fan trays are installed, the fans inside the trays are identified by the Fabric OS as fans #1, #2, #3, and #4. Fans #1 and #2 are in the fan tray that is on the left when viewing the switch from the front, and fans #3 and #4 are in the fan tray on the right.

Caution

Disassembling any part of the fan tray voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the fan tray.

Time required:
Less than 5 minutes.

Items required:

The SilkWorm 3800 The new fan tray, P/N 60-0001005

Procedure

Power Supply (2x)

Fan Tray containing fans #3 and 4 Fan Tray containing fans #1 and 2 Spring Latch (2x)

Figure 1 The SilkWorm 3800 with one fan tray installed and one uninstalled.

Publication Number 53-0001581-02

Page 2 of 3

SilkWorm 3800 Fan Tray FRU Procedure

Brocade Communications Systems, Inc.

Caution

If a fan tray is replaced while the switch is operating, the other fan tray must continue to operate during the replacement and the replacement fan tray must be installed and operating within 8 minutes, to prevent overheating of the switch. If the second fan tray is not operating, the switch should be turned off until both fan trays are replaced. Do not leave either of the fan tray slots empty longer than 8 minutes while the switch is operating, because the cooling system is pressurized.

Figure 2

Removing and replacing the fan tray with the correct orientation. This illustration is also provided in a label on the fan tray.

1.

Remove the fan tray from the chassis: a. b. Press the spring latch on the side of the fan tray towards the center of the fan tray. Pull the fan tray from the switch chassis.

2.

Install the new fan tray. a. Orient the new fan tray so that the spring latch is towards the center of the back panel and the spring latch lines up with the slot in the chassis.

Caution
b.

Do not force the installation. If the fan tray does not slide in easily, ensure it is properly oriented before continuing with the installation.

Slide the fan tray into the chassis until the spring latch snaps into the slot and the fan tray is firmly seated The fan tray begins operating as soon as it is seated.

Publication Number 53-0001581-02

Page 3 of 3