CONTROL VALVE SIZING

Based on Masonelian Method January '94

Nomenclature P1 P2 Delta P Pv G

Upstream Pressure Downstream Pressure P1 - P2 Vapour Pressure Gas s.g. at S.C.

Cf Cv del Ps Pc Gf

Critical Flow Factor Valve Flow Coefficient Pressure drop for critical flow calculations Critical Pressure Gas s.g. at flowing temperature

Liquids
Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi) Fluid s.g.

XXXX 76997 64294 64294

CV-XXX

LIQUID - Calc CV Cooler water TT heater water valve(sum) TT heater water valve(win)

245.46 56 485 39

404.95 40 40 40

19 5 10 10

0.5 1 1 1

XXXX

CV-XXX

LIQUID - Calc Delta P

48

45

XXXX

CV-XXX

LIQUID - Calc flow

48

45

INSTRUCTIONS 1 Press F5 and select whichever calculation you want to use (for example LIQUID-CalcCV) 2 Pick Edit Copy 3 Move the cursor to the line you want to copy to in the column under Job No. 4 Pick Edit Insert Paste (it will ask you if you want to Shift Cells Down - pick OK) 5 Enter values in all the cells with yellow backgrounds - other values will be calculated. FOR MORE INFO PRESS F5 and SELECT NOMENCLATURE

Page 1

97580531.xlsx

al flow calculations

Fluid Pv (psia)

Fluid Pc (psia)

Valve Cf

Check for Critical Flow Condition (cavitation or flashing) Flow del Ps Critical? Cv (psi)

Notes

48 15.64 3 3

615.76 3206 3206 3206

0.75 0.75 1 1

NO NO NO NO

39.8 25.0 153.4 12.3

407.74 39.35 39.07 39.07

15.64

3206

0.75

NO

21.5

44.35

15.64

3206

0.75

NO

21.5

44.35

UID-CalcCV)

Page 2

97580531.xlsx

Saturated Steam
Job No 67194 67194 63593 67194 76997 XXXXX XXXXX Tag No Service Flow lb/hr 25600 106000 2590 15000 600 1000 1000 P1 Delta P (psia) (psi) 19.7 5 19.7 5 85 37 20 5 85 5 85 85 10 10

CANADA SALT OUTLET ADM OUTLET CV-105/205 team to water injector heater S Steam line purge ster Sterlilizer steam CV-XXX CV-XXX SAT'D STEAM - Calc Cv SAT'D STEAM - Calc Delta P

XXXXX 74896 76397 XXXXX

CV-XXX

SAT'D STEAM - Calc Flow Steam to kettles PV804A-C Booster motive steam, 10" PV804D Booster motive steam, 4"

1000 6492 116563 22514

85 150 150 150

10 35 1 1

Page 3

97580531.xlsx

Check for Critical Flow Condition Valve Cf 0.65 0.65 0.75 0.75 0.75 0.75 0.75 Cv 1092.5 4523.5 22.2 539.9 9.9 11.9 11.9 Flow Critical? YES YES YES NO NO NO NO P2 (psia) 14.7 14.7 48 15 80 75 75 170

Notes

0.75 0.75 0.75 0.75

11.9 32.1 3210 620

NO NO NO NO

75 115 149 149

Page 4

97580531.xlsx

Gases
c Job No Tag No Service Flow lb/hr Gas M.W.

XXXXX XXXXX XXXXX -1601.28 63593 XXXXX

CV-XXX CV-XXX CV-XXX Air CV-XXX

GASES - Calc Cv GASES - Calc Delta P GASES - Calc Delta P Cylinder lift GASES - Calc Flow

15000 1000 1000 156 997

18 18 18 29 18

Page 5

97580531.xlsx

Temp (deg F)

P1 (psia)

Delta P (psi)

Valve Cf

Check for Critical Flow Condition at s.c.=32F, 14.7 psia Cv Flow Gas s.g. Gf P2 Critical? G (psia)

250 316 316 70 316

20 85 85 85 85

5 10 10 5 10

0.75 0.75 0.75 0.75 0.75

522.3 12.0 12.0 1.7 12

NO NO NO NO NO

0.62 0.62 0.62 1 0.62

0.45 0.42 0.42 0.98 0.42

15 75 75 80 75

Page 6

97580531.xlsx

Superheated Steam
Notes b c Job No Tag No

XXXXX 170 -1610.31 170 -1610.31 XXXXX XXXXX XXXXX XXXXX

CV-XXX CV-XXX CV-XXX CV-XXX CV-XXX

Page 7

97580531.xlsx

eated Steam
Service Flow lb/hr P1 (psia) Delta P (psi) Valve Cf Superheat (deg F)

SUPERHTD STEAM - Calc Cv SUPERHTD STEAM - Calc Delta P SUPERHTD STEAM - Calc Delta P SUPERHTD STEAM - Calc Flow SUPERHTD STEAM - Calc Flow

1000 1000 1000 1000 1000

85 85 85 85 85

10 10 10 10 10

0.75 0.75 0.75 0.75 0.75

0 0 0 0 0

Page 8

97580531.xlsx

Check for Critical Flow Condition Cv Flow Critical? P2 (psia)

Notes

11.9 11.9 11.9 11.9 11.9

NO NO NO NO NO

75 75 75 75 75 170 -1601.28 170 -1601.28

Page 9

97580531.xlsx

Laminar Flow of Liquids


Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi) Fluid s.g.

XXXX XXXX

CV-XXX CV-XXX

LAMINAR LIQUID - Calc CV LAMINAR LIQUID - Calc Delta P

48 48

45 45

5 5

1 1

XXXX

CV-XXX

LAMINAR LIQUID - Calc flow

48

45

Page 10

97580531.xlsx

Fluid Fluid Pv Fluid Pc Visc (cp) (psia) (psia)

Valve Cf

Check for Critical Flow Condition (cavitation or flashing) Required Turbulent Laminar Cv Cv Cv

del Ps (psi)

Notes

1000 1000

15.64 15.64

3206 3206

0.75 Err:522

Err:522

32.5 32.5

44.35 44.35

Err:522

0.75 CV goes in Laminar Col

1000

15.64

3206

0.75 CV goes in Laminar Col

32.5

44.35

Page 11

Liquids
Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi)

XXXX

CV-XXX

LIQUID - Calc CV for C3 pipeline

245.46

404.95

19

Fluid s.g.

Fluid Pv (psia)

Fluid Pc (psia)

Valve Cf

Check for Critical Flow Condition (cavitation or flashing) Flow del Ps Critical? Cv (psi)

Notes

0.5

48

615.76

0.75

NO

39.8

407.74

Вам также может понравиться