Вы находитесь на странице: 1из 77

DCR-HC47E/HC48/HC48E

RMT-831
Ver. 1.0 2006.12
Revision History

SECTION 6 ADJUSTMENTS

ADJ

Link
Before starting adjustments
Adjusting items when replacing main parts and boards List of service tools

VIDEO SECTION ADJUSTMENTS


PREPARATIONS BEFORE ADJUSTMENTS SYSTEM CONTROL SYSTEM ADJUSTMENTS SERVO AND RF SYSTEM ADJUSTMENTS

CAMERA SECTION ADJUSTMENTS


PREPARATIONS BEFORE ADJUSTMENTS INITIALIZATION OF EVR DATA CAMERA SYSTEM ADJUSTMENTS ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS

VIDEO SYSTEM ADJUSTMENTS AUDIO SYSTEM ADJUSTMENTS

SERVICE MODE
ADJUSTMENT REMOTE COMMANDER (RM-95) ADJUSTMENT REMOTE COMMANDER (NEW LANC JIG) DATA PROCESS

MECHANISM SECTION ADJUSTMENTS


HOW TO ENTER RECORD MODE WITHOUT CASSETTE HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE TAPE PATH ADJUSTMENT

SERVICE MODE

Precaution on Replacing the VC-472 Board

DCR-HC47E/HC48/HC48E_ADJ
9-852-170-51

Sony EMCS Co.

2006L0500-1 2006.12 Published by Kohda TEC

TABLE OF CONTENTS
Section Title Page

6.

ADJUSTMENTS

1. Before Starting Adjustments 6-1 1-1. Adjusting Items when Replacing Main Parts and Boards 6-3 1-2. List of Service Tools 6-5 6-1. Camera Section Adjustments 6-6 1-1. Preparations before Adjustments (CAMERA Section) 6-6 1-2. Initialization of EVR Data 6-9 1-3. Camera System Adjustments 6-21 1-4. Electronic Viewfinder System Adjustments 6-39 1-5. LCD System Adjustments 6-41 6-2. Mechanism Section Adjustments 6-44 2-1. How To Enter Record Mode Without Cassette 6-44 2-2. How To Enter Playback Mode Without Cassette 6-44 2-3. Tape Path Adjustment 6-44 6-3. Video Section Adjustments 6-45 3-1. Preparations Before Adjustments 6-45 3-2. System Control System Adjustments 6-47 3-3. Servo and RF System Adjustments 6-50 3-4. Video System Adjustments 6-53 3-5. Audio System Adjustments 6-59 6-4. Service Mode 6-61 4-1. Adjustment Remote Commander (RM-95) 6-61 4-2. Adjustment Remote Commander (New Lanc Jig ) 6-62 4-3. Data Process 6-63 4-4. Service Mode 6-64 * The camera color reproduction frame is shown on page 6-74.

DCR-HC47E/HC48/HC48E_ADJ 2

SECTION 6 ADJUSTMENTS

1.

Before starting adjustments EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data to a personal computer.

Download the saved data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board)

(New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data. Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-3 for the items to be checked)

DCR-HC47E/HC48/HC48E_ADJ 6-1

Precaution on Replacing the VC-472 Board


Perform Exif Model Data Check mentioned below, and also the adjustment items necessary after VC Board replacement.

Exif Model Data Check


When you replace to the repairing board, the written data of repairing board also might be changed to original setting. When the data has changed because of board replaceing etc, check the data setting (Exif Model Data) is right. If not, rewrite to the right value.

Exif Model Data Page C C C Address D2 D3 D4 DCR-HC47E 34 37 45 Data DCR-HC48 34 38 00 DCR-HC48E 34 38 45

Writing Method: 1) Select page: 0, address: 01 and set data: 01. 2) Select page: C, address: D2 to D4, and set the Exif Model Data. Note: To write in the non-volatile memory (EEPROM), press the PAUSE (Write) button each time to set the data. 3) Select page: 0, address: 01, and set data: 00.

DCR-HC47E/HC48/HC48E_ADJ 6-2

1-1.

Adjusting items when replacing main parts and boards

Adjusting items when replacing main parts When replacing main parts, adjust the items indicated by z in the following table. Note 1: When replacing the drum assy or the mechanism deck, reset the data of page: 7, address: A8 to AB to 00. (Refer to Record of Use check of 6-4. SERVICE MODE)
Block replacement Replaced part Mounted part replacement

Adjustment Section

Adjustment

Initialization of A, B, D, 1A, 1B page data Initialization of EVR data Camera Initialization of 8, C, 18, 1C page data Initialization of 63 to 6F page data 33MHz/27MHz origin oscillation check. HALL adj. Flange back adj. F No. & ND light quality standard data input MAX GAIN adj. Mechanical shutter adj. Color reproduction adj. Auto white balance standard data input LV standard data input Auto white balance adj. Steadyshot check EVF automatic adj. White balance adj. LCD automatic adj. V-COM adj. Transmissive mode white balance adj. Touch panel adj. Tape path adj. Node uniqe ID No. input USB Serial number data setting CAP FG duty adj. Switching position adj. Error rate check IC4701 LINE OUT Y level adj. IC4701 LINE OUT chroma level adj. S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. IC4701 automatic adj.
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

EVF LCD

Mechanism System control Servo, RF

Video

Table 6-1-1 (1)

DCR-HC47E/HC48/HC48E_ADJ 6-3

Lens device LCD block LCD901 EVF block LCD902 Mechanism deck (Note 1) Mechanism deck M901 Mechanism deck MD block CD-672 board IC7002 CD-672 board SE7002, 7001 LB-132 board D301 PD-312 board D6303 - 6305 PD-312 board Q6301, 6302 VC-472 board IC3201, X3201 VC-472 board IC3901 VC-472 board IC4001 VC-472 board IC4201 VC-472 board IC4301 VC-472 board IC4401 VC-472 board IC4701 VC-472 board IC5101 VC-472 board IC7001
z z z z z z z z z z z z z z z z z z z z z z z z z z z z

(CCD imager) (PITCH, YAW sensor) (Back light (EVF)) (Back light (LCD)) (Touch panel I/F) (A/D converter, Timing generator) (Camera signal process) (Video/Audio DSP) (DV signal process) (REC/PB AMP) (Video, Audio I/O) (Aspect ratio converter) (DS/HI control) (LCD/EVF drive)

(Drum assembly) (Note 1)

(LCD panel, Touch panel) (LCD panel)

Adjusting items when replacing a board or EEPROM When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Replaced part

Note 2: IC5202 (Flash memory) on the VC-472 board cannot be replaced. Note 3: When replacing the VC-472 board, perform Exif Model Data check after replacement.

Adjustment Section

Adjustment

(COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) (Note 3) (EEP ROM) CD-672 board LB-132 board PD-312 board VC-472 board VC-472 board IC5302
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

Initialization of A, B, D, 1A, 1B page data Initialization of EVR data Camera Initialization of 8, C, 18, 1C page data Initialization of 63 to 6F page data 33MHz/27MHz origin oscillation check. HALL adj. Flange back adj. F No. & ND light quality standard data input MAX GAIN adj. Mechanical shutter adj. Color reproduction adj. Auto white balance standard data input LV standard data input Auto white balance adj. Steadyshot check EVF automatic adj. White balance adj. LCD automatic adj. V-COM adj. Transmissive mode white balance adj. Touch panel adj. Tape path adj. Node uniqe ID No. input USB Serial number data setting CAP FG duty adj. Switching position adj. Error rate check IC4701 LINE OUT Y level adj. IC4701 LINE OUT chroma level adj. S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. IC4701 automatic adj.

EVF LCD

Mechanism System control Servo, RF

Video

Table 6-1-1 (2)

DCR-HC47E/HC48/HC48E_ADJ 6-4

Supporting

RadarW

1-2.

List of service tools


Color monitor Frequency counter Audio attenuator Vectorscope Audio level meter Audio distortion meter

Oscilloscope Digital voltmeter Audio generator

J-1 Adjustment remote commander (RM-95) J-6082-053-B

J-2 Adjustment remote commander (NEW LANC JIG) J-6082-565-A

J-3 LANC cable J-6082-442-A

J-4 Pattern box PTB-450 J-6082-200-A or Small pattern box PTB-1450 J-6082-557-A J-7

J-5 Color bar chart For PTB-450: J-6020-250-A For PTB-1450: J-6082-559-A J-8 Flange back adjustment jig J-6082-563-A

J-6 Clear chart For PTB-450: J-6080-621-A For PTB-1450: J-6082-560-A J-9

Minipattern box J-6082-353-B

Siemens star chart J-6080-875-A

J-10 Filter for color temperature correction (C14) J-6080-058-A

J-11 ND filter 1.0 J-6080-808-A ND filter 0.4 J-6080-806-A ND filter 0.1 J-6080-807-A J-14 Tracking standard (XH2-1) 8-967-997-01 SW/OL standard (XH2-3) 8-967-997-11

J-12

Camera table J-6082-384-A

J-13

J-15

Audio operation check for NTSC (XH5-3) 8-967-997-51 for PAL (XH5-3P) 8-967-997-55

J-16

System operation check for NTSC (XH5-5) 8-967-997-61 for PAL (XH5-5P) 8-967-997-66

J-17
A

J-18 A: CPC-15 J-6082-564-A B: I/F unit for LANC control J-6082-521-A AC power adaptor (AC-L200/L200B) 1-479-285-21

J-19 Multi cable for service J-6082-535-A

Fig. 6-1-1

DCR-HC47E/HC48/HC48E_ADJ 6-5

6-1. CAMERA SECTION ADJUSTMENTS


1-1.
1-1-1.

PREPARATIONS BEFORE ADJUSTMENTS (CAMERA SECTION)


Preparations
Pattern box L L = 1 m (PTB-450) L = 40 cm (PTB-1450) Front of the lens Camera

Note: Before perform the adjustment, check that the data of page: 0, address: 10 is 00. If not, select page: 0, address: 10, and set data 00. 1) Connect the equipment for adjustments according to Fig. 6-13.

Fig. 6-1-2

A/V OUT jack

A/V OUT

AC adaptor

AC IN

Multi cable for service (J-6082-535-A)


To DC IN jack

Adjustment remote commander (NEW LANC JIG)

Camera system Adjustment Vectorscope Terminated 75 Color monitor Video

Audio L Audio R (RM-95)

Video system Adjustment Osilloscope Terminated 75

S-Video or Video

Fig. 6-1-3

DCR-HC47E/HC48/HC48E_ADJ 6-6

1-1-2. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette. 1. 2. 3. 4. 5. 6. 7. POWER switch (SS21200 block) .............. CAMERA-TAPE NIGHTSHOT PLUS switch (Lens block) ..................... OFF WIDE SELECT (Panel block) .......................................... 4:3 BACK LIGHT (CF102 board) ....................................... OFF SCENE SELECT (MENU setting) ............................. AUTO EXPOSURE (MENU setting) ..................................... AUTO WHITE BAL. (MENU setting) ................................... AUTO 8. 9. 10. 11. 12. 13. 14. FOCUS (MENU setting) ...................................... MANUAL COLOR SLOW S (MENU setting) ................................ OFF DIGITAL ZOOM (MENU setting) ................................ OFF STEADY SHOT (MENU setting) .................................. OFF D EFFECT (MENU setting) .......................................... OFF PICT. EFFECT (MENU setting) .................................... OFF DEMO MODE (MENU setting) .................................... OFF

2. Order of Adjustments Basically carry out adjustments in the order given. Color bar chart (Color reproduction adjustment frame)
Yellow Cyan Green White Magenta Red
H Electronic beam scanning frame

C=D

Blue

Yellow Cyan Green White Magenta Red Blue

CRT picture frame

V A B A=B B A Enlargement

Fig. b (monitor TV picture)

Fig. a (VIDEO terminal of A/V OUT jack output waveform)

Difference in level

Adjust the camera zoom and direction to obtain the output waveform shown in Fig. a and the monitor TV display shown in Fig. b.

Fig. 6-1-4

3. Subjects 1) Color bar chart (Color reproduction adjustment frame) When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-4. (Color reproduction adjustment frame) 2) Clear chart (AWB adjustment frame) Shoot the color bar chart. Then adjust the zoom to TELE side from WIDE side, and stop it when the black frame of the chart disappears. Remove the color bar chart from pattern box and insert a clear chart in its place. 3) Chart for flange back adjustment Join together a piece of white A0 size paper (1189mm 841 mm) and a piece of black paper to make the chart shown in Fig. 6-1-5. Note: Use a non-reflecting and non-glazing vellum paper. The size must be A0 or larger and the joint between the white and black paper must not have any undulations.

White 841 mm Black

1189 mm

Fig. 6-1-5

DCR-HC47E/HC48/HC48E_ADJ 6-7

4. Preparing the Flash Adjustment Box A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) 400 mm woody board B (2) 370 mm woody board C (1) 700 mm

513 mm

513 mm

700 mm

730 mm

700 mm

Fig. 6-1-6

2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-7)
woody board A

woody board B

woody board A

woody board B woody board C

Fig. 6-1-7

DCR-HC47E/HC48/HC48E_ADJ 6-8

1-2.

INITIALIZATION OF EVR DATA

Initializing method: Order Page Address Data 1 2 3 0 0 7 01 10 04 01 00 Set the following data 30: NTSC model 31: PAL model Set the following data 20: Initializing A page 21: Initializing B page 22: Initializing D page 23: Initializing 1A page 24: Initializing 1B page 25: Initializing A and 1A page 26: Initializing B and 1B page 28: Initializing A, B, D, 1A and 1B page 01 Press PAUSE (Write) button. Check the data changes to 01. Perform Modification of A, B, D, 1A, 1B Page Data Procedure

Note 1: Pages used for the EVR consists of 22 pages. There are 8, A to D, 18, 1A to 1C, 63 to 6F pages. Note 2: When reading or writing the 18, 1A, 1B or 1C page data, select page: 0, address: 10, and set data: 01, then select 8, A, B or C page. The 18, 1A, 1B or 1C page can be chosen by this data setting. After reading or writing, reset the data or page: 0, address: 10 to 00. Note 3: When reading or writing the 63 to 6F page data, select page: 0, address: 10, and set data: 06, then select 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, or F page. The 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E, or 6F page can be chosen by this data setting. After reading or writing, reste the data of page: 0, address: 10 to 00. 1-2-1. Initialization of A, B, D, 1A, 1B Page Data Note: Check that the data of page: 0, address: 10 is 00. 1. Initializing of A, B, D, 1A, 1B Page Data Note 1: If the A, B, D, 1A, 1B page data has been initialized, the following adjustments need to be performed again. 1) Modification of A, B, D, 1A, 1B page data 2) Touch panel adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address A 10 to FF B 00 to FF D 10 to 7F 1A 00 to FF 1B 00 to FF

01

5 6 7

7 7

00 02

Note 2: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E

DCR-HC47E/HC48/HC48E_ADJ 6-9

2. Modification of A, B, D, 1A, 1B Page Data If the A, B, D, 1A, 1B page data has been initialized, change the data of the Fixed data-2 address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages A, B, D, set data: 00 to page: 0, address: 10, and then select pages A, B, D. 3) If modification of data on pages 1A, 1B, set data: 01 to page: 0, address: 10, and then select pages A, B. After the modification of data finished, return the data on page: 0, address: 10 to 00. 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note 1: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Processing after Completing Modification A, B, D, 1A, 1B page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE (Write) button. Procedure

3. A Page table Note 1: Check that the data of page: 0, address: 10 is00. Note 2: Fixed data-1: Initialized data. (Refer to1. Initializing of A, B, D, 1A, 1B Page Data) Fixed data-2: Modified data. (Refer to2. Modification of A, B, D, 1A, 1B Page Data) Address 10 11 to 17 18 19 1A 1B to 2E 2F 30 31 32 33 to 5F 60 61 62 63 64 to 8F 90 91 92 93 94 to EF F0 F1 F2 F3 to FF Fixed data-1 (Initialized data) Fixed data-2 F0 0F E6 10 F3 0B DB 22 Fixed data-1 (Initialized data) Touch panel adj. Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL 00 00 Test mode Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark

Note 2: If following symptoms occur after completing of the Modification A, B, D, 1A, 1B page data, check that the data of the Fixed data-2 address of A, B, D, 1A, 1B page are same as those of same model of same destination. 1) The power is shut off so that unit cannot operate.

DCR-HC47E/HC48/HC48E_ADJ 6-10

4. B Page table Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of A, B, D, 1A, 1B Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of A, B, D, 1A, 1B Page Data) Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

6. 1A Page table Note 1: If reading/writing data on pages 1A, set data: 01 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 1A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of A, B, D, 1A, 1B Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of A, B, D, 1A, 1B Page Data) Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

5. D Page table Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of A, B, D, 1A, 1B Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of A, B, D, 1A, 1B Page Data) Address 10 to 15 16 17 to 29 2A 2B 2C to 37 38 39 3A 3B 3C to 57 58 59 to 7F Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

7. 1B Page table Note 1: If reading/writing data on pages 1B, set data: 01 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 1B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of A, B, D, 1A, 1B Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of A, B, D, 1A, 1B Page Data) Address 00 to FA FB FC FD FE, FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

DCR-HC47E/HC48/HC48E_ADJ 6-11

1-2-2.

Initialization of 8, C, 18, 1C Page Data

1. Initializing of 8, C, 18, 1C Page Data Note 1: If Initialization of Pages 8, C, 18, 1C is executed, all data on pages 8, C, 18, 1C are initialized. (Only an individual page cannot be initialized) Note 2: If the 8, C, 18, 1C page data has been initialized, the following adjustments need to be performed again. 1) Modification of 8, C, 18, 1C page data 2) Electronic viewfinder system adjustments 3) LCD system adjustments 4) Node unique ID No. input 5) Servo, RF system adjustments 6) Video system adjustments Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 3 4 5 6 0 0 3 3 3 01 10 81 80 80 0C 01 00 Check that the data is 00 Press PAUSE (Write) button. Check the data changes to 1C. Perform Modification of 8, C, 18, 1C Page Data Procedure 8 00 to FF C 10 to FF 18 00 to FF 1C 00 to FF

2. Modification of 8, C, 18, 1C Page Data If the 8, C, 18, 1C page data has been initialized, change the data of the Fixed data-2 address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages 8, C, set data: 00 to page: 0, address: 10, and then select pages 8, C. 3) If modification of data on pages 18, 1C, set data: 01 to page: 0, address: 10, and then select pages 8, C. After the modification of data finished, return the data on page: 0, address: 10 to 00. 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) If all areas were initialized, check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 8, C, 18, 1C page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE (Write) button. Procedure

DCR-HC47E/HC48/HC48E_ADJ 6-12

3. 8 Page table Note 1: Check that the data of page: 0, address: 10 is00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 8, C, 18, 1C Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 8, C, 18, 1C Page Data) Address 00 to 29 2A 2B to 79 7A 7B to 88 89 8A to BE BF C0 to C3 C4 C5 C6 C7 C8 C9 CA CB CC CD to D6 D7 D8 to E2 E3 E4 E5, E6 E7 E8 to F9 FA FB FC to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

4. C Page table Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 8, C, 18, 1C Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 8, C, 18, 1C Page Data) Address 10 11 12 13 14, 15 16 17 to 24 25 26 27 28 to 3B 3C 3D 3E 3F 40 41 to 44 45 46 47 48 to 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A, 5B 5C 5D 5E to 65 66 67 68 to 6A 7B 82 5B 7B 82 5B 84 8E 4C 8E 84 4C LCD automatic adj. (VCO adj.) V-COM adj. (LCD) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Transmissive mode white balance adj. (LCD) LCD automatic adj. (Contrast adj.) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 85 7A 4D 85 7A 4D 84 8E 8E 84 EVF automatic adj. (VCO adj.) Fixed data-1 (Initialized data) White balance adj. (EVF) EVF automatic adj. (Contrast adj.) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 5C 72 51 5B 73 54 20 20 Initial value NTSC PAL EE 00 00 00 EE 00 00 00 Fixed data-1 (Initialized data) CAP FG duty adj. Fixed data-1 (Initialized data) S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. Fixed data-1 (Initialized data) Switching position adj. Remark

DCR-HC47E/HC48/HC48E_ADJ 6-13

C Page table Address 6B 6C to 74 75 76 to 78 79 7A 7B 7C 7D to 7F 80 81 82 83 84 85 86 87 88 89 8A 8B to 90 91 92 93 94 95 96 97, 98 99 9A to A0 A1 A2 A3 A4 to A8 A9 AA AB AC AD to B1 B2 B3 B4 B5 to CB CC CD CE CF Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 18 18 18 18 18 18 Fixed data-1 (Initialized data) IC4701 Automatic adj. 80 80 Fixed data-1 (Initialized data) IC4701 Automatic adj. Fixed data-1 (Initialized data) Fixed data-2 99 C4 8B 00 00 00 00 12 52 38 21 90 CC 90 00 00 00 00 12 52 38 21 Fixed data-1 (Initialized data) IC4701 Automatic adj. Fixed data-1 (Initialized data) IC4701 LINE OUT Y level adj. IC4701 LINE OUT chroma level adj. Fixed data-2 Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Address D0 D1 D2 D3 D4 D5 to DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 to F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Emergency memory (Mechanism section) 08 00 46 01 02 00 00 00 08 00 46 01 02 00 00 00 Fixed data-1 (Initialized data) Node unique ID No. Input Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Initial value NTSC PAL Remark

DCR-HC47E/HC48/HC48E_ADJ 6-14

5. 18 Page table Note 1: If reading/writing data on pages 18, set data: 01 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 18 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 8, C, 18, 1C Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 8, C, 18, 1C Page Data) Address 00 to D7 D8 D9 to DC DD DE DF E0 E1 to E3 E4 E5 to F1 F2 F3 to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

6. 1C Page table Note 1: If reading/writing data on pages 1C, set data: 01 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 1C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 8, C, 18, 1C Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 8, C, 18, 1C Page Data) Address 00 to B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 to EF F0 F1 to FF 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Error rate check Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

DCR-HC47E/HC48/HC48E_ADJ 6-15

1-2-3.

Initialization of 63 to 6F Page Data

1. Initializing of 63 to 6F Page Data Note 1: If Initialization of Pages 63 to 6F is executed, all data on pages 63 to 6F are initialized. (Only an individual page cannot be initialized) Note 2: If the 63 to 6F page data has been initialized, the following adjustments need to be performed again. 1) Modification of 63 to 6F page data 2) Camera system adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data Procedure 1 2 3 0 0 6 01 10 01 01 00 Set the following data, and press PAUSE (Write) button. 2D: NTSC model 2F: PAL model 01 Press PAUSE (Write) button. Check the data changes to 01. 00 Press PAUSE (Write) button. Perform Modification of 63 to 6F Page Data 63 00 to 4F 64 00 to 8F 65 00 to 2F 66 00 to FF 67 00 to 6F 68 00 to AF 69 00 to 4F 6A 00 to AF 6B 00 to 5F 6C 00 to 4F 6D 00 to FF 6E 00 to 1F 6F 10 to FF

2. Modification of 63 to 6F Page Data If the 63 to 6F page data has been initialized, change the data of the Fixed data-2 address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages 63 to 6F, set data: 06 to page: 0, address: 10, and then select pages 3 to F. After the modification of data finished, return the data on page: 0, address: 10 to 00. 3) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 4) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 5) Check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 63 to 6F page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE (Write) button. Procedure

3. 63 Page table Note 1: If reading/writing data on pages 63, set data: 06 to page: 0, address: 10, and then select pages: 3. By this data setting, the pages 63 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 09 0A 0B 0C to 4F Initial value NTSC PAL Remark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

4 5 6 7

6 6 6

03 02 01

Note 3: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E

DCR-HC47E/HC48/HC48E_ADJ 6-16

4. 64 Page table Note 1: If reading/writing data on pages 64, set data: 06 to page: 0, address: 10, and then select pages: 4. By this data setting, the pages 64 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 7C 7D 7E 7F 80 81 82 83 to 8F Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

7. 67 Page table Note 1: If reading/writing data on pages 67, set data: 06 to page: 0, address: 10, and then select pages: 7. By this data setting, the pages 67 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 13 14 15 16 to 6F Initial value NTSC PAL Remark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

5. 65 Page table Note 1: If reading/writing data on pages 65, set data: 06 to page: 0, address: 10, and then select pages: 5. By this data setting, the pages 65 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 2F Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

8. 68 Page table Note 1: If reading/writing data on pages 68, set data: 06 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 68 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 07 08 09 to 74 75 76 77 78 to 91 92 93 94 95 96 to AF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

6. 66 Page table Note 1: If reading/writing data on pages 66, set data: 06 to page: 0, address: 10, and then select pages: 6. By this data setting, the pages 66 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 69 6A 6B 6C to C1 C2 C3 C4 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

DCR-HC47E/HC48/HC48E_ADJ 6-17

9. 69 Page table Note 1: If reading/writing data on pages 69, set data: 06 to page: 0, address: 10, and then select pages: 9. By this data setting, the pages 69 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 09 0A 0B 0C to 45 46 47, 48 49 4A to 4F Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

12. 6C Page table Note 1: If reading/writing data on pages 6C, set data: 06 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 6C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 38 39 3A to 4F Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

10. 6A Page table Note 1: If reading/writing data on pages 6A, set data: 06 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 6A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to AF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

13. 6D Page table Note 1: If reading/writing data on pages 6D, set data: 06 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 6D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 58 59 5A to 5E 5F 60 to 63 64 65 to 82 83 84 to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark

Fixed data-1 (Initialized data)

11. 6B Page table Note 1: If reading/writing data on pages 6B, set data: 06 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 6B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 5F Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

14. 6E Page table Note 1: If reading/writing data on pages 6E, set data: 06 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 00 to 1F Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

DCR-HC47E/HC48/HC48E_ADJ 6-18

15. 6F Page table Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Fixed data-1: Initialized data. (Refer to 1. Initializing of 63 to 6F Page Data) Fixed data-2: Modified data. (Refer to 2. Modification of 63 to 6F Page Data) Address 10 to 12 13 14 15, 16 17 18 19 1A, 1B 1C 1D 1E 1F 20 21 22 23 24 to 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A to 3F 40 41 42, 43 44 45 46 47 2B 58 56 A0 2B 58 56 A0 AWB adj. F9 EA FE E1 2C 2E 45 48 1E BE 06 C8 15 AA 0A 4A 1E BE 06 C8 15 AA 0A 4A Fixed data-1 (Initialized data) Color reproduction adj. Fixed data-1 (Initialized data) Color reproduction adj. Fixed data-1 (Initialized data) Color reproduction adj. Fixed data-1 (Initialized data) AWB adj. AWB standard data input 35 00 7F 35 00 70 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Fixed data-1 (Initialized data) LV standard data input MAX GAIN adj. Fixed data-1 (Initialized data) F No. & ND light quality standard data input 19 17 89 19 17 89 Fixed data-1 (Initialized data) HALL adj. 28 70 28 70 Initial value NTSC PAL Remark Fixed data-1 (Initialized data) HALL adj. Fixed data-1 (Initialized data)

Address 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 to 6C 6D 6E 6F to 71 72 73 74, 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B 8C to E7 E8

Initial value NTSC PAL 46 CA 53 89 0F 92 00 00 00 00 6C 19 00 35 00 00 00 00 00 46 CA 53 89 0F 92 00 00 00 00 6C 19 00 35 00 00 00

Remark

Flange back adj.

Fixed data-1 (Initialized data) 00 00 Flange back adj. Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) 5C 00 47 00 3E 00 38 00 28 00 62 7A 81 7C 6A 1E 80 80 80 80 80 80 20 4D 00 3C 00 34 00 2F 00 20 00 60 75 7B 76 63 1E 80 80 80 80 80 80 Fixed data-1 (Initialized data) 20 AWB standard data input Mechanical shutter adj.

DCR-HC47E/HC48/HC48E_ADJ 6-19

6F Page table Address E9 EA EB EC to F3 F4 F5 F6 F7 F8 to FF 16 C1 09 95 16 C1 09 95 Fixed data-1 (Initialized data) AWB adj. Initial value NTSC PAL B8 06 4E B8 06 4E Fixed data-1 (Initialized data) AWB standard data input Remark

DCR-HC47E/HC48/HC48E_ADJ 6-20

1-3.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments, check that the specified values of VIDEO SYSTEM ADJUSTMENTS are satisfied. (Except 33MHz/27MHz Origin Oscillation Check) Check that the data of page: 0, address: 10 is 00. If not, select page: 0, address: 10, and set the data 00. 1. 33MHz/27MHz Origin Oscillation Check (VC-472 board) (33MHz: NTSC/27MHz: PAL) Check the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Measurement Point Measuring Instrument Specified value Not required R3223 (line of CHCK) on VC-472 board Frequency counter f = 33000000 660 Hz (NTSC) f = 27000000 540 Hz (PAL)

2. HALL Adjustment RadarW For detecting the position of lens iris and ND filter, adjust the hall AMP gain and offset. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 6F 13, 14, 17 to 19 Data fo page: 6, address: 0C is 00 Not required Adjusting remote commander

Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Switch setting 1) POWER ............................................. CAMERA-TAPE mode Adjusting method: Order Page Address Data 1 2 3 4 0 6 6 6 6 01 02 01 02 0C 6D 01 Check the data is 00. (Note 2) Press PAUSE (Write) button. (Note 3) Check the data changes to 01. Check the data is 00. Procedure

Note: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) POWER ............................................. CAMERA-TAPE mode Checking method: 1) Check that the frequency (f) satisfies the specified value.

VC-472 board (SIDE A)


IC3201

Note 2: If not, select page: 6, address: 01, set data: 00, and press the PAUSE (Write) button. Note 3: The adjustment data will be automatically input to page: 6F, address: 13, 14, 17 to 19. Processing after Completing Adjustment: Order Page Address Data 1 2 6 0 01 01 00 00 Procedure Press PAUSE (Write) button.

R3223

Fig. 6-1-8

DCR-HC47E/HC48/HC48E_ADJ 6-21

Flange Back Adjustment RadarW (Using the minipattern box or flange back adjustment jig) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 3. Subject Siemens star chart with ND filter for minipattern box (Note 1) or flange back adjustment jig Adjusting remote commander 6F 48 to 58, 6D and 6E Data of pege: 6, address: 0C is 00

Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Note 1: Note 2: Note 3: Note 4:

Preparation (Using the minipattern box) 1) The minipattern box is installed as shown in the following figure. Note 7: The attachment lenses are not used. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera

Dark Siemens star chart. Perform HALL Adjustment before this adjustment. Perform the adjustment with the lens in horizontal state. If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 5: Dont touch the zoom lever during adjustment. Note 6: After adjustment, if the focusing to a subject located at infinity failed, increase the illuminance of the chart and perform readjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) COLOR SLOW S (Menu setting) ................................... OFF

Regulated power supply Output voltage : Specified voltage 0.01 Vdc Output current : more than 3.5 A

Red (+) Black () Yellow (SENS +) White (SENS ) Black (GND) Need not connected

Fig. 6-1-9
Preparation (Using the flange back adjustment jig) (Luminance: 950 to 1050 lux) 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camera is less than 3 cm. 2) Make the height of flange back adjustment jig and the camera equal. 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.
Flange back adjustment jig Below 3 cm

Camera

Fig. 6-1-10

DCR-HC47E/HC48/HC48E_ADJ 6-22

Adjusting method: Order Page Address Data 1 2 3 4 5 6 0 6 6 6 6 6 01 02 01 01 02 0C 13 27 01 Check the data is 00. (Note 8) Press PAUSE (Write) button. Press PAUSE (Write) button. (Note 9) Check the data changes to 01. Check the data is 00. Procedure

Note 8: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 9: The adjustment data will be automatically input to page: 6F, address: 48 to 58, 6D and 6E. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 6 6 6 6 6 0 01 01 02 01 01 00 00 Perform Flange Back Check. 00 25 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data change to 01. Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-23

4.

Flange Back Adjustment (Using the flange back adjustment chart and subject more than 500 m away) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 4-1. Flange Back Adjustment (1) RadarW Subject Flange back adjustment chart (2.0 m from the front of lens) (Luminance: 950 to 1050 lux) Adjusting remote commander 6F 48 to 58, 6D and 6E Data of pege: 6, address: 0C is 00

Adjusting method: Order Page Address Data 1 2 3 4 5 6 0 6 6 6 6 6 01 02 01 01 02 0C 13 15 01 Check the data is 00. (Note 6) Press PAUSE (Write) button. Press PAUSE (Write) button. (Note 7) Check the data changes to 01. Check the data is 00. Procedure

Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value

Note 6: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 7: The adjustment data will be automatically input to page: 6F, address: 48 to 58, 6D and 6E. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 6 6 6 6 6 0 01 01 02 01 01 00 00 Perform Flange Back Adjustment (2). 00 25 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data change to 01. Press PAUSE (Write) button.

Note 1: Perform HALL Adjustment before this adjustment. Note 2: Perform the adjustment with the lens in horizontal state. Note 3: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 4: Don't touch the zoom lever during adjustment. Note 5: After adjustment, if the focusing to a subject located at infinity failed, increase the illuminance of the chart and perform readjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT (Menu setting) ......................................... 4:3 4) COLOR SLOW S (Menu setting) ................................... OFF Preparations before adjustments: 1) Check that the center of Flange back adjustment chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.

DCR-HC47E/HC48/HC48E_ADJ 6-24

4-2. Flange Back Adjustment (2) RadarW Perform this adjustment after performing Flange Back Adjustment (1). Subject Subject more than 500 m away (Subject with clear contrast such as buildings, etc.) Adjusting remote commander 6F 48 to 58, 6D and 6E Data of page: 6, address: 0C is00

Adjusting method: Order Page Address Data 1 2 3 4 0 6 6 01 02 01 13 01 Check the data is 00. (Note 4) Press PAUSE (Write) button. Place ND filter on the lens so that the optimum image is obtain. 6 6 6 01 02 0C 29 Press PAUSE (Write) button. (Note 5) Check the data changes to 01. Check the data is 00. Procedure

Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value

5 6 7

Note 1: Perform the adjustment with the lens in horizontal state. Note 2: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 3: Dont touch the zoom lever during adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) COLOR SLOW S (Menu setting) ................................... OFF Preparations before adjustments: 1) Set the zoom lens to the TELE end and expose a subject that is more than 500 m away. (subjects with clear contrast such as building, etc.) (Nearby subjects less than 500 m away should not be in the screen)

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 5: The adjustment data will be automatically input to page: 6F, address: 48 to 58, 6D and 6E. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 6 6 6 6 6 0 01 01 02 01 01 00 00 Perform Flange Back Check. 00 25 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data change to 01. Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-25

5.

Flange Back Check

5-2. Flange Back Check (Using the Siemens star) Subject Siemens star (2.0 m from the front of the lens) (Luminance: approx. 200 lux) Check operation on monitor TV Focused at the TELE end and WIDE end

5-1. Flange Back Check (Using the flange back adjustment jig) Subject Measurement Point Measuring Instrument Specified Value Focused at the TELE end and WIDE end Flange back adjustment jig (Luminance: approx. 200 lux) Check operation on monitor

Measurement Point Measuring Instrument Specified value

Note 1: Check that the data of page: 0, address: 10 is 00. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHSHOT PLUS .......................................................... OFF 3) WIDE SELECT .................................................................. 4:3 Note 2: When the auto focus is ON, the lens can be checked if it is focused or not by observing the data on the page: 1 of the adjusting remote commander. 1 : 00 : XX Odd: Focused Even: Unfocused Preparations before adjustments: 1) Place the Siemens star 2.0 m from the front of the lens. 2) To open the IRIS, decrease the luminous intensity to the Siemens star up to a point before noise appear on the image. Checking method:

Note: Check that the data of page: 0, address: 10 is 00. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 Preparations before adjustments: 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camra is less than 3 cm. 2) To open the IRIS, decrease the liminous intensity to the chart of the flange back adjustment jig up to a point before noise appesr on the image. (approx. 200 lux) 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Checking method: Order Page Address Data 1 2 3 4 5 6 7 6 2C 02 Check that the lens is focused. Shoot the chart with the zoom WIDE end. Check that the lens is focused. 6 6 40 41 01 01 Shoot the chart with the zoom TELE end. Procedure

Order Page Address Data 1 2 3 4 5 6 7 8 0 1 6 21 10 03 0F 6 6 40 41 01 01

Procedure

Shoot the Siemens star with the zoom TELE end. Turn on the auto focus. Check that the lens is focused. (Note 2) Shoot the Siemens star with the zoom WIDE end. Observe the TV monitor and check that the lens is focused.

Processing after Completing Adjustment: Order Page Address Data 1 2 3 6 6 6 2C 40 41 00 00 00 Procedure

Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 6 6 6 0 21 40 41 03 00 00 00 00 Procedure

DCR-HC47E/HC48/HC48E_ADJ 6-26

6.

Picture Frame Setting (Center frame) Clear chart (Center frame) (1 m (PTB-450) or 40 cm (PTB1450) from the front of lens) Video terminal of A/V OUT jack (75 terminated) Monitor TV Whole of the screen is white

Subject

Measurement Point Measuring Instrument Specified Value

Note: If reading/writing data on pages 6A, set data: 06 to page: 0, address: 10, and then select pages A. By this data setting, the pages 6A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) ZOOM .................................................................... WIDE end 5) DIGITAL ZOOM (Menu setting) .................................... OFF 6) STEADY SHOT (Menu setting) ..................................... OFF 7) FOCUS (Menu Setting) ......................................... MANUAL Setting method: Order Page Address Data 1 2 3 4 0 0 A (6A) 01 10 11 01 06 91 Press PAUSE (Write) button. Check with the zoom at WIDE end that the clear chart is shot larger than the size shown in the figure. (Fig. 6-1-14) A (6A) 0 0 11 10 01 00 00 00 In the following adjustment, if the Center frame is used, adjust the clear chart to this position. Press PAUSE (Write) button. Procedure Shoot a clear chart in the center of screen with the zoom at WIDE end.
With the zoom at WIDE end, shoot the clear chart larger than this size.

Fig.6-1-14

6 7 8

DCR-HC47E/HC48/HC48E_ADJ 6-27

7.

F No. & ND Light Quality Standard Data Input

RadarW
Correct the lens iris and dispersion of the ND filter light quantity. Adjustment Page Adjustment Address 6F 1C to 23

8. MAX GAIN Adjustment RadarW Setting the minimum illumination. If it is not consistent, the image level required for taking subjects in low illuminance will not be produced (dark). Subject Clear chart (Center frame) (40 cm (PTB-1450) from the front of lens) 6F 2C

Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 0, address: 10, and set data: 06. 3) Input the following data to page: 6F, address: 1C to 23. Note 2: Press the PAUSE (Write) button of the adjustment remote commander each time to set data. Address Data 1C 1D 1E 1F 20 21 22 23 F5 F4 F8 FB FA FD F5 F4

Adjustment Page Adjustment Address

Note 1: Perform Flange Back Adjustment before this adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) ZOOM .................................................................... WIDE end 5) DIGITAL ZOOM (Menu setting) .................................... OFF 6) STEADY SHOT (Menu setting) ..................................... OFF 7) FOCUS (Menu setting) .......................................... MANUAL Adjusting method: Order Page Address Data Procedure Check that the picture frame is Center Frame. If not, perform 6. Picture Frame Setting (Center Frame) 0 6 6 6 01 02 D0 D1 20 Set the following data. 80: NTSC model B0: PAL model 6F Press PAUSE (Write) button. (Note 5) Check the data changes to 01. 01 Check the data is 00. (Note 4)

1 4) Select page: 0, address: 10, and set data: 00. 5) Select page: 0, address: 01, and set data: 00. 2 3 4 5

6 7

6 6

01 02

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 5: The adjustment data will be automatically input to page: 6F, address: 2C. Processing after Completing Adjustment: Order Page Address Data 1 2 6 0 01 01 00 00 Procedure Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-28

9. Mechanical Shutter Adjustment RadarW Adjust the close time and loss time every F number of the mechanical shutter and the high-speed shutter correction value to correct the luminous exposure. Adjustment Page Adjustment Address 6F 76 to 8B

Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 0, address: 10, and set data: 06. 3) Input the following data to page: 6F, address: 76 to 8B. Note 3: Press the PAUSE (Write) button of the adjustment remote commander each time to set data. Data NTSC 5B 8F 47 87 3E 1E 37 F8 32 5D 6A 81 8A 88 75 24 84 80 80 80 80 82 PAL 4A 86 39 BC 31 F3 2C E6 28 A1 76 84 8E 8D 7D 22 82 80 80 80 80 80

Address 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B

4) Select page: 0, address: 10, and set data: 00. 5) Select page: 0, address: 01, and set data: 00.

DCR-HC47E/HC48/HC48E_ADJ 6-29

10. Picture Frame Setting (Color reproduction adjustment frame) Subject Color bar chart (Color reproduction adjustment frame) (1 m (PTB-450) or 40 cm (PTB1450) from the front of lens) Video terminal of A/V OUT jack (75 terminated) Oscilloscope and monitor TV A=B, C=D, E=F

How to release the picture frame setting: Order Page Address Data 1 2 3 4 5 6 6 6 6 6 01 90 91 92 93 00 00 00 00 00 Procedure Press PAUSE (Write) button.

Measurement Point Measuring Instrument Specified Value

Check on the oscilloscope


1. Horizontal period

Note 1: Perform Hall Adjustment and Flange Back Adjustment before this adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS (Menu Setting) ......................................... MANUAL Setting method: Order 1 Procedure Adjust the zoom and the camera direction, and set the specified position. Mark the position of the picture frame on the monitor TV, and adjust the picture frame to the this position in following adjustment using Color reproduction adjustment frame.

A=B B A

C=D C D

Fig. 6-1-11
How to read the XH, XL, YH and YL data: Order Page Address Data 1 2 3 4 0 1 0 1 03 22 Read YH data and YL data. (Note 3)
V

2. Vertical period
E E=F F

Procedure Read XH data and XL data. (Note 3)

03

18

Note 3: The right four digits of the page: 1 displayed data of the adjusting remote commander. 1:XX : XX XL or YL data XH or YH data How to reset the zoom and focus when they deviated: If the zoom and focus deviated due to some reason, reset them in the following method. Order Page Address Data 1 2 3 4 5 6 6 6 6 6 90 91 92 93 01 XL XH YL YH 79 Press PAUSE (Write) button. Procedure

Fig. 6-1-12

Check on the monitor TV (Underscanned mode)

Color bar chart picture frame

Monitor TV picture frame

Fig. 6-1-13

DCR-HC47E/HC48/HC48E_ADJ 6-30

11. Color Reproduction Adjustment Adjust the color separation matrix coefficient so that proper color reproduction is produced. Subject Color bar chart (Color reproduction adjustment frame) Video terminal of A/V OUT jack (75 terminated) Vectorscope 6F 37, 39, 40, 41 All color luminance points should settle within each color reproduction frame.

Adjusting method: Order Page Address Data Procedure Check that the picture frame is Color Reproduction Adjustment Frame. If not, perform 6. Picture Frame Setting (Color Reproduction Adjustment Frame) 0 6 6 01 02 D0 01 Check the data change to 01. Set the following data, and press PAUSE (Write) button. 7C: NTSC model 82: PAL model 3D 06 Set the following data, and press PAUSE (Write) button. 77: NTSC model F7: PAL model Adjust the GAIN and PHASE of the vectorscope, and set to the burst luminance point to the burst position of color reproduction frame. F (6F) 0 37 39 40 41 10 00 Change the data and settle each color luminance point in each color reproduction frame. (Note 5) Press PAUSE (Write) button.

Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value

2 3 4

Note 1: If reading/writing data on pages 66, 6F, set data: 06 to page: 0, address: 10, and then select pages: 6, F. By this data setting, the pages 66, 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 2: Perform Hall Adjustment and Flange Back Adjustment before this adjustment. Note 3: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting: 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADYSHOT (Menu setting) ...................................... OFF 6) FOCUS (Menu setting) .......................................... MANUAL

5 6 7

6 0 6 (66)

01 10 00

9 10

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 5: Be sure to press the PAUSE (Write) button of the adjusting remote commander before changing the addresses. If not, the new data will not be written to the memory. Processing after completing adjustment: Order Page Address Data 1 2 3 4 6 6 0 01 D0 01 00 00 00 Perform Color Reproduction Check. Procedure Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-31

NTSC model
R-Y MG R

YE B-Y B

Burst position

G CY

PAL model
R-Y

Burst position

MG

YE B-Y

B G CY

Fig. 6-1-15

DCR-HC47E/HC48/HC48E_ADJ 6-32

12. Color Reproduction Check RadarW Subject Measurement Point Measuring Instrument Color bar chart (Color reproduction adjustment frame) Video terminal of A/V OUT jack (75 terminated) Vectorscope Adjusting remote commander Data of page: 6, address: 0C is 00

Checking method: Order Page Address Data Procedure Check that the picture frame is Color Reproduction Adjustment Frame. If not, perform 6. Picture Frame Setting (Color Reproduction Adjustment Frame) 0 6 01 02 01 Check the data is 00. (Note 5) Set the following data, and press PAUSE (Write) button 7C: NTSC model 82: PAL model 4D Press PAUSE (Write) button. (Note 6) Check the data changes to 01. Check the data is 00.

2 3

Specified Value

All color luminance points should settle within each color reproduction frame.

D0

Note 1: Perform Color Reproduction Adjustment before this adjustment. Note 2: Perform this along with the Color Reproduction Adjustment successively. Note 3: Check that the data of page: 0, address: 10 is 00. Note 4: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS (Menu setting) .......................................... MANUAL

5 6 7

6 6 6

01 02 0C

Note 5: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 6: Confirm that the Y signal level (A) is 905 IRE. (Refer to Fig 6-1-16) 905 IRE = 606.9 to 678.3 mV (NTSC) 905 IRE = 595 to 665 mV (PAL) Processing after Completing Adjustment: Order Page Address Data 1 2 3 6 6 0 01 D0 01 00 00 00 Procedure Press PAUSE (Write) button.

White

Fig.6-1-16

DCR-HC47E/HC48/HC48E_ADJ 6-33

13. Picture Frame Setting (AWB Adjustment frame) Subject Clear chart (AWB Adjustment frame) (1 m (PTB-450) or 40 cm (PTB-1450) from the front of lens) Video terminal of A/V OUT jack (75 terminated) Monitor TV Only the clear chart must be shot (entire screen is white).

How to reset the zoom and focus when they deviated: If the zoom and focus deviated due to some reason, reset them in the following method. Order Page Address Data 1 2 3 4 5 6 6 6 6 6 90 91 92 93 01 XL XH YL YH 79 Press PAUSE (Write) button Procedure

Measurement Point Measuring Instrument Specified Value

Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: The right four digits of the page: 1 displayed data of the adjusting remote commander. 1:XX : XX XL or YL data XH or YH data Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS ................................................................... MANUAL Setting method: Order Page Address Data 1 Procedure Perform 7. Picture Frame Setting (Color reproduction adjustment frame). By zooming in the color reproduction adjustment picture frame, set up the picture frame in which the color bar is shot on full screen. (Refer to Fig. 6-1-17) Remove the Color bar chart from the pattern box. Check that whole of the screen is white. 0 1 0 1 0 03 00 In the following adjustment, if the AWB Adjustment frame is used, adjust the clear chart to this position. 03 22 Read YH data and YL data. (Note 2) 03 18 Read XH data and XL data. (Note 2)

Processing after Completing Adjustment: Reset the data setting after the adjustment finished. Order Page Address Data 1 2 3 4 5 6 6 6 6 6 01 90 91 92 93 00 00 00 00 00 Procedure Press PAUSE (Write) button.

Check on the monitor TV (Underscanned mode)

Color bar chart picture frame

Monitor TV picture frame

Fig. 6-1-17

3 4 5 6 7 8 9 10

DCR-HC47E/HC48/HC48E_ADJ 6-34

14. Auto White Balance Standard Data Input RadarW Adjust the white balance reference at 3200K, and adjust the normal coefficient of the light value. Subject Adjustment Page Adjustment Address Clear chart (AWB Adjustment Frame) (Note 3) 6F 2E to 31, E8 to EB

15. LV Standard Data Input RadarW Adjust the normal coefficient of the light value at 3200K. Subject Measuring Instrument Adjustment Page Adjustment Address Clear chart (AWB Adjustment Frame) (Note 3) Adjusting remote commander 6F 2A, 2B

Note 1: Perform Color Reproduction Adjustment before this adjustment. Note 2: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 3: Perform 13. Picture Frame Setting (AWB Adjustment Frame) before this adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS (Menu setting) .......................................... MANUAL Adjusting method: Order Page Address Data Procedure Check that the picture frame is AWB Adjustment Frame. If not, perform 13. Picture Frame Setting (AWB Adjustment Frame) 0 6 01 02 01 Check the data is 00. (Note 4) Wait for 2 seconds. 6 6 6 01 01 02 43 41 Press PAUSE (Write) button. Press PAUSE (Write) button. (Note 5) Check the data changes to 01.

Note 1: Perform F No. & ND Light Quality Standard Data Input and Auto White Balance Standard Data Input before this adjustment. Note 2: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 3: Perform 13. Picture Frame Setting (AWB Adjustment Frame) before this adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS (Menu setting) .......................................... MANUAL Adjusting method: Order Page Address Data Procedure Check that the picture frame is AWB Adjustment Frame. If not, perform 13. Picture Frame Setting (AWB Adjustment Frame) 0 6 6 6 01 02 01 02 0D 01 Check the data is 00. (Note 4) Press PAUSE (Write) button. (Note 5) Check the data changes to 01.

2 3 4 5 6 7

2 3 4 5

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 5: The adjustment data will be automatically input to page: 6F, address: 2E to 31, E8 to F3. Processing after Completing Adjustment: Order Page Address Data 1 2 6 0 01 01 00 00 Procedure Press PAUSE (Write) button.

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 5: The adjustment data will be automatically input to page: 6F, address: 2A, 2B. Processing after Completing Adjustment: Order Page Address Data 1 2 6 0 01 01 00 00 Procedure Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-35

16. Auto White Balance Adjustment RadarW Adjust to the proper auto white balance output data. If it is not correct, auto white balance and color reproducibility will be poor. Subject Filter Adjustment Page Adjustment Address Clear chart (AWB Adjustment Frame) (Note 3) Filter C14 for color temperature correction 6F 32 to 35, 44 to 47, F4 to F7

Adjusting method: Order Page Address Data Procedure Check that the picture frame is AWB Adjustment Frame. If not, perform 13. Picture Frame Setting (AWB Adjustment Frame) 0 6 0 F (6F) 6 F (6F) F (6F) 8 9 10 11 12 13 0 6 6 6 10 01 01 02 00 47 45 Press PAUSE (Write) button. Press PAUSE (Write) button. (Note 5) Check the data changes to 01. F (6F) Place the C14 filter on the lens. 47 98 Press PAUSE (Write) button. 45 Set the following data, and press PAUSE (Write) button. 4E: NTSC model AE: PAL model 5C Press PAUSE (Write) button. 01 02 10 44 06 2A Press PAUSE (Write) button. 01 Check the data is 00. (Note 4)

2 3 4 5

Note 1: Perform F No. & ND Light Quality Standard Data Input and Auto White Balance Standard Data Input before this adjustment. Note 2: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Note 3: Perform 13. Picture Frame Setting (AWB Adjustment Frame) before this adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS (Menu setting) .......................................... MANUAL

46

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 5: The adjustment data will be automatically input to page: 6F, address: 32 to 35, F4 to F7. Processing after Completing Adjustment: Order Page Address Data 1 2 3 6 0 01 01 00 00 Remove the C14 filter on the lens. Procedure Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-36

17. Auto White Balance Check RadarW Subject Filter Measuring Instrument Specified Value Clear chart (AWB Adjustment Frame) (Note 3) ND filter 1.0, 0.4 and 0.1 Adjusting remote commander Data of page: 6, address: 0C is 00

Checking method: Order Page Address Data 1 Procedure Check that the picture frame is AWB Adjustment Frame. If not, perform 13. Picture Frame Setting (AWB Adjustment Frame) 6 02 Check the data is 00. (Note 4) C1 Press PAUSE (Write) button. Check the data changes to 01. Check the data is 00. 00 Press PAUSE (Write) button. Place the ND filter 1.5 (1.0 + 0.4 + 0.1) on the lens. 6 6 6 01 02 0C 4B Press PAUSE (Write) button Check the data changes to 01. Check the data is 00. Remove the ND filter 1.5 (1.0 + 0.4 + 0.1) on the lens.

Note 1: Perform Color Reproduction Adjustment and Auto White Balance Adjustment before this adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: Perform 13. Picture Frame Setting (AWB Adjustment Frame) before this adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHTSHOT PLUS ........................................................ OFF 3) WIDE SELECT .................................................................. 4:3 4) DIGITAL ZOOM (Menu setting) .................................... OFF 5) STEADY SHOT (Menu setting) ..................................... OFF 6) FOCUS (Menu setting) .......................................... MANUAL

Auto white balance check 3 4 5 6 6 6 6 6 01 02 0C 01

InOut data check 7 8 9 10 11

Note 4: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Processing after Completing Adjustment: Order Page Address Data 1 6 01 00 Procedure Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-37

18. Steady Shot Check RadarW Precautions on the Parts Replacement There are two types of repair parts. Type A ENC03MA Type B ENC03MB Replace the broken sensor with a same type sensor. If replace with other type parts, the image will vibrate up and down or left and right during hand-shake correction operations. Precautions on Angular Velocity Sensor The sensor incorporates a precision oscillator. Handle it with care as if it dropped, the balance of the oscillator will be disrupted and operations will not be performed properly. Subject Measurement Point Measuring Instrument Specified value Not required Displayed data of page: 1 (Note 1) Adjusting remote commander PITCH data: 2680 to 5080 YAW data: 2680 to 5080

Note 1: The right four digits of the page: 1 displayed data of the adjusting remote commander. 1 : XX : XX Displayed data Note 2: Check that the data of page: 0, address: 10 is 00. Switch setting 1) ZOOM ..................................................................... TELE end 2) STEADY SHOT (Menu setting) ....................................... ON Checking method: Order Page Address Data 1 2 0 1 03 11 With the set in still state, check that the displayed data (Note 1) satisfies the PITCH data specified value. 03 12 With the set in still state, check that the displayed data (Note 1) satisfies the YAW data specified value. 03 00 Shake the set vertically and horizontally to check that the steady shot function operates normally. Procedure PITCH sensor output check (SE7002 of CD-672 board)

YAW sensor output check (SE7001 of CD-672 board) 3 4 5 0 1 0

Steady shot operation check 6

DCR-HC47E/HC48/HC48E_ADJ 6-38

1-4.

ELECTRONIC VIEWFINDER SYSTEM

Adjusting method: Order Page Address Data Procedure 1 0 01 01 2 C 71 00 Press PAUSE (Write) button. 3 3 03 FF Press PAUSE (Write) button. 4 3 01 5A Press PAUSE (Write) button. (Note 4) 5 3 02 Check the data changes to 00. 6 3 03 Check the data is 00. (Note 5) Read the data and this data is 7 C 3F named D3F. Convert D3F to decimal notation, and obtain D3F. 8 (Note 6) Calculate D40 using following equations. 9 (decimal calculation) D40 = D3F + 10 (NTSC model) D40 = D3F 10 (PAL model) Convert D40 to a hexadecimal number, and obtain D40. 10 (Note 6) 11 C 40 D40 Press PAUSE (Write) button. 12 C 71 41 Press PAUSE (Write) button. 13 0 01 00 Note 4: The adjustment data will be automatically input to page: C, address: 3F and 47. Note 5: If the data change to 01, adjustment has error. Contents of error is written into page: 3, address: C6. See the following table. Note 6: Refer to table 6-4-1. Hexadecimal-decimal conversion table. Data of page: 3, address: C6 5E 61 Contents of error VCO adjustment error Contrast adjustment error

ADJUSTMENTS Before perform the electronic viewfinder system adjustments, check that the data of page: 0, address: 10 is 00. If not, select page: 0, address: 10, and set the data 00. Note 1: Taken an extreme care not to destroy the liquid crystal display module by static electricity when replacing it. Note 2: Perform the following data setting before the viewfinder system adjustments. 1) Select page: 3, address: C4, and set data: 69. 2) Select page: 3, address: C5, and set data: 02. Reset the data after completing adjustment. 1) Select page: 3, address: C4, and set data: 00. 2) Select page: 3, address: C5, and set data: 00. 1. EVF Automatic Adjustment (VC-472 board)

RadarW
This adjustment does the following items automatically. VCO Adjustment Contrast Adjustment Mode Signal Adjustment Page Adjustment Address VTR stop (PLAY/EDIT mode) No signal C 3F, 40 (VCO Adjustment) 47 (Contrast Adjustment)

Note 1: Perform this adjustments after perfoming IC4701 Automatic adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting WIDE SELECT ......................................................................... 4:3

DCR-HC47E/HC48/HC48E_ADJ 6-39

2. White Balance Adjustment (VC-472 board) Correct the white balance. If deviated, the EVF screen color cannot be reproduced. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value C 45, 46 EVF screen must not be colored VTR stop (PLAY/EDIT mode) No signal Check on EVF screen

Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: Check the white balance only when replacing the following parts. If necessary, adjust them. 1. LCD panel 2. Light induction plate 3. IC7001 Adjusting method: Order Page Address Data 1 2 3 4 45 46 01 00 0 C C 01 45 46 01 7E 7B Press PAUSE (Write) button. Press PAUSE (Write) button. Check that the EVF screen is not colored. If not colored, proceed to step 6. C 0 Change the data so that the EVF screen is not colored. (Note 3) Procedure

5 6

Note 3: To write in the non-volatile memory (EEPROM), press the PAUSE (Write) button each time to set the data.

DCR-HC47E/HC48/HC48E_ADJ 6-40

1-5.

LCD SYSTEM ADJUSTMENTS

Adjusting method: Order Page Address Data 1 2 3 4 5 0 C 3 3 3 3 C 01 70 03 01 02 03 50 01 00 FF 5A Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. (Note 4) Check the data changs to 00. Check the data is00. (Note 5) Read the data and this data is named D50. Convert D50 to decimal notation, and obtain D50. (Note 6) Calculate D51 using following equations. (decimal calculation) D51 = D50 + 10 (NTSC model) D51 = D50 10 (PAL model) Convert D51 to a hexadecimal number, and obtain D51. (Note 6) C C 0 51 70 01 D51 41 00 Press PAUSE (Write) button. Press PAUSE (Write) button. Procedure

Before perform the LCD system adjustments, check that the data of page: 0, address: 10 is 00. If not, select page: 0, address: 10, and set the data 00. Note 1: Taken an extreme care not to destroy the liquid crystal display module by static electricity when replacing it. Note 2: Set the LCD BRIGHT, LCD COLOR to the center with the menu settings of the touch panel. Note 3: Open the LCD panel during the LCD system adjustment. 1. LCD Automatic Adjustment (VC-472 board)

6 7

RadarW
This adjustment does the following items automatically. VCO Adjustment Contrast Adjustment Mode Signal Adjustment Page Adjustment Address VTR stop (PLAY/EDIT mode) No signal C 50, 51 (VCO Adjustment) 58 (Contrast Adjustment) Note 1: Perform this adjustment after performing IC4701 Automatic Adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting WIDE SELECT ....................................................................... 16:9

10 11 12 13

Note 4: The adjustment data will be automatically input to page: C, address: 50 and 58. Note 5: If the data change to 01, adjustment has error. Contents of error is written into page: 3, address: C6. See the following table. Note 6: Refer to table 6-4-1. Hexadecimal-decimal conversion table. Data of page: 3, address: C6 Contents of error 58 60 VCO adjustment error Contrast adjustment error

DCR-HC47E/HC48/HC48E_ADJ 6-41

2. V-COM Adjustment (VC-472 board) Set the DC bias of the common electrode drive signal of LCD to the specified value. If deviated, the LCD display will be move, producing flicker and conspicuous vertical lines. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value C 52 The brightness difference between the section-A and section-B is minimum VTR stop (PLAY/EDIT mode) No signal Check on LCD screen

3.

Transmissive Mode White Balance Adjustment (VC-472 board) Correct the white balance at transmissive mode. If deviated, the LCD screen color cannot be reproduced. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value C 56, 57 LCD screen must not be colored VTR stop (PLAY/EDIT mode) No signal Check on LCD screen

Note 1: Perform LCD Automatic Adjustment before this adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Switch setting LCD BACKLIGHT .................................................................. ON Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 0 C C C C C 0 01 61 52 52 52 61 01 05 00 01 CD Press PAUSE (Write) button. Change the data so that brightness of the section A and section B is equal. Subtract 7 from the data. Press PAUSE (Write) button. Press PAUSE (Write) button. Procedure

Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: Check the white balance only when replacing the following parts. If necessary, adjust them. 1. LCD block 2. Light induction plate 3. IC7001 Adjusting method: Order Page Address Data 1 2 3 4 0 C C 01 56 57 01 7D 73 Press PAUSE (Write) button. Press PAUSE (Write) button. Check that the LCD screen is not colored. If not colored, proceed to step 6. C 0 56 57 01 00 Change the data so that the LCD screen is not colored. (Note 3) Procedure

5 6

Note 3: To write in the non-volatile memory (EEPROM), press the PAUSE (Write) button each time to set the data.

Fig. 6-1-18

DCR-HC47E/HC48/HC48E_ADJ 6-42

4. Touch Panel Adjustment Adjust the calibration of touch panel. Mode Signal Adjustment Page Adjustment Address VTR stop (PLAY/EDIT mode) Arbitrary A 90 to 93

Note 1: This adjustment should be carried out upon completetion of 1. LCD Automatic Adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: Check that a Memory Stick Duo is not insteted. Note 4: Check that the LCD panel is not reverse mode. Note 5: Adjustment must be performed while observing the LCD screen from the front. Preparation: Order Page Address Data 1 2 3 4 7 7 01 00 C9 01 Press PAUSE (Write) button. Check that the touch panel adjustment screen is displayed. Perform Adjusting method. Procedure

Adjusting method: 1) Using a ball-point pen etc., push the center of indicated in the part A. 2) Using a ball-point pen etc., push the center of indicated in the part B. 3) Using a ball-point pen etc., push the center of indicated in the part C.

A C

Fig. 6-1-19

DCR-HC47E/HC48/HC48E_ADJ 6-43

6-2. MECHANISM SECTION ADJUSTMENTS


On the mechanism section adjustment For details of mechanism section adjustments, checks, and replacement of mechanism parts, refer to the separate volume DV MECHANICAL ADJUSTMENT MANUAL IX N Mechanism . Note 1: Before performing the adjustments, check the data of page: 0, address: 10 is 00. If not, set data: 00 to this address.

5) Playback the alignment tape for tracking. (XH2-1) 6) Select page: 3, address: 33, and set data: 08. 7) Select page: 3, address: 26, set data: 31, and press the PAUSE (Write) button. 8) Check that the oscilloscope RF waveform is normal at the entrance and exit. If not normal, adjust according to the separate volume DV MECHANICAL ADJUSTMENT MANUAL IX N Mechanism .

2-1.

HOW TO ENTER RECORD MODE WITHOUT CASSETTE

CN1014 of VC-472 board Pin No. Signal Name 1 2 3 4 5 6 7 8 RF_MON SWP GND XCS EEP EEP SCK EEP SO EEP SI GND

1) Connect the multi cable for service (J-6082-535-A) to the A/V OUT jack. 2) Connect the adjustment remote commander to the LANC socket of multi cable for service. Set the HOLD switch to ON. (Set the slide switch to SERVICE) 3) Close the cassette compartment without the cassette. 4) Select page: 3, address: 01, set data: 0C, and press the PAUSE (Write) button of the adjustment remote commander. (The mechanism enters the record mode automatically.) Note: The function buttons become inoperable. 5) To quit the record mode, select page: 3, address: 01, set data: 00, and press the PAUSE (Write) button of the adjustment remote commander. (Whenever you want to quit the record mode, be sure to quit following this procedure.)

2-2.

HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE

2. Procedure after operations 1) Connect the adjustment remote commander to the LANC socket of multi cable for service. Set the HOLD switch to ON. (Set the slide switch to SERVICE) 2) Select page: 3, address: 26, set data: 00, and press the PAUSE (Write) button. 3) Select page: 3, address: 33, and set data: 00.
Entrance side Check this section (Normal waveform) Exit side

1) Connect the multi cable for service (J-6082-535-A) to the A/V OUT jack. 2) Connect the adjustment remote commander to the LANC socket of multi cable for service. Set the HOLD switch to ON. (Set the slide switch to SERVICE) 3) Close the cassette compartment without the cassette. 4) Select page: 3, address: 01, set data: 0B, and press the PAUSE (Write) button of the adjustment remote commander. (The mechanism enters the playback mode automatically.) Note: The function buttons become inoperable. 5) To quit the playback mode, select page: 3, address: 01, set data: 00, and press the PAUSE (Write) button of the adjustment remote commander. (Whenever you want to quit the playback mode, be sure to quit following this procedure.)

CH1

2-3.

TAPE PATH ADJUSTMENT

CH2 (Trigger) 3.3msec

1. Preparation for Adjustment 1) Clean the tape runnung side (tape guide, drum, capstan shaft, pinch roller, etc.). 2) Connect the multi cable for service (J-6082-535-A) to the A/V OUT jack. 3) Connect the adjustment remote commander to the LANC socket of multi cable for service. Set the HOLD switch to ON. (Set the slide switch to SERVICE) 4) Connect an oscilloscope to CN1014 of VC-472 board via CPC15 (J-6082-564-A) and I/F unit for LANC control (J-6082521-A). Channel 1: VC-472 board, CN1014 Pin 1 (Note) External trigger: VC-472 board, CN1014 Pin 2 Note: Connect a 75 resistor between pins 1 of CN1014 and 3 (GND). 75 resistor (Parts code: 1-247-804-11)

Fig. 6-2-1

DCR-HC47E/HC48/HC48E_ADJ 6-44

6-3. VIDEO SECTION ADJUSTMENTS


3-1. PREPARATIONS BEFORE ADJUSTMENTS

Use the following measuring instruments for video section adjustments. 3-1-1. Precautions on Adjusting Note: Before performing the adjustment, check the data of page: 0, address: 10 is 00. If not, select page: 0, address: 00, and set data 00. 1) The adjustments of this unit are performed in the VTR mode (PLAY/EDIT mode) or camera mode (CAMERA-TAPE mode).

3-1-2. Adjusting Connectors The measuring point of the playback RF signal is CN1014 of VC472 board. Connect the measuring instruments via the CPC-15 jig (J-6082-564-A) and I/F unit for LANC control (J-6082-521-A). Refer to MECHANISM SECTION ADJUSTMENT for the measuring method. The following table lists the pin numbers and signal names of CN1014. Pin No. Signal Name 1 2 3 4 5 6 7 8 RF_MON SWP GND XCS EEP EEP SCK EEP SO EEP SI GND

3-1-3. Connecting the Equipment Connect the measuring instruments as shown in Fig. 6-3-1, and perform the adjustments.

Table 6-3-1

For tape path adjustment

A/V OUT jack


Not used
BATT

CN001
6 4 1 3 7 5 3 2

CPC-15 (J-6082-564-A) 8

A/V OUT

LANC Not used

Not used CN002

*1

*1

CPC lid AC adaptor To DC IN jack AC IN

1 RF MON 2 SWP 3 GND 4 XSC EEP I/F unit for LANC control 5 EEP SCK (J-6082-521-A) 6 EEP SO Not used. 7 EEP SI *1: Don't connect any cable Adjustment remote to these connectors. commander

Multi cable for service (J-6082-535-A) Audio L Audio R Video

(NEW LANC JIG)

Camera system Adjustment Vectorscope Terminated 75 Color monitor

(RM-95)

Video system Adjustment Osilloscope Terminated 75

S-Video or Video

Fig. 6-3-1

DCR-HC47E/HC48/HC48E_ADJ 6-45

3-1-4. Alignment Tapes Use the alignment tapes shown in the following table. Use tapes specified in the signal column of each adjustment. Name Tracking standard (XH2-1) SW/OL standard (XH2-3) Use Tape path adjustment Switching position adjustment

Audio operation check Audio system adjustment (XH5-3 (NTSC), XH5-3P (PAL)) System operation check Operation check (XH5-5 (NTSC), XH5-5P (PAL)) Fig. 6-3-2 shows the 75% color bar signals recorded on the alignment tape for Audio Operation Check. Note: Measure with video terminal (Terminated at 75 ) For NTSC model
White (100%)

Yellow

White (75%)

Cyan Green Magenta Red Blue

Yellow

Green

Cyan

Red

0.714 V 1V

(75%) 0.286 V

0.286 V

Q White (100%)

Black

Horizontal sync signal Color bar signal waveform

Color bar pattern

For PAL model


Yellow Cyan Green

White (100%)

White

Cyan

Red

Blue

0.3 V 0.3 V Burst signal (100%)

Horizontal sync signal


Color bar signal waveform

Color bar pattern

Fig. 6-3-2. Color bar signal of alignment tapes


3-1-5. Output Level and Impedance Video output A/V OUT jack Video signal: 1 Vp-p, 75 unbalanced, sync negative S video output A/V OUT jack Luminance signal: 1 Vp-p, 75 unbalanced, sync negative Chrominance signal: 0.286 Vp-p, 75 unbalanced (NTSC) : 0.300 Vp-p, 75 unbalanced (PAL)

Audio output A/V OUT jack Input impedance: More than 47 k Output level: 327 mV (at load impedance 47 k) Output impedance: Below 2.2 k

DCR-HC47E/HC48/HC48E_ADJ 6-46

Black

1V

Magenta

Yellow

Green

0.7 V

Magenta Red Blue

Blue

Burst signal

Magenta

White

3-2.

SYSTEM CONTROL SYSTEM ADJUSTMENTS

D1 (decimal) 00001 to 65535 65536 to 131071 131072 to196607

D2 (decimal) D1 D1 65536 D1 131072

H1 (hexadecimal) (Service model code) FE FE FE FE FE FE FE FE FE FE FE FE FE FE FE FE

1. Initialization of EEPROM Data If the EEPROM data is erased due to some reason, perform 1-2. INITIALIZATION OF EVR DATA , of 6-1. CAMERA SECTION ADJUSTMENT 2. Node Unique ID No. Input Note 1: Perform 2-2. Input of Serial No. if the data on page C has been cleared and Original node unique ID No. is uncertain. Usually, read the data on page C before repair, and write it after repair. Note 2: Check that the data of page: 0, address: 10 is 00. 2-1. Input of Company ID Write the company ID to the EEPROM (nonvolatile memory). Page Address C E0, E1, E2, E3, E4

196608 to 262143 D1 196608 262144 to 327679 D1 262144 327680 to 393215 D1 327680 393216 to 458751 D1 393216 458752 to 524287 D1 458752 524288 to 589823 D1 524288 589824 to 655359 D1 589824 655360 to 720895 D1 655360 720896 to 786431 D1 720896 786432 to 851967 D1 786432

Input method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: C, and enter the following data. Note 3: Each time the data is set, press the PAUSE (Write) button on the adjusting remote commander. Address E0 E1 E2 E3 E4 Data 08 00 46 01 02

851968 to 917503 D1 851968 917504 to 983039 D1 917504 983040 to 999999 D1 983040

Table 6-3-2
4) Enter H1 to address: E5 on page: C. Example: If H1 = FE, select page: C, address: E5, and set data: FE, then press the PAUSE (Write) button. 5) From Table 6-3-3, obtain the maximum decimal number less than D2, and it is assumed to be D3. Example: If D2 = 12345. D3 = 12288 6) From Table 6-3-3, obtain a hexadecimal number that corresponds to D3, and it is assumed to be H3. Example: If D3 = 12288, H3 = 3000 7) Caluculate D 4 using following equations (decimal caluculation). (0 D4 225) D 4 = D2 D 3 Example: If D2 = 12345 and D3 = 12288, D4 = 12345 12288 = 57 8) Convert D4 into a hexadecimal number to obtain H4. (See Table 6-4-1 Hexadecimal - decimal conversion table in 6-4. Service Mode) Example: If D4 = 57, H4 = 39 9) Enter higher two digits of H3 to address: E6 on page: C. Example: If H3 = 3000, select page: C, address: E6, and set data: 30, then press the PAUSE (Write) button. 10) Enter H4 to address: E7 on page: C. Example: If H4 = 39, select page: C, address: E7, and set data: 39, then press the PAUSE (Write) button. 11) Select page: 0, address: 01, and set data: 00.

3) Select page: 0, address: 01, and set data: 00. 2-2. Input of Serial No. Write the serial No. and model code to the EEPROM (nonvolatile memory). In writing the serial No., a decimal number should be converted into a hexadecimal number. Page Address C E5, E6, E7

1) Select page: 0, address: 01, and set data: 01. 2) Read the serial No. from the model name label, and it is assumed to be D1. Example: If serial No. is 77881, D1 = 77881 3) From Table 6-3-2, obtain D2 and H1 that correspond to D1. Example: If D1 = 77881, D2 = D1 65536 = 12345 H1 = FE

DCR-HC47E/HC48/HC48E_ADJ 6-47

D3 0 256 512 768 1024 1280 1536 1792 2048 2304 2560 2816 3072 3328 3584 3840 4096 4352 4608 4864 5120 5376 5632 5888 6144 6400 6656 6912 7168 7424 7680 7936

H3 0000 0100 0200 0300 0400 0500 0600 0700 0800 0900 0A00 0B00 0C00 0D00 0E00 0F00 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 1A00 1B00 1C00 1D00 1E00 1F00

D3 8192 8448 8704 8960 9216 9472 9728 9984 10240 10496 10752 11008 11264 11520 11776 12032 12288 12544 12800 13056 13312 13568 13824 14080 14336 14592 14848 15104 15360 15616 15872 16128

H3 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 2A00 2B00 2C00 2D00 2E00 2F00 3000 3100 3200 3300 3400 3500 3600 3700 3800 3900 3A00 3B00 3C00 3D00 3E00 3F00

D3 16384 16640 16896 17152 17408 17664 17920 18176 18432 18688 18944 19200 19456 19712 19968 20224 20480 20736 20992 21248 21504 21760 22016 22272 22528 22784 23040 23296 23552 23808 24064 24320

H3 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 4A00 4B00 4C00 4D00 4E00 4F00 5000 5100 5200 5300 5400 5500 5600 5700 5800 5900 5A00 5B00 5C00 5D00 5E00 5F00

D3 24576 24832 25088 25344 25600 25856 26112 26368 26624 26880 27136 27392 27648 27904 28160 28416 28672 28928 29184 29440 29696 29952 30208 30464 30720 30976 31232 31488 31744 32000 32256 32512

H3 6000 6100 6200 6300 6400 6500 6600 6700 6800 6900 6A00 6B00 6C00 6D00 6E00 6F00 7000 7100 7200 7300 7400 7500 7600 7700 7800 7900 7A00 7B00 7C00 7D00 7E00 7F00

D3 32768 33024 33280 33536 33792 34048 34304 34560 34816 35072 35328 35584 35840 36096 36352 36608 36864 37120 37376 37632 37888 38144 38400 38656 38912 39168 39424 39680 39936 40192 40448 40704

H3 8000 8100 8200 8300 8400 8500 8600 8700 8800 8900 8A00 8B00 8C00 8D00 8E00 8F00 9000 9100 9200 9300 9400 9500 9600 9700 9800 9900 9A00 9B00 9C00 9D00 9E00 9F00

D3 40960 41216 41472 41728 41984 42240 42496 42752 43008

H3 A000 A100 A200 A300 A400 A500 A600 A700 A800

D3 49152 49408 49664 49920 50176 50432 50688 50944 51200

H3 C000 C100 C200 C300 C400 C500 C600 C700 C800

D3 57344 57600 57856 58112 58368 58624 58880 59136 59392

H3 E000 E100 E200 E300 E400 E500 E600 E700 E800 E900 EA00 EB00 EC00 ED00 EE00 EF00 F000 F100 F200 F300 F400 F500 F600 F700 F800 F900 FA00 FB00 FC00 FD00 FE00 FF00

43264 A900 51456 C900 59648 43520 AA00 51712 CA00 59904 43776 AB00 51968 44032 AC00 52224 CB00 CC00 60160 60416

44288 AD00 52480 CD00 60672 44544 AE00 52736 CE00 60928 44800 45056 45312 45568 45824 46080 46336 46592 46848 47104 47360 47616 47872 AF00 B000 B100 B200 B300 B400 B500 B600 B700 B800 B900 BA00 BB00 52992 53248 53504 53760 54016 54272 54528 54784 55040 55296 55552 CF00 D000 D100 D200 D300 D400 D500 D600 D700 D800 D900 61184 61440 61696 61952 62208 62464 62720 62976 63232 63488 63744

55808 DA00 64000 56064 DB00 64256

48128 BC00 56320 DC00 64512 48384 BD00 56576 DD00 64768 48640 48896 BE00 BF00 56832 57088 DE00 DF00 65024 65280

Note: D3: Decimal H3: Hexadecimal

Table 6-3-3

DCR-HC47E/HC48/HC48E_ADJ 6-48

3. USB Serial Number Data Setting Set the serial number data of the USB. Note 1: Before the repair, read the data of the set to be repaired, and write the read data after the repair. Perform 3-1. Model Number Input and 3-2. Serial Number Input, if the data on page B is erased and original USB serial number is unknown. Note 2: Check that the data of page: 0, address: 10 is 00. 3-1. Model Number Input Write the model number to the EEPROM (nonvolatile memory). For the model number, enter the ASCII codes that correspond to the last 5 characters of the model name given on the model name label of the set. Page Address B D1, D2, D3, D4, D5

3-2. Serial Number Input Write the serial number to the EEPROM (nonvolatile memory). For the serial number, set the serial number given on the model name label of the set. Page Address B D6, D7, D8, D9

Input method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: B, and enter the following data. Note 5: Each time the data is set, press the PAUSE (Write) button on the adjusting remote commander. Address D6 D7 D8 D9 Data First and first 2nd digits of serial number First 3rd and 4th digits of serial number First 5th and 6th digits of serial number First 7th and 8th digits of serial number

Input method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: B, and enter the following data. Note 3: Each time the data is set, press the PAUSE (Write) button on the adjusting remote commander.

Note 6: If the serial number is less than 8 digits, set 0 at the top of serial number by the amount of shortage of digits. Example: If the serial number is 1234567, set 01234567. D6 = 01 D7 = 23 D8 = 45 D9 = 67 3) Select page: 0, address: 01, and set data: 00. Charactor ASCII Code 20 * 2a 0 30 : 3a @ 40 J 4a P 50 Z 5a ` 60 j 6a p 70 z 7a Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code Charactor ASCII Code ! 21 + 2b 1 31 ; 3b A 41 K 4b Q 51 [ 5b a 61 k 6b q 71 { 7b " 22 , 2c 2 32 < 3c B 42 L 4c R 52 5c b 62 l 6c r 72 | 7c # 23 2d 3 33 = 3d C 43 M 4d S 53 ] 5d c 63 m 6d s 73 } 7d $ 24 . 2e 4 34 > 3e D 44 N 4e T 54 ^ 5e d 64 n 6e t 74 ~ 7e % 25 / 2f 5 35 ? 3f E 45 O 4f U 55 _ 5f e 65 o 6f u 75 v 76 w 77 x 78 y 79 f 66 g 67 h 68 i 69 V 56 W 57 X 58 Y 59 F 46 G 47 H 48 I 49 6 36 7 37 8 38 9 39 & 26 ' 27 ( 28 ) 29

Address D1 D2 D3 D4 D5

Data Last 5th character on model name label (Note 4) Last 4th character on model name label Last 3rd character on model name label Last 2nd character on model name label Last character on model name label

Note 4: If the model name is less than 5 characters, justify the codes to the right and set "20" for the remainder. Example: If the model name is DCR-HC47E, set 4843343745. D1 = 48 D2 = 43 D3 = 34 D4 = 37 D5 = 45 3) Select page: 0, address: 01, and set data: 00.

Table 6-3-4

DCR-HC47E/HC48/HC48E_ADJ 6-49

3-3.

SERVO AND RF SYSTEM ADJUSTMENTS

Before perform the servo and RF system adjustments, check that the specified values of 33MHz/27MHz Origin Oscillation Check of 1-3. CAMERA SYSTEM ADJUSTMENTS is satisfied. Check that the data of page: 0, address: 10 is 00. If not, select page: 0, address: 10, and set the data 00. Adjusting Procedure: 1. CAP FG duty adjustment 2. Switching position adjustment 3. Error rate check 1. CAP FG Duty Adjustment (VC-472 board)

RadarW
Set the CAP FG signal duty cycle to 50% to establish an appropriate capstan servo. If deviated, the uneven rotation of capstan and noise can occur in the LP mode. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value VTR stop (PLAY/EDIT mode) No signal Displayed data of page: 3, address: 03 Adjusting remote commander C 16 The data of page: 3, address: 03 is 00

Note 1: Check that the data of page: 0, address: 10 is 00. Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 0 C 3 3 3 3 0 01 16 03 01 02 03 01 00 01 20 FF 1B Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data changes in the following order 1B t 2B t 00 Check the data is 00. (Note 2) Procedure Close the cassette compartment without inserting cassette.

Note 2: If the data is 01 or 11, adjustment has errors or the mechanism deck is defective. Also, if the data is 80, the mechanism deck is in emergency state or the tape reached its end.

DCR-HC47E/HC48/HC48E_ADJ 6-50

2.

Switching Position Adjustment (VC-472 board)

When the ODD channel is defective Data of page: C, address: 12 EE E8 E7 Contents of defect Writing intoEEP ROM (IC5302) is defective Adjustment data is out of range No data is returned from IC4201

RadarW
Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value VTR playback (PLAY/EDIT mode) SW/OL standard (XH2-3) Displayed data of page: 3, address: 03 Adjusting remote commander C 10, 11, 12, 13 The data of page: 3, address: 03 is 00

Note 1: Check that the data of page: 0, address: 10 is 00. Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 0 C 3 3 3 3 3 0 01 10 21 03 01 02 03 01 00 FF 0D 01 EE Press PAUSE (Write) button. Check the data is 02. (Note 2) Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data changes to 00. Check the data is 00. (Note 3) Procedure Insert the SW/OL standard tape and enter the VTR stop mode.

Note 2: If the data is 72, the tape top being played. After playing the tape for 1 to 2 seconds, stop it, perform step 5 and higher. If the data is 62, the tape end being played. After rewind the tape, perform step 5 and higher. Note 3: If bit0 of the data is 1, the EVEN channel is defective. If bit1 of the data is 1, the ODD channel is defective. Contents of the defect is see written into page: C, address: 10 and 12. See following table. (For the bit values, refer to 6-4. SERVICE MODE, 44. 3. Bit value discrimination.) If bit3 of the data is 1, the tape end being played, so rewind the tape and perform the adjustment again.

When the EVEN channel is defective Data of page: C, address: 10 EE E8 E7 Contents of defect Writing into EEPROM (IC5302) is defective Adjustment data is out of range No data is returned from IC4201

DCR-HC47E/HC48/HC48E_ADJ 6-51

3.

Error Rate Check (VC-472 board)

Adjusting method: Order Page Address Data 1 0 01 01 Check that the data of page: 1C, address: B3 to C8 is the initial value. (See Table 6-34) Playback the recorded signal at Preparations before adjustments. 3 3 3 3 03 01 02 03 FF 40 Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data changes to 00. Check the data is 00. (Note 2) Perform Processing after Completing Adjustments. Procedure

RadarW
Note: Check that the data of page: 0, address: 10 is 00. 3-1. Preparations before adjustments Mode Subject Camera recording (CAMERA-TAPE mode) Arbitrary

3 Adjusting method: Order Page Address Data 1 2 3 4 5 0 0 C 0 01 10 0D 10 01 01 C8 00 Record the camera signal for 2 minutes. Press PAUSE (Write) button. Procedure 4 5 6 7 8

3-2. Error Rate Check Mode Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value VTR playback (PLAY/EDIT mode) Recorded signal at Preparations before adjustments Displayed data of page: 3, address: 03 Adjusting remote commander 1C (Note 1) B3 to C8 The data of page: 3, address: 03 is 00

Note 2: If the data is other than 00, Error rate is abnormal. For the contents of the abnormality, see the following table. Data of page: 3, address: 03 01 02 03 Contents of defect EVEN channel is abnormal. ODD channel is abnormal. EVEN channel and ODD channel are abnormal.

Note 1: If reading/writing data on pages 1C, set data: 01 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 1C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to 00. Initial Value of Page 1C: Address: B3 to C8 Address B3 B4 B5 B6 B7 B8 B9 BA Initial value 00 00 00 00 00 80 00 00 Address BB BC BD BE BF C0 C1 C2 Initial value 00 00 00 00 00 00 00 00 Address C3 C4 C5 C6 C7 C8 Initial value 80 00 00 00 00 00

Note 3: If Error rate is abnormal, Check the use tape, clean the tape running surface. And after inputting initial values to page 1C: address: B3 to C8, perform re-adjustment. (See Table 6-3-4) Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 0 0 C 0 0 01 10 0D 10 01 01 01 00 00 00 Press PAUSE (Write) button. Procedure

Table 6-3-4

DCR-HC47E/HC48/HC48E_ADJ 6-52

3-4.

VIDEO SYSTEM ADJUSTMENTS

Before perform the video system adjustments, check that the specified values of 33MHz/27MHz Origin Oscillation check of 1-3. CAMERA SYSTEM ADJUSTMENTS is satisfied. Check that the data of page: 0, address: 10 is 00. If not, select page: 0, address: 10, and set the data 00. Adjusting Procedure: 1. IC4701 LINE OUT Y level adjustment 2. IC4701 LINE OUT chroma level adjustment 3. S VIDEO OUT Y lebel adjustment 4. S VIDEO OUT chroma adjustment 5. IC4701 Automatic adjustment 6. VIDEO OUT level check 1. IC4701 LINE OUT Y Level Adjustment (VC-472 board) CAMERA-TAPE Arbitrary Y signal terminal of S VIDEO plug of A/V OUT jack (75 terminated) Oscilloscope C 80 Y level: A = 1000 14 mVp-p Sync level: B = 286 6 mVp-p (NTSC) B = 300 6 mVp-p (PAL)

B H

Fig. 6-3-3

Mode Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value

Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) DEMO MODE (Menu setting) ........................................ OFF Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 3 8 0 01 4C 01 00 00 0 8 3 C C 01 4C 01 80 80 70 01 Set the bit value of bit1 is 0, and press PAUSE (Write) button. (Note 3) Press PAUSE (Write) button. Change the data and set the Y signal level (A) to the specified value. Press PAUSE (Write) button. Check the sync signal level (B) to the specified value. Press PAUSE (Write) button. Set the bit value of bit1 is 1, and press PAUSE (Write) button. (Note 3) Procedure

Note 3: For the bit values, refer to 6-4. SERVICE MODE, 44. 3. Bit value discrimination.

DCR-HC47E/HC48/HC48E_ADJ 6-53

2.

IC4701 LINE OUT Chroma Level Adjustment (VC-472 board) CAMERA-TAPE Arbitrary Chroma signal terminal of S VIDEO plug of A/V OUT jack (75 terminated) External trigger: Y signal terminal of S VIDEO plug of A/V OUT jack (75 terminated) Oscilloscope C 81, 82 Cr level: A = 714 14 mVp-p (NTSC) A = 715 14 mVp-p (PAL) Cb level: B = 714 14 mVp-p (NTSC) B = 715 14 mVp-p (PAL) Burst level: C = 286 6 mVp-p (NTSC) C = 300 6 mVp-p (PAL)
A

Mode Subject Measurement Point

Measuring Instrument Adjustment Page Adjustment Address Specified value

0.28 sec (NTSC) 0.23 sec (PAL)

0.28 sec (NTSC) 0.23 sec (PAL)

Fig. 6-3-4

Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) DEMO MODE (Menu setting) ........................................ OFF Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 3 8 0 01 4C 01 00 00 Set the bit value of bit1 is 1, and press PAUSE (Write) button. (Note 3) 0 8 3 C C C C 01 4C 01 81 81 82 82 70 01 Set the bit value of bit1 is 0, and press PAUSE (Write) button. (Note 3) Press PAUSE (Write) button. Change the data and set the Cr signal level (A) to the specified value. Press PAUSE (Write) button. Change the data and set the Cb signal level (B) to the specified value. Press PAUSE (Write) button. Check the burst signal (C) to the specified value. Procedure

Note 3: For the bit values, refer to 6-4. SERVICE MODE, 44. 3. Bit value discrimination.

DCR-HC47E/HC48/HC48E_ADJ 6-54

3.

S VIDEO OUT Y Level Adjustment (VC-472 board) CAMERA-TAPE Arbitrary Y signal terminal of S VIDEO plug of A/V OUT jack (75 terminated) Oscilloscope C 25 A = 1000 14 mVp-p

Mode Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value

Note 1: This adjustment should be carried out upon completion of the following adjustments. IC4701 LINE OUT Y Level Adjustment, IC4701 LINE OUT Chroma Level Adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Switch setting 1) DEMO MODE (Menu setting) ........................................ OFF Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 0 8 3 C C 3 8 0 01 4C 01 25 25 01 4C 01 00 00 71 01 Set the bit value of bit1 is 0, and press PAUSE (Write) button. (Note 3) Press PAUSE (Write) button. Change the data and set the Y signal level (A) to the specified value. Press PAUSE (Write) button. Press PAUSE (Write) button. Set the bit value of bit1 is 1, and press PAUSE (Write) button. (Note 3) Procedure

Note 3: For the bit values, refer to 6-4. SERVICE MODE, 44. 3. Bit value discrimination.

Fig. 6-3-5

DCR-HC47E/HC48/HC48E_ADJ 6-55

4.

S VIDEO OUT Chroma Level Adjustment (VC-472 board) CAMERA-TAPE Arbitrary Chroma signal terminal of S VIDEO plug of A/V OUT jack (75 terminated) External trigger: Y signal terminal of S VIDEO plug of A/V OUT jack (75 terminated) Oscilloscope C 26, 27 Cr level: A = 714 14 mVp-p (NTSC) A = 700 14 mVp-p (PAL) Cb level: B = 714 14 mVp-p (NTSC) B = 700 14 mVp-p (PAL) Burst level:C = 286 6 mVp-p (NTSC) C = 300 6 mVp-p (PAL)

Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 3 8 0 01 4C 01 00 00 0 8 3 C C C C 01 4C 01 26 26 27 27 71 01 Set the bit value of bit1 is 0, and press PAUSE (Write) button. (Note 4) Press PAUSE (Write) button. Change the data and set the Cr signal level (A) to the specified value. Press PAUSE (Write) button. Change the data and set the Cb signal level (B) to the specified value. Press PAUSE (Write) button. Check the burst signal (C) to the specified value. Press PAUSE (Write) button. Set the bit value of bit1 is 1, and press PAUSE (Write) button. (Note 4) Procedure

Mode Subject Measurement Point

Measuring Instrument Adjustment Page Adjustment Address Specified value

Note 1: This adjustment should be carried out upon completion of the following adjustments. IC4701 LINE OUT Y Level Adjustment, IC4701 LINE OUT Chroma Level Adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) DEMO MODE (Menu setting) ........................................ OFF

Note 4: For the bit values, refer to 6-4. SERVICE MODE, 44. 3. Bit value discrimination.
H

0.28 sec (NTSC) 0.23 sec (PAL)

0.28 sec (NTSC) 0.23 sec (PAL)

Fig. 6-3-6

DCR-HC47E/HC48/HC48E_ADJ 6-56

5. IC4701 Automatic Adjustment (VC-472 board) Adjust the IC4001 Y output level (IC4701 input Y level) when letting the IC4701 line system pass. And adjust the clamp level and output level of the IC4701 panel (LCD) system and output level of the IC4001. Mode Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value CAMERA-TAPE Arbitrary Display data of page: 3, address: 04, 05 Adjusting remote commander C 83 to 8A, 99, A1 to A3 Data of page: 3, address: 04 is 78 Data of page: 3, address: 05 is 78 Note 1: This adjustment should be carried out upon completion of the following adjustments. IC4701 LINE OUT Y Level Adjustment, IC4701 LINE OUT Chroma Level Adjustment, S VIDEO OUT Y Level Adjustment, S VIDEO OUT Chroma Level Adjustment. Note 2: Check that the data of page: 0, address: 10 is 00. Note 3: Connect the multi-cable and make a check with the panel lighting. Switch setting LCD panel ........................................................................... OPEN Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 0 3 3 3 3 3 3 01 03 01 04 05 03 01 00 01 FF 78 Press PAUSE (Write) button. Press PAUSE (Write) button. (Note 4) Check the data is 78. (Note 5) Check the data is 78. (Note 5) Check the data is 00. Press PAUSE (Write) button. Procedure

Processing after completing adjustment: Order Page Address Data 1 2 3 C C C A1 A2 A3 Procedure Read the data and this data is named DA1. Read the data and this data is named DA2. Read the data and this data is named DA3. Convert DA1, DA2 and DA3 into decimal digits, to obtain DA1, DA2 and DA3. (Note 6) Calculate D8A2, D8A3 and D8A4 using the following equations. (decimal calculation) D8A2 = DA1 (511/439) D8A3 = DA2 (511/439) D8A4 = DA3 (511/439) Convert D8A2, D8A3 and D8A4 to hexadecimal number, and obtain D8A2, D8A3 and D8A4. (Round off to one decimal place) (Note 6) 8 8 8 0 A2 A3 A4 01 D8A2 Press PAUSE (Write) button. D8A3 Press PAUSE (Write) button. D8A4 Press PAUSE (Write) button. 00

7 8 9 10

Note 6: Refer to table 6-4-1. Hexadecimal-decimal conversion table.

Note 4: The adjustment data will be automatically input to page: C, address: 83 to 8A, 99, A1 to A3. Note 5: If the data is other than 78, adjustment has errors. Contents of error is written into Page: 3, address: 03. See the following Table. Data of page: 3, address: 03 72 74 75 76

Contents fo error S VIDEO OUT Y level adjustment (IC4701 line on) error IC4701 Panel (LCD) Clamp level adjustment error IC4001 Panel (LCD) Output Gain adjustment error IC4701 Panel (LCD) Output Gain adjustment error

DCR-HC47E/HC48/HC48E_ADJ 6-57

6.

VIDEO OUT Level Check (VC-472 board) CAMERA-TAPE Arbitrary Video terminal of A/V OUT jack (75 terminated) Oscilloscope Sync level: A = 286 18 mVp-p (NTSC) A = 300 18 mVp-p (PAL) Burst level:B = 286 18 mVp-p (NTSC) B = 300 18 mVp-p (PAL)

Mode Subject Measurement Point Measuring Instrument Specified value

Note 1: Check that the data of page: 0, address: 10 is 00. Note 2: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Switch setting 1) DEMO MODE (Menu setting) ........................................ OFF Checking method: Order Page Address Data 1 2 3 4 3 01 00 3 01 71 Procedure Press PAUSE (Write) button. Check the sync signal level (A) to the specified value. Check the burst signal level (B) to the specified value. Press PAUSE (Write) button.

B A H

Fig. 6-3-7

DCR-HC47E/HC48/HC48E_ADJ 6-58

3-5.

AUDIO SYSTEM ADJUSTMENTS

1.

Playback Level Check Playback (PLAY/EDIT mode) Alignment tape: For audio operation check (XH5-3 (NTSC)) (XH5-3P (PAL)) Audio left or right terminal of A/V OUT jack Audio level meter and frequency counter 32 kHz mode: 1 kHz, + 3.0 2.0 dBs 48 kHz mode: 1 kHz, + 3.0 2.0 dBs 44.1 kHz mode: The 7.35 kHz signal level during EMP OFF is +2.0 2.0 dBs. The 7.35 kHz signal level during EMP ON is 6 2 dB from the signal level during EMP OFF.

[Connecting the measuring instruments for the audio] Connect the audio system measuring instruments in addition to the video system measuring instruments as shown in Fig. 6-3-8.

Mode Signal

In Recording (CAMERA-TAPE mode)


Pattern generator Video output (75 ) Audio oscillator Attenuator Video Main unit Audio (L) 600 Audio (R) A/V OUT jack

Measurement Point Measuring Instrument Specified Value

600 (270 (1-249-410-11) +330 (1-249-411-11))

Note: NTSC model: DCR-HC48 PAL model: DCR-HC47E/HC48E Checking Method: 1) Check that the playback signal level is the specified value.

In Playback (PLAY/EDIT mode)


Main unit Audio level meter or distortion meter

2.

Overall Level Characteristics Check Recording (CAMERA-TAPE) and playback (PLAY/EDIT mode) 400 Hz, 7.5 dBs signal: Audio left and right terminal of A/V OUT jack Audio left or right terminal of A/V OUT jack Audio level meter 7.5 3.0 dBs

Mode Signal

A/V OUT jack

Audio (L) Audio (R) 47 k 47 k : 1-249-437-11

Measurement Point Measuring Instrument Specified Value

TV monitor Video

Fig. 6-3-8

Checking Method: 1) Select page: 7, address: 01, and set data: 94. 2) Select page: 7, address: 04, and set data: 0E. 3) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 4) Select page: 7, address: 02, and check that the changes to 01. 5) Input the 400 Hz, 7.5 dBs signal in the audio left and right terminal of A/V OUT jack. 6) Record the signal. 7) Remove the input signal. 8) Playback the recorded section. 9) Check that the 400 Hz signal level is the specified value. 10) Select page: 7, address: 01, and set data: 94. 11) Select page: 7, address: 04, and set data: FF. 12) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 13) Select page: 7, address: 02, and check that the changes to 01.

DCR-HC47E/HC48/HC48E_ADJ 6-59

3.

Overall Distortion Check Recording (CAMERA-TAPE) and playback (PLAY/EDIT mode) 400 Hz, 7.5 dBs signal: Audio left and right terminal of A/V OUT jack Audio left or right terminal of A/V OUT jack Audio distortion meter Below 0.4% (200 Hz to 6 kHz BPF ON)

5.

Overall Separation Check Recording (CAMERA-TAPE) and playback (PLAY/EDIT mode) 400 Hz, 7.5 dBs signal: Audio <right> [left] terminal of A/V OUT jack No signal: Audio <left> [right] terminal of A/V OUT jack Audio <left> [right] terminal of A/V OUT jack Audio level meter Below 40 dBs

Mode Signal

Mode Signal

Measurement Point Measuring Instrument Specified Value

Measurement Point Measuring Instrument Specified Value < > : Left channel check [ ] : Right channel check

Checking Method: 1) Select page: 7, address: 01, and set data: 94 2) Select page: 7, address: 04, and set data: 0E. 3) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 4) Select page: 7, address: 02, and check that the changes to 01. 5) Input the 400 Hz, 7.5 dBs signal in the audio left and right terminal of A/V OUT jack. 6) Record the signal. 7) Remove the input signal. 8) Playback the recorded section. 9) Check that the distortion is the specified value. 10) Select page: 7, address: 01, and set data: 94. 11) Select page: 7, address: 04, and set data: FF. 12) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 13) Select page: 7, address: 02, and check that the change to 01. 4. Overall Noise Level Check Recording (CAMERA-TAPE) and playback (PLAY/EDIT mode) No signal: Audio left and right terminal of A/V OUT jack Audio left or right terminal of A/V OUT jack Audio level meter Below 45 dBs (IHF-A filter ON, 20 kHz LPF ON)

Mode Signal

Checking Method: 1) Select page: 7, address: 01, and set data: 94 2) Select page: 7, address: 04, and set data: 0E. 3) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 4) Select page: 7, address: 02, and check that the changes to 01. 5) Input the 400 Hz, 7.5 dBs signal in the audio <right> [left] terminal of A/V OUT jack. Connect the audio <left> [right] terminal of A/V OUT jack to GND using a jumper wire. 6) Record the signal. 7) Remove the input signal, and remove the jumper wire. 8) Playback the recorded section. 9) Check that the signal level of the audio <left> [right] terminal is the specified value. 10) Select page: 7, address: 01, and set data: 94. 11) Select page: 7, address: 04, and set data: FF. 12) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 13) Select page: 7, address: 02, and check that the change to 01.

Measurement Point Measuring Instrument Specified Value

Checking Method: 1) Select page: 7, address: 01, and set data: 94. 2) Select page: 7, address: 04, and set data: 0E. 3) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 4) Select page: 7, address: 02, and check that the change to 01. 5) Connect the audio left terminal of A/V OUT jack to GND using a jumper wire. Connect the audio right terminal of A/V OUT jack to GND using a jumper wire. 6) Record the signal. 7) Remove the jumper wires. 8) Playback the recorded section. 9) Check that the noise level is the specified value. 10) Select page: 7, address: 01, and set data: 94. 11) Select page: 7, address: 04, and set data: FF. 12) Select page: 7, address: 00, set data: 01, and press the PAUSE (Write) button. 13) Select page: 7, address: 02, and check that the change to 01.

DCR-HC47E/HC48/HC48E_ADJ 6-60

6-4. SERVICE MODE


4-1. ADJUSTMENT REMOTE COMMANDER (RM-95)

2.

The adjustment remote commander (RM-95) is used for changing the calculation coefficient in signal processing, EVR data, etc. The adjustment remote commander (RM-95) performs bi-directional communication with the unit using the remote commander signal line (LANC). The resultant data of this bi-directional communication is written in the non-volatile memory. 1. Using the Adjustment Remote Commander (RM-95) 1) Connect the adjustment remote commander to the LANC terminal. 2) Set the HOLD switch of the adjustment remote commander (RM-95) to HOLD (SERVICE position). If it has been properly connected, the LCD on the adjustment remote commander (RM-95) will display as shown in Fig. 6-4-1.

Precautions Upon Using the Adjustment Remote Commander (RM-95) Mishandling of the adjustment remote commander may erase the correct adjustment data at times. To prevent this, it is recommended that all adjustment data be noted down before beginning adjustments and new adjustment data after each adjustment.

Page

Data

Address

Fig. 6-4-1
3) Operate the adjustment remote commander (RM-95) as follows. Changing the page The page increases when the EDIT SEARCH+ button is pressed, and decreases when the EDIT SEARCH button is pressed. There are altogether 16 pages, from 0 to F. Hexadecimal notation LCD Display Decimal notation conversion value 0 1 2 3 4 5 6 7 8 9 AB CD E F 0 1 2 3 4 5 6 7 8 9 A b c d E F 0 1 2 3 4 5 6 7 8 9 1011 12 1314 15

Changing the address The address increases when the FF (M) button is pressed, and decreases when the REW (m) button is pressed. There are altogether 256 addresses, from 00 to FF. Changing the data (Data setting) The data increases when the PLAY (N) button is pressed, and decreases when the STOP (x) button is pressed. There are altogether 256 data, from 00 to FF. Writing the adjustment data The PAUSE button must be pressed to write the adjustment data in the nonvolatile memory. (The new adjusting data will not be recorded in the nonvolatile memory if this step is not performed) 4) After completing all adjustments, turn off the main power supply (8.4 V) once.

DCR-HC47E/HC48/HC48E_ADJ 6-61

4-2.

ADJUSTMENT REMOTE COMMANDER (NEW LANC JIG)

2.

The adjustment remote commander (New LANC Jig) is used for changing the calculation coefficient in signal processing, EVR data, etc. The adjustment remote commander (New LANC Jig) performs bi-directional communication with the unit using the remote commander signal line (LANC). The resultant data of this bi-directional communication is written in the non-volatile memory. 1. Using the Adjustment Remote Commander (New LANC Jig)) 1) Connect the adjustment remote commander (New LANC Jig) to the LANC terminal via the LANC cable (J-6082-442-A). 2) Set the slide switch of the adjustment remote commander (New LANC Jig) to SERVICE (SERVICE position). If it has been properly connected, the LCD on the adjustment remote commander (New LANC Jig) will display as shown in Fig. 6-4-2.

Precautions Upon Using the Adjustment Remote Commander (New LANC Jig) Mishandling of the adjustment remote commander (New LANC Jig) may erase the correct adjustment data at times. To prevent this, it is recommended that all adjustment data be noted down before beginning adjustments and new adjustment data after each adjustment.

p:00 a:00 d:00


Page Address Data

Fig. 6-4-2
3) Operate the adjustment remote commander (New LANC Jig) as follows. Changing the page The page increases when the Page+ (M) button is pressed, and decreases when the Page (m) button is pressed. Changing the address The address increases when the ADD+ (N) button is pressed, and decreases when the ADD (X) button is pressed. There are altogether 256 addresses, from 00 to FF. Changing the data (Data setting) The data increases when the Data+ button is pressed, and decreases when the Data button is pressed. There are altogether 256 data, from 00 to FF. Writing the adjustment data The Write (x) button must be pressed to write the adjustment data in the nonvolatile memory. (The new adjusting data will not be recorded in the nonvolatile memory if this step is not performed) 4) After completing all adjustments, turn off the main power supply (8.4 V) once.

DCR-HC47E/HC48/HC48E_ADJ 6-62

4-3.

DATA PROCESS

The calculation of the DDS display and the adjustment remote commander display data (hexadecimal notation) are required for obtaining the adjustment data of some adjustment items. In this case, after converting the hexadecimal notation to decimal notation, calculate and convert the result to hexadecimal notation, and use it as the adjustment data. Indicates the hexadecimal-decimal conversion table. Hexadecimal-decimal Conversion Table
Lower digit of hexadecimal Upper digit of hexadecimal

2
4 5 6 7 8 9 A (A) 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 250 B (b) 11 27 43 59 77 91 107 123 139 155 171 187 203 219 235 251 C (c) 12 28 44 60 76 92 108 124 140 156 172 188 204 220 236 252 D (d) 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 253 E (E) 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 254 F (F) 15 31 47 63 79 95 111 127 143 159 175 191 207 223 239 255

0 1 2 3 4 5 6 7 8 9 A (A)

0 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240

1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 241

2 18 34 50 66 82 98 114 130 146 162 178 194 210 226 242

3 19 35 51 67 83 99 115 131 147 163 179 195 211 227 243

4 20 36 52 68 84 100 116 132 148 164 180 196 212 228 244

5 21 37 53 69 85 101 117 133 149 165 181 197 213 229 245

6 22 38 54 70 86 102 118 134 150 166 182 198 214 230 246

7 23 39 55 71 87 103 119 135 151 167 183 199 215 231 247

8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 248

9 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249

B (b) C (c) D (d) E (E) F (F)

Note: The characters shown in the parenthesis ( ) shown the display on the adjustment remote commander. (Example) If the DDS display or the adjustment remote commander shows BD (bd); Because the upper digit of the adjustment number is B (b), and the lower digit is D (d), the meeting point 189 of 1 and 2 in the above table is the corresponding decimal number.

Table 6-4-1

DCR-HC47E/HC48/HC48E_ADJ 6-63

4-4.

SERVICE MODE

Note: Before performing the adjustment, check the data of page: 0, address: 10 is 00. If not, select page: 0, address: 00, and set data 00. 1. Setting the Test Mode Address 10 Function Normal Forced camera power ON (CAMERA-TAPE mode) Forced VTR power ON (PLAY/EDIT mode) Forced camera + VTR power ON Forced memory power ON (CAMERA-MEMORY mode)

2. Emergence Memory Address 2-1. Emergence Memory Address (Mechanism section) Page C Address F4 F6 Address F4 to FF Contents EMG code when first error occurs Upper: MSW code when shift starts when first error occurs Lower: MSW code when first error occurs Lower: MSW code to be moved when first error occurs EMG code when second error occurs Upper: MSW code when shift starts when second error occurs Lower: MSW code when second error occurs Lower: MSW code to be moved when second error occurs EMG code when last error occurs Upper: MSW code when shift starts when last error occurs Lower: MSW code when last error occurs Lower: MSW code to be moved when last error occurs

Page A Data 00 01 02 03 05

F7 F8 FA FB

Before setting the data , select page: 0, address: 01, and set data: 01. For page A, the data set will be recorded in the non-volatile memory by pressing the PAUSE (Write) button of the adjustment remote commander. In this case, take note that the test mode will not be exited even when the main power is turned off (8.4 Vdc). After completing adjustments/repairs, be sure to return the data of this address to 00, and press the PAUSE (Write) button of the adjustment remote commander. And select page: 0, address: 01, and set data: 00.

FC FE FF

When no error occurs in this unit, data 00 is written in the above addresses (F4 to FF). when first error occurs in the unit, the data corresponding to the error is written in the first emergency address (F4 to F7). In the same way, when the second error occurs, the data corresponding to the error is written in the second emergency address (F8 to FB). Finally, when the last error occurs, the data corresponding to the error is written in the last emergency address (FC to FF). Note: After completing adjustments, be sure to initialize the data of addresses F4 to FF to 00. Initializing method: Order Page Address Data 1 2 3 4 5 6 0 3 3 3 3 0 01 03 01 02 03 01 00 01 FF 37 Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data changes to 00. Check the data changes to 00. Procedure

DCR-HC47E/HC48/HC48E_ADJ 6-64

2-2. EMG Code (Emergency Code) Codes corresponding to the errors which occur are written in C page, addresses F4, F8 and FC . The type of error indicated by the code are shown in the following table. Code 00 10 11 22 23 24 30 40 42 No error Loading motor emergency during loading Loading motor emergency during unloading T reel emergency during normal rotation S reel emergency during normal rotation T reel emergency (Short circuit between S reel terminal and T reel terminal) FG emergency at the start up of the capstan FG emergency at the start up of the drum FG emergency during normal rotation of the drum Emergency Type

DCR-HC47E/HC48/HC48E_ADJ 6-65

2-3. MSW Code MSW when errors occur: Information on MSW (mode SW) when errors occur MSW when movement starts: Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved) MSW of target of movement: Information on target MSW of movement when the mechanism position is moved

Mechanical Position
UNLOAD
EJ BL
ULE BL LD1 (SR) BL LD2 (HL) BL
STOP BL

LOAD
R/P

A (MSB) B C D (LSB) (Fixed at 0)

Lock released Cassette compartment

DCR-HC47E/HC48/HC48E_ADJ 6-66

0 1 0 0 = 4

1 1 1 0 = E 0 1 1 0 = 6
Code 4 E 6 2 A 8 C 0 F

1 1 1 0 = E 0 0 1 0 = 2

Position EJ BL ULE LD1 (SR) LD2 (HL) STOP R/P NULL

1 1 1 0 = E

LS chassis movement section

Contents Position at which the cassette component lock is released, at the farthest unload side mechanically at which the mechanism can move no further in the UNLOAD direction. BLANK code, at the boundary between codes. EJECT completion position. when the cassette is ejected, the mechanism will stop at this position. Cassette IN standby. The guide will start protruding out as the mechanism moves towards the LOAD position. When prepraing TOP load processing or when DEW is detected, rolling up tape by T reel is preformed at this position. When prepraing TOP load processing or when DEW is detected, rolling up tape by S reel is preformed at this position. Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the brake is imposed on both reels. PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and the tension regulator is ON, the mechanism is operating at this position in modes in which normal images are shown. Code not existing in the MD. Default value. Status before finding any mechanism position.

1 1 1 0 = E 1 0 1 0 = A

1 1 1 0 = E 1 0 0 0 = 8

Pinch roller pressing

1 1 0 0 = C

3. Bit Value Discrimination Bit values must be discriminated using the display data of the adjustment remote commander for the following items. Us the table below to discriminate if the bit value is 1 or 0.
Display on the adjustment remote commander

Address Page bit3 to bit0 discrimination bit7 to bit4 discrimination (Example) If the remote commander display is 8E, bit value from bit 7 to bit 4 can be discriminated from the column A, and those from bit 3 to bit 0 from column B.

Display on the adjustment remote commander 0 1 2 3 4 5 6 7 A 8 9 A (A) B (b) C (C) D (d) E (E) B F (F )

bit3 or bit7 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

Bit values bit2 bit1 or or bit6 bit5 0 0 0 0 0 1 0 1 1 0 1 0 1 1 1 1 0 0 0 0 0 1 0 1 1 0 1 0 1 1 1 1

bit0 or bit4 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

4.

Jack Check (1) (Handycam Station) Address FC

Page 7

Note: Check that the data of page: 0, address: 10 is 00. Bit 0 Function CRADLE MULTI jack (CR-082 board CN501) When bit value = 1 Used When bit value = 0 Not used

Using method: 1) Select page: 7, address: FC. 2) By discriminating the bit value of display data, the state of jack can be discriminated. 5. Jack Check (2) Address FB

Page 7

Note: Check that the data of page: 0, address: 10 is 00. Bit 0 Function A/V OUT jack (AV-112 board CN402) When bit value = 1 Used When bit value = 0 Not used

Using method: 1) Select page: 7, address: FB. 2) By discriminating the bit value of display data, the state of jack can be discriminated.

DCR-HC47E/HC48/HC48E_ADJ 6-67

6.

Switch Check (1) Address 81

Page 2

Note: Check that the data of page: 0, address: 10 is 00. Bit 0 1 3 4 5 Function POWER (SS21200 block) MODE CHANGE (SS21200 block) EJECT (SS21200 block S001) CC DOWN (Mechanism chassis) DISP/BATT INFO (CF102 board S802) When bit value = 1 ON ON ON ON (DOWN) ON When bit value = 0 OFF OFF OFF OFF (UP) OFF

Using method: 1) Select page: 2, address: 81. 2) By discriminating the bit value of display data, the state of switch can be discriminated. 7. Switch Check (2) Address 6F

Page 3

Note: Check that the data of page: 0, address: 10 is 00. Bit 0 Function REC PROOF SW (Mechanism chassis) When bit value = 1 SAVE When bit value = 0 REC

Using method: 1) Select page: 3, address: 6F. 2) By discriminating the bit value of display data, the state of switch can be discriminated.

DCR-HC47E/HC48/HC48E_ADJ 6-68

8.

Switch Check (3) Address 65 to 6B

Page 7

Note: Check that the data of page: 0, address: 10 is 00. Using method: 1) Select page: 7, address: 65 to 6B. 2) By discriminating the display data, the pressed key can be discriminated.

Address 65 (KEY AD0) (IC5101 <C5 ) 66 (KEY AD1) (IC5101 <B3 ) 67 (KEY AD2) (IC5101 <B4 ) 68 (KEY AD3) (IC5101 <D2 ) 69 (KEY AD4) (IC5101 <E2 ) 6A (KEY AD5) (IC5101 <E1 ) 6B (KEY AD6) (IC5101 <C2 )

Data 00 to 10 REC START/STOP (SS21200 block) (S004) REC WIDE PANEL ZOOM W ZOOM T START/STOP (SB10600 block) SELECT REVERES (SB10600 block) (SB10600 block) (SB10600 block) (FP-386 flexible) (S002) (S003) (S001) (S004) (S101) PHOTO (REC) (SS21200 block) (S003) PANEL EASY BACK LIGHT CLOSE (CF-102 board) (CF-102 board) (CF-102 board) (S803) (S805) (S804) PHOTO (FREEZE) (SS21200 block) (S005) 11 to 32 33 to 56 57 to 79 7A to 9D 9E to C0 C1 to E9 EA to FF No key input

PANEL NORMAL (FP-386 flexible) (S101) No key input

PANEL OPEN (CF-102 board) (S804)

DCR-HC47E/HC48/HC48E_ADJ 6-69

9.

LED, IR Light Check Address 00, 01 and 04

Page 7

Note: Check that the data of page: 0, address: 10 is 00. Using method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 7 7 7 7 7 01 04 00 00 01 90 00 01 00 00 Press PAUSE (Write) button. 7 7 7 01 04 00 90 01 01 Press PAUSE (Write) button. Check that the all LED are lit, and that the IR light is lit. Procedure Set the unit to CAMERATAPE mode.

DCR-HC47E/HC48/HC48E_ADJ 6-70

10. Record of Use Check (1) Page 7 Address A4 to AF

Note 1: This data will not be erased (reset) when the lithium 3 V power supply (CF-102 board BT901) is removed. Note 2: When the drum was replaced, initialize the drum rotation counted time. Note 3: Check that the data of page: 0, address: 10 is 00. Address A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF (BCD code) (BCD code) Tape run time (BCD code) Drum rotation counted time time Function Power supplying Hour (H) Hour (M) Hour (L) Minute Hour (H) Hour (M) Hour (L) Minute Hour (H) Hour (M) Hour (L) Minute 100000th place digit and 10000th place digit of counted time (decimal digit) 1000th place digit and 100th place digit of counted time (decimal digit) 10th place digit and 1st place digit of counted time (decimal digit) 100000th place digit and 10000th place digit of counted time (decimal digit) 1000th place digit and 100th place digit of counted time (decimal digit) 10th place digit and 1st place digit of counted time (decimal digit) Remarks 100000th place digit and 10000th place digit of counted time (decimal digit) 1000th place digit and 100th place digit of counted time (decimal digit) 10th place digit and 1st place digit of counted time (decimal digit)

Using method: 1) The record of use data is displayed at page: 7, addresses: A4 to AF. Initializing method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 12 7 7 7 7 7 7 7 7 7 7 7 7 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF 00 00 00 00 00 00 00 00 00 00 00 00 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button.

DCR-HC47E/HC48/HC48E_ADJ 6-71

11. Record of Use Check (2) Page 7 Address 90 to 95

Note 1: This data will not be erased (reset) when the lithium 3 V power supply (CF-102 board BT901) is removed. Note 2: When the drum was replaced, initialize the drum rotation counted time. Note 3: Check that the data of page: 0, address: 10 is 00. Address 90 91 92 93 94 95 (BCD code) Eject count without tape (BCD code) Function Eject count with tape Count (H) Count (M) Count (L) Count (H) Count (M) Count (L) Remarks 100000th place digit and 10000th place digit of Eject count (decimal digit) 1000th place digit and 100th place digit of Eject count (decimal digit) 10th place digit and 1st place digit of Eject count (decimal digit) 100000th place digit and 10000th place digit of Eject count (decimal digit) 1000th place digit and 100th place digit of Eject count (decimal digit) 10th place digit and 1st place digit of Eject count (decimal digit)

Using method: 1) The record of use data is displayed at page: 7, addresses: 90 to 95. Initializing method: Order Page Address Data 1 2 3 4 5 6 7 7 7 7 7 7 90 91 92 93 94 95 00 00 00 00 00 00 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button. Press PAUSE (Write) button.

12. Record of Use Check (3) Page 7 Address C8 to CD

Note 1: This data will not be erased (reset) when the lithium 3 V power supply (CF-102 board BT901) is removed. Note 2: Check that the data of page: 0, address 10 is 00. Address C8 C9 CA CB CC CD on date (BCD code) Final condensation occurrence date (BCD code) Function User initial power Year Month Day Year Month Day After setting the clock, set the date of power on next Remarks

Using method: 1) The record of use data is displayed at page: 7, addresses: C8 to CD.

DCR-HC47E/HC48/HC48E_ADJ 6-72

13. Record of Self-diagnosis Check Page 7 Address B0 to C6

Initializing method: Order Page Address Data 1 2 3 4 5 7 7 7 7 7 01 00 B0 to C6 00 01 00 00 C0 01 Press PAUSE (Write) button. Check that the data is 00. Procedure

Note 1: This data will not be erased (reset) when the lithium 3 V power supply (CF-102 board BT901) is removed. Note 2: Check that the data of page: 0, address 10 is 00. Address B0 B1 B2 B4 B5 B6 B8 B9 BA BC BD BE C0 C1 C2 C4 C5 C6 Self-diagnosis code Repaired by code (Occurred 1st time) *1 Block function code (Occurred 1st time) Detailed code (Occurred 1st time) Repaired by code (Occurred 2nd time) *1 Block function code (Occurred 2nd time) Detailed code (Occurred 2nd time) Repaired by code (Occurred 3rd time) *1 Block function code (Occurred 3rd time) Detailed code (Occurred 3rd time) Repaired by code (Occurred 4th time) *1 Block function code (Occurred 4th time) Detailed code (Occurred 4th time) Repaired by code (Occurred 5th time) *1 Block function code (Occurred 5th time) Detailed code (Occurred 5th time) Repaired by code (Occurred the last time) *1 Block function code (Occurred the last time) Detailed code (Occurred the last time) *1 : 01 t C, 03 t E Using method: 1) The past self-diagnosis codes are displayed at page: 7, address: BC to C6. Refer to 1-5. SELF-DIAGNOSIS FUNCTION of SERVICE MANUAL, LEVEL 2 for detail of the self-diagnosis code.

DCR-HC47E/HC48/HC48E_ADJ 6-73

FOR CAMERA COLOR REPRODUCTION ADJUSTMENT


Take a copy of CAMERA COLOR REPRODUCTION FRAME with a clear sheet for use.

For NTSC model

R-Y MG R

YE B-Y B

G CY

DCR-HC48

DCR-HC47E/HC48/HC48E_ADJ 6-74E 6-74

For PAL model

R-Y

MG

YE B-Y

B G CY

DCR-HC47E/HC48E

Reverse

985217051.pdf

Revision History
Ver. 1.0 Date 2006.12 History Official Release Contents S.M. Rev. issued

DCR-HC47E/HC48/HC48E_ADJ

Вам также может понравиться