Power analyzer
Measure
Harmonics measuring up to the 50 th in current and voltage. Option for measuring in Low and Medium Voltage systems. Varied Measuring range permitted (110, 520, 866 Vph-ph)) Double scale kW / MW Current reading using external transformers .../5A or /1A (insulated inputs, according to type). Recording of max and minimum dates
Communications
ETHERNET Modbus TCP/RTU, and Modbus TCP/IP RS-485 with Modbus RTU, Modbus TCP, Metasys N2 Compatible with the Power Studio / Scada system RS-485 communications MODBUS - RTU Up to 3 expansion communications channels
Display fearutes
Incorrect connection detection. Internal clock for setting and for 12 hourly tariffs (TOU). System of visualization by menus Direct access to the measurement screens, setup, etc. Access to summary of the system by function key in any screen (PT, CT, registry, etc.). Menus in different languages Big LCD display Allows selection of default page
Communications (2 ports)
Three-phase 50...60 Hz
Disturbance detection
Multitarariff (9 tariffs)
Analogue outputs
Analogue inputs
Digital inputs
Relay output
Wave form
Protocol
Type
Code
COMPACT EQUIPMENTS (M-CVMk2 + Display) 0,5 0,2 RS-485 RS-485 MEASUREMENT EQUIPMENTS 0,5 0,2 RS-485 RS-485 Modbus/RTU Modbus/RTU M-CVMk2-ITF-405 M-CVMk2-ITF-402 M54410 M54412 Modbus/RTU Modbus/RTU CVMk2-ITF-405 CVMk2-ITF-402 M54400 M54402
PARAMETERS
Phase-neutral voltage Phase-phase voltage Current Frequency Active power Inductive reactive powera Capacitive reactive power Apparent power Power factor cos Power demand Neutral current Earth leakage current Harmonic decomposition, U and I (50th) Harmonic Measuring in voltage Harmonic measuring in current kWh (consumed and generated)(*) kvarh L (consumed and generated)(*) kvarh C (consumed and generated)(*) kVAh (consumed and generated)(*) Flicker (*) For every tariff and total and much more...
UNIT
V V A Hz kW kvar L kvar C kVA PF cos Pd IN If
L1
L2
L3
III
optional
FEATURES
Power supply circuit (*) Consumption Frequency Measuring circuit Rated voltage Frequency Voltage circuit consumption Rated current Permanent overload Class Power Energy 0,5 % ( 1 digits) / 0,2 % ( 1 digits) 0,5 % ( 1 digits) / 0,2 % ( 1 digits) 300 V ac (phase-neutral)/ 520 V ac (phase-phase) 45...65 Hz 0,9 VA .../5 A / .../1 A 1,2 In 85 ... 265 V ac 5 VA (without display & expansion cards) 50 / 60 Hz Assembly features Connection Type of casing Protection: assembled equipment (front) unassembled equipment (side) Dimensions Weight Environmental conditions Operating temperature Humidity Safety -10 ... +50 C 5 ... 95 % (without condensation) Category III-300 V AC. 520 V AC. EN 61010. Electrical shock protection by double insulation class II IEC 664, VDE 0110, IEC 801, UL 94, IEC 348, IEC 571-1, EN 61010-1, EN 50081-1, EN 50082-1 IEC 61000-4-30 Class B Pluggable board Self extinguishing V0 plastic IP 54 IP 31 144 x 144 mm 0,6 kg
(*) Other power supplies and measurings on request (please see price list).
Standards
Accessories
5A
Vial Sant Jordi s/n 08232 Viladecavalls Barcelona (Spain) Tel. (+34) 93 745 29 00 Fax: (+34) 93 745 29 14 e-mail: central@circutor.es web: www.circutor.com