Plumbing- DrainageSystems Pipe jointing methods Equipments, Health fixtures (Sanitary wares) & Accessories Remarks

Sl No

System

Type of Piping materials

uPVC_ unPlasticised Poly Vinyl Chloride Product: Hepworth, Zurn etc.,

1. Jointing of Double ring socket, Wye joints & Elbows (92.5deg, 45deg), Cleanouts & Male/Female threaded plug using lubricants

U-PVC Class E Pipe: Unplasticised Poly vinyl chloride, Class E - 15 bar rating (most commonly used only for underground pipes) Product: Hepworth, Zurn etc.,

Water Supply

1. Solvent welded joints using solvent cements Product: Parabond 2. Union Threaded joints where there is a issue of maintenance like valve chambers, nearby HVAC Equipments Condensate drain 3. Male/Female threaded plug

Cast iron Pipe

Pipe & Elbows ,Wye fittings is been jointed by No-Hub coupling & Time saver coupling

Copper Pipe - Used for carrying the Condensate water of Air Handling unit & Fan Coil unit

1. Compressed threaded joint 2. Welding or Soldering or copper brazing joints

1. Wash basin : Single waste point at the centre of fixture 2. Kitchen sink : Single waste point at the centre of fixture 3. Bidet (Urinal for Women) : Single waste point at the centre of fixture 4. Urainal for men : Single waste point at the centre of fixture 5. Water Closet: Single soil point at the centre of fixture 6. Shower / Bath tub /Jagguzi: Single waste point at the centre of fixture 7. Swimming pool: Single waste point at the lowest point of pool & Drain from Back wash chamber 8. Sump Pumps - For Storm water system ( Using uPVC (Class E 15 Bar) pipes or Ductile iron pipe), With NRV, Gate Valve, Float Switch & Lifting Mechanism such as Lifting chain with D- Shackles or eye-bolts, 9. Pump Room Works: Tank drain 10.Parking drains & Wet area (Pantry / Toilet) floor drain 11. Oil Interceptor or Sand trap at the Basement or Car wash areas (To seperate the these two items from mixing into Main sewer lines) 12. Heavy duty gratings - Vehicular area like road & Light duty gratings - Pedestrain walk area, 13. Maholes & Gully traps - To transfer the building out of it & End with House connection unit, called First inspection chamber or Manhole number 01, 14. All trap is been provided with water seal of depth minimum of 75mm, to trap the foul smell entering back into building, 15. Roof rain water drain, 16. Acoustic / Sound lag _ used to wrap the drainage pipe that passing thru office or showroom areas, 17. Insulation for HVAC Equipments condensate drain pipe; And cladding required for Sunlight exposed or naked pipes, 18. All drainage pipe can be vented thru atmosphere so as to ease the drainage process & Venting out the foul smell capped by vent cowl or balloon grating

1. All Santary wares or Health fixtures control can manual or automatic. 2. For Every Change in direction of pipes, cleanout or rooding eye for Maintenance, 3. Testing of drain pipe is by pouring the water into the pipe, Called Gravity testing 4. Insulation or Acoustic lagging can be done with respect to the project spec or manufacturer technical datas, 7. Sleeve closing a)Firestop material can be applied between the line/pipe and sleeve penetrations into the fire rated wall, b) Polyurethane foam or any approved synthetic sealant can aplied for the same in case of non-fire rared walls or conditions 8. Pipe size get increased from point of sanitary wares to manhole , 9. Rain water pipe can be sized according to roof area & annual rainfall rate (Recorded value of 100 years) 10. Universal Service clearance of 1" ( Minimum) shall be given between pipes & any other services or walls while installations 11. All material to be used in the project must be approved by the engineer or contractor before proceeding to installations) 12. Once the Installation & Testing of Water Supply pipes is been completed, The particaular area should be immediately released / handed over to the maincontractor or Engineer _for to other subcontractor to carryout their