Вы находитесь на странице: 1из 4

INDOOR UNIT

Ceiling cassette type


4-way airflow

PLFY-P VCM-E/VAM-E
VCM

PLFY-P VCM-E PLFY-P VAM-E

VAM

The new compact cassette VCM is suitable for 2x2 ceiling!


compact body to match with 2feets (600mm) x 2feets (600mm) ceiling design (VCM)

570mm

570mm

Easy Installation
Only two panel sizesperfectly suited to various installation configurations
Only two panel sizes are available,650mm(255/8in.) for the compact VCM and 950mm(377/16in.) for the power cassette VAM. The VCM is lightweight min.15kg(34lbs)(P20/P25)

Superb Features
First in the industry to offer 72 airflow patterns (power cassette VAM)
The 72 different airflow patterns provide the best solution for varying room layouts and air-conditioning requirements. For extra versatility, you can also select from two-, three- or four-way outlets. What's more, the addition of separate motors to the individual vanes enables manual control that-together with remote control vane settings-make possible highly customized and flexible airflow patterns.

Drain water pipe lifted to 850mm(33-1/2in.) (power cassette VAM)


The drain piping of the VAM can be positioned anywhere up to 850mm(33-1/2in.) from the ceiling's surface, allowing greater freedom with long cross-piping and more versatility with piping layouts (VCM: 500mm(19-11/16in.)).

PLFY-VCM Type

PLFY-VAM Type

850mm (33-1/2in.)

650mm (25-5/8in.)

950mm (37-7/16in.)

4-, 3-, or 2way outlet selection

Unit height of only 208mm*1 great for low-ceiling space situations


(compact cassette VCM)

Handy corner-pocket design simplifies maintenance and installation (power cassette VAM)
By using the handy corner pockets equipped on four corners of the grille, maintenance work such as drain pan cleaning and height adjustment can be accomplished without removing the grille. It is also easier to adjust the ceiling height of the indoor unit during installation.

The new compact cassette VCM has a unit height of only 208mm*1, to realize neat installation in low-ceiling situations with very limited space. *:8-1/4in

Fixed airflow direction per vane

Motor for the vane

72 airflow patterns
*Optional air outlet shutter plate is necessary for two-or three-way airflow settings. The noise level may increase during two-or three-way airflow setup. *For VCM model, 2 or 3 way airflow is not available.

Only 208mm*!

27

INDOOR UNIT

Ceiling cassette type


4-way airflow

PLFY-P VCM-E PLFY-P VAM-E


Superb Features
For Retail Outlets (Power cassette VAM)
These units are ideal for maintaining constant temperatures in environments that have equipment such as refrigerate showcases. Individual vane angle adjustment enables precise airflow control to specific areas of the store to reduce unnecessary air conditioning of areas such as refrigerated showcases.
Remote control setting for two directions Fixed vane for two directions

Outstanding Specifications
Wide-flow air outlet delivers a comforting breeze (VAM)
The airflow of the VAM power cassette is powerful enough to warm atrium-type ceilings up to 4.2 meter(13-13/16Ft) in height.
4-way high ceiling 2 (VAM) 4-way standard (VAM)

Smudge-free airflow prevents soiling of the ceiling surface (power cassette VAM )
Mitsubishi Electric has developed a new airflow control mechanism where a projection inside the air passage distributes air evenly over the vane's upper and lower surface while two additional projections at the air outlet's exit adjust the angle of the airflow. This helps to prevent indoor air from rising, stopping it from hitting the surface of the ceiling to reduce the likelihood of soiling from smudging and condensation.

4.2m (13-13/16Ft)

3.2m (10-1/2Ft)

Fixed Fixed

Smudging and the new airflow control mechanism


Outside Inside

3.6m (11-13/16Ft)

3-way standard (VAM)

Specifications according to ceiling height and number of vents


1

Power Cassette VAM


Standard High ceiling 1 High ceiling 2 3.6 4.0 4.2 4.2 4.2 --2

Top or bottom airflow setting via remote controller

Fixed
Refrigerated showcase not affected by air conditioning

Grille
1

Vane

Fixed
A projection is created on the outside, where the airflow is fastest. This diverts the airflow and distributes it evenly over the upper and lower surfaces of the Vane. The air outlet exit also has projections to prevent air from rising within the room and stopping it from hitting the ceiling.

4-way 3-way 2-way

3.2 3.6 4.0

2 3

*VCM:2.7m(standard/4way only)

Wider airflow setting reduces annoying drafts


Smudging:
30 horizontal position 30 70 70 vertical position
When cooled air is expelled horizontally, it tends to cling to the surface of the ceiling. This cools the surface down and causes condensation, which attracts dust from the room's interior to soil the ceiling's surface.

Functional and appealing vane shutter (power cassette VAM)


When the air conditioner is not operating, the vane shutter closes automatically to conceal the air outlet and create an aesthetically appealing flat surface.*
*This feature will not activate when the vane is set at fixed position.

Compatible with both round and square ducts (power cassette VAM)
For easy connection to branch ducts, knockout holes are designed to fit both round and square ducts. Matching the shape of the duct fringe provides more flexibility during installation.
Connecting to round ducts

Bristle-free vane can be cleaned simply (power cassette VAM )


The unique suction mechanism prevents indoor air from rising to eliminate condensation on the vane and make bristles unnecessary.
During operation When turned off

(power cassette VAM &compact cassette VCM)


150mm(5-15/16in.) diameter cutout

Direct intake of fresh exterior air

Connecting to rectangular ducts

Indoor air quality is significantly enhanced by the direct intake of fresh exterior air. An optional multi-function casement is also available (only for VAM) for the intake of a larger volume of air.

350mm(13-13/16in.)~100mm(3-15/16in.) cutout

28

INDOOR UNIT

Specifications & External Dimensions

For 50Hz Area only

PLFY-P VCM-E
Specifications
PLFY-P20VCM-E
Power source B1 B1 B1 Heating capacity B1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) Height Dimension B 2 Width Depth Net weight B 2 Heat exchanger Type Cooling capacity Airflow rate B 2 (Low-Mid-High) kW Btu/h kW Btu/h kW kW A A mm(in.) mm(in.) mm(in.) kg(lbs.)

PLFY-P25VCM-E

PLFY-P32VCM-E

PLFY-P40VCM-E

~ (Single phase), 220-230-240V 50Hz 2.2 2.8 3.6 4.5 7,500 9,600 12,300 15,400 5.0 2.5 3,2 4.0 8,500 10,900 13,600 17,100 0.06 0.06 0.05 0.05 0.06 0.05 0.06 0.05 0.28 0.28 0.23 0.23 0.28 0.23 0.28 0.23 Unit: Galvanized sheets with gray heat insulation, Panel: Munsell 0.70Y 8.59/0.97 Unit: 208(8-1/4"), Panel: 20(13/16") Unit: 570(22-1/2"), Panel: 650(25-5/8") Unit: 570(22-1/2"), Panel: 650(25-5/8") Unit: 15.5<3>(35<7>) Unit: 15.5<3>(35<7>) Unit: 17<3>(38<7>) Unit: 17<3>(38<7>) Cross fin (Aluminum plate fin and copper tube) Turbo fan 1 8-9-10 133-150-167 283-318-353 8-9-10 133-150-167 283-318-353 0 (direct blow) 0.020 8-9-11 133-150-183 283-318-388 8-9-11 133-150-183 283-318-388

m3/min L/s cfm Pa

Fan

Single phase induction motor kW 0.011 0.015 0.020 PP Honey comb 12.7(1/2") mm(in) mm(in) 6.35(1/4") O.D. 32(1-1/4") O.D. 32(1-1/4") O.D. 32(1-1/4") dB(A) 28-31-35 28-31-37 29-33-38 Note: B 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27C(80.6F)DB/19C(66.2F)WB,Outdoor 35C(95F)DB Heating : Indoor 20C(68F)DB,Outdoor 7C(44.6F)DB/6C(42.8F)WB B2 External dimension/ net weight are shown in<unit/panel> , and airflow rate/noise level are in (low-middle2-middle1-high). B3 It is measured in anechoic room.

External static pressure Type Motor Output Air filter Refrigerant Gas(Flare) pipe diameter Liquid(Flare) Drain pipe diameter Noise level (Lo-Mid-Hi) B2 B3

O.D. 32(1-1/4") 30-34-39

External Dimensions
PLFY-P20,25,32,40VCM-E
15~37

Unit : mm
Fresh air intake
Ceiling hole

530

Suspension bolt pitch

Suspension bolt pitch

576~620

420

335

570

31 15~37 57

Detail drawing of fresh air intake hole


100 3-2.8hole Burring hole
25

56

73.4 Cut out hole

15~37

2 1
66

17

199 352 335 576~620 Ceiling hole 202 230

Drain pipe VP-25 connection (O.D.32)


15~37

Wiring entry Suspension bolt M10 or W3/8

87

570

208

118

121

93

193

235

12

38~58

+5

Ceiling surface

Suspension bolt lower edge

650 301

Air outlet hole


55 35

Brand label Grille

V/M

Drain hole
V/M

27

Terminal block

Grille

Ceiling surface

Air outlet hole

Air intake hole

650

301

377

20

Auto vane

48

182

0 12

Models
V/M

1 Refrigerant pipe (6.35mm dia.) flared connection 1/4F

2 Refrigerant pipe (12.7mm dia.) flared connection 1/2F

V/M

Air intake grille Vane motor

PLFY-P20VCM-E PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E

35 55

377

Air intake hole

41

INDOOR UNIT

Specifications & External Dimensions

PLFY-P VAM-E
Specifications
PLFY-P32VAM-E
Power source

PLFY-P40VAM-E
4.5 15,400 4.7 4,000 5.0 4,300 17,100

PLFY-P50VAM-E
5.6 19,100 5.8 5,000 6.3 5,400 21,500

PLFY-P63VAM-E

PLFY-P80VAM-E
9.0 30,700 9.3 8,000 10.0 8,600 34,100 0.18 0.18 0.86 0.86

PLFY-P100VAM-E
11.2 38,200 11.6 10,000 12.5 10,800 42,700 0.30 0.30 1.43 1.43

PLFY-P125VAM-E
14.0 47,800 14.5 12,500 16.0 13,800 54,600 0.34 0.34 1.64 1.64

B1 B1 Cooling capacity B2 B2 B1 Heating capacity B1 B1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) Dimension H x W x D B 3
Net weight Heat exchanger Type Fan B3

kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A mm in. kg(lbs.)

3.6 12,300 3.7 3,150 4.0 3,400 13,600 0.12 0.12 0.59 0.59

~ 220-240V 50Hz / ~ 220V 60Hz 7.1 24,200 7.3 6,300 8.0 6,900 27,300 0.14 0.16 0.14 0.16 0.68 0.78 0.68 0.78 Panel : 0.70Y 8.59/0.97 258<30>x 840<950> x 840<950> 10-3/16"<1-3/16"> x 33-1/8"<37-7/16"> x 33-1/8"<37-7/16"> 22<5>(49<12>) 24<5>(53<12>) Cross fin (Aluminum plate fin and copper tube) Turbo fan 12-13-14-16 200-217-233-267 424-459-494-565 14-15-16-18 233-250-267-300 494-530-565-636

298(30) x 840(950) x 840(950) 11-3/4"<1-3/16"> x 33-1/8"<37-7/16"> x 33-1/8"<37-7/16"> 32<5>(71<12>)

Airflow rate B3 (Low-Mid2-Mid1-High)

m3/min L/s cfm Pa kW mm(in.) mm(in.) dB(A)

11-12-13-14 183-200-217-233 388-424-459-494

16-18-20-22 267-300-333-367 565-636-706-777

19-22-25-27 317-367-417-450 671-777-883-953

21-24-27-29 350-400-450-483 742-848-953-1024

External static pressure Type Motor Output Air filter Refrigerant pipe diameter (Flare)

0
Single phase induction motor

0.070 PP Honeycomb
12.7 (1/2")
12.7(1/2") / 15.88(5/8") (Compatible) 6.35(1/4") / 9.52(3/8") (Compatible)

0.120 15.88(5/8")
9.52 (3/8") O.D. 32 (VP-25) 28-29-31-33
15.88

Gas

(5/8")/

19.05(3/4") (Compatible)

(Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) B3 B4

Liquid

6.35 (1/4") 27-28-29-31

27-28-30-32

30-32-35-37

33-36-39-41

35-38-41-43

Note: B 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27 C(80.6F) DB/19C(66.2F) WB,Outdoor 35C(95F)DB Heating : Indoor 20C(68F) DB,Outdoor 7C(44.6F) DB/6C(42.8F) WB B 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27C(80.6F)DB/19.5C(67.1F)WB,Outdoor 35C(95F)DB (WR2: water 30C(80F)) Heating : Indoor 21C(69.8F)DB,Outdoor 7C(44.6F)DB/6C(42.8F)WB (WR2: water 20C(68F)) B 3 External dimension/ net weight are shown in <unit/panel> , and airflow rate/noise level are in (low-middle2-middle1-high). B 4 It is measured in anechoic room.

External Dimensions
PLFY-P32,40,50,63,80,100,125VAM-E
20~45 90 100 100 90
70

Ceiling hole 860~910 159 810 Suspension bolt pitch

Unit : mm
20~45
20~45 Suspension bolt pitch 605 159 16

Branch duct hole (Cut out hole)


100 130

Fresh air intake

155

167

159

150

840

175

350

Branch duct hole 14 - 2.8 Burring hole

Terminal block

197

159 840

120

120

125

100 (Cut out hole)

158

Suspension bolt M10 or W3/8

1 2

60

Feeding hole (Drain pump) 286 374

Drain pipe VP-25connection (O.D. 32)

Ceiling surface
170 140 105 190

50~70

Suspension bolt lower edge

Power line entry Air intake grille

Control wire entry

Ceiling surface

577 Air intake hole


M

Grille Drain hole

High efficiency filter & Fresh air intake casement (option)

17 +5 0

135

Auto vane
577 Air intake hole

Models PLFY-P32VAM-E PLFY-P40VAM-E PLFY-P50VAM-E PLFY-P63VAM-E PLFY-P80VAM-E PLFY-P100VAM-E PLFY-P125VAM-E

6.35

12.7
258
77

6.35(R410A) 12.7(R410A) 241 9.52(R407C,R22) 15.88(R407C,R22) 15.88 9.52 15.88(R410A) 281 19.05(R407C,R22)

950

Liquid Pipe

Gas Pipe

411 Air outlet hole

Vane motor 77 51

298

411 Air outlet hole 950

51

17 +5 0 30

20~45

3 - 2.8 Burring hole

98

89

Detail drawing of fresh air intake hole

192

860~910 Ceiling hole

Branch duct hole

42

Вам также может понравиться