Вы находитесь на странице: 1из 8

www.marcomweb.

it
Features
High speed: communication on Ethernet network assure high speed Simple and fast configuration Extremely cheap: licences linked to variables count to fit every needs

Main Features
Access to datas of S7-300, S7-400 , S71 200, S7-200 PLC Series Supports all data type Smart configurator with syntax errors discover and notification Siemens Step7 integration OPC Data Access 2.04 interface Optimized reads for a fast communication Varaibles import from Step7 project keeping namesapce Compatible with all Microsoft Operating Systems 32 bit and 64 bit Works as Windows Service for PC without GUI

OPC SERVER S7.NET OPC-MS7N


OPC Server to communicate with Siemens PLC: S7-200, S7-300, S7-400 and new S7-1 200, on Ethernet network!
Marcom OPC Server S7.NET allows to access easily and quickly to process datas of S7-200 (via CP243), S7-300, S7-400 and S7-1 200 controllers, using one single server. Varaibles are addressed using STEP7 semantic usual in Siemens software development enviroment. With any client application compatible with OPC specification can read and write input and output datas, datablock and merker.

MARCOM S.r.l. Automazioni basate sulle nuove tecnologie

TECHNICAL DATA Connections Supported Data Types Configuration Data access to S7-200, S7-300, S7-400, S7-1 200 PLC bool, byte, word, int, dword, dint, real, time, timer, counter Smart configurator with syntax error discover Step7 integration advanced tool Variables import from Step7 project Compatible with Data Access 2.04 Specification All interfaces included in DA Specification Static Namespace imported by Step7 variant UI1 , I1 , UI2, I2, UI4, I4, R4, R8, bool Win 2000, XP, Server 2003, 2008, Windows 7 - 32/64 bit Yes Licenses divided by variables number

OPC Specifications OPC interfaces OPC Data Types Supported OS Multilanguage Support License

PRODUCT CODE OPC-MS7N1 OPC-MS7N2 OPC-MS7N3 OPC-MS7N License on USB key for 50 points License on USB key for 500 points License on USB key for 1 000 points License on USB key unlimited

www.marcomweb.it

www.marcomweb.it
Features
High speed: communication on Ethernet network assure high speed Simple and fast configuration Extremely cheap: licences linked to variables count to fit every needs

Main Features
Access to datas of all eenrgy meters that implement DLMS standard (IEC62056, IEC-62056-21 , IEC-62056-42, IEC-62056-43, IEC-62056-61 , IEC62056-53, IEC-62056-46) Automatic variables configuration: download variables list from device Optimized and fast communication Compatible with future meters Compatible with all Microsoft Operating Systems 32 bit and 64 bit

OPC SERVER DLMS OPC-MDLMS


OPC Server to communicate with energy meters that implement IEC-62056, -21 , -42, -43, -61 , -53, -46 standards.
OPC Server to communicate with energy meters that implement DLMS protocol (IEC-62056, IEC62056-21 , IEC-62056-42, IEC-62056-43, IEC-62056-61 , IEC-62056-53, IEC-62056-46 standards). It supports serial communication througth RS232, RS485 and with optical probe. Ideal to monitor major manufacturers energy meters: Landis+Gyr, Azur Energia, Iskraemeco, EMH, Actaris, Elster, Sagem, PowerLogic, Elgama-Elektronika, Enerlux, DPEE, ...

MARCOM S.r.l. Automazioni basate sulle nuove tecnologie

TECHNICAL DATA Connections Supported Data Types Configuration Access to alla datas in meters of main manufacturers All datas: instantaneous and totalized values Smart configurator with syntax error discover Advanced tool to discover and download variables from meters and automatic configuration build Compatible with Data Access 2.04 Specification All interfaces included in DA Specification variant UI1 , I1 , UI2, I2, UI4, I4, R4, R8, bool Win 2000, XP, Server 2003, 2008, Windows 7 - 32 / 64 bit Yes Licenses divided by meters number PRODUCT CODE OPC-MDLMS1 OPC-MDLMS2 OPC-MDLMS3 License on USB key for 5 meters License on USB key for 1 0 meters License on USB key for 25 meters

OPC Specification OPC Interfaces OPC Data Types Supported OS Multilanguage Support License

www.marcomweb.it

www.marcomweb.it
Features
High speed: communication on Ethernet network assure high speed Simple and fast configuration Extremely cheap: licences linked to variables count to fit every needs

Main Features
Access to different devices through Ethernet (TCP, UDP) or RS232 / RS422 / RS485 Smart configurator Nno standard devices support (es. Thytronic) Direct operations on datas Optimized reads to fast data transfer Automatic read and write of bits inside a word Compatible with all Microsoft Operating Systems 32 bit and 64 bit Variables scaling on OPC

OPC SERVER MODNET OPC-MODB


Communicate with all Modbus devices through TCP or RTU protocol. Developed on .NET technology.
OPC Server Modbus TCP/IP is the ideal tool to connect field devices with Ethernet MODBUS o MODBUS RTU interfaces to control or SCADA systems. Software completed with tools to analyze and monitor traffic on the network (performance analysis) and communication diagnostic on OPC variables. Smart algorithm to optimize communication, first of all on serial networks.

MARCOM S.r.l. Automazioni basate sulle nuove tecnologie

TECHNICAL DATA Connections Supported Data Types Configuration Access to devices on ethernet (TCP, UDP), RS232/422/485 int 1 6/32bit signed/unsigned, real 1 6/32 bit, bool, bcd Smart configurator with syntax error discover Advanced traffic diagnostic tool Advanced network performace monitor Compatible with Data Access 2.04 Specification All interfaces included in DA Specification variant UI1 , I1 , UI2, I2, UI4, I4, R4, R8, bool Variables scaling at OPC level Swap of byte, word, double word Block data transfer with modifiable offset Support for non standard devices (es. Thytronic) Win 2000, XP, Server 2003, 2008, Windows 7 - 32 / 64 bit Yes Licenses divided by variables number PRODUCT CODE OPC-MODB1 OPC-MODB2 OPC-MODB3 OPC-MODB OPC-MODBS1 OPC-MODBS2 OPC-MODBS3 OPC-MODBSC OPC-MODBSR License on USB key for 50 points License on USB key for 500 points License on USB key for 1 000 points License on USB key unlimited License on USB key for 50 points - as service License on USB key for 500 points - as service License on USB key for 1 000 points - as service Corporate License TCP protocol Corporate License Serial protocol

OPC Specification OPC Interfaces OPC Data Types Additional Features

Supported OS Multilanguage Support License

www.marcomweb.it

www.marcomweb.it
Features
High speed: communication on Ethernet network assure high speed Simple and fast configuration Extremely cheap: licences linked to variables count to fit every needs

Main Features
Access to different devices through Ethernet network (TCP, UDP) Smart configurator allows to download variables from inverter itself Modifiable polling interval: from 1 0 seconds to 1 week Optimized reads to fast data transfer Compatible with all Microsoft Operating Systems 32 bit and 64 bit Variables scaling on OPC

OPC SERVER SMA OPC-MCSMA


OPC Server to connect to SMA inverters. Allows to read all inverter measurements and status of production.
OPC Server SMA is the ideal tool to monitor production of SMA inverter and to keep monitored states and faults to minimize non-productive periods. Link established through Sunny WebBox (sold separately). Allows to read, easily and quickly, all inverter production measurements and status. Ideal for remote plants with UMTS/GPRS routers.

MARCOM S.r.l. Automazioni basate sulle nuove tecnologie

TECHNICAL DATA Connections Supported Data Types Configuration Access to all devices on Ethernet TCP network int 1 6/32bit signed/unsigned, real 1 6/32 bit, bool, bcd Smart configurator with syntax error discover Automatic download of inverter variables list Advanced traffic diagnostic tool Compatible with Data Access 2.04 Specification All interfaces included in DA Specification variant UI1 , I1 , UI2, I2, UI4, I4, R4, R8, bool Variables scaling at OPC level Variables refresh at modifiable interval Block data transfer with modifiable offset Simulation mode Win 2000, XP, Server 2003, 2008, Windows 7 - 32 / 64 bit Yes Licenses divided by variables number PRODUCT CODE OPC-MCSMA1 OPC-MCSMA2 OPC-MCSMA3 OPC-MCSMA License on USB key for 50 points License on USB key for 500 points License on USB key for 1 000 points License on USB key unlimited

OPC Specification OPC Interfaces OPC Data Types Additional Features

Supported OS Multilanguage Support License

www.marcomweb.it