Вы находитесь на странице: 1из 44

Proprietary Use pursuant

Solely
to Company
for authorized
instruction
persons having a need to know

Title page

Alcatel-Lucent 1626LM
1626 Light Manager | Release 3.0A
Health Check: Anticipating Line or Equipment Degradation or Failure

1626LM R3.0 OPERATOR HANDBOOK ADDENDUM


3AL 94322 FAAA
ISSUE 1
FEBRUARY 2010
Alcatel-Lucent Confidential
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Proprietary Use pursuant


Solely
to Company
for authorized
instruction
persons having a need to know
Legal notice
Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2010 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
ot to be used or disclosed except in accordance with applicable agreements.
Security Statement

In rare instances, unauthorized individuals make connections to the telecommunications network through the use of remote access features. In such an event,
applicable tariffs require that the customer pay all network charges for traffic. Alcatel-Lucent cannot be responsible for such charges and will not make any
allowances or give any credit for charges that result from unauthorized access.
Limited Warranty

For terms and conditions of sale, contact your Alcatel-Lucent Account Team.
Ordering information

The ordering number for this product guide is 3AL 94322 FAAA.
To order Alcatel-Lucent documents, contact your local sales representatives or use Online Customer Support (OLCS) https://support.lucent.com
(http://support.alcatel-lucent.com) .

Alcatel-Lucent Confidential
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Contents

About this document


Purpose

............................................................................................................................................................................................. ix
ix

Intended audience

......................................................................................................................................................................... ix
ix

Related documents
Related training

....................................................................................................................................................................... ix
ix

............................................................................................................................................................................. ix
ix

Technical support .......................................................................................................................................................................... ix


ix
How to order documents
Quality policy

.................................................................................................................................................................................. x
x

How to comment
1

............................................................................................................................................................ ix
ix

............................................................................................................................................................................ x
x

Recognizing Line Degradation or Line Break


Overview ....................................................................................................................................................................................... 1-1
1-1
Operation Prerequisites ............................................................................................................................................................ 1-1
1-1
COCE (Configuration Or Customization Error)
IPD (Input Power Degraded)

............................................................................................................ 1-2

................................................................................................................................................. 1-3
1-3

IPL (Input Power Loss) ............................................................................................................................................................ 1-4


1-4
LOSCF (Loss Of Supervisory Channel Frame) .............................................................................................................. 1-6
LTCER (Low Threshold Corrected Error) ........................................................................................................................ 1-7
2

Recognizing Equipment Degradation or Failure


Overview ....................................................................................................................................................................................... 2-1
2-1
Follow the Rules
Operation Prerequisites ............................................................................................................................................................ 2-2
2-2
Operation Recommendation

.................................................................................................................................................. 2-2
2-2

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
iii
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Contents
...................................................................................................................................................................................................................................

Generic Degradation or Failure Alarms


Overview ....................................................................................................................................................................................... 2-3
2-3
HT (High Temperature)

........................................................................................................................................................... 2-4
2-4

RUP (Replaceable Unit Problem)

........................................................................................................................................ 2-5
2-5

URU (Underlying Resource Unavailable)

........................................................................................................................ 2-6

Transponder Degradation Alarms


Overview ....................................................................................................................................................................................... 2-7
2-7
OPD (Output Power Degraded) ............................................................................................................................................ 2-8
TD (Transmitter Degraded) .................................................................................................................................................... 2-9
2-9
WD (Wavelength Deviation) ............................................................................................................................................... 2-10
2-10
Amplifier Degradation Alarm
Overview

.................................................................................................................................................................................... 2-11
2-11

TD (Transmitter Degraded)

................................................................................................................................................. 2-12
2-12

HVCSP (Heating or ventilation or Cooling System Problem)


3

............................................................................... 2-13

LOFA Input Signal Degradation Threshold Management


Overview ....................................................................................................................................................................................... 3-1
3-1
IPD Threshold Table Management
Overview ....................................................................................................................................................................................... 3-2
3-2
About IPD Alarm Threshold .................................................................................................................................................. 3-2
3-2
IPD Threshold Configuration Guidelines
Displaying Board Alarm Threshold
Creating Alarm Threshold Tables

.................................................................................................................................... 3-5

........................................................................................................................................ 3-6
3-6

Assigning an Alarm Threshold to a Board


Modifying Alarm Threshold Tables
Deleting Alarm Threshold Tables

......................................................................................................................... 3-4

....................................................................................................................... 3-8

.................................................................................................................................... 3-9

...................................................................................................................................... 3-11
3-11

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

iv

List of tables

3-1

IPD Alarm Threshold Values ................................................................................................................................. 3-3

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
v
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

List of figures

1-1

Alarm Diagram ........................................................................................................................................................... 1-5


1-5

3-1

Power Alarm Raise Logic ....................................................................................................................................... 3-3

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
vii
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

About this document


About this document

Purpose

The aim of this Health Check document is to provide operators of 1626 Light Manager
systems release 3.0A, with the relevant information:

to anticipate TRBD and LOFA boards degradation or failures,


to detect line degradation or break.

Intended audience

This Health Check document addresses 1626 Light Manager operators who need to be
assisted in understanding or performing TRBD, LOFA and line trouble shooting, based on
equipment and line degradation or failure alarms.
Related documents

1626LM R3.0 Operator Handbook


Related training

Alcatel-Lucent University provides courses to train telecommunication technicians in


installation, operations, and maintenance. Contact Alcatel-Lucent at 1-888-582-3688 to
enroll in training classes.
Technical support

For technical support, contact your local customer support team. Reach them via the web
at http://alcatel-lucent.com/support or through the telephone number listed under the
Technical Assistance Center menu at https://support.lucent.com/portal/olcsHome.do
(https://support.lucent.com/portal/olcsHome.do) .
How to order documents

To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS)https://support.lucent.com (http://support.alcatel-lucent.com)

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
ix
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

About this document


...................................................................................................................................................................................................................................

Quality policy

We ensure that everything we do must be focused on becoming the trusted partner of our
customers by:

Delivering high quality, secure and reliable products, services, software and solutions
the first time, every time, and on time - as promised.
Continuously making improvements and looking for innovative ways to anticipate
and fully meet the highest expectations of our customers.
Counting on all employees to be personally accountable for putting the customer first
and honoring the commitments we make.

How to comment

To comment on this document, go to the Online Comment Form (http://infodoc.


alcatel-lucent.com/comments/enus/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com) .

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

1ecognizing Line
R
Degradation or Line Break

Overview
Purpose

This chapter lists and describes all the alarms which warn line degradation or line break,
and associated trouble shooting tasks to be performed to clear such alarms.
Contents
Operation Prerequisites

1-1

COCE (Configuration Or Customization Error)

1-2

IPD (Input Power Degraded)

1-3

IPL (Input Power Loss)

1-4

LOSCF (Loss Of Supervisory Channel Frame)

1-6

LTCER (Low Threshold Corrected Error)

1-7

Operation Prerequisites
About an optimum operation context
To guarantee an optimum operation context, you must observe the following rules:

Be compliant with line tuning rules:

Check that LDT (Line Tuning Table) guidelines have been implemented.

Check that Audit Tool results display a perfect match between LDT values
and actual values.

Perform NE instantaneous measurements after each network element upgrade.

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
1-1
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Line Degradation or Line Break

COCE (Configuration Or Customization Error)

...................................................................................................................................................................................................................................

COCE (Configuration Or Customization Error)


COCE (Configuration Or Customization Error)
Description

Probable Cause

Related Alarms

Indicates that ALCT or LOFA boards are working


out of acceptable range of value regarding laser
output power and optical attenuation.

COCE is an indication to inform that these devices


are currently not used as they have been designed
for typical use after network designer decision.

COCE does not necessarily imply any malfunction


or failure.

COCE alarm may be raised:

following particular tuning due to specific


configuration,

after line modification which implies a variation of


LOFA input power.

one.
Corrective Actions

On-Site Intervention Required

Yes, in certain circumstances.

Actions

1. If span loss is too high compared to the


specification, clean the connectors.
2. If the span loss is too low compared to the
specification (attenuators may have been forgotten),
adjust the value accordingly.
3. If the problem persists, contact Alcatel-Lucent
Support Team.
4. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

1-2

Recognizing Line Degradation or Line Break

IPD (Input Power Degraded)

...................................................................................................................................................................................................................................

IPD (Input Power Degraded)


IPD (Input Power Degraded)
Description

A LOFA has detected a degraded incoming signal at


stage input.

Probable Cause

The input power at LOFA stage input is lower or higher


than the configured threshold value for this alarm.

Related Alarms

one.
Corrective Actions

On-Site Intervention Required

Depending on the fault location.

Actions

1. Check the mechanical aspect of the fiber


(Connection at stage input and fiber aspect).
2. Check that LOFA threshold value is set at the right
value according to the specific line context.
3. If the alarm persists, contact Alcatel-Lucent
Technical Support Team.

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
1-3
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Line Degradation or Line Break

IPL (Input Power Loss)

...................................................................................................................................................................................................................................

IPL (Input Power Loss)


IPL (Input Power Loss)
Description

Optical power loss at input port.


Traffic may be interrupted.

Probable Cause

Related Alarms

The fiber may be unplugged

The fiber between the impacted board and the previous transmission device may
be broken.

The transmitter of the previous transmission device may be in failure.

The following alarms may be raised:

LOS (Loss Of Signal) raised by OTS block,

LOMS (Loss Of Multiplex Section).

LOSC (Loss of Supervisory Channel)

URU (Underlying Resource Unavailable)


Corrective Actions

On-Site Intervention
Required

Yes.

Actions

1. Check the fiber connection.


2. If the problem persists, analyze the alarms (See Figure 1-1, Alarm Diagram
(p. 1-5).
If

a. URU alarm is raised, then a failure has occurred on the network element.
b. IPL and LOS from an OTS block are raised on the same network element,
then the reception fiber from the remote network element is broken.
In this case the network element detects a loss of multiplex section (LOMS)
and a loss of supervision channel (LOSC). The conjunction of these alarms
triggers a LOS at OTS level which is the signal of a fiber break at reception.
c. IPL and LOMS are raised on the same network element, the reception fiber is
not broken.
Basically, the network element detects a loss of channel reception. As LOSC
is not raised, the supervision channel is still active. As a consequence, the
reception fiber is not broken.
This case is typical of the context of an automatic laser shutdown that a
remote network element performs with the effect of an IPL and a LOMS on a
given network element.
3. Perform the relevant actions on the faulty fiber, based on the alarm analysis.
4. If the alarm persists, contact Alcatel-Lucent Technical Support Team.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

1-4

Recognizing Line Degradation or Line Break

IPL (Input Power Loss)

...................................................................................................................................................................................................................................

Figure 1-1 Alarm Diagram

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
1-5
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Line Degradation or Line Break

LOSCF (Loss Of Supervisory Channel Frame)

...................................................................................................................................................................................................................................

LOSCF (Loss Of Supervisory Channel Frame)


LOSCF (Loss Of Supervisory Channel Frame)
Description

OSCU board receives a supervision signal but cannot


decode it.
LOSCF alarm is raised by OTS block related to the
LOFA board associated with the OSCU board.

Probable Cause

Related Alarms

Remote WDM equipment does not send the


compliant supervision frame,

Line degradation.

Power at board input is too low.

OSCU Rx is faulty.

one.
Corrective Actions

On-Site Intervention Required

Yes in certain circumstances.

Actions

1. Measure the power at OSCU input.


If the value is less than 54 dBm, or 51 dBm
(depending on the board generation), change the
board.
2. If not, check the configuration of the 2 OSCU
boards to determine if the clock configuration is
OK.
3. If the alarm persists, contact Alcatel-Lucent
Technical Support Team.
4. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

1-6

Recognizing Line Degradation or Line Break

LTCER (Low Threshold Corrected Error)

...................................................................................................................................................................................................................................

LTCER (Low Threshold Corrected Error)


LTCER (Low Threshold Corrected Error)
Description

Indicates a degradation of the transmission via high


correction rate (FEC).

Probable Cause

The transmitter of the previous transmission device


is degraded.

Tuning discrepancy between transponders and


amplifiers following a modification of the number
of WDM channels.

The fiber path between the 1626 LM and the


previous transmission device may be degraded.

Related Alarms

SSF (Server Signal Failure) generated on higher


impacted layers
Corrective Actions

On-Site Intervention Required

one.

Actions

1. Check the fiber connection.


2. Check the fiber between the 1626 LM and the
previous transmission device.
3. Measure the channel margin.
4. If necessary, tune the line (LOFA/ALCT) and/or the
channel (TRBC/TRBD) to recover the channel
margin.
5. End.

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
1-7
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

2ecognizing Equipment
R
Degradation or Failure

Overview
Purpose

This chapter lists and describes all the alarms which warn board degradation or failure
and associated trouble shooting tasks to be performed to clear such alarms.
Contents
Follow the Rules

2-2

Operation Prerequisites

2-2

Operation Recommendation

2-2

Generic Degradation or Failure Alarms

2-3

HT (High Temperature)

2-4

RUP (Replaceable Unit Problem)

2-5

URU (Underlying Resource Unavailable)

2-6

Transponder Degradation Alarms

2-7

OPD (Output Power Degraded)

2-8

TD (Transmitter Degraded)

2-9

WD (Wavelength Deviation)

2-10

Amplifier Degradation Alarm

2-11

TD (Transmitter Degraded)

2-12

HVCSP (Heating or ventilation or Cooling System Problem)

2-13

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-1
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Equipment Degradation or Failure

Follow the Rules


Operation Prerequisites

...................................................................................................................................................................................................................................

Follow the Rules


Operation Prerequisites
About an optimum operation context
To guarantee an optimum operation context, you must observe the following rules:

Be compliant with line tuning rules:

Check that LDT (Line Tuning Table) guidelines have been implemented.
Check that Audit Tool results display a perfect match between LDT values
and actual values.

Perform NE instantaneous measurements after each network element upgrade.

Operation Recommendation
About launching Performance Monitoring

In case of degradation alarm raised by a transponder board, launch Performance


Monitoring process to evaluate the urgency of planning a maintenance action.
Performance Monitoring process enables to watch the evolution of an event based on
counter value growth or decrease. In case of a rapid counter value growth you need to
plan a maintenance intervention within 2 days.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

2-2

Recognizing Equipment Degradation or Failure

Generic Degradation or Failure Alarms


Overview

...................................................................................................................................................................................................................................

Generic Degradation or Failure Alarms


Overview
Purpose

This section describes the alarms common to all boards which warn about board
degradation or failure:

HT and URU alarms which warn about board degradation,


RUP alarm which warn about board failure.

Contents
HT (High Temperature)

2-4

RUP (Replaceable Unit Problem)

2-5

URU (Underlying Resource Unavailable)

2-6

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-3
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Equipment Degradation or Failure

Generic Degradation or Failure Alarms


HT (High Temperature)

...................................................................................................................................................................................................................................

HT (High Temperature)
HT (High Temperature)
Description

Board temperature is greater than 50 C.


At 50 C the board still works. If the temperature
reaches 70 C, the board shuts down to protect the board
from an hardware failure.

Probable Cause

Related Alarms

etwork element configuration is not compliant


with Alcatel-Lucent recommendations.

Room air conditioning system does not work


properly.

Dust filter is dirty.

At least one of the 3 related fans has failed.

Yes, in certain circumstances.


Corrective Actions

On-Site Intervention Required

Yes.

Actions

1. Verify the installation conformity (the maximum


number of shelves in a rack must be 3).
2. Verify if air deflector and dummy plates are
positioned accordingly.
3. Verify if the room air conditioning system works
properly.
4. If necessary and according to your procedures, clean
or replace the dust filter.
5. If necessary, replace the faulty fans.
6. If necessary, replace the board.
7. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

2-4

Recognizing Equipment Degradation or Failure

Generic Degradation or Failure Alarms


RUP (Replaceable Unit Problem)

...................................................................................................................................................................................................................................

RUP (Replaceable Unit Problem)


RUP (Replaceable Unit Problem)
Description

RUP alarm can be raised in the following context:

An hardware component has failed. This may


impact the traffic.

Temperature has reached 70 C.

Note:Does not apply to SFP/XFP modules, nor to ESCT


boards.
Probable Cause

Related Alarms

Hardware failure, or

o possible communication between the shelf


controller and the board.

URU (Underlying Resource Unavailable)


Corrective Actions

On-Site Intervention Required

Yes.

Actions

1. Check if the incriminated board has raised an HT


alarm. If it is the case, perform the HT alarm
corrective actions.
2. If not, plug out and plug in the board.
3. If the alarm persists, replace the board.
4. End.

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-5
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Equipment Degradation or Failure

Generic Degradation or Failure Alarms


URU (Underlying Resource Unavailable)

...................................................................................................................................................................................................................................

URU (Underlying Resource Unavailable)


URU (Underlying Resource Unavailable)
Description

Indicates that an E internal failure has occurred. Can


be an hardware failure or an internal cabling failure.

Probable Cause

See Description.

Related Alarms

SSF (Server Signal failure)

Any Equipment alarms may potentially be raised.

Corrective Actions
On-Site Intervention Required

Yes.

Actions

1. Check the related alarm(s).


2. Depending on the alarm, refer to related corrective
actions.
3. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

2-6

Recognizing Equipment Degradation or Failure

Transponder Degradation Alarms


Overview

...................................................................................................................................................................................................................................

Transponder Degradation Alarms


Overview
Purpose

This chapter lists and describes

all the alarms which warn a transponder degradation,


associated trouble shooting tasks to be performed to clear such alarms.

Contents
OPD (Output Power Degraded)

2-8

TD (Transmitter Degraded)

2-9

WD (Wavelength Deviation)

2-10

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-7
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Equipment Degradation or Failure

Transponder Degradation Alarms


OPD (Output Power Degraded)

...................................................................................................................................................................................................................................

OPD (Output Power Degraded)


OPD (Output Power Degraded)
Description

The measured output power of transponder board is out


of range (+/- 1 dB) compared with the configured target
output power.

Probable Cause

There is an internal problem on the board which raises


the alarm.

Related Alarms

Related equipment alarm(s) may be raised if hardware


problem.
Corrective Actions

On-Site Intervention Required

Yes.

Actions

1. Change the faulty board.


If related alarms are raised, you need to perform
board replacement immediately.
If no related alarms, you can change the faulty
board during a planned maintenance period.
2. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

2-8

Recognizing Equipment Degradation or Failure

Transponder Degradation Alarms


TD (Transmitter Degraded)

...................................................................................................................................................................................................................................

TD (Transmitter Degraded)
TD (Transmitter Degraded)
Description

The transmitter module is degraded in the following


circumstances:
On the User/Client side:

The output power is 3 dB +/- 0.5 dB lower than the


begin of life value.

The laser temperature exceeds by +/- 2.5 C the


begin of life value.

On the Line side:

Probable Cause

The modulator output power is lower than


1dBm+/-1dB.

The laser module temperature is greater than 80 C.

In case of board plugging

The board initialization is not complete. The alarm


should disappear once the initialization is finished.

In case of normal operation

The transmitter module of the board is degraded.


Related Alarms

one.
Corrective Actions

On-Site Intervention Required

Yes, in certain circumstances.

Actions

In case of board plugging context:

1. Wait until the end of board initialization.


2. Unplug and plug again the board to re-initialize it.
3. If the error persists, replace the board.
4. End.
In case of normal operation:

1. Replace the board during a planned maintenance


period.
2. End.

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-9
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Equipment Degradation or Failure

Transponder Degradation Alarms


WD (Wavelength Deviation)

...................................................................................................................................................................................................................................

WD (Wavelength Deviation)
WD (Wavelength Deviation)
Description

The wavelength is out of range (+/- 1.5 GHz).

Probable Cause

In case of board plugging:


The board initialization is not complete. The alarm
should disappear when initialization is complete.

In case of normal operations:


The optical module has failed and cannot align the
wavelength with the configured value.

Related Alarms

o.
Corrective Actions

On-Site Intervention Required

Yes.

Actions

In case of board plugging context:

1. Wait until the end of board initialization.


2. Unplug and plug again the board to re-initialize it.
3. If the error persists, replace the board.
4. End.
In case of normal operation:

1. Replace the board during a planned maintenance


period.
2. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

2-10

Recognizing Equipment Degradation or Failure

Amplifier Degradation Alarm


Overview

...................................................................................................................................................................................................................................

Amplifier Degradation Alarm


Overview
Purpose

This chapter lists and describes

all the alarms which warn a LOFA degradation,


associated trouble shooting tasks to be performed to clear such alarms.

Contents
TD (Transmitter Degraded)

2-12

HVCSP (Heating or ventilation or Cooling System Problem)

2-13

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-11
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

Recognizing Equipment Degradation or Failure

Amplifier Degradation Alarm


TD (Transmitter Degraded)

...................................................................................................................................................................................................................................

TD (Transmitter Degraded)
TD (Transmitter Degraded)
Description

Probable Cause

The transmitter module is degraded in the following


circumstances:

The pump laser temperature is out of acceptable


range (less than 15 C or greater than 35 C), or

Pump current has reached its maximum value,


indicating pump end of life.

In case of board plugging

The board initialization is not complete. The alarm


should disappear once the initialization is finished.

In case of normal operation

The pump module of the board is degraded.


Related Alarms

one.
Corrective Actions

On-Site Intervention Required

Yes, in certain circumstances.

Actions

In case of board plugging context:

1. Wait until the end of board initialization.


2. Unplug and plug again the board to re-initialize it.
3. If the error persists, replace the board.
4. End.
In case of normal operation:

1. Replace the board during a planned maintenance


period.
2. End.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

2-12

Recognizing Equipment Degradation or Failure

Amplifier Degradation Alarm


HVCSP (Heating or ventilation or Cooling System Problem)

...................................................................................................................................................................................................................................

HVCSP (Heating or ventilation or Cooling System Problem)


HVCSP (Heating or ventilation or Cooling System Problem)
Description

An internal component which regulates the erbium


doped fiber temperature does not work in normal
conditions.

Probable Cause

See Description.

Related Alarms

one.
Corrective Actions

On-Site Intervention Required

Yes, in certain circumstances.

Actions

1. Contact Alcatel-Lucent Support Team for expertise


because this alarm does not necessarily impact the
transmission.
2. End.

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
2-13
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

3OFA Input Signal


L
Degradation Threshold
Management

Overview
Purpose

This chapter describes the LOFA degradation threshold management.


Contents
IPD Threshold Table Management

3-2

About IPD Alarm Threshold

3-2

IPD Threshold Configuration Guidelines

3-4

Displaying Board Alarm Threshold

3-5

Creating Alarm Threshold Tables

3-6

Assigning an Alarm Threshold to a Board

3-8

Modifying Alarm Threshold Tables

3-9

Deleting Alarm Threshold Tables

3-11

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
3-1
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Overview

...................................................................................................................................................................................................................................

IPD Threshold Table Management


Overview
Purpose

For LOFA boards, an IPD (Input Power Degradation) alarm threshold enables to define
the triggering point of an IPD alarm.
A LOFA board is assigned with a default threshold table which holds the alarm threshold
values.
To be able to create a specific IPD threshold table and to assign it to a LOFA board with
specific threshold values, you must:
1. Select the default threshold table.
2. Clone the selected table and save it with a specific name.
3. Assign the threshold table to the required board.
4. End.
Contents
About IPD Alarm Threshold

3-2

IPD Threshold Configuration Guidelines

3-4

Displaying Board Alarm Threshold

3-5

Creating Alarm Threshold Tables

3-6

Assigning an Alarm Threshold to a Board

3-8

Modifying Alarm Threshold Tables

3-9

Deleting Alarm Threshold Tables

3-11

About IPD Alarm Threshold


You can set and customize IPD threshold values which will trigger the Input Power
Degraded alarm, depending on the values you will have entered as shown in the
following figure.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

3-2

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


About IPD Alarm Threshold

...................................................................................................................................................................................................................................

Figure 3-1 Power Alarm Raise Logic

IPD Threshold Values

The following table displays the threshold values you can assign to the IPD threshold.
Table 3-1

IPD Alarm Threshold Values

IPD Alarm Threshold

Default Value

Range

Step

1st Stage Input Power Degradation (High


Threshold) (in dBm)

+5 dBm

-42 dBm to +9
dBm

0.5 dBm

1st Stage Input Power Degradation (Low


Threshold) (in dBm)

-35 dBm

-42 dBm to +9
dBm

0.5 dBm

2nd Stage Input Power Degradation


(High Threshold) (in dBm)

+17.5 dBm

-29 dBm to
+17.5 dBm

0.5 dBm

2nd Stage Input Power Degradation (Low


Threshold) (in dBm)

-29 dBm

-29 dBm to
+17.5 dBm

0.5 dBm

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
3-3
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


IPD Threshold Configuration Guidelines

...................................................................................................................................................................................................................................

IPD Threshold Configuration Guidelines


Recommendations

The following table shows how to determine low and high threshold values that
Alcatel-Lucent recommends to set

after commissioning or,


after network upgrade.

For Threshold Type...

Threshold Value is Equal To...

Low

Measured power at line amplifier input - 3 dB.

High

Measured power at line amplifier input + 3 dB.

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

3-4

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Displaying Board Alarm Threshold

...................................................................................................................................................................................................................................

Displaying Board Alarm Threshold


Purpose

Use this procedure to display board alarm thresholds.


Before you begin

The required board view is displayed.


How to display board alarm threshold

To display board alarm thresholds, perform the following steps:


...................................................................................................................................................................................................

Select Board>Alarm Threshold Configuration


Result: The Alarm Threshold Configuration window is displayed and lists the

existing alarm threshold tables for the selected board.


...................................................................................................................................................................................................

From the Threshold table list, select an entry and click View.
Result: The Alarm Threshold view window is displayed.
...................................................................................................................................................................................................

Click Cancel to close the window.


...................................................................................................................................................................................................

Click Close to finish.


E...................................................................................................................................................................................................
N D O F S T E P S

See Also

About IPD Alarm Threshold (p. 3-2)

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
3-5
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Creating Alarm Threshold Tables

...................................................................................................................................................................................................................................

Creating Alarm Threshold Tables


Purpose

Use this procedure to create alarm threshold tables.


Before you begin

The required board view is displayed.


How to create alarm threshold tables

To create alarm threshold tables, perform the following steps:


...................................................................................................................................................................................................

Select Board>Alarm Threshold Configuration


Result: The Alarm Threshold Configuration window is displayed and lists the

existing alarm threshold tables.


...................................................................................................................................................................................................

From the Threshold table list, select an entry and click Clone.
Result: The Alarm threshold table cloning window is displayed.
...................................................................................................................................................................................................

In Table name field, enter a name for the new alarm threshold table.
...................................................................................................................................................................................................

For each of the thresholds, select the required value.


...................................................................................................................................................................................................

Click Clone.
...................................................................................................................................................................................................

The new alarm threshold table appears in the Threshold Table list.
...................................................................................................................................................................................................

From the list, select the new table.


...................................................................................................................................................................................................

Click Apply.
...................................................................................................................................................................................................

The new table is assigned to the selected board.


...................................................................................................................................................................................................

10

Click Close to finish.


E...................................................................................................................................................................................................
N D O F S T E P S

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

3-6

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Creating Alarm Threshold Tables

...................................................................................................................................................................................................................................

See Also

About IPD Alarm Threshold (p. 3-2)

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
3-7
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Assigning an Alarm Threshold to a Board

...................................................................................................................................................................................................................................

Assigning an Alarm Threshold to a Board


Purpose

Use this procedure to assign an alarm threshold to a board.


Before you begin

The required board view is displayed.


How to assign an alarm threshold to a board

To assign an alarm threshold to a board, perform the following steps:


...................................................................................................................................................................................................

Select Board>Alarm Threshold Configuration


Result: The Alarm Threshold Configuration window is displayed and lists the

existing alarm threshold tables.


...................................................................................................................................................................................................

From the Threshold table list, select an entry and click Apply.
Result: The selected table is assigned to the selected board.
...................................................................................................................................................................................................

Click Close to finish.


EN

O F

S T E P S

...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

3-8

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Modifying Alarm Threshold Tables

...................................................................................................................................................................................................................................

Modifying Alarm Threshold Tables


Purpose

Use this procedure to modify alarm threshold tables,


Before you begin

The required board view is displayed.


How to modify alarm threshold tables

To modify alarm threshold tables, perform the following steps:


...................................................................................................................................................................................................

Select Board>Alarm Threshold Configuration


Result: The Alarm Threshold Configuration window is displayed and lists the

existing alarm threshold tables.


...................................................................................................................................................................................................

From the Threshold table list, select an entry and click Modify.
Result: The Alarm threshold table modification window is displayed.
...................................................................................................................................................................................................

If necessary, in Table name field, enter a new for the threshold table.
...................................................................................................................................................................................................

For the required thresholds, select a new value.


...................................................................................................................................................................................................

Click Apply.
Result: The new alarm threshold table appears in the Threshold Table list.
...................................................................................................................................................................................................

From the list, select the new table.


Result: Click Apply.
...................................................................................................................................................................................................

The modified table is assigned to the selected board.


...................................................................................................................................................................................................

Click Close to finish.


E...................................................................................................................................................................................................
N D O F S T E P S

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
3-9
Issue 1 February 2010
Solely for authorized persons having a need to know
Proprietary Use pursuant to Company instruction

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Modifying Alarm Threshold Tables

...................................................................................................................................................................................................................................

See Also

About IPD Alarm Threshold (p. 3-2)

...................................................................................................................................................................................................................................
Alcatel-Lucent Confidential
3AL 94322 FAAA
Solely for authorized persons having a need to know
Issue 1 February 2010
Proprietary Use pursuant to Company instruction

3-10

LOFA Input Signal Degradation Threshold Management

IPD Threshold Table Management


Deleting Alarm Threshold Tables

...................................................................................................................................................................................................................................

Deleting Alarm Threshold Tables


Purpose

Use this procedure to delete alarm threshold tables.


Before you begin

The required board view is displayed.


The alarm threshold table to delete is not a default one.

The alarm threshold table to delete is not assigned to any boards.

How to delete alarm threshold tables

To delete alarm threshold tables, perform the following steps:


...................................................................................................................................................................................................

Select Board>Alarm Threshold Configuration


Result: The Alarm Threshold Configuration window is displayed and lists the

existing alarm threshold tables.


...................................................................................................................................................................................................

From the Threshold table list, select an entry and click Delete.
...................................................................................................................................................................................................

Click Delete to confirm.


...................................................................................................................................................................................................

Click Close to finish.


END

O F

S T E P S

...................................................................................................................................................................................................

...................................................................................................................................................................................................................................
3AL 94322 FAAA
Alcatel-Lucent Confidential
3-11
Issue 1 February 2010
Solely for authorized persons having a need to know