Вы находитесь на странице: 1из 16

www.lgeaircon.

com
For continual product development, LG reserves the right to change specifications without notice. LG Electronics Inc. Printed in Korea 2011

LG Electronics Air Conditioning & Energy Solution 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone: 82-2-3777-7613 http://www.lgeaircon.com

N AT U R A L
Catalogue 2011

H E AT I N G

M A C H I N E

Specifications, design and feature in this catalogue are subject to change without prior notice.

EU-CA110

LG Electronics

Eco-friendly Technology
LG Electronics environmental policy is centered on its Lifes Good When its Green program. The program is divided into two areas: pre-production and post-production. LG Electronics goal is to reduce greenhouse gases in the pre- and post-production stages by 150,000 tons and 30,000,000 tons, respectively, by 2020. This reduction of greenhouse gases emitted during a products life cycle (including raw materials used in production, product distribution, product usage, and product disposal) will be carried out in stages.

Nature..... Human..... Comfort.....

ThErma v LinE up WhaT is ThErma v?


-The solution for new housing and renovation

04 06 08

BEnEfiTs of ThErma v
- Energy performance - respecting the Environment - Convenient Control - anti-Corrosion Gold fin - Easy installation - Constant heating - v2 injection

ThErma v spLiT _ hydrokiT (1, 3) ThErma v spLiT _ ouTdoor uniT (1 230v) ThErma v spLiT _ ouTdoor uniT (3 400v) ThErma v v2 injECTion ThErma v mono _ ouTdoor uniT (1 230v) ThErma v mono _ ouTdoor uniT (3 400v) ThErma v indoor Box for 3 mono ThErma v saniTary WaTEr Tank fLExiBLE appLiCaTion

14 16 18 20 22 24 26 28 30

LINE-UP
THERMA V Split Type (R410A) _ 1 230V / 3 400V
Capacity _ kW 9.0 12.0 14.0 16.0

LG Innovation Natural Heating Machine


THERMA V, Natural Heating Machine, Aiming at all-in-one Solution
Economical : According to its innovative technology and advanced performance efficiency,
THERMA V offers one of the highest cost-saving and payback with any heating system in the market!

Split (R410A)
1 1 / 3 1 / 3 1 / 3

Flexible : A solution that is easy to install and does not require constant house renovations. Natural : THERMA V respects the environment by using two renewable energy sources, the air and
the sun, and by reducing CO2 emissions.

THERMA V Split V2 Injection Type (R410A) _ 1 230V / 3 400V


Capacity _ kW 12.0 14.0

Government Subsidy : According to recent trends, the adoption of renewable energy, the heat pumps may enable consumers to obtain a government subisidy under certain conditions.

Split V2 Injection (R410A)


1 / 3
* Split V2 Injection available from August in the market

1 / 3

THERMA V MONO Type (R407C) _ 1 230V / 3 400V


Capacity _ kW 10.0 12.0 14.0

MONO (R407C)
1 / 3

SANITARY TANK
Volume_Liter Single Coil, 200 liter Single Coil, 300 liter Double Coil, 200 liter Double Coil, 300 liter

Sanitary Water Tank

What is ThErmA V?
A Natural Solution
Economical system with advanced Coefficient of Performance : COP = 4.5 Utilization of two renewable energies: Air and sun. Reduced CO2 emissions compared to gas or fuel heating.

The Solution for New Housing and Renovation


THERMA V is specially conceived to respond to the needs of the renovation market (to relieve or replace a boiler) and the new housing market. The product adapts perfectly to individual and collective residential applications. Moreover, this Air-to-Water heat pump makes up an eco-friendly product that uses two renewable energy sources the air and the sun. Finally, it proves economics with Coefficient of Performance (COP) up to 4.5, among the most advanced on the market.

A Flexible Solution
Monovalent operation : ThErma v is capable of responding to all of your daily comfort & energy needs. in addition, if the outdoor temperature decreases below the seasonal temperature, a backup electric heater will come to guarantee your optimal well-being.

Application : Replacing Coventional Boiler


ThErmA V hydrokit

Split
refrigerant Sanitary Water Tank

Backup Electric heater Water hydro kit

radiator

reversible heat pump

option : sanitary Water Tank

radiator underfloor heating

monobloc
Solar Panel reversible heat pump

Backup Electric heater Water radiator underfloor heating option : sanitary Water Tank

Alternative Bivalent Operation : ThErma v heat pump can also be integrated in the installation of existing boiler(gas or fuel). Boiler takes over space heating and sanitary hot water, in case of severe low ambient temperature.
room thermostat

Application : Using Existing Boiler

Split
refrigerant

Backup Electric heater Water hydro kit

Underfloor heating

ThErmA V Outdoor Unit

reversible heat pump

Boiler option : sanitary Water Tank

radiator underfloor heating

different heat transmitters : > underfloor heating > radiators (Low Temperature radiators) > fan Coil units

optional accessories : > sanitary Water Tank

monobloc
Water reversible heat pump radiator underfloor heating Boiler option : sanitary Water Tank

LG Air Conditioners 2011

06 /

07

benefits of ThErmA V

Energy Performance
COP COP

Respecting the Environment


Reducing CO2 Emissions
4.44 4.20
ANNUAL CO2 EMISSION

Advanced Coefficient of Performance (COP) for More Energy Saving 4.49 4.49
As generating energy from outdoor air even in low 4.20 temperature, THERMA V makes4.09 it 4.09 possible to heat 4.20 efficiently. With inverter technology of LG, THERMA V can make higher efficiency level up to the range of 4.1 to 4.5. In other words, consuming 1kW of electric energy of an 0,8~0,9 0,8~0,9 electrical network enables more than 4kW of heating energy.
Other Heating Systems Other Heating Systems
(Electrical Convector/Boiler) (Electrical Convector/Boiler)

4.44 4.44

4.49 4.09

The THERMA V solution by LG adopts two renewable energies, the air and the sun. This eco-friendly system will decrease CO2 emissions from heating systems on fossil energies such as gas and fuel.

COP

0,8~0,9 Other Heating Systems


(Electrical Convector/Boiler)

4,563kg

(kg / year)

38%
2,839kg

Outdoor AirAir Outdoor 75% of of 75% Free Energy Free Energy

THERMA V V THERMA Heat Pump Heat Pump

Heating Heating Hot Water Hot Water

Fuel/Gas Boiler Fuel/Gas Boiler


Outdoor Air
Fuel/Gas Fuel/Gas

Fuel/Gas Boiler Fuel/Gas Boiler NO NO CO2 2 CO


THERMA V Heat Pump
90% 90%

Heating Hot Water

Fuel/Gas Boiler
Fuel/Gas

Fuel/Gas Boiler NO CO2

Gas Boiler

Solar Panels

THERMA V

Source : Eurelectric

100% 100% 25% 25%

Electrical Convector Electrical Convector


25% 100%

100% 100% 75% of Free Energy

100% Electrical Convector

90%

100% 100%

100% 100%

100%

100%

Other Heating Systems (Electrical Convector/Boiler) Other Heating Systems (Electrical Convector/Boiler)

Other Heating Systems (Electrical Convector/Boiler)

Inverter regulation, for more serenity


Once the desired temperature is achieved, unlike conventional air to water heat pump that turns the compressor on and off, LG inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised.

LG Air Conditioners 2011

08 /

09

benefits of ThErmA V

Convenient Control
Control of the generation of heating, hot water - Weekly scheduling - Operating modes - Water temperature - Heating emergency operation

Easy Installation
Hydrokit

Separated Shut-off valves

integrated Grips
THERMA V Outdoor Unit THERMA V Hydro Kit Sanitary Hot Water Tank

Heating Emergency Operation


Heating is essential during winter. THERMA V is equipped with an emergency operation that allows the maintenance of heating in case of possible failure. The heating security mode consist of two levels the indoor: Level 1 : When the indoor unit slightly malfunctions, the outdoor unit operates under a pre-defined emergency operation mode. Level 2 : When outdoor unit malfunctions, electronic heater of the indoor unit operates under a pre-defined emergency operation mode.

Outdoor Unit
Facilitated maintenance - refrigerating connection is possible in three directions - access to vital parts of the machine thanks to the new removable front panel fixed with three screws.

Anti-Corrosion Gold Fin


The exchangers of our outdoor unit are treated against corrosion and pollution. This treatment guarantees the durability of the systems and high-level performance.

1 Direction Jacking-up Grips

3 Direction

- Easy to manipulate thanks to the integrated grips

> Salt Spray Test for 15 Days


LG Gold Fin Protected Alumium After 15 days LG Gold Fin Corrosion Resistance After 15 days Conventional Starting to Corrode Uncoated Alumium
Easy access to compressor 3 fixation screws

LG Air Conditioners 2011

10 /

11

benefits of ThErmA V
V2 Injection technology adopted by THERMA V Split offers you most comfortable atmosphere in extreme cold weather condition by providing 100% heating performance at -15C without an auxiliary heater or boiler. Therefore, it saves users electricity cost greatly (Peak data result with heating steady-state without defrost effect at the test condition of A*/W35)

Split V2 Injection : Logic - Functioning


Heating capacity Increase - V2 Injection Rotary compressor Cycle Diagram

100% performance at -15C without electric heaters

A Compelling reason to Use lG V2 injection

100% stable & constant heating down to -15C (THERMA V provides 100% comfort at any condition even down to -15C without an auxiliary heater) 75% heating performance at -20C
Heat exchanger

Water Inlet

EEV2

Save electricity consumption and save electricity bill

Eco-friendly

inverter technology offers ultimate comfortable environment

EEV3

EEV1

2 Stage Rotary Comp. Water Outlet Phase Separator

Constant Heating - V2 Injection Technology


Effects of V2 Injection technology
Expansion of THERMA V operating range
LG V2 injection (14kw)

Heating capacity increase

LG conducted a real field test in Norway to secure reliability at severe low temperatures.

100%

75%

50% -20

-15

-5

10
Normal AWHP LG

Outdoor Temperature

Heating Capacity @A-15 / W35

LG Air Conditioners 2011

12 /

13

Hydrokit (1, 3)

THERMA V Split hydrokit

HYDROKIT
HN0916. NK1 HN0926. NK1 HN0936. NK1 HN0914. NK1 Up to 9kW

HN1616. NK1 HN1626. NK1 HN1636. NK1 HN1629. NK1 Up to 16kW

Specifications
Hydrokit _ Indoor Unit
Combined Outdoor Unit

HN1639. NK1

*HN0916. *HN0926. *HN0936. HN0914. HN1616. HN1626. HN1636. *HN1629. HN1639.


NK1 NK1 NK1 NK1 NK1 NK1 NK1 NK1 NK1

474 490 313.2


14

305
13

HU121.U31 - 1 230V HU141.U31 - 1 230V HU161.U31 - 1 230V HU091.U41 - 1 230V HU123.U31 - 3 400V HU143.U31 - 3 400V HU163.U31 - 3 400V
Electric Heater Heater Dimension Weight Noise Level at 1 meter Leaving Water Temperature Water Pump Heating Cooling Max. Power Input Minimum Water Flow Rate Max. Head Expansion Tank * available from june of 2011 Power Supply Capacity W*H*D /V/Hz kW mm kg dB(A) C C Watt LPM
1/220-240V/50Hz 3/220V/50Hz 6 3/380-415V/50Hz 1/220-240V/50Hz 1/220~240V/50Hz 4 3/220V/50Hz 6

HUV121.U31 - 1 230V HUV141.U31 - 1 230V HUV141.U31 - 1 230V HUV123.U31 - 3 400V HUV143.U31 - 3 400V HU121.U31 - 1 230V
3/220V/50Hz 9 3/380-415V/50Hz

8
9

10

8
15

850

848

7
18 11 12

3/380-415V/50Hz

6 5

490*850*313 52 28 15~55 6~30 135 15 6.4 8

490*850*313 55 28 15~55 6~30 205 15 7 8


N 1 2 3 4 5 6 7 8 8 9 ITEM Refrigerating Pipe - Gas Refrigerating Pipe - Liquid Water Connection Entry 1 inch Water Connection Exit 1 inch Control Panel Water Pump Discharge Gate Open when pressed > 3 bars Thermal switch Thermal switch Control Box N 10 11 12 13 14 15 16 17 18 ITEM Flow Switch Plate Heat Exchanger Pressure Gage Expansion Tank Air-vent Electric Heater Strainer Shut-off Valve Carrying handle
1 2
17

17

meter liter

Separated Shut-off valves

LG Air Conditioners 2011

14 /

15

Outdoor Unit (1 230V) Maximum 55C Water Temperature

THERMA V Split _ 1

OUTDOOR UNIT
HU091. U41 9kW

3 4

N
834

ITEM Liquid side service valve(mm) Gas side service valve(mm) Air discharge grill Control Cover

1
364 56 48 48 56 4817 88 61 81565231

2 3
150

158 24 81 68

Specifications
Outdoor Unit
Combined Hydrokit

165

620 620

93 165 165

74

27

390

80 42

HU091. U41

HU121. U31

HU141. U31

HU161. U31

24

165

HN0916. NK1 HN0926. NK1 HN0936. NK1 HN0914. NK1

HN1616. NK1 HN1626. NK1 HN1636. NK1 HN1629. NK1 HN1639. NK1

392 358 330

4 Holes for anchor bolts

OUTDOOR UNIT
HU121. U31 12kW 14kW 16kW HU141. U31 HU161. U31

Power Supply Nominal Capacity Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Cooling(A35/W18) Nominal Input Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Cooling(A35/W18) COP Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) EER Sound pressure level Dimension Weight Refrigerant (R410A) Pre-charged amount Cooling(A35/W18) Heating Cooling W*H*D

/ V / Hz kW kW kW kW kW kW kW kW kW kW W/W W/W W/W W/W W/W dBA dBA mm kg g 9.71 9 6.87 8.61 9.00 2.2 2.2 2.07 3.19 2.65 4.41 4.09 3.32 2.70 3.40 52 52 950*834*330 64 1,900 13.32 12 9.4 11.48 14.00 2.99 2.67 2.8 4.16 4.40 4.45 4.49 3.36 2.76 3.18

1 / 220-240V / 50Hz 14.94 14 10.69 13.11 14.00 3.39 3.15 3.22 4.85 4.40 4.41 4.44 3.32 2.70 3.18 53 54 950*1,380*330 16.93 16 11.9 14.8 14.00 3.87 3.81 3.62 5.61 4.40 4.37 4.20 3.29 2.64 3.18

30

Supporter

1380

N 1
56 490 48 56 48 18 74 52 31 150

ITEM Liquid side service valve(mm) Gas side service valve(mm) Air discharge grill Control Cover

2 3 4

93 950

26

73

20 115 138

23 134 18 68

24

72 80

390

80 42

165

620

165 30

404

361

2,980 3/8, 5/8


4 Holes for anchor bolts

Pipe Diameter(Liquid/Gas) inch

330

105

LG Air Conditioners 2011

16 /

17

Outdoor Unit (3 400V) Maximum 55C Water Temperature

THERMA V Split _ 3

OUTDOOR UNIT
HU123. U31 HU143. U31 HU163. U31 12kW 14kW 16kW

Supporter

Specifications
Outdoor Unit
Combined Hydrokit

HU123. U31

HU143. U31

HU163. U31
1380

93 950

26

73

20 115 138

23 134 18 68

24

72 80

390

80 42

Power Supply Nominal Capacity Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Cooling(A35/W18) Nominal Input Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Cooling(A35/W18) COP Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) EER Sound pressure level Dimension Weight Refrigerant (R410A) Pre-charged amont Cooling(A35/W18) Heating Cooling W*H*D

/ V / Hz kW kW kW kW kW kW kW kW kW kW W/W W/W W/W W/W W/W dBA dBA mm kg g 13.25 12 9.46 11.66 14.60 3.02 2.72 2.83 4.31 4.02 4.39 4.41 3.34 2.71 3.63

3 / 380-415V / 50Hz 15.06 14 10.89 12.72 15.50 3.49 3.24 3.28 4.98 4.65 4.32 4.32 3.32 2.55 3.33 53 54 950*1,380*330 105 2,980 3/8, 5/8 17.34 16
404 361 330

165

620

165 30

12.22 14.92 16.80 4.1 3.81 3.82 5.95 5.09 4.23 4.20 3.20 2.51 3.30

4 Holes for anchor bolts

N 1 2 3 4

ITEM Liquid side service valve(mm) Gas side service valve(mm) Air discharge grill Control Cover

Pipe Diameter(Liquid/Gas) inch

18 74 52 31 150

HN1616. NK1 HN1626. NK1 HN1636. NK1 HN1629. NK1 HN1639. NK1

56

490

48 56 48

LG Air Conditioners 2011

18 /

19

Outdoor Unit (1 230V) Maximum 55C Water Temperature

THERMA V V2 injection 1, 3

OUTDOOR UNIT
HUV121. U31 HUV141. U31 HUV123. U31 HUV143. U31 12kW 14kW 12kW 14kW

4-holes for anchor bolts

390

360

Specifications
Outdoor Unit
Combined Hydrokit

HUV121. U31

HUV141. U31

HUV123. U31

HUV143. U31

HN1616.NK1 HN1626.NK1 HN1636.NK1 HN1629.NK1 HN1639.NK1

330

Supporter

1,380

Power Supply Nominal Capacity Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-2/W35) Cooling(A35/W18) Nominal Input Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-2/W35) Cooling(A35/W18) COP Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-2/W35) EER Peak Data at A-15/W35 (*) Sound pressure level Dimension Weight(Net) Refrigerant (R410A) Pre-charged amont Cooling(A35/W18) Heating Capacity COP Heating Cooling W*H*D

/ V / Hz kW kW kW kW kW kW kW kW kW kW W/W W/W W/W W/W W/W kW W/W dBA dBA mm kg g 13.10 12.00 9.85 12.11 12.00 3.05 2.82 3.14 5.16 3.33 4.30 4.26 3.14 2.35 3.60 12.28 2.32

1 / 220-240V / 50Hz 14.69 14.00 11.05 13.58 14.00 3.34 3.32 3.44 5.71 3.88 4.40 4.22 3.21 2.38 3.61 13.78 2.35 54 53 950*1,380*330 105 3,400 (3/8)/(5/8) 13.10 12.00 9.85 12.11 12.00 3.05 2.82 3.14 5.16 3.33 4.30 4.26 3.14 2.35 3.60 12.28 2.32

3 / 380-415V / 50Hz 14.69 14.00

13.58 14.00 3.34 3.32 3.44 5.71 3.88 4.40 4.22 3.21 2.38 3.61 13.78 2.35
N 1 2 3 4 ITEM Liquid side service valve(mm) Gas side service valve(mm) Air discharge grill Control Cover
165 620 950 165 400

Pipe Diameter(Liquid/Gas) inch

Available from August (*) : Heating steady-state performance without defrost effect

490

11.05

1,356

LG Air Conditioners 2011

20 /

21

Outdoor Unit (1 230V) Maximum 60C Water Temperature

THERMA V mono _ 1

OUTDOOR UNIT
HM091M. U31 HM121M. U31 HM141M. U31 9kW 12kW 14kW

165

620

3 13 1

165 50 40

13

150 218

30

2 4

Specifications
Outdoor Unit
Power Supply Nominal Capacity Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Cooling(A35/W18) Nominal Input Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Cooling(A35/W18) COP Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) EER Sound pressure level Dimension Weight Refrigerant(R407C) Pre-charged amount Leaving Water Temperature Water Pump Heating Cooling Maximum Power Input Maximum Head Cooling(A35/W18) Heating Cooling W*H*D / V / Hz kW kW kW kW kW kW kW kW kW kW W/W W/W W/W W/W W/W dBA dBA mm kg g C C W m 10.58 10 5.67 7.40 10.00 2.39 2.35 2.19 3.02 2.74 4.43 4.26 2.59 2.45 3.65 53 53

404 361 330

HM091M. U31

HM121M. U31
1 / 220-240V / 50Hz 12.7 12 6.83 9.0 12.00 2.91 2.86 2.57 3.62 3.33 4.36 4.20 2.66 2.49 3.60 53 53 950*1,380*330 131 3,550 20~65 6~25 205 7 12

HM141M. U31
14.68 14 8.57 11.05
1380 1356

4 Holes for anchor bolts

14.00 3.43 3.38 2.99 4.23 4.01 4.28 4.14 2.87 2.61 3.49 54 54

6 7

8 9 10

12
165 620 950 165

11

N 1 2 3 4 5 6 7 8 9 10

ITEM Energy Water Pipe Leaving Water Pipe Strainer Top Cover Control Box Plate Heat Exchanger Water Pump Pressure Gage Safety Valve Compressor

Minimum Water Flow Rate LPM

LG Air Conditioners 2011

22 /23

Outdoor Unit (3 400V) Maximum 60C Water Temperature

THERMA V mono _ 3

OUTDOOR UNIT
HM103M. U31 HM123M. U31 HM143M. U31 10kW 12kW 14kW

165

620

3 12 1

165 50 40

12

150 218

30

2 4

Specifications
Outdoor Unit
Power Supply Nominal Capacity Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Nominal Input Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) COP Heating(A10/W35) Heating(A7/W35) Heating(A2/W35) Heating(A-7/W35) Sound pressure level Dimension Weight Refrigerant(R407C) Leaving Water Temperature Heating Heating / V / Hz kW kW kW kW kW kW kW kW W/W W/W W/W W/W dBA W*H*D kg g C 10.79 10.00 7.36 9.29 2.45 2.35 2.59 3.37 4.40 4.26 2.84 2.76 53

404 361 330

HM103M. U31

HM123M. U31
3 / 380-415V / 50Hz 12.70 12.00 8.04 10.83 2.90 2.86 2.83 4.01 4.38 4.20 2.84 2.70 53 950*1,380*330 128 3,550 20~65

HM143M. U31
14.81 14.00 8.45 11.65
1380 1356

4 Holes for anchor bolts

3.40 3.38 3.06 4.42 4.36 4.14 2.76 2.64 53

7 8 9 11
165 620 950 165

10

N 1 2 3 4 5 6 7 8 9

ITEM Energy Water Pipe Leaving Water Pipe Strainer Top Cover Control Box Plate Heat Exchanger Pressure Gauge Safety Valve Compressor

LG Air Conditioners 2011

24 /

25

An Indoor Box for MONOBLOC 3

THERMA V indoor box


The indoor box contains an electric backup heater and a water pump.
The traditional monoBLoC includes an electric back-up heater and a water pump in the outside unit. LGs 3-phase monoBLoC puts the water pump in the indoor box so that it keeps the water pump from being frozen as it is installed inside the building separately. it also generates additional heat energy with an electric back-up heater.

Specifications
Outdoor Unit
Electric Heater Power Supply Capacity Water Pump Maximum Power Input Maximum Head /V/Hz Kw W m

CHN1426. NK1
3 / 220V / 50Hz 6 205 7 15 490*850*315 38 25 / 25 3

CHN1436. NK1
3 / 380-415V / 50Hz 6 205 7 15 490*850*315 38 25 / 25 3

CHN1429. NK1
3 / 220V / 50Hz 9 205 7 15 490*850*315 38 25 / 25 3

CHN1439. NK1
3 / 380-415V / 50Hz 9 205 7 15 490*850*315 38 25 / 25 3

Minimum Water Flow Rate(LPM) Dimension Weight Water Connections Entry / Leaving Safety Valve Relief Pressure W*H*D mm kg mm Bar

INDOOR BOx
474 305

N
9 7

ITEM Energy Water Pipe Leaving Water Pipe Control Panel Water Pump Safety Valve Thermal Switch Control Box Pressure Gage Air Vent Electronic Heater Strainer Shut-off Valve Carrying Handle

1 2 3

10

4 5 6

848

13

7 8

8 4 3

9 10 11 12 13

12 11

12

66

52 266 474 100 75.1

39

N AT U R A L

H E AT I N G

M A C H I N E

LG Air Conditioners 2011

26 /

27

THERMA V Sanitary Water


saniTary WaTEr Tank sinGLE CoiL
SANITARy WATER TANK
GENERAL CHARACTERISTICS Water Volume Diameter Height Empty Weight Tank Materials Outer Skin Materials Color White RAL CHARACTERISTICS OF ELECTRICAL BACK-UP Additional Electric Heater Adjustable Thermostat CHARACTERISTICS OF ExCHANGER Exchanger Type Material Exchanger Maximum Water Temperature HyDRAULIC CONNECTIONS HEAT PUMP THERMA V Entry THERMA V Exit HyDRAULIC CONNECTIONS SANITARy WATER City Water Entry Hot water Exit ELECTRIC CONNECTION Supply L mm mm kg

SANITARY WATER TANK SINGLE COIL


LGRTV200E LGRTV300E 198 LITERS 287 LITERS

LGRTV200E
198 580 1230 45 Stainless steel Paint Epoxy White NC 3 60 ~ 90 Single LDx 2101 Stainless steel 80 25 25 22 22 1/220-240V 50Hz

LGRTV300E
287 580 1680 59 Stainless steel Paint Epoxy White NC 3 60 ~ 90 Single LDx 2101 Stainless steel 80 25 25 22 22 1/220-240V 50Hz

kW C

C mm mm mm mm /V/Hz

SANITARY WATER TANK DOUBLE COIL


LGRTV200VE LGRTV300VE 198 LITERS 287 LITERS

MANDATORy OPTIONAL ACCESSORIES


Sanitary Tank Installation Kit PHLTA PHLTA

saniTary WaTEr Tank douBLE CoiL


SANITARy WATER TANK
GENERAL CHARACTERISTICS Water Volume Diameter Height Empty Weight Tank Materials Outer Skin Materials Color White RAL CHARACTERISTICS OF ELECTRICAL BACK-UP Additional Electric Heater Adjustable Thermostat CHARACTERISTICS OF ExCHANGER Exchanger Type Material Exchanger Maximum Water Temperature HyDRAULIC CONNECTIONS HEAT PUMP THERMA V Entry THERMA V Exit HyDRAULIC CONNECTIONS SANITARy WATER City Water Entry Hot water Exit ELECTRIC CONNECTION Supply L mm mm kg

LGRTV200VE
198 580 1230 50 Stainless steel Paint Epoxy White NC 3 60 ~ 90 Double LDx 2101 Stainless steel 80 (With an Heat Pump) 25 25 22 22 1/220-240V 50Hz

LGRTV300VE
287 580 1680 64 Stainless steel Paint Epoxy White NC 3 60 ~ 90 Double LDx 2101 Stainless steel 80 (With an Heat Pump) 25 25 22 22 1/220-240V 50Hz

kW C

SOLAR PANELS FOR DOUBLE COIL TANK


For better performance and energy saving, it is possible to combine the THERMA V heat pump with solar panels.

C mm mm mm mm /V/Hz

MANDATORy OPTIONAL ACCESSORIES


Sanitary Tank Installation Kit PHLTA PHLTA

LG Air Conditioners 2011

28 /

29

Flexible Application for new Housing

Application 1
> Monovalent operation mode > Functions :
Underfloor Heating Low Temperature Radiators Generation of Sanitary Hot Water: Heat pump + Additional Electric Tank

Application 3
> Monovalent operation mode > Functions :
Underfloor Heating

Controller

Check Valve

Check Valve

Application 2
> Monovalent operation mode > Functions :
Underfloor Heating Low Temperature Radiators Generation of Sanitary Hot Water: Heat pump + Additional Electric Tank + Solar Panels

Application 4
> Monovalent operation mode > Functions :
Low Temperature Radiators

Check Valve Check Valve

Warning :
The recommended installation schemes are provided as a rough guide and are not a substitute for thorough hydraulic research performed by a professional based on the houses characteristics. LG is not responsible for damage resulting from not following this warning.

Warning :
The recommended installation schemes are provided as a rough guide and are not a substitute for thorough hydraulic research performed by a professional based on the houses characteristics. LG is not responsible for damage resulting from not following this warning.
30 /

LG Air Conditioners 2011

31