Вы находитесь на странице: 1из 46

SHANGHAI XINHUA CONTROL TECHNOLOGY (GROUP) CO.

,LTD Brief Introduction

PART

About XINHUA

1. Headquarters

Pioneer with several sts. in automation for Power Stations


In 1997

Since 2006 Xinhua XDC 800 has been brought into the market and won widely application in the fields.

1st integrated DCS for


In 1996 retrofitting projects of 125MW,200MW units

1st home-made DCS for


In 1990 units ranging from 125MW, 200MW, 300MW to 600MW

1st home-made DEH for


300MW units

More than 1500 clients have used Xinhua DCS.

2. Engineering Center 3. R & D Center 4. Training Center


The R&D center excels in technique studying, developing, equipment remodeling, repair and maintenance and technical consultation.

XINHUA GROUP
Office Building in Shanghai Zizhu Hi-Tech Industrial Development Zone

XINHUA GROUP
Office Building in Shanghai Zizhu Hi-Tech Industrial Development Zone

XINHUA GROUP
Office Building in Shanghai Zizhu Hi-Tech Industrial Development Zone

2. Engineering Center

3. R & D Center
The R&D center excels in technique studying, developing, equipment remodeling, repair and maintenance and technical consultation.

DCS Milestone
XDC800 P600 XDPS-400+

On Process

XDPS-400 DAS-300 DAS-100

Timeline
1988 1992 1997 2003 2005 2006 2008

4. Manufacturing Center of Electronic Equipment

Manufacturing Center of Electronic Equipment

Manufacturing Center of Electronic Equipment

Manufacturing Center of Electronic Equipment

Manufacturing Center of Electronic Equipment

Spare Parts Warehouse


A well-arranged spare parts warehouse could ensure a timely delivery upon customers requests.

5. Assembly Workshop of Hydraulic Equipment


3300 m2 clean and orderly assembly workshop is a precondition for reliable products.

Turbine High Pressure Fire Resistant Fluid EH system

EH oil supply unit

Emergency Trip System

Hydraulic Actuator of EH System Turbine Bypass Hydraulic Pressure Control System

EH oil regenerator

Accumulators

6. QA & QC Center
All products will be strictly tested and debugged to ensure the quality.

6. QA & QC Center
All material will be undergone strict inspection before entering the warehouse.

6. QA & QC Center

The workers are assembling the cylinders.

Project Achievements
1. DCS
1.1 DCS system 1.1.1 600MW Unit 1.1.2 300MW Unit 1.1.3 200MW Unit 1.1.4 125MW Unit 1.1.5 100MW Unit 1.1.6 Circulating Fluidized Bed Boiler 1.1.7 Small Unit DCS 1.1.8 XDPS-100 XDPS 300 1.2 DCS for Complete Imported sets

800 Sets
759 Sets 6 Sets 116 Sets 60 Sets 107 Sets 44 Sets 146 Sets 247 Sets 31 Sets 41 Sets

2. Turbine Control System with High Pressure Fire-Resistant Oil (DEH, EH) 560 Sets
2.1 600MW Unit DEH, MEH, EH 2.2 300MW Unit DEH, MEH, BPS, EH 2.3 300MW Unit DEH Nuclear Power 2.4 200MW Unit DEH, EH 2.5 125MW and lower Unit DEH 19 Sets 222 Sets 1 Set 140 Sets 178 Sets

Project Achievements
3. Turbine Control System with Pure Electric Adjustment for Low Pressure Turbine Oil (DEH) 80 Sets 4. 300MW/600MW Unit Feed Water Pump Turbine MEH 308 Sets 5. By-pass Control System (BPS) 80 Sets 6. Emergency Trip System (ETS) 145 Sets 7. MIS, SIS 48 Sets 8Network Control System (NCS) 35 Sets 9Electrical Comprehensive Monitor System XECS2000 1 Set 10 Hydropower Station 2 Sets 11 Power Plant Auxiliary System 60 Sets 12 Power Plant Desulphurization System 49 Sets 13 Power Plant Simulation System 29 Sets 14 Turbine Supervisory Instrumentation (TSI) 20 Sets 15 Power Plant Fault Recorder 17 Sets 16 Upgrade for Import System 36 Sets 17 Export Projects 40 Sets

PART

XINHUA XDC 800

For All Power Stations


1. DEH

4. GSS RTC
5. Auxiliary System CET GFR GGR GPV GTH

2. ATC

3. ETS

7. Others

XDC 800

XDC800 Hardware

Switch

XDC800 Hardware
Base & connector
Dimension 300mm X 112mm

IO base

Base connector

Base fastener

XDC800 Hardware Base

37 core and screwtype terminal base

Double-screwtype terminal base

Communication module base

Screw and 37 cores terminal base

Double 37 cores terminal base

Expansion base

XDC800 Hardware Module & Base

Screw terminal base and modules

37 cores base and module

XDC800 Hardware Communication module Module

Base

Redundant

XDC800 Hardware
IO Module

AITC

AImA/V

AIRTD

AO

DI

DO

XDC800 Hardware
Specific IO Module

Circuit control module

Logic protection module

PI

PO

Speed-testing module

Valve control module

XDC800 Hardware
Terminal Board

Relay terminal board

Circuit control terminal board

1 out of 2 Logic protection card terminal board

Valve control terminal board

Speed testing card

2 out of 3 Logic protection card

XDC800

DC power supply modules Network switches XDC800 XCU controllers Communication modules I/O Modules Control cabinets

XDC 800
HMI

Ethernet Redundant XCU

Redundant XCU
RS485(MODBUS)

RS485(MODBUS)

Redundant XCC
I/O I/O

IO Modules

Field Data

XDC800

Strengths of XDC800 I
Network Architecture
Real-time Net (RTNET) and InfoNet are designed as two independent networks to ensure the stability of RTNET.

Strengths of XDC800 Strength II


No server between the XCU and HMI is needed. The Bottleneck of SS is avoided.

Strength of XDC800 III Database


Redundant

Global DB

Global DB

SubDB

Data Synchronization Redundant Switchover

Strengths of XDC800 IV
Virtual XCU

1.Convinent to conduct software simulation and configuration

RS485(MODBUS)

RS485(MODBUS)

2.Convinent to achieve DCS mini Specification and application

I/O

I/O

Strength of XDC800 V
Modularization and Virtulazation Configuration Software

Rich control algorithm 9 Categories 100 + function blocks

Strength of XDC800 VI
Convenient Graphic Maker Support self-defining of FunBlock Customers can generate complex fun blocks using exiting ones.

3D pipe drawing Gradient Color setting Supporting web function

XDC800
Software onXDC

Program

Graphic Display

Self-Test

Standard Display

Statemen t Making

History Data

XCU Configur ation

Real-time Interface

Data

Network Interface

Windows 2000/XP