SUMMARY FAN DATA SHEET

Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:58 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF5-B2G Installation Manual Links: 671268 Required Duty: 168 l/s @ 100 Pa Actual Duty: 231 l/s @ 189 Pa Actual at Required Flow: 168 l/s @ 237 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 1,260 RPM 1 Phase 0.328 kW flc: 1.3 A sc: 5.5 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-7 - YAHAR & AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 43 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 52 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 73 68 63 60 56 55 52 50 Open Outlet 81 76 70 63 66 62 59 56 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

1,165 980 575 250 31 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
350

300

250

200

150 Static Pressure (Pa)

100

50

0 100 Volume Flow Rate (l/s)

200

300

400

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF5-B2G Installation Manual Links: 671268 Required Duty: 234 l/s @ 150 Pa Actual Duty: 250 l/s @ 171 Pa Actual at Required Flow: 234 l/s @ 186 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 1,260 RPM 1 Phase 0.328 kW flc: 1.3 A sc: 5.5 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-10 - YAHAR & AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 43 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 52 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 73 68 63 60 56 55 52 50 Open Outlet 81 76 70 63 66 62 59 56 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

1,165 980 575 250 31 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
350

300

250

200

150 Static Pressure (Pa)

100

50

0 100 Volume Flow Rate (l/s)

200

300

400

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF5-B2G Installation Manual Links: 671268 Required Duty: 244 l/s @ 150 Pa Actual Duty: 255 l/s @ 164 Pa Actual at Required Flow: 244 l/s @ 176 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 1,260 RPM 1 Phase 0.328 kW flc: 1.3 A sc: 5.5 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-12 - YAHAR & AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 43 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 52 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 73 68 63 60 56 55 52 50 Open Outlet 81 76 70 63 66 62 59 56 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

1,165 980 575 250 31 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
350

300

250

200

150 Static Pressure (Pa)

100

50

0 100 Volume Flow Rate (l/s)

200

300

400

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF7-B2G Installation Manual Links: 671268 Required Duty: 460 l/s @ 150 Pa Actual Duty: 542 l/s @ 209 Pa Actual at Required Flow: 460 l/s @ 250 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 1,260 RPM 1 Phase 0.915 kW flc: 4 A sc: 18 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-15 - YAHAR & AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 61 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 62 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 88 83 76 71 72 74 70 65 Open Outlet 87 82 78 73 76 73 71 62 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

1,165 980 575 400 57 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
450 400 350 300 250 200 150 100 50 0

Static Pressure (Pa)

0 200 Volume Flow Rate (l/s)

400

600

800

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF3-B2G Installation Manual Links: 671268 Required Duty: 50 l/s @ 100 Pa Actual Duty: 65 l/s @ 171 Pa Actual at Required Flow: 50 l/s @ 180 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 1,264 RPM 1 Phase 0.219 kW flc: 1.36 A sc: 4.6 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-16 - YAHAR & AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 41 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 46 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 81 76 60 59 51 52 50 46 Open Outlet 76 71 63 56 60 57 53 49 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

970 720 485 200 23 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
225 200 175 150 125 100 75 50 25 0

Static Pressure (Pa)

0 50 Volume Flow Rate (l/s)

100

150

200

250

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Belt Drive, Three Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF14-B2G Installation Manual Links: 671269 Required Duty: 1340 l/s @ 250 Pa Actual Duty: 1650 l/s @ 379 Pa Actual at Required Flow: 1340 l/s @ 455 Pa Motor Efficiency: 86 % Fan Efficiency: 29 % Fan Input Power: 2.199 kW Maximum Fan Input Power: 3.353 kW Motor Input Power: 2.54 kW Specific Fan Power: 1.539 W/(l/s) Nominal Fan Speed: 4 Pole 1,040 RPM Electrical Supply: 3 Phase Nominal Motor Rating: 4 kW Motor Current: flc: 10 A Motor Current: sc: 60 A Starting currents are nominal. 4 kW and above are for Star Delta, all others are for D.O.L. starting. Max. Operating Temp.: 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-22 (ALT-1) - YAHAR & AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers belt driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 63 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 74 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 89 84 82 80 79 77 75 70 Induct Outlet 96 91 83 90 88 85 84 78 Breakout 90 84 78 81 74 69 65 56 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

kg

1,430 1,635 796 630 175 The drawing is for dimensional purposes only. Dimensions in mm.

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671269 on our website.

Performance Curve
500 450 400 350 300 250 200 Static Pressure (Pa) 150 100 50 0

0 500 Volume Flow Rate (l/s)

1k

1500

2k

2500

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Belt Drive, Three Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF12-B2G Installation Manual Links: 671269 Required Duty: 1340 l/s @ 250 Pa Actual Duty: 1325 l/s @ 244 Pa Actual at Required Flow: 1340 l/s @ 235 Pa Motor Efficiency: 84 % Fan Efficiency: 21 % Fan Input Power: 1.673 kW Maximum Fan Input Power: 1.92 kW Motor Input Power: 1.984 kW Specific Fan Power: 1.498 W/(l/s) Nominal Fan Speed: 4 Pole 1,040 RPM Electrical Supply: 3 Phase Nominal Motor Rating: 2.2 kW Motor Current: flc: 5.4 A Motor Current: sc: 29 A Starting currents are nominal. 4 kW and above are for Star Delta, all others are for D.O.L. starting. Max. Operating Temp.: 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-22 (ALT-2) - AL HAYER

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers belt driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 50 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 59 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 80 75 70 71 65 60 62 55 Induct Outlet 85 80 79 80 76 69 69 64 Breakout 79 73 71 71 63 53 50 43 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

kg

1,233 1,233 701 500 134 The drawing is for dimensional purposes only. Dimensions in mm.

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671269 on our website.

Performance Curve
1000 900 800 700 600 500 400 Static Pressure (Pa) 300 200 100 0

0 400 Volume Flow Rate (l/s)

800

1200

1600

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF6-B2G Installation Manual Links: 671268 Required Duty: 288 l/s @ 150 Pa Actual Duty: 344 l/s @ 214 Pa Actual at Required Flow: 288 l/s @ 246 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 1,200 RPM 1 Phase 0.511 kW flc: 2.24 A sc: 7.9 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-5 - SWEIHAN

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 48 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 58 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 76 71 69 62 57 59 57 57 Open Outlet 80 75 70 70 73 68 63 62 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

1,165 980 575 400 57 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
400 350 300 250 200 150 Static Pressure (Pa) 100 50 0

0 100 200 Volume Flow Rate (l/s)

300

400

500

600

SUMMARY FAN DATA SHEET


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk UK Technical Enquiries Tel:029 2085 8200 Fax:029 2085 8300 International Enquiries Tel:+44 29 2085 8335 Fax:+44 29 2085 8278
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended. This data sheet produced on 13 Feb 2012 08:59 using software version 2.5.03 - 19 October 2011

Technical Data
NALTRF-B2G - Roof Mounted Ducted Inlet Twinfan, Direct Drive, Single Phase
Roof Mounted Ducted Inlet Twinfan Fan Code: NALTRF8-B2G Installation Manual Links: 671268 Required Duty: 674 l/s @ 150 Pa Actual Duty: 829 l/s @ 227 Pa Actual at Required Flow: 674 l/s @ 254 Pa Nominal Fan Speed: Electrical Supply: Nominal Motor Rating: Motor Current: Motor Current: Max. Operating Temp.: 960 RPM 1 Phase 1.406 kW flc: 6.3 A sc: 50 A 60C

Project Details
AMBULATORY HEALTH CARE CENTRES
Location: EXF-6 - SWEIHAN

Specification
External roof mounted twin fan unit manufactured from aluzinc. Outlet grilles are positioned on opposite sides of the fan casing to prevent wind pressures effecting fan performance. Fan assemblies incorporate forward curved centrifugal impellers directly driven by BS5000 motors fitted with airflow fail monitors. Fans are suitable for operation in ambient temperatures up to 60C. All units are suitable for internal and external use and may be installed up to a maximum angle of 5. (Care must be taken to ensure the back draught dampers operate correctly).

Fan Dimensions

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300. Inlet Noise (dBA): 61 dBA @ 3m (90% of Max Pa) Outlet Noise (dBA): 68 dBA @ 3m (90% of Max Pa) Sound Power Levels re 1 pWatts (Hz): Hz 63 125 250 500 1k 2k 4k 8k Induct Inlet 78 73 70 71 73 73 71 66 Open Outlet 91 86 82 81 80 78 77 74 Values shown are for inlet Lw and outlet Lw sound power levels for: Installation Type C: ducted inlet, free outlet. Ratings include the effects of duct end correction.

kg

Wiring Information
For complete wiring details please refer to the Installation & Maintenance Manual reference 671268 on our website.

1,495 1,125 710 500 162 The drawing is for dimensional purposes only. Dimensions in mm.

Performance Curve
450 400 350 300 250 200 150 100 50 0

Static Pressure (Pa)

0 400 Volume Flow Rate (l/s)

800

1200

1600