A WORLD POWER IN CABLE SUPPLY

THE CABLE
A N D AC C E S S O RY
C ATA LO G U E 2 0 1 1

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS

We are fortunate to have a very


experienced and dedicated team of
people who are able to assist and
advise. Additionally our policy of
continuing investment in the best
available technology, warehousing,
handling and measuring equipment
and delivery vehicles enables us to
guarantee all our customers an
extremely high quality service.
Enquiries are welcome from customers worldwide. Our export service is efficient
and reliable with the ability to ship by air or sea freight to any destination.

Please feel free to contact the distribution centre


of your choice for an immediate, professional
and trouble free service.
Middlesbrough

01642 241133

Bristol

01179 382222

Glasgow

0141 6465000

Milton Keynes

01908 221414

London

0208 3114141

Newcastle

0191 2633363

Warrington

01925 655383

CLEVELAND CABLE COMPANY

As is illustrated within our catalogue, we stock a


comprehensive range of cables for every
conceivable application. All types shown are
considered as standard items to our range and are
always available for immediate delivery. Our stocks
are extremely large and unrivalled in the industry.

CLEVELAND CABLE COMPANY

CLEVELAND CABLE COMPANY


Cleveland Cable Company, established in 1978, is
undoubtedly the foremost distributor of electrical
cables in Great Britain and possibly Europe.

The Head Office and principal stocking location is located at Middlesbrough in the
North East of England. This site covers an area of twelve acres and includes over
160,000 square feet of warehousing. Additionally there are regional depots at
Bristol, Glasgow, London, Milton Keynes, Newcastle and Warrington. Each location
holds comprehensive stocks and is equipped with the most modern handling and
measuring equipment. Deliveries are made by our own fleet of purpose-designed
vehicles, all of which are fitted with hydraulic lifting equipment for safe offloading
onsite and also efficient collection of empty drums.

MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD

LAND
ACQUIRED FOR FUTURE
DEVELOPMENT

MIDDLESBROUGH HEAD OFFICE - WAREHOUSES AND STOCKYARD

GLAND SELECTION GUIDELINES


There are many factors to be considered when selecting
cable glands for industrial installations. Neglecting to
give due attention to these factors could cause
unnecessary difficulties at a crucial point in time where
most inconvenience and expense can result. It is most
desirable to avoid discovering that, once all other
equipment is on site or installed, the glands have not
been ordered or are the wrong size or type.
Good practice would be to allocate some planning and
preparation time to cable gland selection. This will help
avoid the possible disruption which could result at a
critical point of the installation process. In the event of a
project schedule of cables being available Cleveland
Cable Company are happy to offer a gland selection and
sizing service. Please contact any of our depots for
further information or assistance.
Here is a summary of some aspects to carefully consider
when selecting cable glands.
Identify the type of cable to be used.
Check the construction, size and material properties
of the cable.
Check the type and material of the cable armour (*)
Check the short circuit fault current rating of the
cable armour (**)
Check the actual diameter of the inner bedding
(where present) against this catalogue.
Check the actual diameter of the lead covering (where
present) against this catalogue.
Check the actual size of the overall cable diameter
against this catalogue.
Check the size and type or armour or braid (where
present) against this catalogue.
Check any special environmental requirements in
relation to corrosion protection.
Check the material of the mating electrical enclosures
to eliminate dis-similar metals.
Consider whether any protective plating is required to
be applied to the cable gland.

Check the type and size of the cable entry hole in the
mating electrical equipment.
Check the ingress protection rating of the electrical
equipment or site standard.
Check whether a single or double seal cable gland
is required.
Check whether an entry thread seal is required for
IP66 (or IP67/IP68) conditions.
Check whether fixing accessories such as locknuts
and serrated washers are required.
Check whether earth tags are required. (**)
Check whether shrouds are required.
Select a corresponding cable gland type from
this catalogue.
For installations in Hazardous Areas, special
considerations should be taken into account to ensure
compliance with national or international codes
of practice.
Check whether a thread conversion adaptor or
reducer is required to make the installation.
Select corresponding adaptors or reducers from
this catalogue.
Check whether any stopper plugs are required to close
unused cable entries.
Select corresponding stopper plugs from
this catalogue.
Note (*): If the cable armour is of a non standard
material, i.e. Aluminium Wire Armour, it may be
necessary to consider an alternative cable gland material,
e.g. Aluminium.
Note (**): For certain medium voltage and high voltage
cables where the fault current carrying capacity of the
cable armour is greater that that of the standard earth
tag it may be necessary to consider a cable gland utilising
the a heavy Cast Integral Earth Lug (CIEL) option which
can be identified in the body of this catalogue.

6491X (HO7V-R) PVC insulated wiring, 1.5mm2 630mm2 ............................................................14


Bare copper strand, soft drawn to BS6360/81, 6mm2 400mm2 ................................................14
6181Y PVC insulated, PVC sheathed surface wiring, 1.0mm2 120mm2..................................15
624*Y PVC insulated, PVC sheathed surface wiring, 1mm2 16mm2 ........................................15
BS5467 Mains & control, XLPE, PVC SWA, PVC, 1.5mm2 16mm2
including multicores..........................................................................................................................................16
BS5467 Mains, XLPE, PVC, SWA, PVC, copper conductors, 25mm2 400mm2 ........................17
BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 4mm2 16mm2 ..........................18
BS5467 Mains, XLPE, PVC, SWA, MDPE, copper conductors 25mm2 400mm2 ......................19
BS5467 Mains, XLPE, PVC, SWA, PVC, aluminium conductors, 25mm2 300mm2 ................20
BS7889 Mains, single core, XLPE, PVC, non-armoured, 50mm2 1000mm2 ............................21
BS5467 Mains, single core, XLPE, PVC, aluminium wire armoured, PVC,
50mm2 1000mm2 ..........................................................................................................................................22
Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% Conductivity in
armour, 10mm2 300mm2 ............................................................................................................................23
EEMUA 133 Multicore, XLPE, lead sheathed, PVC, SWA, PVC, Control cable for
petro-chemical industries, 1.5mm2 4mm2 ........................................................................................24
EEMUA 133 Mains, XLPE, lead sheathed, PVC,SWA, PVC, for petro-chemical
industries, 1.5mm2 16mm2 ........................................................................................................................25
EEMUA 133 Mains, XLPE, lead sheathed, PVC, SWA, PVC, for petro-chemical
industries, 25mm2 300mm2 ......................................................................................................................26
Cathodic Protection Cables. XLPE, PVC, and XLPE, PVC, SWA, PVC, 6mm2 185mm2 ..........27
Concentric, split & straight, single phase service cable, 4mm2 35mm2 ................................28

SECTION 2 3300V Mains Cable


BS5467 Mains, single core XLPE, PVC, aluminium wire armoured, PVC, 3300V,
120mm2 630mm2 ..........................................................................................................................................30
BS5467 Mains three core, XLPE, PVC, SWA, PVC, 3300V, 16mm2 400mm2 ............................31
Mines & Quarries Mains, XLPE, PVC, SWA, PVC, with 60% conductivity in armour,
3300V, 16mm2 300mm2 ..............................................................................................................................32
EEMUA 133 Mains, XLPE, Lead sheathed, PVC, SWA, PVC, for petro-chemical
industries, 3300V, 25mm2 300mm2 ........................................................................................................33

SECTION 3 LSZH Fixed Wiring & Mains Cables


6491B (H07Z-R) LSZH insulated wiring, 1.5mm2 630mm2 ..........................................................36
6181B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm2 35mm2 ..............................37
624*B XLPE insulated, LSZH sheathed surface wiring 1.5mm2 16mm2 ..................................37
BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm2 16mm2
including multicores .........................................................................................................................................38
BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm2 400mm2 ............................................................39
BS6724 Mains, single core, XLPE, LSZH, 50mm2 1000mm2 ..........................................................40

CONTENTS

SECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables

CONTENTS

10

BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH,
50mm2 1000mm2 ..........................................................................................................................................41
BS8436 Protected fixed wiring cable, 1mm2 10mm2 ......................................................................42

SECTION 4 Medium Voltage 11000V & above


BS6622 Mains, single core, XLPE, CTS, PVC, aluminium wire armoured, PVC,
11000V, 50mm2 630mm .............................................................................................................................44
BS6622 Mains, three core, XLPE, CTS, PVC, SWA, PVC, 11000V, 25mm2 400mm2 ..............44
BS6622 Mains, three core, aluminium conductor XLPE, CTS, PVC, SWA, PVC,
11000V, 95mm2 300mm2 ..........................................................................................................................45
Triplex, BS7870, aluminium conductor XLPE, CTS,MDPE, 11000V, utility cable,
70mm2 300mm2 ..............................................................................................................................................46
Paper insulated, BS6480 Mains, three core, SWA, PVC, 11000V, 25mm2 400mm2 ............47
BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH,
11000V, 50mm2 630mm2 ............................................................................................................................48
BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000V,
35mm2 400mm2 ..............................................................................................................................................48
BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 22000V and 33000v,
95mm2 185mm2 ............................................................................................................................................49

SECTION 5 High voltage 33000v service and windfarm cables


BS7870 Mains, single core, aluminium conductors , XLPE, CWS, MDPE, 33000v
70mm2 630mm2 ..............................................................................................................................................52
BS7870 Mains, single core, copper conductors , XLPE, CWS, MDPE,
33000v 70mm2 630mm2 ............................................................................................................................53

SECTION 6 Fire Protection, Alarm & Security Cables


Mineral Insulated................................................................................................................................................56
BS5839/BS7629 Fire performance alarm and security cable,
1mm2 4mm2 ......................................................................................................................................................57
BS5839/BS7629 Enhanced fire performance alarm and
security cable 1.5mm2 4mm2 ....................................................................................................................58
BS6387 Fire performance single core cable, 1.5mm2 16mm2 ....................................................59
BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH,
fire resistant,1.5mm2 16mm2, including multicores ......................................................................60
BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant,
25mm2 400mm2 ..............................................................................................................................................61
BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant,
enhanced, 1.5mm2 16mm2, including multicores. ..........................................................................62
BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, enhanced,
25mm2 400mm2 .............................................................................................................................................63

11

PVC and LSZH flexible cables


218*Y (H03VV-F) PVC, PVC, 0.5mm2 0.75mm2....................................................................................66
318*Y (H05VV-F) PVC, PVC, 0.5mm2 2.5mm2 ......................................................................................66
309*Y Heat resisting PVC, PVC, 0.5mm2 2.5mm2 ..............................................................................67
Arctic grade low temperature flex, 1.5mm2 6mm2 ..........................................................................67
318*B (H05ZIZI-F) LSZH, LSZH, 0.75mm2 2.5mm2 ............................................................................68
YY Control cable, 0.75mm2 1.5mm2 ........................................................................................................69
YY Control cable, 2.5mm2 50mm2............................................................................................................70
SY Control cable, 0.75mm2 2.5mm2 ........................................................................................................71
SY Control cable, 4.0mm2 95mm2 ............................................................................................................72
CY Control cable, 0.5mm2 16mm2 ..........................................................................................................73
YY Control cable, LSZH, 0.75mm2 25mm2 ............................................................................................74
CY Control cable, LSZH, 0.75mm2 1.5mm2 ..........................................................................................74
Tri-rated and Bi-rated BS6231, switchgear and control panel wire,
0.5mm2 400mm2 ............................................................................................................................................75
6381Y PVC, PVC, 6mm2 400mm2..............................................................................................................76
2491B/6701B (H05Z-K), flexible conductor, LSZH insulated wiring,
1.5mm2 240mm2 ............................................................................................................................................76
Solar Energy Cables 1.5mm2 35mm2......................................................................................................77
Rubber flexible cables
BS6500 EPR insulated, CSP sheathed, flexible power & control, 0.75 2.5mm2 ..................78
BS7919 EPR insulated, CSP sheathed, flexible mains 4mm2 16mm2 ......................................79
BS7919 EPR insulated, CSP sheathed, flexible mains, 25mm2 630mm2 ................................80
HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm2 50mm2 ..............................81
HO7RN-F EPR insulated, PCP sheathed, flexible mains, 70mm2 630mm2 ............................82
380*P EPR insulated, copper braided screen, PCP sheathed, flexible mains,
1mm2 16mm2 ..................................................................................................................................................83
BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm2 2.5mm2 ............83
Coil lead BS6195 EPR, CSP, 0.5mm2 400mm2 .....................................................................................84
Welding cable, O361TQ EPR, CSP, 16mm2 185mm2 ........................................................................85
Flatform and silicon cables
Flatform cable, PVC, PVC, 1.5mm2 95mm2 ..........................................................................................86
Flatform cable, EPR, PCP, 1.5mm2 70mm2 ............................................................................................86
Silicon insulated, silicon sheathed, flexible cable, 0.75mm2 2.5mm2 ......................................87

SECTION 8 Instrumentation, Control & Communication Cables


BS5308 Control and instrumentation cable, non-armoured with collective screen,
0.5mm2 1.5mm2, part 1 and part 2.........................................................................................................90
BS5308 Control and instrumentation cable, non-armoured with individual and
collective screen, 0.5mm2 1.5mm2, part 1 and part 2 ....................................................................91
BS5308 Control and instrumentation cable, armoured with collective screen,
0.5mm2 2.5mm2, part 1 and part 2 ........................................................................................................92
BS5308 Control and instrumentation cable, armoured with individual and collective
screen, 0.5mm2 1.5mm2, part 1 and part 2 ........................................................................................93

CONTENTS

SECTION 7 Flexible Cables, PVC and Rubber

CONTENTS

12

BS5308 Control and instrumentation cable, lead sheathed, armoured with


collective screen, 0.75mm2 1.5mm2, part 1 and part 2..................................................................94
BS5308 Control and instrumentation cable, lead sheathed, armoured with
individual and collective screen, 0.75mm2 1.5mm2, part 1 and part 2 ..................................95
BS5308 part 1 core identification................................................................................................................96
BS5308 part 2 core identification................................................................................................................97
British Steel specification CES20 type 134, 0.75mm2 ........................................................................98
British Steel specification CES20 type 143, 0.75mm2 ........................................................................99
CW1308 telephone cable ............................................................................................................................100
Telephone cable to ENATS 09-6 standard..........................................................................101/102/103
Utility Industry PVC Control Cables, ENATS 09-6 2.5mm2 ..............................................................103
ENATS 09-6 section 3.6 core identification ..........................................................................................104
ENATS 09-6 section 4.5 core identification ..........................................................................................104
Petroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS3573 ................105
Defence standard screened cable type 61-12 ....................................................................................106
Defence standard 61-12 parts 4 & 5 core identification ...............................................................107
Thermocouple extension and compensating cable, 0.75mm2 ....................................................108
Thermocouple core identification ............................................................................................................109
Traffic signal cable, loop feeder cable and loop detector cable ........................................110/111

SECTION 9 Data Cables


Belden equivalents ..........................................................................................................................................114
Coaxial cables ....................................................................................................................................................114
Cat 5 data cables ..............................................................................................................................................114
Cat 6 data cables ..............................................................................................................................................114

SECTION 10 Railway Cables


Signalling cable types A1, A2, A3, B1 and B2, 0.75mm2 95mm2 ............................................116
Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm2 35mm2 ..............117
Train protection warning system cable..................................................................................................118
Point heater cable ............................................................................................................................................118
Axle counting cable ..............................................................................................................................119/120
Datalink cable ....................................................................................................................................................119
Copper trackside cable ..................................................................................................................................121
Power cables, 16mm2 95mm2 ................................................................................................................122
Trackfeeder cables, 150mm2 1000mm2 ..............................................................................................122

SECTION 11 Marine and Offshore Cables


EPR insulated, non-armoured shipwiring cable, 1.5mm2 6mm2 ..............................................124
EPR insulated, non-armoured shipwiring cable, 10mm2 630mm2 ........................................125
EPR insulated, braided armoured shipwiring cable, 1.5mm2 4mm2 ......................................126
EPR insulated, braided armoured shipwiring cable, 6mm2 300mm2 ....................................127
EPR insulated, single core braided shipwiring cable, 6mm2 630mm2 ..................................128

SECTION 12 Installation Accessories ......................................................................129

13

FIXED WIRING AND MAINS CABLES PVC

FIXED WIRING AND


MAINS CABLES
PVC

FIXED WIRING AND MAINS CABLES PVC

14

6491X (HO7V-R) PVC


Stranded plain annealed compacted circular copper conductor, PVC outer sheath.
Ref 6491X. Harmonised code HO7V-R. 450/750 volts grade to BS6004. Flame
propagation to BS EN 50265.
CCC
CODE
6491X1/5
6491X2/5
6491X4
6491X6
6491X10
6491X16
6491X25
6491X35
6491X50
6491X70
6491X95
6491X120
6491X150
6491X185
6491X240
6491X300
6491X400
6491X500
6491X630

PVC INSULATED WIRING


CABLE 6491X
(1.5MM2 TO 630MM2)
AND BARE COPPER STRAND
(6MM2 TO 400MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

WEIGHT
KG/KM

7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.50

21
35
50
71
120
180
280
380
510
720
990
1200
1500
1900
2500
3000
3950
4950
6250

Temperature limits:
-15 to +70C.
Bending radius:

OVERALL
DIAMETER
(MM)
3.00
3.65
4.20
4.75
6.15
7.10
8.90
9.95
11.70
13.35
15.60
17.20
19.10
21.30
24.30
27.05
30.35
32.80
36.50

BRASS A2

NYLON A2

20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20
20
25
25
25
32
32
40
40
50S
50S

16
16
16
16
16
16
20
20
20
25
25
25
32
32
32
40
40
50
50

4mm2-630mm2 - Brown, Black, Grey,


Blue, Green/Yellow.

up to 10mm2 - 3 x overall diameter.


above 25mm2 - 6 x overall diameter.

Should not be installed at


temperatures below 0C or
above +60C.

Standard colours available:


1.5mm2 & 2.5mm2 - Brown, Black,
Grey, Blue, Green/Yellow, White,
Orange, Turquoise, Violet, Pink.

BARE COPPER STRAND


Stranded plain annealed compacted circular copper conductor, non insulated
and non sheathed. 450 volts grade, soft drawn to BS6360/81.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

CB006
CB010
CB016
CB025
CB035
CB050
CB070
CB095
CB120
CB150
CB185
CB240
CB300
CB400

6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0

7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85

58
96
154
240
336
480
672
912
1152
1440
1776
2304
2800
3750

OVERALL
DIAMETER
(MM)
3.0
4.2
5.1
5.9
7.8
8.8
9.8
12.5
12.8
14.4
16.1
19.8
20.6
26.4

Temperature limits:
- 15 to + 70C
*Bending radius:
Up to 10mm - 3 x overall diameter.
Above 25mm - 6 x overall diameter.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

15

Plain annealed stranded circular copper conductor, single core, PVC insulated,
PVC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004. Brown/Grey or
Blue/Grey. Flame propagation to BS EN 50265.
CCC
CODE

CONDUCTOR STRANDING
SIZE (MM2)
(MM)

6181Y1
6181Y1/5
6181Y2/5
6181Y4
6181Y6
6181Y10
6181Y16
6181Y25
6181Y35
6181Y50
6181Y70
6181Y95
6181Y120

PVC INSULATED
PVC SHEATHED SURFACE
WIRING CABLE
TYPE 6181Y
(1MM2 TO 120MM2)
PVC INSULATED
PVC SHEATHED
WIRING CABLE
TYPE 624*Y
(1MM2 TO 16MM2)

1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0

NO. OF
CORES

1/1.13
1/1.38
1/1.78
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19.2.52
37/2.03

1
1
1
1
1
1
1
1
1
1
1
1
1

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
28
4.5
36
5.1
51
6.0
75
6.8
98
7.4
150
8.8
220
10.5
340
12.5
440
13.5
540
14.38
750
15.3
1010
17.7
1250
19.3

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
25
32

SINGLE
CLEAT
0.5
0.5
0.6
0.6
0.7
0.7
0.8

Temperature limits:
-15 to +70C.
Bending radius:
up to 10mm2 - 3 x overall diameter.
over 10mm2 - 4 x overall diameter.
Should not be installed at
temperatures below 0C or
above +60C.

SURFACE WIRING CABLES PVC 624*Y


Plain annealed copper conductor, PVC insulated one, two or three cores laid
flat with an uninsulated circuit protective conductor and PVC sheathed. Grey.
Ref 6241/2/3Y 300/500 V to BS6004. Flame propagation to BS EN 50265.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

NO. OF
CORES

6241Y1BR
6241Y1/5BR
6242Y1
6242Y1/5
6242Y1/5BRBR
6242Y2/5
6242Y4
6242Y6
6242Y10
6242Y16
6243Y1
6243Y1/5
6243Y2/5

1.0
1.5
1.0
1.5
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5

1/1.13
1/1.37
1/1.13
1/1.38
1/1.38
1/1.77
7/0.85
7/1.04
7/1.35
7.1.70
1/1.13
1/1.37
1/1.77

1
1
2
2
2
2
2
2
2
2
3
3
3

WEIGHT
KG/KM
(MM)
49
51
69
85
85
120
175
240
390
560
92
115
170

OVERALL
DIAMETER
(MM)
4.15 X 5.40
4.65 X 5.80
4.10 X 8.65
4.55 X 8.80
4.55 X 8.80
5.40 X 10.50
6.10 X 12.00
6.90 X 13.80
8.40 X 18.50
9.70 X 20.60
4.60 X 10.20
4.75 X 11.45
5.45 X 13.40

Temperature limits:
-15 to +70C.
*Bending radius:
Fixed 3 x overall diameter.
Should not be installed at
temperatures below 0C or
above +60C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

SURFACE WIRING CABLES PVC 6181Y

FIXED WIRING AND MAINS CABLES PVC

16

MAINS AND CONTROL CABLES PVC


Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade
to BS5467. Flame propagation to BS EN 60332.
CCC
CODE
XLPE2X1/5
XLPE3X1/5
XLPE4X1/5
XLPE5X1/5
XLPE7X1/5
XLPE8X1/5
XLPE10X1/5
XLPE12X1/5
XLPE19X1/5
XLPE27X1/5
XLPE37X1/5
XLPE48X1/5
XLPE2X2/5
XLPE3X2/5*
XLPE4X2/5
XLPE5X2/5
XLPE7X2/5
XLPE10X2/5
XLPE12X2/5
XLPE19X2/5
XLPE27X2/5
XLPE37X2/5
XLPE48X2/5
XLPE2X4
XLPE3X4*
XLPE4X4
XLPE5X4
XLPE7X4
XLPE12X4
XLPE19X4
XLPE27X4
XLPE2X6
XLPE3X6*
XLPE4X6
XLPE5X6
XLPE7X6
XLPE2X10
XLPE3X10*
XLPE4X10
XLPE5X10
XLPE7X10
XLPE2X16
XLPE3X16*
XLPE4X16
XLPE5X16
XLPE7X16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
16.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
7/1.70

Temperature limits:
-15 to +90C.
*Bending radius:
6 x overall diameter.

XLPE INSULATED
MAINS AND
CONTROL CABLE
(1.5MM2 TO 16MM2)

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core and above - up to 6mm2 White with Black numbers.

NO. OF
CORES
2
3
4
5
7
8
10
12
19
27
37
48
2
3
4
5
7
10
12
19
27
37
48
2
3
4
5
7
12
19
27
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
234
11.06
271
11.54
306
12.26
356
13.23
391
14.1
501
16.7
650
18
657
18.3
863
20.78
1310
25.1
1590
27.5
1900
30
312
12.4
343
12.99
392
13.86
463
14.92
509
15.96
850
20
861
21.11
1324
25.16
1760
30
2185
33
2800
36
373
13.38
421
14.05
496
15.04
573
16.35
741
18.21
1255
24.24
1690
27.61
2250
32
450
14.38
515
15.14
696
17.03
808
18.39
1100
21.9
590
16.18
781
17.76
927
19.09
1095
20.91
1500
25
893
19.06
1059
20.35
1269
21.95
1679
25.19
2150
28.1

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20
20
20
25
25
32
32
20S
20S
20S
20S
20
25
25
25
32
40
40
20S
20S
20
20
20
25
32
32
20S
20
20
20
25
20
20
25
25
25
25
25
25
25
32

SINGLE
CLEAT
0.5
0.5
0.5
0.6
0.6
0.7
0.8
0.8
0.9
1.0
1.1
1.2
0.5
0.6
0.6
0.6
0.8
0.8
0.9
1.0
1.2
1.4
1.6
0.6
0.6
0.6
0.7
0.8
1.0
1.1
1.4
0.6
0.7
0.7
0.8
0.9
0.7
0.8
0.8
0.9
1.0
0.8
0.9
0.9
1.1
1.2

5 core - 10mm2 and 16mm2 - Brown,


Black, Grey, Blue, Green/Yellow
1.5 & 2.5 - 2,3,4 core also available in
white numbered cores to ESI 09-6
Should not be installed at
temperatures below 0C or
above +60C.
* Additionally these cables are
stocked with Brown, Blue and
Green/Yellow core identification.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

17

Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,


galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to
BS5467. Flame propagation to BS EN 60332.
CCC
CODE
6942X25
6943X25
6944X25
6945X25
6942X35
6943X35
6944X35
6945X35
6942X50
6943X50
6944X50
6945X50
6942X70
6943X70
6944X70
6945X70
6942X95
6943X95
6944X95
6945X95
6942X120
6943X120
6944X120
6942X150
6943X150
6944X150
6942X185
6943X185
6944X185
6942X240
6943X240
6944X240
6942X300
6943X300
6944X300
6942X400
6943X400
6944X400

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400
400

7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85
61/2.85

NO. OF
CORES
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1050
20
1500
23
1800
25
2200
29
1400
22
1800
26
2200
28
2800
33
1750
25
2250
28
2850
31
3850
38
2200
28
3000
32
4100
37
5100
43
3000
32
4150
37
5200
40
7700
52
3600
35
4950
40
6700
46
4250
37
6300
45
7900
49
5500
43
7650
49
9650
55
6900
48
9650
56
12400
62
8200
50
11550
59
14800
66
10100
56
14350
65
19300
75

GLAND
SIZE
(MM)
25
25
32
32
25
32
32
40
32
32
32
40
32
32
40
50S
40
40
50S
50
40
50S
50
40
50
50
50
50
63S
50
63S
63
50
50
75S
63S
75S
75

SINGLE
CLEAT
0.8
1.0
1.0
1.2
0.9
1.1
1.2
1.4
1.0
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.4
1.6
1.8
TC9
1.4
1.8
2.0
1.6
1.8
2.0
1.8
2.0
TC9
2.0
TC9
TC10
2.0
TC10
TC11
TC9
TC11
TC12

Temperature limits:
-15 to +90C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
MAINS CABLE
(25MM2 TO 400MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

MAINS CABLES PVC

FIXED WIRING AND MAINS CABLES MDPE SHEATHED MDPE SHEATHED

18

FIXED WIRING AND MAINS CABLES


MDPE SHEATHED
Stranded plain annealed copper conductor, XLPE insulated, PVC bedding,
galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts
grade generally to BS5467.
CCC
CODE
6942PE4
6943PE4
6944PE4
6942PE6
6943PE6
6944PE6
6942PE10
6943PE10
6944PE10
6942PE16
6943PE16
6944PE16
6945PE16

CONDUCTOR
SIZE (MM) STRANDING
4.0
7/0.86
4.0
7/0.86
4.0
7/0.86
6.0
7/1.06
6.0
7/1.06
6.0
7/1.06
10.0
7/1.36
10.0
7/1.36
10.0
7/1.36
16.0
7/1.74
16.0
7/1.74
16.0
7/1.74
16.0
7/1.74

Temperature limits:
- 15 to + 90C
*Bending radius:

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
5

WEIGHT OVERALL GLAND


(KG/KM) DIAMETER SIZE (MM)
344
13.4
20S
389
14.1
20S
462
15.0
20S
418
14.4
20S
480
15.1
20S
655
17.0
20
552
16.2
20
739
17.8
20
881
19.1
20
847
19.1
20
1006
20.4
20
1211
22.0
25
1606
25.2
25

SINGLE
CLEAT
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0

Should not be installed at


temperatures below 0C or
above 40C.

8 x Overall Diameter
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
also available in Brown, Blue, Green/Yellow.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.

FIXED WIRING AND


MAINS CABLES MDPE
(4MM2 TO 16MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

19

Stranded plain annealed copper conductor, XLPE insulated, PVC bedding,


galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v volts
grade generally to BS5467.
CCC
CONDUCTOR
CODE
SIZE (MM) STRANDING
6942PE25
25
7/2.21
6943PE25
25
7/2.21
6944PE25
25
7/2.21
6945PE25
25
7/2.21
6942PE35
35
7/2.66
6943PE35
35
7/2.66
6944PE35
35
7/2.66
6945PE35
35
7/2.66
6942PE50
50
19/1.88
6943PE50
50
19/1.88
6944PE50
50
19/1.88
6945PE50
50
19/1.88
6942PE70
70
19/2.21
6943PE70
70
19/2.21
6944PE70
70
19/2.21
6945PE70
70
19/2.21
6942PE95
95
37/1.88
6943PE95
95
37/1.88
6944PE95
95
37/1.88
6945PE95
95
37/1.88
6942PE120
120
30/2.32
6943PE120
120
30/2.32
6944PE120
120
30/2.32
6942PE150
150
37/2.32
6943PE150
150
37/2.32
6944PE150
150
37/2.32
6942PE185
185
37/2.55
6943PE185
185
37/2.55
6944PE185
185
37/2.55
6942PE240
240
60/2.32
6943PE240
240
60/2.32
6944PE240
240
60/2.32
6942PE300
300
61/2.66
6943PE300
300
61/2.66
6944PE300
300
61/2.66
6943PE400
400
60/2.96
6944PE400
400
60/2.96

Temperature limits:
- 15 to + 90C
*Bending radius:

NO. OF
CORES
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4

WEIGHT OVERALL GLAND


(KG/KM) DIAMETER SIZE (MM)
1162
22.2
25
1562
24.9
25
1895
26.8
32
2280
29.5
32
1606
25.5
25
1964
27.2
32
2393
29.5
32
2898
32.4
32
1654
25.9
25
2199
28.6
32
2763
32.1
32
3876
36.4
40
2174
29.2
32
2937
32.3
32
3967
37.4
40
5166
41.7
50S
2987
33.2
32
4036
37.0
40
5128
41.6
50S
6795
48.6
50
3561
36.4
40
4829
40.5
50S
6578
47.0
50
4258
39.4
40
6268
45.8
50S
7967
51.5
50
5423
44.3
50S
7390
49.9
50
9403
56.2
63S
6736
49.2
50
9238
55.1
63S
11898
62.4
63
7896
51.3
50
11136
60.3
63
14328
68.4
75S
13778
67.9
75S
18669
78.8
90

SINGLE
CLEAT
0.9
1.0
1.1
1.2
1.1
1.1
1.2
1.4
1.1
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.4
1.6
1.8
2.0
1.6
1.6
2.0
1.6
2.0
TC9
1.8
2.0
TC9
2.0
TC9
TC10
TC9
TC10
TC11
TC11
TC14

Should not be installed at


temperatures below 0C or
above 40C.

8 x Overall Diameter
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
also available in Brown, Blue, Green/Yellow.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.

FIXED WIRING AND


MAINS CABLES MDPE
(25MM2 TO 400MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES MDPE SHEATHED

FIXED WIRING AND MAINS CABLES


MDPE SHEATHED

FIXED WIRING AND MAINS CABLES PVC

20

MAINS CABLES WITH ALUMINIUM CONDUCTORS PVC


Solid plain aluminium sectoral conductors, XLPE insulated, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade
to BS5467. Flame propagation to BS EN 60332.
CCC
CODE

CONDUCTOR
SIZE (MM2)

NO. OF
CORES

WEIGHT
KG/KM

SAC4X25
SAC4X35
SAC4X50
SAC4X70
SAC4X95
SAC4X120
SAC4X150
SAC4X185
SAC4X240
SAC4X300

25
35
50
70
95
120
150
185
240
300

4
4
4
4
4
4
4
4
4
4

1235
1515
1686
2401
2905
3705
4550
5076
6104
7212

OVERALL
DIAMETER
(MM)
25.4
28.9
29.5
34.7
38.3
42.2
46.0
51.1
56.4
61.4

GLAND
SIZE
(MM)
25
32
32
40
40
50S
50
50
63S
63

SINGLE
CLEAT
1.0
1.2
1.2
1.4
1.6
1.8
2.0
TC9
TC9
TC10

Temperature limits:
-15 to +90C.
*Bending radius:
8 x overall diameter.
Core identification:
Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
MAINS CABLE
WITH ALUMINIUM
CONDUCTORS
(25MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

21

Plain annealed stranded compacted circular copper conductor, single core,


XLPE insulated, PVC outer sheath Black. 600/1000 volts grade to BS7889/97.
Flame propagation to BS EN 60332.
CCC
CODE

CONDUCTOR STRANDING WEIGHT OVERALL


SIZE (MM2)
(MM)
KG/KM DIAMETER
(MM)
6181X50
50
19/1.78
520
13.5
6181X70
70
19/2.14
720
15.5
6181X95
95
19/2.52
985
17.5
6181X120
120
37/2.03
1215
19
6181X150
150
37/2.25
1515
21.5
6181X185
185
37/2.52
1865
23.5
6181X240
240
61/2.25
2415
26.5
6181X300
300
61/2.52
3005
29
6181X400
400
61/2.85
3810
32.5
6181X500
500
61/3.20
4890
37
6181X630
630
127/2.52
6355
42
6181X800
800
127/2.85
8075
46
6181X1000
1000
127/3.20
9860
53

BRASS
A2
25
25
25
32
32
32
40
40
50S
50S
50
63S
63

NYLON SINGLE TREFOIL


A2
CLEAT CLEAT
25
25
25
32
32
32
40
40
50
50
63
-

0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.6
1.8
2.0
TC9

376AC04
376AC06
376AC09
376AC12
376AC15
376AC19

Temperature limits:
-15 to +90C.
*Bending radius:
8 x overall diameter.
Core identification:
Brown inner / Black outer.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
SINGLE CORE
NON-ARMOURED
MAINS CABLE
(50MM2 TO 1000MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

SINGLE CORE NON-ARMOURED MAINS CABLES PVC

FIXED WIRING AND MAINS CABLES PVC

22

FIXED WIRING AND MAINS CABLES


Stranded plain annealed compacted circular copper conductors, XLPE
insulated, PVC bedding, aluminium wire armoured, PVC outer sheath. Black.
600/100 volts grade to BS5467. Flame propagation to BS EN 60332.
CCC
CODE

6941AX50
6941AX70
6941AX95
6941AX120
6941AX150
6941AX185
6941AX240
6941AX300
6941AX400
6941AX500
6941AX630
6941AX800
6941AX1000

CONDUCTOR
NO. OF WEIGHT OVERALL GLAND GLAND SINGLE
SIZE (MM) STRANDING CORES (KG/KM) DIAMETER SIZECW
SIZE
CLEAT
ALI(MM) BRASS
A2 (MM)
50.0
19/1.78
1
638
17.70
20
25
0.7
70.0
19/2.14
1
891
19.60
25
32
0.8
95.0
19/2.52
1
1166
21.50
25
32
0.9
120.0
37/2.03
1
1412
23.10
25
32
1.0
150.0
37/2.25
1
1800
26.00
32
40
1.1
185.0
37/2.52
1
2200
28.00
32
40
1.2
240.0
61/2.25
1
2800
32.00
40
50S
1.4
300.0
61/2.52
1
3400
33.00
40
50S
1.4
400.0
61/2.85
1
4450
38.00
40
50
1.6
500.0
61/3.2
1
5550
43.00
50S
63S
1.8
630.0
127/2.52
1
7100
47.00
50
63S
2.0
800.0
127/2.85
1
9200
55.00
63S
75S
TC9
1000.0
127/3.2
1
11270
58.80
63S
75S
TC10

TREFOIL
CLEAT

376AC04
376AC06
376AC06
376AC10
376AC13
376AC15
376AC20
376AC22

Temperature limits:
- 15 to + 90C
*Bending radius:
6 x Overall Diameter
Core identification:
Brown inner - Black outer
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
SINGLE CORE ARMOURED
MAINS CABLE
(50MM2 TO 1000MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

23

Plain annealed stranded copper conductors, XLPE insulated, PVC extruded


bedding, galvanised steel wire armour incorporating tinned copper wires to
provide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000
volts grade generally to BS5467 and BC295. Flame propagation to BS EN 60332.
CCC
CODE
NCB3X10/1
NCB4X10/1
NCB3X16/1
NCB4X16/1
NCB3X25
NCB4X25
NCB3X35
NCB4X35
NCB3X50
NCB4X50
NCB3X70
NCB4X70
NCB3X95
NCB4X95
NCB3X120
NCB4X120
NCB3X150
NCB4X150
NCB3X185
NCB4X185
NCB3X240
NCB4X240
NCB3X300
NCB4X300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
10
10
16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300

7/1.04
7/1.04
7/1.70
7/1.70
7/2.14
7/2.14
7/2.52
7/2.52
19/1.78
19/1.78
19/2.14
19/2.14
19/2.52
19/2.52
37/2.03
37/2.03
37/2.25
37/2.25
37/2.52
37/2.52
61/2.25
61/2.25
61/2.52
61/2.52

NO. OF
CORES
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
896
18.9
1038
20.3
1205
23.1
1675
26.3
1550
26.9
1880
29.1
1940
29.6
2350
32.1
2360
28.4
2950
31.3
3120
32.0
4230
36.8
4310
36.7
5390
40.6
5160
40.0
6980
45.8
6610
45.1
8300
49.9
7920
49.3
10070
54.9
9930
54.5
12680
61.0
11970
59.5
15380
66.5

GLAND
SIZE
(MM)
20
20
25
25
25
32
32
32
32
32
32
40
40
50S
50S
50S
50S
50
50
63S
63S
63
63
75S

SINGLE
CLEAT
0.8
0.8
1.0
1.1
1.1
1.2
1.2
1.4
1.2
1.4
1.4
1.6
1.6
1.6
1.6
2.0
1.8
2.0
2.0
TC9
TC9
TC10
TC10
TC11

Temperature limits:
-15 to +70C.
*Bending radius:
up to 16mm2 - 6 x overall diameter.
over 16mm2 - 8 x overall diameter.
Core identification:
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED MAINS


CABLE WITH 60%
CONDUCTIVITY
IN ARMOUR.
(MINES & QUARRIES
& BRITISH COAL)
(10MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

MAINS CABLES FOR MINES & QUARRIES PVC

FIXED WIRING AND MAINS CABLES PVC

24

EEMUA133 CONTROL CABLES PVC


Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead
sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores
white with black numbers. 600/1000 volts grade to BS5467 and EEMUA 133. Flame
propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2
(IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C).
CCC
CODE
EEMUA2X1/5ESI
EEMUA3X1/5ESI
EEMUA4X1/5ESI
EEMUA5X1/5
EEMUA7X1/5
EEMUA12X1/5
EEMUA19X1/5
EEMUA27X1/5
EEMUA37X1/5
EEMUA2X2/5ESI
EEMUA3X2/5ESI
EEMUA4X2/5ESI
EEMUA5X2/5
EEMUA7X2/5
EEMUA12X2/5
EEMUA19X2/5
EEMUA27X2/5
EEMUA37X2/5
EEMUA5X4
EEMUA7X4

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85

NO. OF
CORES
2
3
4
5
7
12
19
27
37
2
3
4
5
7
12
19
27
37
5
7

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
690
15
750
15.5
810
16
895
16.8
1072
17.7
1387
22.3
1686
24.8
2418
30
2850
32.7
800
16
870
16.5
950
17.5
1038
18.4
1180
20
1750
24.5
2450
29
3100
33
3720
36
1014
20.6
1110
21.5

GLAND
SIZE
(MM)
20
20
20
20
20
25
25
32
32
20
20
20
20
20
25
32
32
40
20
25

SINGLE
CLEAT
0.6
0.7
0.7
0.7
0.7
0.9
1.0
1.2
1.4
0.7
0.7
0.7
0.8
0.8
1.0
1.2
1.4
1.6
0.9
0.9

Temperature limits:
-15 to +90C.
*Bending radius:
12 x overall diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED LEAD


SHEATHED CONTROL
CABLE FOR
PETRO-CHEMICAL
INDUSTRIES
(1.5MM2 TO 4MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

25

Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead
sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black.
600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame
propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2
(IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C).
CCC
CODE
EEMUA2X1/5
EEMUA3X1/5
EEMUA4X1/5
EEMUA2X2/5
EEMUA3X2/5
EEMUA4X2/5
EEMUA2X4
EEMUA3X4
EEMUA4X4
EEMUA2X6
EEMUA3X6
EEMUA4X6
EEMUA2X10
EEMUA3X10
EEMUA4X10
EEMUA2X16
EEMUA3X16
EEMUA4X16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0

7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
690
15
750
15.5
810
16
800
16
870
16.5
950
17.5
920
17.5
1000
17.5
1110
19
1020
18
1150
19
1400
20.5
1250
20
1530
22
1720
23
1630
23
1880
24
2150
26

GLAND
SIZE
(MM)
20
20
20
20
20
20
20
20
25
20
25
25
25
25
25
25
25
32

SINGLE
CLEAT
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.8
0.9
1.0
1.0
1.0
1.1

Temperature limits:
-15 to +90C.
*Bending radius:
12 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED LEAD


SHEATHED MAINS CABLE
FOR PETRO-CHEMICAL
INDUSTRIES
(1.5MM2 TO 16MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

EEMUA133 MAINS CABLES PVC

FIXED WIRING AND MAINS CABLES PVC

26

EEMUA133 MAINS CABLES PVC


Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead
sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black.
600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame
propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2
(IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C).
CCC
CODE
EEMUA2X25
EEMUA3X25
EEMUA4X25
EEMUA2X35
EEMUA3X35
EEMUA4X35
EEMUA2X50
EEMUA3X50
EEMUA4X50
EEMUA2X70
EEMUA3X70
EEMUA4X70
EEMUA2X95
EEMUA3X95
EEMUA4X95
EEMUA2X120
EEMUA3X120
EEMUA4X120
EEMUA2X150
EEMUA3X150
EEMUA4X150
EEMUA2X185
EEMUA3X185
EEMUA4X185
EEMUA2X240
EEMUA3X240
EEMUA4X240
EEMUA2X300
EEMUA3X300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300

7/2.14
7/2.14
7/2.14
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
2094
27.1
2740
30
3160
32
2868
31.9
3205
32
3840
34.5
2783
28.1
3655
33.5
4530
37
3566
31.1
4675
37.5
6175
43
4678
35.1
6180
42.5
7695
47
5641
38.5
7390
46
9730
53
6660
41.8
9300
52
11530
58.5
8457
47.1
10980
56.5
14160
65
10286
52.3
13815
63
17700
65.8
16519
64.1
21173
71.5

GLAND
SIZE
(MM)
32
32
32
32
32
40
32
40
40
32
40
50S
40
50S
50
50S
50
63S
50S
50
63S
50
63S
63
50
63
75S
63
75S

SINGLE
CLEAT
1.1
1.2
1.4
1.4
1.4
1.4
1.2
1.6
1.6
1.4
1.6
1.8
1.4
1.8
2.0
1.6
2.0
TC9
1.8
TC9
TC10
2.0
TC9
TC11
TC9
TC10
TC11
TC11
TC12

Temperature limits:
-15 to +90C.
*Bending radius:
12 x overall diameter.
Core identification:
2 core - Brown, Blue
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
LEAD SHEATHED MAINS
CABLE FOR
PETRO-CHEMICAL
INDUSTRIES
(25MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

27

Plain annealed compacted circular copper conductor, XLPE insulated, PVC outer
sheath, 600/1000 volts grade generally to BS5467 & IEC 60502. Colours
Black/Black or Red/Red.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

6181X6
6181X10
6181X16
6181X25
6181X35
6181X50
6181X70
6181X95
6181X120
6181X150
6181X185

6
10
16
25
35
50
70
95
120
150
185

7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52

105
150
210
305
395
515
725
1230
1355
1695
2110

*Bending radius:

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
20
20
25
25
32
32
32

Should not be installed at


temperatures below 0C or
above +60C.

4 x overall diameter.

XLPE INSULATED NONARMOURED AND


ARMOURED SINGLE CORE
CABLE FOR CATHODIC
PROTECTION
(6MM2 TO 185MM2)

OVERALL
DIAMETER
(MM)
7.2
8.1
9.0
10.6
11.6
13.0
14.9
17.5
19.2
21.3
23.4

SINGLE CORE ARMOURED CATHODIC


PROTECTION CABLES PVC
Plain annealed compacted circular copper conductor, XLPE insulated, PVC
bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000
volts grade generally to IEC 60502 & BS5467.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

6941X6
6941X10
6941X16
6941X25
6941X35
6941X50
6941X70
6941X95
6941X120
6941X150
6941X185

6
10
16
25
35
50
70
95
120
150
185

7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52

285
355
435
585
685
835
1080
1375
1685
2120
2505

*Bending radius:
4 x overall diameter.

OVERALL
DIAMETER
(MM)
11.5
12.5
13.5
15.0
16.0
17.5
19.5
21.6
23.4
26.4
28.9

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
20
20
20
25
25
25
32

Should not be installed at


temperatures below 0C or
above +60C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

SINGLE CORE NON-ARMOURED CATHODIC


PROTECTION CABLES PVC

FIXED WIRING AND MAINS CABLES PVC

28

SPLIT CONCENTRIC CABLES PVC


Plain annealed stranded copper phase conductor, XLPE insulated surrounded
by a concentric layer of plain annealed solid copper neutral conductors. XLPE
insulated and plain annealed solid strand bare copper earth conductors, PVC
outer sheath. Black. 600/1000 volts grade to BS 7870.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

4 SPLITCON
6 SPLITCON
10 SPLITCON
16 SPLITCON
25 SPLITCON
35 SPLITCON

4
6
10
16
25
35

7/0.85
7/1.04
7/1.35
7/1.70
**7/2.14
7/2.52

206
281
394
583
843
1300

OVERALL
DIAMETER
(MM)
9.6
11.4
12.7
14.6
18.7
23.0

GLAND
SIZE
(MM)
20S
20
20
25
32
40

**Stranding of neutral is the same as


phase conductor except 25 sq mm
which has 11 x 1.70mm.

Should not be installed at


temperatures below 0C or
above +60C.

Conductor identification:
Brown Live/Blue Neutral.

Also available in Violet outer sheath


in 6mm, 10mm, 16mm & 25mm.

STRAIGHT CONCENTRIC CABLES PVC


Plain annealed stranded copper phase conductor, PVC insulated surrounded by
a concentric layer of plain annealed solid copper neutral/earth conductors in
concentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 7870 &
ESI 09-7. Combined neutral and earth (CNE).
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

4 STRCON
6 STRCON
16 STRCON
25 STRCON
35 STRCON

4
6
16
25
35

7/0.85
7/1.04
7/1.70
7/2.14
7/2.25

180
230
440
600
850

OVERALL
DIAMETER
(MM)
9.0
10.0
12.0
15.0
16.0

GLAND
SIZE
(MM)
20S
20S
20
25
25

Temperature limits:
-15 to +70C.
*Bending radius:
10 x overall diameter.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED SINGLE


PHASE SPLIT AND
STRAIGHT CONCENTRIC
SERVICE CABLE
(4MM2 TO 35MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

29

FIXED WIRING AND MAINS CABLES PVC

FIXED WIRING AND


MAINS CABLES
3300V PVC

FIXED WIRING AND MAINS CABLES PVC

30

SINGLE CORE ARMOURED MAINS CABLES 1900/3300V


Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,
Aluminium wire armour, PVC outer sheath. Black. 1900/3300 volts grade to
BS5467. Flame propagation to BS EN 60332.
CCC
CODE
6941AX120/3
6941AX150/3
6941AX185/3
6941AX240/3
6941AX300/3
6941AX400/3
6941AX500/3
6941AX630/3

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE
CLEAT CLEAT
(MM)
(MM)
120
37/2.03
1
1490
23.2
25
1.2
150
37/2.25
1
1870
26.3
32
1.2
185
37/2.52
1
2290
28.7
32
1.4 376AC04
240
61/2.25
1
2880
31.4
40
1.4 376AC05
300
61/2.52
1
3520
34.1
40
1.8 376AC07
400
61/2.85
1
4520
38.9
50S
1.8 376AC10
500
61/3.20
1
5680
42.8
50S
1.8 376AC12
630
127/2.52
1
7120
47.3
50
2.0 376AC15

Temperature limits:
-25 to +90C.
*Bending radius:
6 x overall diameter.
Core identification:
Brown inner/Black outer.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
SINGLE CORE ARMOURED
MAINS CABLE
3300V
(120MM2 TO 630MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

31

Stranded plain annealed copper conductors, XLPE insulated, PVC bedding,


galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade
to BS5467. Flame propagation to BS EN 60332.
CCC
CODE
XLPE3X16/3
XLPE3X25/3
XLPE3X35/3
XLPE3X50/3
XLPE3X70/3
XLPE3X95/3
XLPE3X120/3
XLPE3X150/3
XLPE3X185/3
XLPE3X240/3
XLPE3X300/3
XLPE3X400/3

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
16
25
35
50
70
95
120
150
185
240
300
400

7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85

NO. OF
CORES
3
3
3
3
3
3
3
3
3
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1600
29.5
2060
32.3
2330
35.0
3040
34.9
3800
38.0
4730
41.4
6070
45.6
7010
48.3
8270
51.6
10310
56.5
12300
60.7
14780
65.8

GLAND
SIZE
(MM)
32
32
40
40
40
50S
50S
50
50
63S
63
75S

SINGLE
CLEAT
1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
TC9
TC9
TC10
TC11

Temperature limits:
-15 to +90C.
*Bending radius:
8 x overall diameter.
Core identification:
Brown, Black, Grey.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
MAINS CABLE
3300 VOLT
(16MM2 TO 400MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

3 CORE MAINS CABLES 1900/3300V PVC

FIXED WIRING AND MAINS CABLES PVC

32

MAINS CABLES FOR MINES & QUARRIES 1900/3300V


Plain annealed stranded copper conductors, XLPE insulated, PVC extruded
bedding, galvanised steel wire armour incorporating tinned copper wires to
provide 60% conductivity of any one phase, PVC outer sheath. Black.
1900/3300 volts grade generally to BS5467 and BC295. Flame propagation to
BS EN 60332.
CCC
CODE
NCB3X16/3
NCB3X25/3
NCB3X35/3
NCB3X50/3
NCB3X70/3
NCB3X95/3
NCB3X120/3
NCB3X150/3
NCB3X185/3
NCB3X240/3
NCB3X300/3

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
16
25
35
50
70
95
120
150
185
240
300

7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52

NO. OF
CORES
3
3
3
3
3
3
3
3
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1600
29.5
2060
32.3
2330
35.0
3040
34.9
3800
38.0
4730
41.4
6070
45.6
7110
48.3
8270
51.6
10310
56.5
12300
60.7

GLAND
SIZE
(MM)
32
32
40
40
40
50S
50S
50
50
63S
63

SINGLE
CLEAT
1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
TC9
TC9
TC10

Temperature limits:
-15 to +70C.
*Bending radius:
up to 16mm2 - 6 x overall diameter.
over 16mm2 - 8 x overall diameter.
Core identification:
3 core - Brown, Black, Grey
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED MAINS


CABLE 3300V
WITH 60%
CONDUCTIVITY
IN ARMOUR.
(MINES & QUARRIES &
BRITISH COAL)
(16MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

33

Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead
sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black.
1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame
propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-22 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C).
CCC
CODE
EEMUA3X25/3
EEMUA3X35/3
EEMUA3X50/3
EEMUA3X70/3
EEMUA3X95/3
EEMUA3X120/3
EEMUA3X150/3
EEMUA3X185/3
EEMUA3X240/3
EEMUA3X300/3

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
35
50
70
95
120
150
185
240
300

7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52

NO. OF
CORES
3
3
3
3
3
3
3
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
3400
32.5
3560
38.4
4520
38.1
5550
41.4
6770
45.0
8390
49.4
9630
52.3
11270
55.8
13720
60.9
16380
65.3

GLAND
SIZE
(MM)
32
40
40
50S
50S
50
50
63S
63
75S

SINGLE
CLEAT
1.4
1.6
1.6
1.8
2.0
2.0
TC9
TC9
TC10
TC11

Temperature limits:
-15 to +90C.
*Bending radius:
12 x overall diameter.
Core identification:
Brown, Black, Grey.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
LEAD SHEATHED MAINS
CABLE FOR
PETRO-CHEMICAL
INDUSTRIES
3300 VOLT
(25MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES PVC

EEMUA133 MAINS CABLES 1900/3300V PVC

35

FIXED WIRING AND MAINS CABLES LSZH

FIXED WIRING AND


MAINS CABLES
LSZH

FIXED WIRING AND MAINS CABLES LSZH

36

6491B (HO7Z-R) LSZH


Stranded plain annealed compacted circular copper conductor, low smoke and
zero halogen (LSZH) outer sheath. 450/750 volts grade to BS7211. Acid gas
emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC
61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and
zero halogen (LSZH).
CCC
CODE
6491B1/5
6491B2/5
6491B4
6491B6
6491B10
6491B16
6491B25
6491B35
6491B50
6491B70
6491B95
6491B120
6491B150
6491B185
6491B240
6491B300
6491B400
6491B500
6491B630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

WEIGHT
KG/KM

7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.50

22
33
49
69
116
175
273
367
510
715
990
1230
1510
1900
2490
3050
3842
4900
6334

OVERALL
DIAMETER
(MM)
3
3.65
4.2
4.75
6.15
7.1
8.9
9.95
11.7
13.35
15.6
17.2
19.1
21.3
24.36
27.05
30.35
32.8
36.5

BRASS A2

NYLON A2

20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20
20
25
25
25
32
32
40
40
50S
50S

16
16
16
16
16
16
20
20
20
25
25
25
32
32
32
40
40
50
50

Temperature limits:
-15 to +90C.
*Bending radius:
up to 10mm2 - 3 x overall diameter
above 25mm2 - 6 x overall diameter
Standard colours available:
1.5mm2 & 2.5mm2 - Brown, Black,
Grey, Blue, Green/Yellow, White,
Orange, Turquoise, Violet, Pink.
4mm2 - 630mm2 - Brown, Black, Grey,
Blue, Green/Yellow.
Should not be installed at
temperatures below 0C or
above +40C.

LOW SMOKE ZERO


HALOGEN INSULATED
WIRING CABLE 6491B
(1.5MM2 TO 630MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

37

Plain annealed stranded circular copper conductor, single core, XLPE insulated,
(LSZH) sheathed, Ref 6181B. 300/500 volts grade to BS7889. Brown/White or
Grey/White. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to
BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332),
low smoke and zero halogen (LSZH).
CCC
CODE

CONDUCTOR STRANDING
SIZE (MM2)
(MM)

6181B1
6181B1/5
6181B2/5
6181B4
6181B6
6181B10
6181B16
6181B25
6181B35

1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0

NO. OF
CORES

1/1.13
1/1.38
1/1.78
7/0.85
7/1.04
7/1.35
7/1.04
7/2.14
7/2.52

Temperature limits:
-25 to +90C.
*Bending radius:

XLPE INSULATED
LSZH SHEATHED SURFACE
WIRING CABLE TYPE
6181B
(1MM2 TO 35MM2)
XLPE INSULATED
LSZH SHEATHED
WIRING CABLE TYPE
624*B
2
(1MM TO 16MM2)

1
1
1
1
1
1
1
1
1

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
28
4.5
34
5.1
49
6.0
75
6.8
99
7.4
155
8.8
225
10.5
340
12.5
440
13.5

GLAND
REF
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25

CLEAT
SIZE
0.5
0.5
0.6

Should not be installed at


temperatures below 0C or
above +40C.

up to 10mm2 - 3 x overall diameter


over 10mm2 - 4 x overall diameter

SURFACE WIRING CABLES LSZH 624*B


Plain annealed compacted copper conductor, XLPE insulated, one, two or three
cores laid flat with an uninsulated circuit protective conductor and (LSZH)
sheathed. White. Ref 6241/2/3B 300/500V to BS7211 low smoke and zero
halogen (LSZH). Acid gas emission to BS EN 50267 (IEC60754), smoke emission
to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC
60332), low smoke and zero halogen (LSZH).
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

NO.OF
CORES

6241B1/5BR
6241B1/5BR
6242B1WH
6242B1/5WH
6242B1/5BRBR
6242B2/5WH
6242B4WH
6242B6WH
6242B10WH
6242B16WH
6243B1WH
6243B1/5WH
6243B2/5WH

1.5
1.5
1.0
1.5
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5

1/1.37
1/1.37
1/1.13
1/1.37
1/1.37
1/1.77
7/0.85
7/1.04
7/1.35
7/1.70
1/1.13
1/1.37
1/1.77

1
1
2
2
2
2
2
2
2
2
3
3
3

Temperature limits:
-25 to +90C.
*Bending radius:

WEIGHT
KG/KM
(MM)
51
51
69
85
85
120
175
240
390
560
92
115
170

OVERALL
DIAMETER
4.65 X 5.80
4.65 X 5.80
4.10 X 8.65
4.55 X 8.80
4.55 X 8.80
5.40 X 10.50
6.10 X 12.00
6.90 X 13.80
8.40 X 18.50
9.70 X 20.60
4.60 X 10.20
5.75 X 11.45
5.30 X 12.80

Should not be installed at


temperatures below 0C or
above +40C.

Fixed = 3 x diameter

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES LSZH

SURFACE WIRING CABLES LSZH 6181B

FIXED WIRING AND MAINS CABLES LSZH

38

MAINS AND CONTROL CABLES LSZH


Plain annealed stranded copper conductors, XLPE insulated, low smoke and
zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and
zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid
gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268
(IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265,
Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH).
CCC
CODE
LSF2X1/5
LSF3X1/5
LSF4X1/5
LSF5X1/5
LSF7X1/5
LSF12X1/5
LSF19X1/5
LSF27X1/5
LSF37X1/5
LSF48X1/5
LSF2X2/5
LSF3X2/5
LSF4X2/5
LSF5X2/5
LSF7X2/5
LSF12X2/5
LSF19X2/5
LSF27X2/5
LSF37X2/5
LSF48X2/5
LSF2X4
LSF3X4
LSF4X4
LSF5X4
LSF7X4
LSF12X4
LSF19X4
LSF27X4
LSF2X6
LSF3X6
LSF4X6
LSF5X6
LSF7X6
LSF2X10
LSF3X10
LSF4X10
LSF5X10
LSF7X10
LSF2X16
LSF3X16
LSF4X16
LSF5X16
LSF7X16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
16.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
7/1.70

Temperature limits:
-25 to +90C
*Bending radius:
6 x overall diameter.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN MAINS AND
CONTROL CABLE
(1.5MM2 TO 16MM2)

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core and above - Up to 6mm2 White with Black numbers.

NO. OF
CORES
2
3
4
5
7
12
19
27
37
48
2
3
4
5
7
12
19
27
37
48
2
3
4
5
7
12
19
27
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
260
11
295
11.2
350
12.5
362
12.9
398
13.7
680
18
885
20.6
1310
25.1
1590
27.5
1958
31
270
12.2
360
12.8
410
13.5
435
14.7
520
15.6
905
21
1360
25
1760
30
2185
33
3003
37.3
381
13.1
435
13.7
495
14.8
583
16.35
760
18.2
1266
24.24
1701
27.61
2347
32.3
405
14.1
490
14.8
670
17.3
823
18.39
1100
21.9
600
16.1
750
17.9
885
19.3
1106
20.91
1500
25
905
19
990
20
1195
22
1695
25.19
2150
28.1

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
20S
20
25
32
32
32
20S
20S
20S
20
20
25
32
32
40
40
20S
20S
20
20
20
25
32
40
20
20
20
20
25
20
20
25
25
25
25
25
25
25
32

SINGLE
CLEAT
0.5
0.5
0.5
0.6
0.6
0.8
0.9
1.0
1.1
1.4
0.5
0.6
0.6
0.6
0.7
0.9
1.0
1.2
1.4
1.6
0.6
0.6
0.6
0.7
0.8
1.0
1.2
1.4
0.6
0.6
0.7
0.8
0.9
0.7
0.8
0.8
0.9
1.0
0.8
0.8
0.9
1.0
1.2

5 - 10mm2 and 16mm2 - Brown,


Black, Grey, Blue, Green/Yellow.
1.5 & 2.5 - 2,3,4 core also available in
white numbered cores to ESI 09-6
Should not be installed at
temperatures below 0C or
above +40C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

39

Stranded plain annealed copper conductors, XLPE insulated, low smoke and
zero halogen (LSZH) extruded bedding, galvanised steel wire armour, low
smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade
to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission
to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 603323, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero
halogen (LSZH).
CCC
CODE
LSF2X25
LSF3X25
LSF4X25
LSF5X25
LSF2X35
LSF3X35
LSF4X35
LSF5X35
LSF2X50
LSF3X50
LSF4X50
LSF5X50
LSF2X70
LSF3X70
LSF4X70
LSF5X70
LSF2X95
LSF3X95
LSF4X95
LSF5X95
LSF2X120
LSF3X120
LSF4X120
LSF5X120
LSF2X150
LSF3X150
LSF4X150
LSF5X150
LSF2X185
LSF3X185
LSF4X185
LSF2X240
LSF3X240
LSF4X240
LSF2X300
LSF3X300
LSF4X300
LSF3X400
LSF4X400

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
120
150
150
150
150
185
185
185
240
240
240
300
300
300
400
400

7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85

NO. OF
CORES
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1050
20
1500
23
1800
25
2200
29
1400
22
1800
26
2200
28
2800
33
1750
25
2250
28
2850
31
3850
38
2200
28
3000
32
4100
37
5100
43
3000
32
4150
37
5200
40
7700
52
3600
35
4950
40
6700
46
9030
56.7
4250
37
6300
45
7900
49
10752
64.31
5500
43
7650
49
9650
55
6900
48
9650
56
12400
62
8200
50
11550
59
14800
66
14350
65
19300
75

GLAND
SIZE
(MM)
25
25
32
32
25
32
32
40
32
32
32
40
32
32
40
50S
32
40
50S
50
40
50S
50
63S
40
50S
50
63
50S
50
63S
50
63S
63
50
63
75S
75S
75

SINGLE
CLEAT
0.8
1.0
1.0
1.2
0.9
1.1
1.2
1.4
1.0
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.4
1.6
1.6
TC9
1.4
1.6
2.0
TC9
1.6
1.8
2.0
TC11
1.8
2.0
TC9
2.0
TC9
TC10
2.0
TC10
TC11
TC11
TC12

Temperature limits:
-25 to +90C.
*Bending radius:
8 x overall diameter.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN MAINS CABLE
(25MM2 TO 400MM2)

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below
0C or above +40C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES LSZH

MAINS CABLES LSZH

FIXED WIRING AND MAINS CABLES LSZH

40

SINGLE CORE NON-ARMOURED MAINS CABLES LSZH


Plain annealed stranded compacted circular copper conductor, single core,
XLPE insulated, low smoke and zero halogen (LSZH) outer sheath. Black.
600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC
60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation
to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low
smoke and zero halogen (LSZH).
CCC
CODE
6181B50
6181B70
6181B95
6181B120
6181B150
6181B185
6181B240
6181B300
6181B400
6181B500
6181B630
6181B800
6181B1000

CONDUCTOR STRANDING WEIGHT OVERALL BRASS


SIZE (MM2)
(MM)
KG/KM DIAMETER A2
50
70
95
120
150
185
240
300
400
500
630
800
1000

19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.52
61/3.20
127/2.52
127/2.85
127/3.20

525
730
990
1230
1525
1885
2440
3045
3855
4950
6345
8140
9860

13
15.5
18
19.5
21.5
24
27
29.5
33
37.5
42
47.5
53

25
25
25
32
32
32
40
40
50S
50S
50
63S
63

NYLON SINGLE
A2
CLEAT
(MM)
25
0.6
25
0.7
25
0.7
32
0.8
32
0.9
32
1.0
40
1.1
40
1.2
50
1.4
50
1.6
63
1.8
2.0
TC9

TREFOIL
CLEAT
376AC04
376AC06
376AC09
376AC12
376AC15
376AC19

Temperature limits:
-25 to +90C.
*Bending radius:
6 x overall diameter.
Core identification:
Brown inner/Black outer.
Should not be installed at
temperatures below 0C or
above +40C.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN SINGLE CORE
NON-ARMOURED
MAINS CABLE
(50MM2 TO 1000MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

41

Stranded plain annealed compacted circular copper conductors, XLPE


insulated, low smoke and zero halogen (LSZH) extruded bedding, aluminium
wire armour, low smoke and zero halogen (LSZH) outer sheath. Black.
600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267
(IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame
propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS
EN 50266,low smoke and zero halogen (LSZH).
CCC
CODE

6941AB50
6941AB70
6941AB95
6941AB120
6941AB150
6941AB185
6941AB240
6941AB300
6941AB400
6941AB500
6941AB630
6941AB800
6941AB1000

CONDUCTOR
NO. OF WEIGHT OVERALLGLAND GLAND SINGLE TREFOIL
CLEAT CLEAT
SIZE(MM) STRANDING CORES (KG/KM) DIAMETER SIZECW SIZE
ALI BRASS A2
(MM)
(MM)
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
800.0
1000.0

19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.2
127/2.52
127/2.85
127/3.2

1
1
1
1
1
1
1
1
1
1
1
1
1

638
891
1166
1412
1800
2200
2800
3400
4450
5550
7100
9200
11270

17.70
19.60
21.50
23.10
26.00
28.00
32.00
33.00
38.00
43.00
47.00
55.00
58.80

20
25
25
25
32
32
40
40
40
50S
50
63S
63S

25
32
32
32
40
40
50S
50S
50
63S
63S
75S
75S

0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.4
1.6
1.8
2.0
TC9
TC10

376AC04
376AC06
376AC06
376AC10
376AC13
376AC15
376AC20
376AC22

Temperature limits:
- 25 to + 90C
*Bending radius:
6 x Overall Diameter
Core identification:
Brown inner - Black outer
Should not be installed at
temperatures below 0C or
above +40C.

XLPE INSULATED
LOW SMOKE ZERO
HALOGEN SINGLE CORE
ARMOURED MAINS CABLE
(50MM2 TO 1000MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES LSZH

SINGLE CORE ARMOURED MAINS CABLES LSZH

FIXED WIRING AND MAINS CABLES LSZH

42

SCREENED FIXED WIRING AND MAINS CABLES TO BS 8436


Plain annealed stranded copper, XLPE insulated, tinned annealed stranded
copper earth wire, bonded aluminium tube applied longitudinally, low smoke
and zero halogen (LSZH) outer sheath, to BS EN 50267-1:1998 and BS EN
50268-2:2000, UV Stable. 600/1000v to BS8436, White. Acid gas emissions to
BS EN 50267-2-1, smoke emissions to BS EN 50268-2 and flame retardant to
BS EN 60332-1-2 (IEC 60332-1-1).
CCC
CODE
FSX2X1WH
FSX3X1WH
FSX4X1WH
FSX2X1/5WH
FSX3X1/5WH
FSX4X1/5WH
FSX2X2/5WH
FSX3X2/5WH
FSX4X2/5WH
FSX2X4WH
FSX3X4WH
FSX4X4WH
FSX2X6WH
FSX3X6WH
FSX4X6WH
FSX2X10WH

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5
4
4
4
6
6
6
10

NO. OF
CORES

7/0.44
7/0.44
7/0.44
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35

2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
85
8.60
105
9.40
130
10.00
106
9.80
140
10.40
158
11.30
135
10.80
182
11.10
259
12.60
206
11.50
265
13.10
320
13.90
258
13.10
328
14.20
450
14.90
413
16.1

1 HOLE
CLIP
REF
RCHL34
RCHL37
RCHL37
RCHL37
RCHL40
RCHL43
RCHL43
RCHL43
RCHL47
RCHL43
RCHL51
RCHL54
RCHL51
RCHL54
RCHL59
RCHL63

GLAND
REF
20SA2
20SA2
20A2
20A2
20A2
20A2
20A2
20A2
20A2
20A2
25A2
25A2
25A2
25A2
25A2
25A2

Minimum installation temperature:


-10C.
Maximum continuous conductors
operating temperature:
+90C.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Solid cores available on request.
Different sheath and core colours
available on request.
10mm2 and 16mm2 available
on request
Also available in 300/500 volt rating.

MECHANICALLY
PROTECTED
WIRING CABLE

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

43

FIXED WIRING AND MAINS CABLES

FIXED WIRING
AND MAINS
CABLES 11000V,
22000V,
AND
33000V

FIXED WIRING AND MAINS CABLES

44

SINGLE CORE ARMOURED MAINS CABLES PVC 11000V


Stranded plain annealed circular compacted copper conductors, XLPE
insulated, semi-conducting tape insulated, copper tape screen, PVC bedding,
aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade to
BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath
can be prone to fading when exposed to U.V rays.
CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM
CODE SIZE (MM2) (MM)
CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION
(MM)
(MM)
REFERENCE
10001
50
19/1.78
1
1200
28.7
32
12 376AC04 EPKT 17B1XI
10002
70
19/2.14
1
1461
30.5
32
14 376AC05 EPKT 17B1XI
10003
95
19/2.52
1
1761
32.2
32
14 376AC06 EPKT 17C1XI
10004
120
37/2.03
1
2049
33.8
40
14 376AC07 EPKT 17C1XI
10005
150
37/2.25
1
2451
36.2
40
16 376AC08 EPKT 17C1XI
10006
185
37/2.52
1
2848
37.9
40
16 376AC09 EPKT 17C1XI
10007
240
61/2.25
1
3470
40.4
50S
16 376AC11 EPKT 17C1XI
10008
300
61/2.52
1
4103
42.6
50S
18 376AC12 EPKT 17D1XI
10009
400
61/2.85
1
4995
45.6
50S
18 376AC14 EPKT 17D1XI
10010
500
61/3.20
1
6320
50
50
20 376AC17 EPKT 17E1XI
10011
630
127/2.52
1
7840
54
63S
TC9 376AC19 EPKT 17E1XI

SINGLE CORE
(50MM2 TO 630MM2)
AND 3 CORE
(25MM2 TO 400MM2)
XLPE INSULATED MEDIUM
VOLTAGE MAINS CABLES
11000 VOLT

Temperature limits:
up to 90C.
*Bending radius:

Should not be installed at


temperatures below 0C or
above +60C.

12 x overall diameter.
Core identification:
Brown.

3 CORE MAINS CABLES PVC 11000V


Stranded plain annealed circular compacted copper conductors, XLPE insulated,
semi-conducting tape insulated, each core copper tape screened, PVC bedding,
galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade
to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer
sheath can be prone to fading when exposed to U.V rays.
CCC
CODE

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE RAYCHEM


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE CLEAT TERMINATION
(MM)
(MM)
REFERENCE
11KV XLPE3X25RD
25
7/2/14
3
4300
48.4
50
2.0 EPKT 17A3XIH2
11KV XLPE3X35RD
35
19/1/53
3
4491
50.5
50
2.0 EPKT 17B3XIH2
11KV XLPE3X50RD
50
19/1/78
3
5105
53.3
63S
TC9 EPKT 17B3XIH2
11KV XLPE3X70RD
70
19/2/14
3
6019
56.9
63S
TC9 EPKT 17B3XIH2
11KV XLPE3X95RD
95
19/2/52
3
7148
61
63
TC10 EPKT 17C3XIH2
11KV XLPE3X120RD
120
37/2/03
3
8199
64.6
75S TC11 EPKT 17C3XIH2
11KV XLPE3X150RD
150
37/2/25
3
9274
67.8
75S TC11 EPKT 17C3XIH2
11KV XLPE3X185RD
185
37/2/52
3
10706
71.9
75
TC12 EPKT 17C3XIH2
11KV XLPE3X240RD
240
61/2/25
3
13740
78.8
90
TC14 EPKT 17C3XIH2
11KV XLPE3X300RD
300
61/2/52
3
16051
84.1
90
TC14 EPKT 1D3XIH2
11KV XLPE3X400RD
400
61/2/85
3
19095
90.3
TC15 EPKT 17D3XIH2

Temperature limits:
up to 90C.
*Bending radius:

Should not be installed at


temperatures below 0C or
above +60C.

12 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

45

Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape


insulated, each core copper tape screened, PVC bedding (extruded), galvanised
steel wire armour, PVC outer sheath. Red. 6350/11000 volts grade to BS6622
and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be
prone to fading when exposed to U.V rays.
CCC
CODE
10115RD
10116RD
10117RD
10118RD
10119RD
10120RD

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE CLEAT
(MM)
(MM)
95
19/2.52
3
5800
62.6
63
TC10
120
37/2.03
3
6400
66.6
75S TC11
150
37/2.25
3
7000
68.6
75S TC11
185
37/2.52
3
7800
74.1
75
TC12
240
61/2.25
3
9800
81.2
90
TC14
300
61/2.52
3
11000
86.8
90
TC15

RAYCHEM
TERMINATION
REFERENCE
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17D3XIH2

Temperature limits:
up to 90C.
*Bending radius:
13 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0C or
above +60C.

XLPE INSULATED
MEDIUM VOLTAGE
MAINS CABLE
11000 VOLT
(95MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES

3 CORE MAINS CABLES PVC 11000V

FIXED WIRING AND MAINS CABLES

46

TRIPLEX CABLES 11000V


Solid or stranded aluminium conductor, XLPE insulated, copper wire screen
(35mm2). MDPE outer sheath. Red. 6350/11000 volts grade to BS7870.
Red outer sheath can be prone to fading when exposed to U.V rays.
CCC
CODE

CONDUCTOR CONDUCTOR NOMINAL


SIZE (MM2)
TYPE
CONDUCTOR
DIAMETER
11KVTRIP3X70AL
70
SOLID
9.30
11KVTRIP3X70AL
70
STRANDED
9.80
11KVTRIP3X95AL
95
SOLID
10.70
11KVTRIP3X95AL
95
STRANDED
12.16
11KVTRIP3X185AL
185
SOLID
14.90
11KVTRIP3X185AL
185
STRANDED
15.80
11KVTRIP3X300AL
300.0
SOLID
19.00
11KVTRIP3X300AL
300.0
STRANDED
20.50

NO. OF
CORES

WEIGHT
KG/KM

3
3
3
3
3
3
3
3

2763
2650
3055
2901
4095
4060
5374
5360

DIAMETER
IN TRIPLEX
FORMATION
57.4
58.3
60.8
57.83
70.5
72.5
80.4
81.4

Temperature limits:
-15 to +90C.
*Bending radius:
15 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0C.

3 CORE UTILITY CABLE


TRIPLEX FORMATION XLPE
INSULATED
MEDIUM VOLTAGE CABLE
11000 VOLT
(70MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

47

COPPER CONDUCTOR
Plain annealed copper conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound
bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000
volts grade to BS6480/88. Flame propagation to BS EN 60332. Red outer
sheath can be prone to fading when exposed to U.V rays.
CCC
CODE
PILC3X25RD
PILC3X35RD
PILC3X50RD
PILC3X70RD
PILC3X95RD
PILC3X120RD
PILC3X150RD
PILC3X185RD
PILC3X240RD
PILC3X300RD
PILC3X400RD

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
35
50
70
95
120
150
185
240
300
400

7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85

No. OF
CORES
3
3
3
3
3
3
3
3
3
3
3

Temperature limits:
up to 65C.
*Bending radius:

PAPER INSULATED
MEDIUM VOLTAGE
MAINS CABLE
11000 VOLT
(25MM2 TO 400MM2)

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
5230
43.6
5890
42.3
6620
45.6
7820
49.7
9240
53.3
10400
56.2
11770
59.2
13550
62.8
16390
67.8
19870
73.6
23700
79.4

SINGLE RAYCHEM
CLEAT TERMINATION
REFERENCE
1.8 EPKT 17A3MIH2
2.0 EPKT 17B3MIH2
2.0 EPKT 17B3MIH2
2.0 EPKT 17B3MIH2
TC9 EPKT 17C3MIH2
TC9 EPKT 17C3MIH2
TC10 EPKT 17C3MIH2
TC10 EPKT 17C3MIH2
TC11 EPKT 17C3MIH2
TC12 EPKT 17D3MIH2
TC14 EPKT 17D3MIH2

Should not be installed at


temperatures below 0C or
above +60C.

13 x overall diameter.
Core identification:
White printed numbers on
insulating papers.
ALUMINIUM CONDUCTOR
Plain aluminium stranded conductors, paper insulated, paper belted, semiconducting carbon paper tape bedding, lead sheathed, textile compound
bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000
volts grade to BS6480/88. Flame propagation to BS EN 60332.
Red outer sheath can be prone to fading when exposed to U.V rays.
CCC
CODE
10100RD
10103RD
10105RD

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
95
185
300

19/2.52
37/2.52
61/2.52

No. OF
CORES
3
3
3

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
7115
53.2
9521
63.5
13403
71.5

SINGLE RAYCHEM
CLEAT TERMINATION
REFERENCE
TC9 EPKT 17C3MIH2
TC11 EPKT 17C3MIH2
TC12 EPKT 17D3MIH2

Temperature limits:
up to 65C.
*Bending radius:

Core identification:
White printed numbers on
insulating papers.

13 x overall diameter.

Should not be installed at


temperatures below 0C or
above +60C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES

PAPER INSULATED MAINS CABLES PVC 11000V

FIXED WIRING AND MAINS CABLES

48

SINGLE CORE ARMOURED MAINS CABLES LSZH 11000V


Stranded plain annealed compacted circular copper conductor, XLPE insulated,
semi-conducting tape insulated, copper tape screen, low smoke and zero halogen
(LSZH) bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer
sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN
50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame
propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor U.V resistant
qualities, red outer sheath cables are not recomended for outdoor installation.

SINGLE CORE
(50MM2 TO 630MM2)
AND 3 CORE
(25MM2 TO 400MM2)
XLPE INSULATED LOW
SMOKE ZERO HALOGEN
MEDIUM VOLTAGE MAINS
CABLES 11000 VOLT

CCC CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE TREFOIL RAYCHEM
CODE SIZE (MM2) (MM)
CORES KG/KM DIAMETER SIZE CLEAT CLEAT TERMINATION
(MM)
(MM)
REFERENCE
10050
50
19/1.78
1
1200
28.7
32
12 376AC04 EPKT 17B1XI
10051
70
19/2.14
1
1461
30.5
32
14 376AC05 EPKT 17B1XI
10052
95
19/2.52
1
1761
32.2
32
14 376AC06 EPKT 17C1XI
10053
120
37/2.03
1
2049
33.8
40
14 376AC07 EPKT 17C1XI
10054
150
37/2.25
1
2451
36.2
40
16 376AC08 EPKT 17C1XI
10055
185
37/2.52
1
2848
37.9
40
16 376AC09 EPKT 17C1XI
10056
240
61/2.25
1
3470
40.4
50S
16 376AC11 EPKT 17C1XI
10057
300
61/2.52
1
4103
42.6
50S
18 376AC12 EPKT 17D1XI
10058
400
61/2.85
1
4995
45.6
50S
18 376AC14 EPKT 17D1XI
10059
500
61X3.20
1
6320
50
50
20 376AC17 EPKT 17E1XI
10060
630
127X2.52
1
7840
54
63S
TC9 376AC19 EPKT 17E1XI

Temperature limits:
up to 90C.
*Bending radius:

Should not be installed at


temperatures below 0C or
above +40C.

15 x overall diameter.
Core identification:
Brown.

3 CORE MAINS CABLES LSZH 11000V


Stranded plain annealed compacted circular copper conductors, XLPE
insulated, semi-conducting tape insulated, each core copper tape screened,
low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour,
low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts
grade to BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke
emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265,
BS EN 50266 (IEC 60332). Due to poor U.V resistant qualities red outer sheath
cables are not recomended for outdoor installation.
CCC
CODE
10302RD
10304RD
10306RD
10308RD
10310RD
10312RD
10314RD
10316RD
10318RD
10320RD

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND SINGLE


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE CLEAT
(MM)
(MM)
35
19/1.53
3
4501
50.5
50
TC9
50
19/1.78
3
5117
53.3
63S
TC9
70
19/2.14
3
6032
56.9
63S
TC9
95
19/2.52
3
7163
61
63
TC10
120
37/2.03
3
8216
64.6
75S TC11
150
37/2.25
3
9292
67.8
75
TC11
185
37/2.52
3
10726
71.9
75
TC12
240
61/2.25
3
13763
78.8
90
TC14
300
61/2.52
3
16077
84.1
90
TC14
400
70/3.15
3
19124
90.3
TC15

Temperature limits:
up to 90C.
*Bending radius:

RAYCHEM
TERMINATION
REFERENCE
EPKT 17B3XIH2
EPKT 17B3XIH2
EPKT 17B3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17C3XIH2
EPKT 17D3XIH2
-

Should not be installed at


temperatures below 0C or
above +40C.

12 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

49

Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen,
extruded low smoke zero halogen(LSZH) bedding, galvanised steel wire
armour, extruded low smoke zero halogen (LSZH) sheath - Red. 12700/22000
volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath
cables are not recommended for outdoor installation.

CCC CODE

CONDUCTOR
SIZE (MM)
22KVXLPE3X95RD
95.0

STRANDING
19/2.52

Temperature limits:
- 15 to + 90C

NO. OF
CORES
3

WEIGHT
(KG/KM)
8820

OVERALL
DIAMETER
70.30

Should not be installed at


temperatures below 0C or
above +40C.

*Bending radius:
12 x overall diameter
Core identification:
Brown, Black, Grey tapes.

Compacted circular stranded annealed copper conductor, extruded semiconductive conductor screen, XLPE insulated, extruded strippable semiconductive insulation screen helically overlapped copper tape metallic screen,
extruded low smoke zero halogen(LSZH) bedding, galvanised steel wire
armour, extruded low smoke zero halogen (LSZH) sheath - Red. 19000/33000
volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath
cables are not recommended for outdoor installation.
CCC
CONDUCTOR
CODE
SIZE (MM)
33KVLSF3X95RD
95.0
33KVLSF3X185RD
185.0

Temperature limits:
- 15 to + 90C
*Bending radius:

STRANDING
19/2.52
37/2.52

NO. OF
CORES
3
3

WEIGHT
(KG/KM)
12020
20000

OVERALL
DIAMETER
85.30
96.00

Should not be installed at


temperatures below 0C or
above +40C.

12 x overall diameter
Core identification:
Brown, Black, Grey tapes.

3 CORE XLPE INSULATED


LOW SMOKE ZERO
HALOGEN MEDIUM
VOLTAGE MAINS CABLE
22000 VOLT (95MM2)
AND 33000 VOLT
(95MM2 / 185MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES

THREE CORE MAINS CABLES 22KV AND 33KV

51

FIXED WIRING AND MAINS CABLES

FIXED WIRING AND


MAINS CABLES
33000V - SERVICE
AND WINDFARM

FIXED WIRING AND MAINS CABLES

52

SINGLE CORE MAINS CABLE MDPE 33000V


WINDFARM CABLE
Round stranded compacted aluminium conductor, inner semi-conductive layer
XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape
insulation screen, copper wire and tape metallic screen (35mm2), polyester
tape/water blocking swelling tape seperator, extruded black MDPE outer
sheath. 33000 volts grade to BS7870, IEC 60502-2.
CCC CODE
33KV1X70AL
33KV1X95AL
33KV1X120AL
33KV1X150AL
33KV1X185AL
33KV1X240AL
33KV1X300AL
33KV1X400AL
33KV1X500AL
33KV1X630AL

CONDUCTOR
SIZE (MM)
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0

STRANDING
19/2.1
19/2.47
35/2.04
35/2.27
35/2.54
35/2.91
35/3.25
56/2.91
56/3.3
56/3.75

Rated voltage Uo/U


Max operating voltage
Test voltage
Partial discharge level with voltage 2Uo Kv
Max. perm conductor temperature
Max. perm operating temperature
Short circuit temperature
*Minimum bending radius

SINGLE CORE 33000 VOLT


RATED WINDFARM CABLE
ALUMINIUM CONDUCTOR
(70MM TO 630MM)

NO. OF
CORES
1
1
1
1
1
1
1
1
1
1

WEIGHT
(KG/KM)
1339
1467
1584
1720
1881
2130
2381
2723
3146
3675

OVERALL
DIAMETER
36.70
38.40
39.80
41.30
43.00
45.50
47.80
50.80
54.30
58.90

19/33 Kv
36 kv
75 kv
max. 5pC
90C
130C
250C
12 x overall diameter

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

53

Round stranded compacted copper conductor, inner semi-conductive layer


XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape
insulation screen, copper wire and tape metallic screen (35mm2), polyester
tape/water blocking swelling tape seperator, extruded black MDPE outer
sheath. 33000 volts grade to BS7870, IEC 60502-2.
CCC
CONDUCTOR
CODE
SIZE (MM)
33KVCU1X70BK
70.0
33KVCU1X95BK
95.0
33KVCU1X120BK
120.0
33KVCU1X150BK
150.0
33KVCU1X185BK
185.0
33KVCU1X240BK
240.0
33KVCU1X300BK
300.0
33KVCU1X400BK
400.0
33KVCU1X500BK
500.0
33KVCU1X630BK
630.0

STRANDING
19/2.11
19/2.48
35/2.05
35/2.28
35/2.55
35/2.92
35/3.28
56/2.93
56/3.32
56/3.77

Rated voltage Uo/U


Max operating voltage
Test voltage
Partial discharge level with voltage
Max. perm conductor temperature
Max. perm operating temperature
Short circuit temperature
*Minimum bending radius

SINGLE CORE 33000 VOLT


RATED SERVICE CABLE
COPPER CONDUCTOR
(70MM TO 630MM)

NO. OF
CORES
1
1
1
1
1
1
1
1
1
1

WEIGHT
(KG/KM)
1751
2043
2309
2614
2997
3596
4225
5069
6156
7570

OVERALL
DIAMETER
36.50
38.20
39.60
41.20
42.90
45.40
47.80
50.60
53.90
57.60

19/33 Kv
36 kv
75 kv
2Uo Kv max. 5pC
90C
130C
250C
12 x overall diameter

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIXED WIRING AND MAINS CABLES

SINGLE CORE MAINS CABLE MDPE 33000V


SERVICE CABLE

55

FIREPROOF CABLES

FIREPROOF CABLES

FIREPROOF CABLES

56

FIREPROOF CABLES - MINERAL INSULATED


Solid plain annealed copper conductors, magnesium oxide insulated, solid copper
sheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options:
(a) Light Duty = 500 volts grade
Heavy Duty = 1000 volts grade

(b) Outer sheath finishes, bare copper,


PVC or LSZH
(c) Outer sheath colours. Orange, Red,
White or Black.

SIZE
REF.
2L1.0
2L1.5
2L2.5
2L4.0
3L1.0
3L1.5
3L2.5
4L1.0
4L1.5
4L2.5
7L1.5
7L2.5
1H6.0
1H10
1H16
1H25
1H35
1H50
1H70
1H95
1H120
1H150
1H240
2H1.5
2H2.5
2H4.0
2H6.0
2H10
2H16
2H25
3H1.5
3H2.5
3H4.0
3H6.0
3H10
3H16
3H25
4H1.5
4H2.5
4H4.0
4H6.0
4H10
4H16
4H25
7H1.5
7H2.5
12H2.5
19H1.5

BARE SHEATHED OVERALL OVERALL GLAND


KG/KM
KG/KM DIAMETER DIAMETER FOR USE
BARE SHEATHED WITH RPS
(MM)
(MM)
SEALS
104.0
125.00
5.1
6.6
20
136.0
159.00
5.7
7.2
20
187.0
213.00
6.6
8.1
20
248.0
282.00
7.7
9.4
20
136.0
159.00
5.8
7.3
20
176.0
201.00
6.4
7.9
20
223.0
256.00
7.3
9
20
162.0
187.00
6.3
7.8
20
203.0
230.00
7
8.5
20
277.0
313
8.1
9.8
20
295.0
332
8.4
10.1
25
411.0
454
9.7
11.4
25
173.0
213
6.4
7.7
20
240
273
7.3
9
20
326
361
8.3
10
20
457
499
9.6
11.3
20
585
632
10.7
12.4
20
758
810
12.1
13.8
25
1016
1075
13.7
15.4
25
1324
1413
15.4
17.7
25
1612
1709
16.8
19.1
32
1949
2055
18.4
20.7
32
3050
3213
23.3
26.1
40
237
272
7.9
9.6
20
276
314
8.7
10.4
20
355
397
9.8
11.5
20
446
493
10.9
12.6
20
619
673
12.7
14.4
25
850
912
14.7
16.4
25
1178
1277
17.1
19.4
32
254
290
8.3
10
20
323
364
9.3
11
20
415
460
10.4
12.1
20
526
575
11.5
13.2
25
754
812
13.6
15.3
25
1034
1124
15.6
17.9
25
1444
1549.00
18.2
20.5
40
305
345.00
9.1
10.8
20
384
428.00
10.1
11.8
20
507
556.00
11.4
13..1
25
644
698.00
12.7
14.4
25
911
974.00
14.8
16.5
25
1286
1386.00
17.3
19.6
32
1805
1947.00
20.1
22.9
40
432
479.00
10.8
12.5
25
559
611.00
12.1
13.8
25
911
1001.00
15.6
17.9
32
992
1088.00
16.6
18.9
40

Temperature limits:
PVC sheath -20 to +70C.
LSF sheath -20 to +80C.

MINERAL
INSULATED CABLE
(1.0MM2 TO 240MM2)

SINGLE HOLE CLIP NOMINAL


REFERENCE
STD DRUM
BARE SHEATHED LTHS (MTS)
20
22
26
30
22
24
28
24
28
32
32
37
34
28
32
37
40
47
54
59
63
71
88
30
34
37
43
47
54
67
32
37
40
43
54
59
71
37
40
43
47
54
67
79
43
47
59
63

26
28
32
37
28
30
34
30
34
37
40
43
34
34
37
43
47
54
59
67
75
79
101
37
40
43
47
54
63
75
37
43
47
51
59
71
79
43
47
51
54
63
75
88
47
54
71
71

500
500
500
500
500
500
500
500
500
500
380
285
650
510
400
275
222
170
190
155
135
110
67
500
500
500
500
500
112
80
500
500
500
184
130
100
70
500
500
195
144
110
89
60
245
195
148
112

*Bending radius:
6 x overall diameter.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

57

Plain annealed copper conductor, silicon rubber insulated aluminium/polyester


tape screen, tinned annealed copper earth wire, low smoke zero halogen (LSZH)
outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387.
Flame retardant to BS5839-1:2003 and IEC 60332-3 CAT CWZ, BS7629-1 1997.
Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268
(IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332).
CCC
CODE
FP2X1
FP3X1
FP4X1
FP7X1
FP12X1
FP2X1/ 5
FP3X1/ 5
FP4X1/5
FP7X1/5
FP12X1/5
FP19X1/5
FP2X2/5
FP3X2/5
FP4X2/5
FP7X2/5
FP12X2/5
FP19X2/5
FP2X4
FP3X4
FP4X4

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND


SIZE (MM2)
(MM)
CORES KG/KM DIAMETER SIZE CLIP REF REF
(MM)
(MM)
1.0
1/1.13
2+E
90
7.5
20
28
251
1.0
1/1.13
3+E
110
8.0
20
30
251
1.0
1/1.13
4+E
135
8.8
20
34
251
1.0
1/1.13
7+E
170
10.5
20
40
252
1.0
1/1.13
12+E
270
13.7
25
54
254
1.5
1/1.38
2+E
110
8.0
20
32
251
1.5
1/1.38
3+E
130
8.4
20
34
251
1.5
1/1.38
4+E
160
9.5
20
37
251
1.5
1/1.38
7+D
230
11.3
20
43
252
1.5
1/1.38
12+D
365
15.2
25
59
254
1.5
1/1.38
19+D
540
17.8
25
67
254
2.5
1/1.78
2+E
160
9.0
20
34
252
2.5
1/1.78
3+E
200
10.5
20
40
252
2.5
1/1.78
4+E
250
11.7
20
43
252
2.5
1/1.78
7+D
285
13.7
20
54
252
2.5
1/1.78
12+D
470
17.9
25
67
254
2.5
1/1.78
19+D
720
21.4
32
79
255
4.0
7/0.85
2+E
260
11.3
20
43
252
4.0
7/0.85
3+E
315
12.1
25
47
254
4.0
7/0.85
4+E
380
13.3
25
54
254

E = Bare earth conductor.


D = Drain wire
Temperature limits:
-10 to +80C.
*Bending radius:
6 x overall diameter.

FIRE RESISTANT
FIRE ALARM &
SECURITY CABLE
STANDARD
(1.0MM2 TO 4MM2)

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
7 core and above - White with Black numbers.
Should not be installed at temperatures
below 0C or above +40C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIREPROOF CABLES

STANDARD FIRE ALARM AND SECURITY


WIRING CABLES

FIREPROOF CABLES

58

ENHANCED FIRE ALARM AND SECURITY WIRING CABLES


Plain annealed copper conductor, enhanced silicon rubber insulated, enhanced
aluminium/polyester tape screen, tinned annealed copper earth wire,
enhanced low smoke zero halogen outer sheath. Red or white. Manufactured
to meet the Enhanced standard of BS5839-1 2002 +A2:2008 Clause 26.2e
Enhanced and also the requirements of BS8434 - 2:2003 120 minutes and BS
EN 50200 Class PH120. Fire resistant to BS7629-1:2008, BS6387:1994 clause
11 CWZ, halogen emissions to bs en 50267-2-1:1999 and low smoke standard
BS EN 61034-2:2005.
CCC
CODE
ENH2X1/5
ENH3X1/5
ENH4X1/5
ENH2X2/5
ENH3X2/5
ENH4X2/5
ENH2x4
ENH3x4
ENH4x4

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND 1 HOLE GLAND


(MM)
CORES KG/KM DIAMETER SIZE CLIP REF REF
SIZE (MM2)
(MM)
(MM)
1.5
1/1.38
2+E
110
8.0
20
32
251
1.5
1/1.38
3+E
130
8.4
20
34
251
1.5
1/1.38
4+E
160
9.5
20
37
251
2.5
1/1.78
2+E
160
9.0
20
34
252
2.5
1/1.78
3+E
200
10.5
20
40
252
2.5
1/1.78
4+E
250
11.7
20
43
252
4.0
7/0.85
2+E
260
11.3
20
43
252
4.0
7/0.85
3+E
315
12.1
25
47
254
4.0
7/0.85
4+E
380
13.3
25
51
254

E = Bare earth conductor.


Temperature limits:
-40 to +90C.
*Bending radius:
6 x overall diameter.

FIRE RESISTANT
FIRE ALARM &
SECURITY CABLE
ENHANCED
(1.5MM2 TO 4MM2)

Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at temperatures
below 0C or above +40C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

59

Plain annealed copper conductor, mica fire resistant tape, low smoke zero
halogen (LSZH) insulation. 600/1000 volts grade. Fire resistant to IEC 331 and
BS6387, CWZ when tested in steel conduit. Manufactured to meet the
following standards - acid gas emission to BS EN 50267, flame retardant to BS
EN 60332-1-2 and smoke emission to BS7211.
CCC
CODE
6491F1/5
6491F2/5
6491F4
6491F6
6491F10
6491F16

CONDUCTOR
SIZE (MM)
1.5
2.5
4.0
6.0
10.0
16.0

STRANDING
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70

NO. OF
CORES
1
1
1
1
1
1

WEIGHT
(KG/KM)
32
43
55
85
146
198

OVERALL
DIAMETER
3.30
3.75
4.30
5.00
6.80
8.00

Temperature limits:
- 40 to + 90C
*Bending radius:
8 x Overall Diameter
Standard colours available:
Brown, Blue, Grey, Black,
Green/Yellow.
Should not be installed at
temperatures below 0C or
above 40C.

FIRE RESISTANT
SINGLE CORE CABLES
(1.5MM2 TO 16MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIREPROOF CABLES

FIREPROOF CABLES - SINGLES

FIREPROOF CABLES

60

FIREPROOF MAINS AND CONTROL CABLES LSZH


Plain annealed stranded copper conductor, mica fire resistant tape, XLPE
insulated, low smoke & zero halogen (LSZH) bedding, galvanised steel wire
armour, low smoke & zero halogen (LSZH) outer sheath. Black. 600/1000 volts.
Fire resistant to IEC 331 & BS7846 F2 / BS6387 & CWZ. Acid gas emission to
BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and
flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3).
CCC
CODE
6942F1/5
6943F1/5
6944F1/5
6947F1/5
6940/12F1/5
6940/19F1/5
6940/27F1/5
6940/37F1/5
6942F2/5
6943F2/5
6944F2/5
6947F2/5
6940/12F2/5
6940/19F2/5
6940/27F2/5
6940/37F2/5
6942F4
6943F4
6944F4
6945F4
6947F4
6942F6
6943F6
6944F6
6945F6
6942F10
6943F10
6944F10
6945F10
6942F16
6943F16
6944F16
6945F16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
6
6
6
6
10
10
10
10
16
16
16
16

NO. OF
CORES

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70

2
3
4
7
12
19
27
37
2
3
4
7
12
19
27
37
2
3
4
5
7
2
3
4
5
2
3
4
5
2
3
4
5

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
295
12.00
324
12.50
367
13.30
463
15.30
791
20.00
1030
22.90
1534
27.90
1849
30.70
352
13.10
392
13.70
454
14.70
584
17.00
1003
22.50
1525
27.00
1990
31.60
2435
34.80
424
14.10
478
14.80
556
16.00
725
18.12
852
19.50
504
15.20
573
16.00
783
18.20
865
19.65
620
16.90
868
18.50
1029
20.00
1222
22.64
954
19.50
1136
20.80
1367
22.50
1812
26.55

GLAND
SIZE
(MM)
20/16
20/16
20S
20S
25
25
32
32
20S
20S
20S
20
25
32
32
40
20S
20S
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25

SINGLE
CLEAT
0.5
0.6
0.6
0.7
0.8
1.0
1.2
1.4
0.6
0.6
0.6
0.7
0.9
1.1
1.4
1.4
0.6
0.6
0.7
0.8
0.8
0.7
0.7
0.8
0.8
0.7
0.8
0.8
0.9
0.8
0.9
0.9
1.1

Temperature limits:
-40 to +90C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core and above 4mm2 and 6mm2 White with Black numbers.
5 core - 10mm2 and 16mm2 - Brown,
Black, Grey, Blue, Green/Yellow.
Should not be installed at
temperatures below 0C or
above 40C.

FIRE RESISTANT POWER


AND CONTROL CABLE
(1.5MM2 TO 16MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

61

Plain annealed stranded copper conductor, mica fire resistant tape, XLPE
insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire
armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts
grade. Fire resistant to BS6387/BS7846 F2 & CWZ. Acid gas emission to BS EN
50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame
propagation to BS EN 50265, BS EN 50266 (IEC 60332-3).
CCC
CODE
FP2X25
FP3X25
FP4X25
FP5X25
FP2X35
FP3X35
FP4X35
FP2X50
FP3X50
FP4X50
FP2X70
FP3X70
FP4X70
FP2X95
FP3X95
FP4X95
FP2X120
FP3X120
FP4X120
FP2X150
FP3X150
FP4X150
FP2X185
FP3X185
FP4X185
FP2X240
FP3X240
FP4X240
FP2X300
FP3X300
FP4X300
FP3X400
FP4X400

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400

7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85

NO. OF
CORES
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
1100
21.4
1800
26.6
2150
28.8
2700
32
1550
24.3
2200
29.1
2650
31.6
1850
26.8
2450
29.6
3100
33.2
2450
30
3200
33.3
4400
38.9
3350
34.1
4450
38.1
5650
42.9
3900
37.1
5300
41.5
7250
48.3
4650
40.3
6700
46.6
8550
52.6
5950
45.7
8050
50.9
10300
57.8
7350
50
9950
56.2
12900
64.2
8700
54.5
12050
61.3
15550
70
14800
67.7
20250
79.3

GLAND
SIZE
(MM)
25
32
32
32
25
32
32
32
32
40
32
40
40
40
40
50S
40
50S
50
50S
50
50
50
50
63S
50
63S
63
63S
63
75S
75S
90

SINGLE
CLEAT
0.9
1.1
1.2
1.4
1.0
1.2
1.4
1.1
1.2
1.4
1.4
1.4
1.6
1.4
1.6
1.8
1.6
1.8
2.0
1.8
2.0
TC9
2.0
TC9
TC10
TC9
TC9
TC11
TC9
TC10
TC12
TC11
TC14

Temperature limits:
-40 to +90C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0C or
above 40C.

FIRE RESISTANT
POWER CABLE
(25MM2 TO 400MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIREPROOF CABLES

FIREPROOF MAINS CABLES LSZH

FIREPROOF CABLES

62

FIREPROOF MAINS AND CONTROL CABLES


LSZH - ENHANCED
Plain annealed stranded copper conductor, mica fire resistant tape, XLPE
insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier
tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer
sheath.Black. 600/1000 grade volts. Manufactured to meet the following
standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas
emission to IEC 60754, BS EN 50267, flame propagation to IEC 60332-3, BS EN
50265, BS EN50266 and smoke emission to IEC 61034, BS EN 50268.
CCC
CODE
FPE2X4
FPE3X4
FPE4X4
FPE2X6
FPE3X6
FPE4X6
FPE2X10
FPE3X10
FPE4X10
FPE2X16
FPE3X16
FPE4X16

CONDUCTOR
SIZE (MM) STRANDING
4.0
7/0.85
4.0
7/0.85
4.0
7/0.85
6.0
7/1.04
6.0
7/1.04
6.0
7/1.04
10.0
7/1.35
10.0
7/1.35
10.0
7/1.35
16.0
7/1.7
16.0
7/1.7
16.0
7/1.7

Temperature limits:
- 40 to + 90C
*Bending radius:

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4

WEIGHT OVERALL GLAND


(KG/KM) DIAMETER SIZE (MM)
871
21.80
25
966
22.70
25
959
24.00
25
1001
23.00
25
1087
23.80
25
1252
25.20
25
1060
23.80
20
1180
24.80
25
1350
27.40
32
1290
25.90
25
1460
27.10
32
1690
28.98
32

SINGLE
CLEAT
0.9
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.2

Should not be installed at


temperatures below 0C or
above 40C.

8 x Overall Diameter
Core identification:
2 core - Brown. Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.

FIRE RESISTANT POWER


AND CONTROL
CABLE - ENHANCED
(4MM2 TO 16MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

63

Plain annealed stranded copper conductor, mica fire resistant tape, XLPE
insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier
tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer
sheath.Black. 600/1000 grade volts. Manufactured to meet the following
standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas
emission to IEC 60754, BS EN 50267, flame propagation to IEC 60332-3, BS EN
50265, BS EN50266 and smoke emission to IEC 61034, BS EN 50268.
CCC
CODE
FPE2X25
FPE3X25
FPE4X25
FPE2X35
FPE3X35
FPE4X35
FPE2X50
FPE3X50
FPE4X50
FPE2X70
FPE3X70
FPE4X70
FPE2X95
FPE3X95
FPE4X95
FPE2X120
FPE3X120
FPE4X120
FPE2X150
FPE3X150
FPE4X150
FPE2X185
FPE3X185
FPE4X185
FPE2X240
FPE3X240
FPE4X240
FPE2X300
FPE3X300
FPE4X300
FPE3X400
FPE4X400

CONDUCTOR
SIZE (MM) STRANDING
25
7/2.14
25
7/2.14
25
7/2.14
35
7/2.52
35
7/2.52
35
7/2.52
50
19/1.78
50
19/1.78
50
19/1.78
70
19/2.14
70
19/2.14
70
19/2.14
95
19/2.52
95
19/2.52
95
19/2.52
120
37/2.03
120
37/2.03
120.0
37/2.03
150.0
37/2.25
150.0
37/2.25
150.0
37/2.25
185.0
37/2.52
185.0
37/2.52
185.0
37/2.52
240.0
61/2.25
240.0
61/2.25
240.0
61/2.25
300.0
61/2.52
300.0
61/2.52
300.0
61/2.52
400.0
61/2.85
400.0
61/2.85

Temperature limits:
- 40 to + 90C
*Bending radius:

NO. OF
CORES
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4

WEIGHT OVERALL GLAND


(KG/KM) DIAMETER SIZE (MM)
1640
29.00
32
2070
31.10
32
2410
33.40
40
2130
31.90
32
2480
33.50
40
2920
36.10
40
2030
29.90
32
2630
33.20
40
3280
37.10
40
2580
33.30
40
3400
37.00
40
4570
45.50
50
3440
37.20
40
4550
41.20
50S
5720
46.40
50
4050
39.90
50S
5410
44.40
50S
7270
51.20
50
4740
43.10
50S
6800
49.30
50
8580
55.70
63S
6050
48.10
50
8140
53.70
63S
10300
60.80
63
7390
52.40
50
10040
58.80
63
12800
66.50
75S
8760
56.50
63S
12020
63.50
63
15410
72.10
75
14820
70.10
75S
19910
81.30
90

SINGLE
CLEAT
1.2
1.4
1.6
1.4
1.4
1.6
1.2
1.4
1.6
1.4
1.6
1.8
1.6
1.8
2.0
1.6
1.8
TC9
1.8
2.0
TC9
2.0
TC9
TC10
TC9
TC10
TC11
TC9
TC10
TC12
TC12
TC14

Should not be installed at


temperatures below 0C or
above 40C.

8 x Overall Diameter
Core identification:
2 core - Brown. Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.

FIRE RESISTANT POWER


AND CONTROL
CABLE - ENHANCED
(25MM2 TO 400MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FIREPROOF CABLES

FIREPROOF MAINS CABLES LSZH - ENHANCED

65

FLEXIBLE CABLES

FLEXIBLE CABLES

FLEXIBLE CABLES

66

PVC INSULATED FLEXIBLE CORDS 218*Y - 318*Y


Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath.
Black or White. 300/500 volts grade to BS6500. (Harmonized code HO5VV-F).
Flame propagation to BS EN 50265.
CCC
CODE
**2182Y/5
**2182Y/75
**2183Y/5
**2183Y/75
3182Y/5
3183Y/5
3182Y/75
3183Y/75
3184Y/75
3185Y/75
3182Y1
3183Y1
3184Y1
3185Y1
3182Y1/5
3183Y1/5
3184Y1/5
3185Y1/5
3182Y2/5
3183Y2/5
3184Y2/5
3185Y2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.75
0.5
0.75
0.5
0.5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5

16/0.2
24/0.2
16/0.2
24/0.2
16/0.2
16/0.2
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25

Temperature limits:
Fixed - -5 to +60C.
Flexing - +5 to +60C.
*Bending radius:
Fixed 2 x overall diameter.
Flexing 6 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
2
3
3
2
3
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5

36
45
44
55
52
54
59
70
85
110
69
82
105
130
95
120
150
180
145
180
220
265

OVERALL
DIAMETER
(MM)
5.4
5.8
5.6
6.1
6.3
6.3
6.8
7.2
7.7
8.5
7.2
7.6
8.5
9.1
8.2
8.9
10.0
11.0
9.9
10.8
11.3
12.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20/16
20S
20S
20
20S
20S
20
20

Should not be installed at


temperatures below 0C.
**Light flexible cords
300/300 volts grade

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.

PVC INSULATED
FLEXIBLE CORDS
TYPE 218*Y & 318*Y
(0.5MM2 TO 2.5MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

67

Plain annealed flexible copper conductors heat resisting PVC outer sheath.
White 300/500 volts grade to BS6141. Flame propagation to BS EN 50265.
CCC
CODE
3092Y/5
3093Y/5
3094Y/5
3092Y/75
3093Y/75
3094Y/75
3095Y/75
3092Y1
3093Y1
3094Y1
3092Y1/5
3093Y1/5
3094Y1/5
3092Y2/5
3093Y2/5
3094Y2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5

16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
5
2
3
4
2
3
4
2
3
4

46
66
70
56
68
85
104
65
77
100
80
100
130
135
150
195

Temperature limits:
Fixed - -5 to +90C.
Flexing - +5 to +90C.

PVC INSULATED
FLEXIBLE CORDS
TYPE 309*Y
(0.5MM2 TO 2.5MM2)
AND ARTIC GRADE
(1.5MM2 TO 4MM2)

OVERALL
DIAMETER
(MM)
6.3
6.5
7.2
6.8
7.2
7.7
8.5
7.2
7.6
8.5
8.2
8.9
10.0
10.0
10.8
11.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20S
20S
20S
20S
20S
20S
20S
20
20S
20
20

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow.

*Bending radius:
Fixed - 2 x overall diameter.
Flexing - 6 x overall diameter.

Should not be installed at


temperatures below 0C.

ARCTIC GRADE FLEXIBLE CORDS


Plain annealed flexible copper conductors, low temperature PVC insulation, low
temperature PVC outer sheath. Blue or Yellow. 300/500 volts grade to BS7919 table
44 and BS6500. Flame propagation to BS EN 50265.
CCC
CODE
3183AG1/5
3184AG1/5
3183AG2/5
3184AG2/5
3183AG4
3183AG6

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5
4
6

Temperature limits:
Flexing - 40 to + 70C
*Bending radius:
6 x overall diameter.

30/0.25
30/0.25
50/0.25
50/0.25
56/0.30
76/0.30

NO. OF
CORES

WEIGHT
KG/KM

3
4
3
4
3
3

90
130
180
220
240
315

OVERALL
DIAMETER
(MM)
8.20
9.55
10.15
11.30
11.40
13.2

GLAND
SIZE
(MM)
20S
20S
20S
20
20
20

Core identification:
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

PVC INSULATED FLEXIBLE CORDS 309*Y

FLEXIBLE CABLES

68

ZERO HALOGEN FLEXIBLE CORDS (HO5 ZIZI-F)


Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated,
low smoke and zero halogen (LSZH) outer sheath. Black or white. 300/500 volts
grade (Generally to BS6500) Harmonised code HO5 ZIZI-F. Acid gas emission to
BS EN 50267-2(IEC 60754-2), smoke emission to BS EN 50268 (IEC 61034) and
flame propagation to BS EN 50265 (IEC 60332-1).
CCC
CODE
3182B/75
3183B/75
3184B/75
3185B/75
3182B1
3183B1
3184B1
3185B1
3182B1/5
3183B1/5
3184B1/5
3185B1/5
3182B2/5
3183B2/5
3184B2/5
3185B2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5

24/0.2
24/0.2
24/0.2
24/0.2
32/0.2
32/0.2
32/0.2
32/0.2
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5

59
70
85
110
69
82
105
130
95
120
150
180
145
180
220
265

OVERALL
DIAMETER
(MM)
6.8
7.2
7.7
8.5
7.2
7.6
8.5
9.1
8.2
8.9
10
11
9.9
10.8
11.3
12.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20/16
20S
20S
20
20S
20S
20
20

Temperature limits:
-15 to +70c
*Bending radius:
Fixed 4x overall diameter
Flexing 6x overall diameter
Core identification:
2 core - Brown, Blue.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.
Should not be installed at
temperatures below 0C.

LOW SMOKE
ZERO HALOGEN FLEXIBLE
CORDS TYPE 318*B
(0.75MM2 TO 2.5MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

69

Plain annealed flexible copper conductors, PVC insulated, PVC sheathed.


Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
CODE
YY2X/75
YY3X/75
YY4X/75
YY5X/75
YY7X/75
YY12X/75
YY18X/75
YY25X/75
YY34X/75
YY50X/75
YY65X/75
YY2X1
YY3X1
YY4X1
YY5X1
YY7X1
YY12X1
YY18X1
YY25X1
YY34X1
YY41X1
YY50X1
YY65X1
YY2X1/5
YY3X1/5
YY4X1/5
YY5X1/5
YY7X1/5
YY8X1/5
YY10X1/5
YY12X1/5
YY18X1/5
YY25X1/5
YY34X1/5
YY50X1/5
YY65X1/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25

Temperature limits:
-5 to +70C.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED FLEXIBLE


POWER AND CONTROL
CABLE TYPE YY
(0.75MM2 TO 1.5MM2)

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
18
25
34
50
65
2
3
4
5
7
12
18
25
34
41
50
65
2
3
4
5
7
8
10
12
18
25
34
50
65

46
52
64
77
95
155
221
305
460
578
850
55
66
82
93
121
200
318
415
575
665
815
1055
69
87
110
124
176
230
265
290
424
565
775
1095
1390

OVERALL
DIAMETER
(MM)
5.6
5.7
6.2
7
7.3
9.5
11.1
13.2
16.7
18.4
23.5
6
6.1
6.7
7.5
8.1
11
12.7
15.5
18.3
19
21.3
25.6
6.6
7
7.6
8.1
9.2
11.2
12.4
13.1
14.8
18
21
24.2
28.8

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20
20
25
25
32
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
32
32
20/16
20/16
20/16
20S
20S
20
20
20
25
25
32
32
40

Also available with coloured cores


as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.
7 core - Blue, Brown, Black, Grey,
White, Red, Green/Yellow.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

TYPE YY CONTROL CABLES

FLEXIBLE CABLES

70

TYPE YY CONTROL CABLES


Plain annealed flexible copper conductors, PVC insulated, PVC sheathed.
Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
CODE
YY2X2/5
YY3X2/5
YY4X2/5
YY5X2/5
YY7X2/5
YY8X2/5
YY12X2/5
YY18X2/5
YY25X2/5
YY34X2/5
YY3X4
YY4X4
YY5X4
YY7X4
YY3X6
YY4X6
YY5X6
YY7X6
YY3X10
YY4X10
YY5X10
YY3X16
YY4X16
YY5X16
YY3X25
YY4X25
YY5X25
YY4X35
YY5X35
YY4X50

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
25.0
25.0
25.0
35.0
35.0
50.0

50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
396/0.40

Temperature limits:
-5 to +70C.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED FLEXIBLE


POWER AND CONTROL
CABLE TYPE YY
(2.5MM2 TO 50MM2)

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
8
12
18
25
34
3
4
5
7
3
4
5
7
3
4
5
3
4
5
3
4
5
4
5
4

106
126
159
178
272
350
403
597
885
1220
201
283
293
413
273
352
415
537
466
631
720
697
767
1151
930
1150
1679
1970
2206
2700

OVERALL
DIAMETER
(MM)
7.8
8.1
8.9
9.7
11.1
13.5
13.8
17.5
22
25.8
10.4
10.7
12.4
14
11.5
12.8
14.6
15.2
15.3
16.5
18.6
18.4
19.9
22.4
21.5
22.5
27.9
29
31.3
34

GLAND
SIZE
(MM)
20/16
20S
20S
20S
20S
20
20
25
32
32
20S
20S
20
25
20
20
25
25
25
25
25
25
32
32
32
32
40
40
40
50S

Also available with coloured cores


as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.
7 core - Blue, Brown, Black, Grey,
White, Red, Green/Yellow.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

71

Plain annealed flexible copper conductors, PVC insulated, extruded PVC


bedding, galvanised steel wire braid armour, transparent PVC outer sheath.
300/500 volts grade generally to BS6500 and VDE 0250 class 5.
CCC
CODE
SY2X/75
SY3X/75
SY4X/75
SY5X/75
SY7X/75
SY12X/75
SY18X/75
SY25X/75
SY34X/75
SY2X1
SY3X1
SY4X1
SY5X1
SY7X1
SY12X1
SY18X1
SY25X1
SY34X1
SY50X1
SY2X1/5
SY3X1/5
SY4X1/5
SY5X1/5
SY7X1/5
SY12X1/5
SY18X1/5
SY25X1/5
SY34X1/5
SY50X1/5
SY2X2/5
SY3X2/5
SY4X2/5
SY5X2/5
SY7X2/5
SY12X2/5
SY18X2/5
SY25X2/5
SY34X2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25

Temperature limits:
-5 to +70C.
*Bending radius:
Static - 10 x overall diameter.
Flexing - 20 x overall diameter.
Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

PVC INSULATED BRAIDED


FLEXIBLE CONTROL
CABLE TYPE SY
(0.75MM2 TO 2.5MM2)

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
12
18
25
34
2
3
4
5
7
12
18
25
34
50
2
3
4
5
7
12
18
25
34
50
2
3
4
5
7
12
18
25
34

78
91
104
121
135
214
293
418
610
85
95
120
123
171
276
382
437
556
955
100
143
170
173
198
341
490
606
835
1046
177
190
240
247
327
502
740
1065
1126

OVERALL
DIAMETER
(MM)
7.1
7.6
8.3
8.9
9.5
11.9
13.2
13.7
19
7.7
8.2
9
9.2
10.1
12.9
15
17.9
20
23.7
8.2
8.6
9.3
10
10.7
13.8
16.4
19.2
21.6
23.8
9.8
9.9
10.8
11.5
13
16.9
19.8
23.2
24.3

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20
20/16
20/16
20/16
20/16
20/16
20S
20
20
20
25
20/16
20/16
20/16
20/16
20/16
20S
20
20
25
25
20/16
20/16
20/16
20S
20S
20
20
25
25

Also available with coloured cores


as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

TYPE SY CONTROL CABLES

FLEXIBLE CABLES

72

TYPE SY CONTROL CABLES


Plain annealed flexible copper conductors, PVC insulated, extruded PVC
bedding, galvanised steel wire braid armour, transparent PVC outer sheath.
300/500 volts grade generally to BS6500 and VDE 0250 class 5.
CCC
CODE
SY3X4
SY4X4
SY5X4
SY7X4
SY3X6
SY4X6
SY5X6
SY7X6
SY3X10
SY4X10
SY5X10
SY3X16
SY4X16
SY5X16
SY4X25
SY5X25
SY4X35
SY5X35
SY4X50
SY4X70
SY4X95

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
25.0
25.0
35.0
35.0
50.0
70.0
95.0

56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
276/0.40
276/0.40
396/0.40
356/0.50
485/0.50

NO. OF
CORES

WEIGHT
KG/KM

3
4
5
7
3
4
5
7
3
4
5
3
4
5
4
5
4
5
4
4
4

323
354
392
486
343
458
572
640
563
776
855
813
900
1258
1597
2007
2046
2524
2888
4015
5176

OVERALL
DIAMETER
(MM)
12.2
13.4
15
16
13.4
14.6
16.7
18
17.3
19.1
21
20.5
22.4
25.2
28.2
31.2
31.3
34.3
37
41.2
47.8

GLAND
SIZE
(MM)
20S
20S
20
20
20S
20S
20
20
20
20
25
25
25
25
32
32
40
40
40
50S
50

Temperature limits:
-5 to +70C.
*Bending radius:
Static - 10 x overall diameter.
Flexing - 20 x overall diameter.
Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.
Also available with coloured cores
as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.

PVC INSULATED BRAIDED


FLEXIBLE CONTROL CABLE
TYPE SY
(4MM2 TO 95MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

73

Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned
copper wire braid screen, PVC outer sheath. Grey. 300/500 volts grade
generally to BS6500 and VDE 0250.
CCC
CODE
CY2X/5
CY3X/5
CY4X/5
CY5X/5
CY7X/5
CY2X/75
CY3X/75
CY4X/75
CY5X/75
CY7X/75
CY12X/75
CY18X/75
CY25X/75
CY2X1
CY3X1
CY4X1
CY5X1
CY7X1
CY12X1
CY18X1
CY25X1
CY34X1
CY2X1/5
CY3X1/5
CY4X1/5
CY5X1/5
CY7X1/5
CY12X1/5
CY18X1/5
CY25X1/5
CY34X1/5
CY42X1/5
CY2X2/5
CY3X2/5
CY4X2/5
CY5X2/5
CY7X2/5
CY12X2/5
CY2X4
CY3X4
CY4X4
CY5X4
CY4X6
CY4X10
CY4X16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
10.0
16.0

16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
80/0.40
126/0.40

Temperature limits:
Static - -20 to +80C.
Flexing - -5 to +70C.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.

PVC INSULATED BRAID


SCREENED FLEXIBLE
POWER AND CONTROL
CABLE TYPE CY
(0.75MM2 TO 16MM2)

Core identification:
2 core - Black with White numbers.
3 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -5C.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
2
3
4
5
7
12
18
25
2
3
4
5
7
12
18
25
34
2
3
4
5
7
12
18
25
34
42
2
3
4
5
7
12
2
3
4
5
4
4
4

41
50
66
79
102
43
52
68
80
103
161
238
316
53
64
84
100
125
209
308
420
650
61
78
104
128
159
281
396
534
720
1015
102
117
168
199
252
500
165
186
239
301
327
553
846

OVERALL
DIAMETER
(MM)
5.0
5.2
6.2
7.0
7.2
5.5
5.8
6.5
7.1
7.6
9.9
11.7
13.9
6.3
6.4
7.2
7.8
8.5
11.3
13.3
16.23
19.5
6.5
6.9
7.7
8.6
9.2
12.7
14.7
17.49
19.89
23.8
8
8.4
9.19
10.3
11.2
16.8
10.5
10.3
11.8
13
12.9
17.2
21

GLAND
SIZE (MM)
BRASS A2
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20
20
20/16
20/16
20/16
20/16
20/16
20S
20
25
25
20/16
20/16
20/16
20S
20
25
25
25
32
25
20/16
20/16
20S
20S
20S
25
20S
20S
20S
20S
20S
25
32

Also available with coloured cores


as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow o(ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

TYPE CY CONTROL CABLES

FLEXIBLE CABLES

74

TYPE YY CONTROL CABLES LSZH


Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH)
insulated, low smoke and zero halogen (LSZH) sheathed. Grey. 300/500 volts
grade, generally to BS6500 and VDE 0250.
CCC
CODE
YY2X/75LSF
YY3X/75LSF
YY4X/75LSF
YY5X/75LSF
YY2X1LSF
YY3X1LSF
YY4X1LSF
YY5X1LSF
YY2X1/5LSF
YY3X1/5LSF
YY4X1/5LSF
YY5X1/5LSF
YY7X1/5LSF
YY12X1/5LSF
YY18X1/5LSF
YY25X1/5LSF
YY34X1/5LSF
YY2X2/5LSF
YY3X2/5LSF
YY4X2/5LSF
YY5X2/5LSF
YY3X4LSF
YY4X4LSF
YY5X4LSF
YY3X6LSF
YY4X6LSF
YY5X6LSF
YY3X10LSF
YY4X10LSF
YY5X10LSF
YY3X16LSF
YY4X16LSF
YY3X25LSF

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
25.0

24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.3
56/0.3
84/0.30
84/0.3
84/0.30
80/0.40
80/0.4
80/0.40
126/0.4
126/0.4
196/0.40

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
2
3
4
5
2
3
4
5
7
12
18
25
34
2
3
4
5
3
4
5
3
4
5
3
4
5
3
4
3

46
52
64
77
55
66
82
93
69
87
110
124
176
290
424
565
775
106
126
159
178
201
283
293
273
352
415
466
631
720
697
767
930

Temperature limits:
-5 to +70C
*Bending radius:

OVERALL
DIAMETER
(MM)
5.6
5.7
6.2
7
6
6.1
6.7
7.5
6.6
7
7.6
8.1
9.2
13.1
14.8
18
21
7.8
8.1
8.9
9.7
10.4
10.7
12.4
11.5
12.8
14.6
15.3
16.5
18.6
18.4
19.9
21.5

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
32
20/16
20S
20S
20S
20S
20S
20
20
20
25
25
25
25
25
32
32

Core identification:
2 Core - Black with white numbers
3 Core and above
Black with white numbers plus
Green/Yellow
Should not be installed at
temperatures below -5C.

Static - 6 x Overall Diameter


Flexible - 15 x Overall Diameter

TYPE CY CONTROL CABLES LSZH


Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH)
insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen (LSZH)
outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
CODE
CY2X/75LSF
CY3X/75LSF
CY4X/75LSF
CY5X/75LSF
CY2X1/5LSF
CY3X1/5LSF
CY4X1/5LSF
CY5X1/5LSF

LSZH SHEATHED
POWER AND CONTROL
CABLE TYPE YY
(0.75MM2 TO 25MM2)
AND TYPE CY
(0.75MM2 TO 1.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5

24/0.20
24/0.20
24/0.20
24/0.20
30/0.25
30/0.25
30/0.25
30/0.25

Temperature limits:
-5 to 70C
*Bending radius:
Static - 6 x Overall Diameter
Flexible - 15 x Overall Diameter
Core identification:
2 Core - Black with White numbers
3 Core and above
Black with White numbers plus
Green/Yellow
Should not be installed at
temperatures below -5C.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
2
3
4
5

43
52
68
80
61
78
104
128

OVERALL
DIAMETER
(MM)
5.5
5.8
6.5
7.1
6.5
6.9
7.7
8.6

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16

Also available with coloured cores


as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow (ccc standard stock) as
per Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

75

Plain annealed stranded circular copper conductors, circular high temperature


PVC outer sheath. UL & CSA approved also to BS6231. 600/1000 volts grade.
Flame propagation to BS EN 50265 and IEC 60332-1.
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

TRI0/5
TRI/75
TRI1
TRI1/5
TRI2/5
TRI4
TRI6
TRI10
TRI16
TRI25
TRI35
TRI50
TRI70
TRI95
TRI120
BI150
BI185
BI240
BI300
BI400

0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150
185
240
300
400

16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50

12
15
18
23
34
50
71
123
207
303
412
607
837
1079
1280
1619
1948
2518
3112
4051

OVERALL
DIAMETER
(MM)
2.7
2.9
3.1
3.3
3.7
4.3
4.9
6.3
9.0
10.4
11.9
14.7
16.8
18.8
19.9
22.9
24.1
28.6
32.2
36

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
32
32
32
40
50S
50

Temperature limits:
-30 to +105C.
Should not be installed at
temperatures below 0C.
Standard colours available:
0.5mm2 - 2.5mm2 - Brown, Black,
Grey, Blue, Green/Yellow, Red, Yellow,
White, Orange, Pink, Violet.
4.0mm2 - 16mm2 - Brown, Black, Grey,
Blue, Green/Yellow, Red, Yellow, White.
25.0mm2 - 120mm2 - Brown, Black,
Grey, Blue, Green/Yellow, Red, Yellow.
150mm2 - Black, Green/Yellow.
185mm2 - 400mm2 - Black.

TRI-RATED SWITCHGEAR
AND CONTROL
PANEL WIRE
(0.5MM2 TO 400MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

FLEXIBLE CABLES

TRI-RATED EQUIPMENT WIRES

FLEXIBLE CABLES

76

2491B/6701B LSZH FLEXIBLE SINGLE CORES


Flexible plain annealed copper conductor, low smoke zero halogen (LSZH) outer
sheath to BS7211. 0.75mm/1.0mm rated at 300/500 volts grade, harmonised
code HO5Z-K. 1.5mm to 240mm rated at 450/750 volts grade, harmonised
code HO7Z-K. Fire resistant to BS EN 50266-1:2001 (formerly BS4066:PT1).
CCC
CODE
2491B/75
2491B1
2491B1/5
2491B2/5
2491B4
2491B6
6701B10
6701B16
6701B25
6701B35
6701B50
6701B70
6701B95
6701B120
6701B150
6701B185
6701B240

LOW SMOKE
ZERO HALOGEN
SHEATHED
FLEXIBLE CABLE
(1.5MM2 TO 240MM2)
PVC INSULATED
PVC SHEATHED
FLEXIBLE CABLE
(6MM2 TO 400MM2)

CONDUCTOR
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0

STRANDING
SIZE (MM)
24/0.20
32/0.20
30/0.25
50/0.25
56/0.25
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50

NO. OF
CORES
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Temperature limits:
- 15 to + 90C
*Bending radius:
up to 35mm2 - 3 x Overall Diameter
50mm2 and above - 4 x Overall
Diameter

WEIGHT
(KG/KM)
12
14
20
30
45
65
110
160
250
340
480
670
890
1140
1410
1710
2270

OVERALL
DIAMETER
2.12
2.48
2.98
3.63
4.23
4.83
6.10
7.10
8.70
9.90
11.60
13.30
15.20
17.00
18.90
21.00
23.90

Standard colours available:


1.5mm to 6mm - Black, Blue, Brown,
Grey,
Orange, White, Red, Yellow,
Green/Yellow.
10mm2 - 240mm2 - Black, Blue,
Brown, Grey.

SINGLE CORE PVC FLEXIBLE MAINS CABLES


Plain annealed flexible copper conductor, PVC insulated PVC sheathed,
450/750 volts, generally to BS6004 & IEC60502. Flame propogation to
BS4066 PT1 & IEC332 PT1.
CCC
CODE
6381Y6
6381Y10
6381Y16
6381Y25
6381Y35
6381Y50
6381Y70
6381Y95
6381Y120
6381Y150
6381Y185
6381Y240
6381Y300
6381Y400

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
6.0
10.00
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0

84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50

Temperature limits:
-15 to +70C.
*Bending radius:
Up to 50mm 3 x overall diameter.
Over 70mm 5 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

1
1
1
1
1
1
1
1
1
1
1
1
1
1

105
151
208
303
401
560
748
990
1233
1528
1857
2419
3032
3937

OVERALL
DIAMETER
(MM)
7.7
8.8
9.9
11.4
12.7
14.6
16.1
18.6
20.2
22.5
25.1
28.3
31.2
35.4

GLAND
SIZE
(MM)
20/16
20S
20S
20
20
25
25
25
32
32
32
40
40
50S

Standard core colours available:


Black, grey, blue, brown, green/yellow.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

77

Electroltic annealed tinned flexible copper conductor, halogen free


thermosetting rubber insulation, type EI6 according to EN 50363-1 and
table 4 of the TUV standard, halogen free thermosetting rubber outer
sheath, type EM8 according to EN 50363-1 and table 4 of the TUV
standard. Black.
CCC
CONDUCTOR
CODE
SOLAR1X1/5BK
1.5
SOLAR1X2/5BK
2.5
SOLAR1X4BK
4.0
SOLAR1X6BK
6.0
SOLAR1X10BK
10
SOLAR1X16BK
16
SOLAR1X25BK
25
SOLAR1X35BK
35

STRANDING
SIZE (MM)
29/0.25
48/0.25
48/0.3
72/0.3
126/0.3
116/0.4
180/0.4
260/0.4

NO. OF
CORES
1
1
1
1
1
1
1
1

WEIGHT
(KG/KM)
40
49
66
86
132
188
294
390

OVERALL
DIAMETER
4.90
5.35
6.00
6.55
7.60
8.60
10.80
11.90

Characteristics.
Nominal voltage: AC: 0,6/1 kV; DC: 1,8 kV
Ambient temperature range: -40 C to + 90 C.
Maximum conductor temperature: 120 C.
Maximum short-circuit temperature: 250 C (maximum 5 s).
*Minimum bending radius (fixed): 5 x cable .
No flame propagation: EN 60332-1-2 / IEC 60332-1-2.
No fire propagation: EN 60332-3 / IEC 60332-3.
Halogen free: according to EN 50267 / IEC 60754
HCl content < 0,5%.
pH > 4,3;
conductivity < 10 !S/mm.
Smoke density: light transmittance > 60% (according to EN 61034 / IEC
61034).

SOLAR ENERGY
CABLES

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

SOLAR ENERGY CABLES

FLEXIBLE CABLES

78

FLEXIBLE MAINS AND CONTROL CABLES EPR,CSP


Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR)
insulated, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts
grade to BS6500. Black or White. Heat and oil resistant and flame
retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1).
Harmonised code H07BN4-F.
CCC
CODE
3182TQ/75
3183TQ/75
3184TQ/75
3182TQ1
3183TQ1
3184TQ1
3181TQ1/5
3182TQ1/5
3183TQ1/5
3184TQ1/5
3185TQ1/5
3186TQ1/5
3187TQ1/5
3180/12TQ1/5
3180/16TQ1/5
3180/20TQ1/5
3180/27TQ1/5
3180/37TQ1/5
3181TQ2/5
3182TQ2/5
3183TQ2/5
3184TQ2/5
3185TQ2/5
3187TQ2/5
3180/12TQ2/5
3180/16TQ2/5
3180/20TQ2/5
3180/27TQ2/5
3180/37TQ2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
1
2
3
4
5
6
7
12
16
20
27
37
1
2
3
4
5
7
12
16
20
27
37

58
72
86
80
90
110
38
115
135
170
200
335
366
410
570
710
920
1260
41
160
195
245
300
424
600
780
1050
1390
1720

MEAN OVERALL DIAMETER


(MM)
LOWER LIMIT UPPER LIMIT
5.7
7.4
6.2
8.1
6.8
8.8
6.1
8.0
6.5
8.5
7.1
9.3
5.7
7.1
7.6
9.8
8.0
10.4
9.0
11.6
11.2
14.4
13.4
17.2
14.6
18.2
17.6
22.4
19.8
24.3
21.4
26.7
25.3
30.0
29.0
34.2
6.3
7.9
9.0
11.6
9.6
12.4
10.7
13.8
13.3
17.0
17.2
21.0
20.6
26.2
23.8
28.4
26.4
31.2
30.1
35.4
35.0
40.9

Temperature limits:
-25 to +90C.
*Bending radius:
Fixed - 6 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -25C.

EPR INSULATED HOFR


SHEATHED FLEXIBLE
POWER AND
CONTROL CABLE
(0.75MM2 TO 2.5MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

79

Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR)


insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750
volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR).
Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised
code H07BN4-F.
CCC
CODE
6381TQ4
6382TQ4
6383TQ4
6384TQ4
6385TQ4
6387TQ4
6380/12TQ4
6381TQ6
6382TQ6
6383TQ6
6384TQ6
6385TQ6
6387TQ6
6388TQ6
6381TQ10
6382TQ10
6383TQ10
6384TQ10
6385TQ10
6381TQ16
6382TQ16
6383TQ16
6384TQ16
6385TQ16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6
6
6
6
6
6
6
10
10
10
10
10
16
16
16
16
16

56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
126/0.40
126/0.40

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
5
7
12
1
2
3
4
5
7
8
1
2
3
4
5
1
2
3
4
5

105
275
335
420
515
773
1183
130
370
450
565
690
904
1040
200
690
835
1020
1240
275
910
1120
1380
1695

MEAN OVERALL DIAMETER


(MM)
LOWER LIMIT UPPER LIMIT
7.2
9.0
11.8
15.1
12.7
16.2
14.0
17.9
15.6
19.9
19.8
24.4
24.4
30.9
7.9
9.8
13.1
16.8
14.1
18.0
15.7
20.0
17.5
22.9
21.6
26.9
25.2
29.6
9.5
11.9
17.7
22.6
19.1
24.2
20.9
26.5
22.9
29.1
10.8
13.4
20.2
25.7
21.8
27.6
23.8
30.1
26.4
33.3

Temperature limits:
-25 to +90C.
*Bending radius:
Fixed - 6 x overall diameter.
Flexing - 7 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -25C.

EPR INSULATED
HEAVY DUTY
HOFR SHEATHED FLEXIBLE
MAINS CABLE
(4MM2 TO 16MM2 )

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

FLEXIBLE MAINS CABLES EPR,CSP

FLEXIBLE CABLES

80

FLEXIBLE MAINS CABLES EPR,CSP


Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR)
insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750
volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR).
Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised code
H07BN4-F.
CCC
CODE
6381TQ25
6382TQ25
6383TQ25
6384TQ25
6385TQ25
6381TQ35
6382TQ35
6383TQ35
6384TQ35
6385TQ35
6381TQ50
6383TQ50
6384TQ50
6385TQ50
6381TQ70
6383TQ70
6384TQ70
6385TQ70
6381TQ95
6383TQ95
6384TQ95
6385TQ95
6381TQ120
6383TQ120
6384TQ120
6385TQ120
6381TQ150
6383TQ150
6384TQ150
6381TQ185
6383TQ185
6384TQ185
6381TQ240
6383TQ240
6384TQ240
6381TQ300
6383TQ300
6384TQ300
6381TQ400
6381TQ500
6381TQ630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
25
25
25
25
25
35
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
500
630

196/0.40
196/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
276/0.40
276/0.40
276/0.40
396/0.40
396/0.40
396/0.40
396/0.40
360/0.50
360/0.50
360/0.50
360/0.50
475/0.50
475/0.50
475/0.50
475/0.50
608/0.50
608/0.50
608/0.50
608/0.50
756/0.50
756/0.50
756/0.50
925/0.50
925/0.50
925/0.50
1221/0.50
1221/0.50
1221/0.50
1525/0.50
1525/0.50
1525/0.50
2013/0.50
1769/0.60
2257/0.60

Temperature limits:
-25 to +90C.
*Bending radius:
Fixed - 5 x overall diameter.
Flexing - 7 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.

EPR INSULATED
HOFR SHEATHED
POWER AND
CONTROL CABLE
(25MM2 TO 630MM2)

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
5
1
2
3
4
5
1
3
4
5
1
3
4
5
1
3
4
5
1
3
4
5
1
3
4
1
3
4
1
3
4
1
3
4
1
1
1

400
1290
1600
2140
2470
520
1308
2080
2610
3187
730
2890
3650
4450
980
3850
4880
5938
1270
4970
6390
7924
1570
6350
7750
7542
1960
7700
9780
2380
9350
11900
3100
12000
15330
3790
14910
19030
4880
6070
7460

MEAN OVERALL DIAMETER


(MM)
LOWER LIMIT UPPER LIMIT
12.7
15.8
24.3
30.7
26.1
33.0
28.9
36.6
32.0
40.4
14.3
17.9
26.4
31.5
29.3
37.1
32.5
41.1
34.0
43.0
16.5
20.6
34.1
42.9
37.7
47.5
39.03
49.18
18.6
23.3
38.4
48.3
42.7
54.0
48.5
55.0
20.8
26.0
43.3
54.0
48.4
61.0
54.0
64.5
22.8
28.6
47.4
60.0
53.0
66.0
57.9
58.5
25.2
31.4
52.0
66.0
58.0
73.0
27.6
34.4
57.0
72.0
64.0
80.0
30.6
38.3
65.0
82.0
72.0
91.0
33.5
41.9
72.0
90.0
80.0
101.0
37.4
46.8
41.3
52.0
45.5
56.5

4 core - Grey, Black, Brown,


Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below -25C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

81

Plain annealed flexible copper conductors, rubber insulated, heavy duty


polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized
code type HO7RN-F. Flame propagation to EN 60332-1-2.
CCC
CODE
3182P1
3183P1
3184P1
3182P1/5
3183P1/5
3184P1/5
3185P1/5
3187P1/5
3180/12P1/5
3182P2/5
3183P2/5
3184P2/5
3185P2/5
3187P2/5
3180/12P2/5
3182P4
3183P4
3184P4
3185P4
6382P6
6383P6
6384P6
6385P6
6381P10
6382P10
6383P10
6384P10
6385P10
6381P16
6382P16
6383P16
6384P16
6385P16
6381P25
6382P25
6383P25
6384P25
6385P25
6381P35
6383P35
6384P35
6385P35
6381P50
6383P50
6384P50
6385P50

CONDUCTOR STRANDING
(MM)
SIZE (MM2)
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10
10
10
10
10
16
16
16
16
16
25
25
25
25
25
35
35
35
35
50
50
50
50

32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
276/0.40
276/0.40
396/0.40
396/0.40
396/0.40
396/0.40

Temperature limits:
-25 to +60C.
Can be supplied suitable for up to
85C upon special request.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
5
7
12
2
3
4
5
7
12
2
3
4
5
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
3
4
5
1
3
4
5

95
115
140
132
165
200
240
385
520
193
235
290
345
520
810
275
320
395
485
350
495
610
760
230
640
880
1060
1300
320
850
1090
1345
1680
450
1210
1394
1995
2470
605
1850
2645
2930
825
2890
3635
4450

MEAN OVERALL DIAMETER


(MM)
LOWER LIMIT UPPER LIMIT
6.1
8.0
6.5
8.5
7.1
9.3
7.6
9.8
8.0
10.4
9.0
11.6
11.2
14.4
14.6
18.2
17.6
22.4
9.0
11.6
9.6
12.4
10.7
13.8
13.3
17.0
17.2
21.0
20.6
26.2
11.8
15.1
12.7
16.2
14.0
17.9
15.6
19.9
13.1
16.8
14.1
18.0
15.7
20.0
17.5
22.9
9.5
11.9
17.7
22.6
19.1
24.2
20.9
26.5
22.9
29.1
10.8
13.4
20.2
25.7
21.8
27.6
23.8
30.1
26.4
33.3
12.7
15.8
24.3
30.7
26.1
33.0
28.9
36.6
32.0
40.4
14.3
17.9
29.3
37.1
32.5
41.1
34.0
43.0
16.5
20.6
34.1
42.9
37.7
47.5
39.03
49.18

5 core - Grey, Black, Brown, Blue,


Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below 0C.

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.

RUBBER INSULATED
NEOPRENE SHEATHED
FLEXIBLE
POWER CABLE
(1MM2 TO 50MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F

FLEXIBLE CABLES

82

FLEXIBLE MAINS AND CONTROL CABLES HO7RN-F


Plain annealed flexible copper conductors, rubber insulated, heavy duty
polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonized
code type HO7RN-F. Flame propagation to EN 60332-1-2.
CCC
CODE
6381P70
6383P70
6384P70
6385P70
6381P95
6383P95
6384P95
6385P95
6381P120
6383P120
6384P120
6381P150
6383P150
6384P150
6381P185
6383P185
6384P185
6381P240
6381P300
6381P400
6383P240
6384P240
6381P500
6381P630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
300
400
240
240
500
630

360/0.50
360/0.50
360/0.50
360/0.50
475/0.50
475/0.50
475/0.50
475/0.50
608/0.50
608/0.50
608/0.50
756/0.50
756/0.50
756/0.50
925/0.50
925/0.50
925/0.50
1221/0.50
1525/0.50
2257/0.50
1221/0.50
1221/0.50
1769/0.60
2257/0.60

Temperature limits:
-25 to +60C.
Can be supplied suitable for up to
85C upon special request.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.

RUBBER INSULATED
NEOPRENE SHEATHED
FLEXIBLE
POWER CABLE
(70MM2 TO 630MM2)

NO. OF
CORES

WEIGHT
KG/KM

1
3
4
5
1
3
4
5
1
3
4
1
3
4
1
3
4
1
1
1
3
4
1
1

1090
3850
4830
5938
1405
4185
6320
6695
1745
5051
6453
1824
6267
8031
2202
7661
9830
2847
3495
4880
9692
12444
5301
7460

MEAN OVERALL DIAMETER


(MM)
LOWER LIMIT UPPER LIMIT
18.6
23.3
38.4
48.3
42.7
54.0
48.5
55.0
20.8
26.0
43.3
50
48.5
61.0
54.0
64.5
22.8
28.6
47.4
60.0
53.0
66.0
25.2
31.4
52.0
66.0
58.0
73.0
27.6
34.4
57.0
72.0
64.0
80.0
30.6
38.3
33.5
41.9
45.5
56.5
65.0
82.0
72.0
91.0
41.3
52.0
45.5
56.5

4 core - Grey, Black, Brown,


Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

83

Flexible tinned annealed copper conductors, ethylene propylene rubber insulated,


tough rubber sheath. Black. 300/500 volts grade to BS6500 and BS7919.
CCC
CODE
3182/75
3183/75
3184/75
31821
31831
31841
31821/5
31831/5
31841/5
31851/5
31822/5
31832/5
31842/5
31852/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5

24/0.20
24/0.20
24/0.20
30/0.20
30/0.20
30/0.20
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
2
3
4
5
2
3
4
5

63
78
94
77
90
110
115
135
170
195
165
195
245
290

Temperature limits:
+60C.
*Bending radius:

EPR INSULATED BRAIDED


SCREEN FLEXIBLE MAINS
AND CONTROL CABLE
(1.0MM2 TO 16MM2)

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20S
20S
20S
20
20

3 core - Blue, Brown, Green/Yellow.


4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown, Blue,
Green/Yellow.

6 x overall diameter.

EPR INSULATED TOUGH


RUBBER SHEATH
(0.75MM2 TO 2.5MM2)

OVERALL
DIAMETER
(MM)
6.6
7.2
7.8
7.1
7.5
8.2
8.7
9.2
9.8
10.3
10.3
11.0
11.9
12.3

Core identification:
2 core - Blue, Brown.

BRAIDED TOUGH RUBBER SHEATH FLEXIBLE CORDS


Flexible tinned annealed copper conductors, ethylene propylene rubber
insulated, chlorosulphonated polyethylene bedding (CSP), tinned copper wire
braid screen, chlorosulphonated polyethylene (CSP) outer sheath. 300/500
volts grade to BS6500/75 and 450/750 Volts grade to BS6007/75 (where
applicable). Black. Flame propogation to BS 4066 PT1 and IEC 332 PT1.
Heat and oil resistant and flame retardant (HOFR).
CCC
CODE
3802TQ1
3803TQ1
3804TQ1
3802TQ1/5
3803TQ1/5
3804TQ1/5
3802TQ2/5
3803TQ2/5
3804TQ2/5
3803TQ4
3804TQ4
6803TQ6
6804TQ6
6803TQ10
6804TQ10
6803TQ16
6804TQ16

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
6.0
6.0
10.0
10.0
16.0
16.0

32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
84/0.30
84/0.30
90/0.40
90/0.40
126/0.40
126/0.40

Temperature limits:
-25 to +90C.
*Bending radius:
8 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
2
3
4
3
4
3
4
3
4
3
4

170
200
230
225
270
320
300
350
420
715
865
973
1166
1592
1878
1992
2452

OVERALL
DIAMETER
(MM)
11.1
11.4
12.1
12.3
13.1
14.2
14.8
15.6
17.0
21.3
23.6
24.8
27.1
30.7
33.3
33.8
37.2

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20S
20S
20S
20
20
25
25
25
32
32
40
40
40

4 core - Grey, Black, Brown, Blue,


Green/Yellow.
Should not be installed at
temperatures below 0C.

Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

TOUGH RUBBER SHEATH FLEXIBLE CORDS

FLEXIBLE CABLES

84

COIL END LEAD FLEXIBLE MAINS CABLES


Flexible tinned annealed copper conductors composite ethylene propylene rubber
chlorosulphonated polyethylene (EPR-CSP) insulation to BS6195/69 Type 4.
A. 300/500 volts grade
C. 600/1000 volts grade
D. 1900/3300 volts grade

E. 3800/6600 volts grade


F. 6350/11000 volts grade

CONDUCTOR

CCC CODE

SIZE
(MM2)

STRANDING
(MM2)

TYPE 4 1/5
TYPE 4 2/5
TYPE 4 4
TYPE 4 6
TYPE 4 10
TYPE 4 16
TYPE 4 25
TYPE 4 35
TYPE 4 50
TYPE 4 70
TYPE 4 95
TYPE 4 120
TYPE 4 150
TYPE 4 185
TYPE 4 240
TYPE 4 300
TYPE 4 400
TYPE 4 500

0.5
0.75
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
3679/0.40

CCC CODE

TYPE 4 1/5
TYPE 4 2/5
TYPE 4 4
TYPE 4 6
TYPE 4 10
TYPE 4 16
TYPE 4 25
TYPE 4 35
TYPE 4 50
TYPE 4 70
TYPE 4 95
TYPE 4 120
TYPE 4 150
TYPE 4 185
TYPE 4 240
TYPE 4 300
TYPE 4 400
TYPE 4 500

EPR INSULATED FLEXIBLE


COIL LEAD
(0.5MM2 TO 400MM2)

RADIAL THICKNESS OF INSULATION


VOLTAGE CATEGORY
MAX APPROX.
A
C
D
E
F
DIA. OF DIA. OF (MM) (MM) (MM) (MM) (MM)
WIRES COND.
(MM) (MM)
0.21
0.93
0.8
1.4
0.21
1.14
0.8
1.4
0.21
1.32
0.8
1.4
0.26
1.60
0.8
1.4
0.26
2.00
0.9
1.4
2.8
0.31
2.6
1.0
1.4
0.31
3.6
1.0
1.5
0.41
4.6
1.2
1.5
0.41
5.7
1.5
2.8
5.0
7.6
0.41
7.1
1.6
2.8
5.0
7.6
0.41
8.5
1.6
2.8
5.0
7.6
0.41
10.3
1.7
2.8
5.0
7.6
0.51
12.4
1.8
2.8
5.0
7.6
0.51
14.5
2.0
3.0
5.0
7.6
0.51
16.0
2.2
3.0
5.0
7.6
0.51
18.0
2.3
3.0
5.0
7.6
0.51
20.0
2.4
3.0
5.0
7.6
0.51
23.0
2.4
3.0
5.0
7.6
0.51
26.0
2.6
3.0
0.51
30.0
2.8
3.0
0.61
29.0
3.0
-

MINIMUM OVERALL DIAMETER


WEIGHT
VOLTAGE CATEGORY
VOLTAGE CATEGORY
A
C
D
E
F
A
C
D
E
(MM) (MM) (MM) (MM) (MM) KG/KM KG/KM KG/KM KG/KM
3.3
4.5
12
17
3.5
4.7
16
21
3.7
4.9
19
24
4.0
5.2
25
30
4.6
5.6
8.5
37
41
76
5.4
6.3
57
66
6.5
7.5
80
93
7.9
8.5
130
136
9.6
12.4
17.2
22.9
206
255
384
11.4
13.8
18.6
24.1
300
351
495
12.8
15.2
20.0
25.5
406
458
613
14.8
17.1
21.1
27.3
573
616
796
17.2
19.2
24.2
29.4
793
820
1020
19.7
22.0
26.3
31.5
1028 1097 1287
21.9
23.5
27.8
33.3
1285 1340 1542
24.1
25.5
29.8
35.3
1562 1635 1853
26.3
27.5
32.1
37.3
1914 1973 2225
29.3
30.5
35.1
40.3
2431 2504 2782
33.0
33.8
3024 3098
37.4
37.8
3948 4045
34.8
4920
-

Temperature limits:
-20 to +90C.
*Bending radius:

F
KG/KM
566
680
810
997
1237
1520
1804
2131
2503
3081
-

Should not be installed at


temperatures below -25C.

6 x overall diameter.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

85

Tinned annealed flexible circular copper conductors, ethylene propylene


rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath.
Orange. Ref 0361TQ. To BS638 Part 4. Flame retardant to BS EN 60332-1-2
(BS EN 50265-2-1).
CCC
CODE

CONDUCTOR
SIZE (MM2)

STRANDING
(MM)

WEIGHT
KG/KM

0361TQ16OR
0361TQ25OR
0361TQ35OR
0361TQ50OR
0361TQ70OR
0361TQ95OR
0361TQ120OR
0361TQ185OR

16
25
35
50
70
95
120
185

513/0.20
783/0.20
1107/0.20
1566/0.20
2214/0.20
2997/0.20
608/0.50
925/0.50

235
330
440
610
840
1120
1410
2100

OUTSIDE
DIAMETER
(MM)
11.5
13.0
14.5
17.0
19.5
22.0
24.0
29.0

GLAND
SIZE
(MM)
20S
20
25
25
32
32
32
40

Temperature limits:
-20 to +85C.
*Bending radius:
8 x overall diameter.

EPR INSULATED FLEXIBLE


WELDING CABLE
TYPE 0361TQ
(16MM2 TO 185MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

WELDING CABLES 0361TQ

FLEXIBLE CABLES

86

RUBBER FLATFORM CABLES


Flexible plain copper conductors, thermoplastic rubber insulated (TPR)
thermoplastic outer sheath (TPR). Black. 600/1000 volts grade.
CCC
CODE
FLAT4X1/5R
FLAT12X1/5R
FLAT4X2/5R
FLAT7X2/5R
FLAT12X2/5R
FLAT4X4R
FLAT4X6R
FLAT4X10R
FLAT4X16R
FLAT4X25R
FLAT4X35R
FLAT4X50R
FLAT4X70R

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5
2.5
4
6
10
16
25
35
50
70

30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50

NO. OF
CORES

WEIGHT
KG/KM

4
12
4
7
12
4
4
4
4
4
4
4
4

110
320
170
300
490
250
330
550
800
1350
1800
2400
3250

OVERALL MAX CURRENT


DIMENSIONS RATINGS
(MM)
(AMPS)
16X5
22
29X5
12
19X6
30
33X7
20
51X6
20
21X7
40
24X7
52
29X9
70
35X10
95
46X14
127
51X15
157
56X17
190
63X18
242

Temperature limits:
-35 to +85C.
*Bending radius:

7 and 12 core - Black cores with


White numbers and one
Green/Yellow.

10 x overall diameter.

Should not be installed at


temperatures below 0C.

Core identification:
4 core - Black, Grey, Brown,
Green/Yellow.

PVC FLATFORM CABLES


Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black.
450/750 volts grade type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6.
CCC
CODE
FLAT4X1/5V
FLAT12X1/5V
FLAT4X2/5V
FLAT12X2/5V
FLAT4X4V
FLAT4X6V
FLAT4X10V
FLAT4X16V
FLAT4X25V
FLAT4X35V
FLAT4X50V
FLAT4X70V
FLAT4X95V

RUBBER INSULATED
FLAT CABLE
(1.5MM2 TO 70MM2)
AND PVC INSULATED
FLAT CABLE
(1.5MM2 TO 95MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5
4
6
10
16
25
35
50
70
95

30/0.25
30/0.25
50/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50

Temperature limits:
-25 to +70C.
*Bending radius:
10 x overall diameter.

NO. OF
CORES

WEIGHT
KG/KM

4
12
4
12
4
4
4
4
4
4
4
4
4

150
420
210
620
300
385
620
990
1550
2030
2650
3650
4550

OVERALL MAX CURRENT


DIMENSIONS RATINGS
(MM)
(AMPS)
15X5
20
41X5
11
19X6
27
51X6
16
21X7
36
23X7
48
29X9
63
37X11
85
46X14
112
51X15
138
56X17
168
63X18
213
73X21
258

12 core - Black cores with white


numbers and one Green/Yellow.
Should not be installed at
temperatures below 0C.

Core identification:
4 core - Black, Grey, Brown,
Green/Yellow.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

87

Flexible tinned annealed copper conductors, silicone insulated, silicone outer


sheath. 300/500 volts grade to VDE 0250 PT816.
CCC
CODE
BIHF2X/75
BIHF3X/75
BIHF4X/75
BIHF5X/75
BIHF7X/75
BIHF2X1
BIHF3X1
BIHF4X1
BIHF5X1
BIHF7X1
BIHF2X1/5
BIHF3X1/5
BIHF4X1/5
BIHF5X1/5
BIHF7X1/5
BIHF2X2/5
BIHF3X2/5
BIHF4X2/5
BIHF5X2/5
BIHF7X2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
7
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7

53.4
63.7
83.6
101.2
124.9
59.9
78.3
94.6
116.1
144.3
82.0
98.0
122.0
148.0
187.0
135.0
152.0
188.0
230.0
293.0

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25

OVERALL
DIAMETER
(MM)
6.5
6.9
7.9
8.6
9.3
6.7
7.5
8.1
8.9
9.6
7.6
8.0
8.8
9.6
10.4
8.9
9.1
10.1
10.9
13.1

GLAND
SIZE
(MM)
20/16
20/16
20/16
20S
20S
20/16
20/16
20S
20S
20S
20/16
20/16
20S
20S
20S
20S
20S
20S
20S
20

Temperature limits:
-60 to +180C.
*Bending radius:
Fixed - 5 x overall diameter.
Flexing - 15 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core and above - Grey, Black, Brown,
Blue, Green/Yellow
6 core and above - Black with White
numbers plus Green/Yellow.
Should not be installed at
temperatures below 0C.

SILICONE INSULATED
FLEXIBLE CABLE
(0.75MM2 TO 2.5MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

FLEXIBLE CABLES

SILICON FLEXIBLE CABLES SIHF

89

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION,
CONTROL AND
COMMUNICATION
CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

90

INSTRUMENTATION AND CONTROL CABLES - PAS5308


PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, collective aluminium/mylar tape screen complete with 0.5mm2
drain wire, PVC outer sheath reduced propagation, Blue or Black. Flame
propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
PAS5308 PART 2, TYPE 1 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC
outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066
PT1, BS EN 50265 and IEC 60332-1.
CCC CODE
PT1

PT2

7100
7101
7102
7103
7104
7105
7106
7107
7136
7137
7138
7139
7140
7141
7142
7143
7173
7174
7175
7176
7177
N/A
N/A
7178

7300
7301
7302
7303
7304
7305
7306
7307
7336
7337
7338
7339
7340
7341
7342
7343
7373
7374
7375
7376
7377
N/A
N/A
7378

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
50
1 TRIPLE

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
60
6.00
75
6.90
190
12.10
305
16.20
518
21.30
759
25.90
1251
32.90
69
6.10
69
6.30
99
7.30
242
13.30
380
17.70
684
23.50
989
28.50
1670
36.40
83
6.80
87
7.30
145
8.70
345
15.40
575
20.60
1075
27.50
1720
33.7
2750
43.6
115
8.40

BRASS
A2
GLAND
20/16
20/16
20
25
32
32
50S
20/16
20/16
20/16
20
25
32
40
50S
20/16
20/16
20S
25
32
40
50S
63S
20S

PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED LSZH


Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs,
collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low
smoke zero halogen (LSZH) sheath, Blue or Black, to PAS5308 Part 1, Type 1 LSZH.
CCC
CODE
7246
7247
7248
7249
7250
7251

INSTRUMENTATION AND
CONTROL CABLES
NON-ARMOURED WITH
COLLECTIVE SCREEN
(0.5MM2 TO 1.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2

NO. OF
PAIRS

WEIGHT
KG/KM

1
2
5
10
20
30

69
99
242
380
684
989

OVERALL
DIAMETER
(MM)
6.30
7.30
13.30
17.70
23.50
28.50

BRASS
A2
GLAND
20/16
20/16
20
25
32
40

Temperature limits:
-20 to +65C.
*Bending radius:

Core identification:
Part 1 colour code chart on page 96.
Part 2 colour code chart on page 97.

5 x overall diameter.

Should not be installed at


temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

91

PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, each pair individually aluminium/mylar foil tape screened, complete
with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete
with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black.
Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
PAS5308 PART 2, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
each pair individually aluminium/mylar foil tape screened complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black.
Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
CCC CODE
PT1

PT2

7112
7113
7114
7115
7116
7117
7149
7150
7151
7152
7153
7154
7185
7186
7187
7188
-

7312
7313
7314
7315
7316
7317
*7349
7350
7351
7352
7353
7354
7385
7386
7387
7388
-

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5

16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
2
5
10
20
30
50
2
5
10
20
30
50
2
5
10
20
30
50

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
161
11.00
253
14.20
408
20.10
753
26.30
1153
31.30
1900
40.70
184
11.80
299
15.30
489
21.70
920
28.80
1445
34.50
2460
44.00
242
13.70
408
17.80
714
25.50
1337
33.40
2040
40.4
3260
52.2

BRASS
A2
GLAND
20S
25
32
40
40
50
20
25
32
40
50S
63S
25
25
32
50S
50
63

PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH


Plain annealed flexible copper conductors, XLPE insulated, laid up to form
pairs, each pair individually aluminium/mylar tape screened. Complete with
0.5mm2 drain wire, collective aluminium/mylar tape screen complete with
0.5mm2 drain wire, low smoke zero halogen (LSZH) outer sheath, Black or Blue,
generally to PAS5308 Part 1, Type 1 LSZH.
CCC
CODE
71149
71150
71151
71152
7253

INSTRUMENTATION AND
CONTROL CABLES
NON-ARMOURED WITH
INDIVIDUAL AND
COLLECTIVE SCREENS
(0.5MM2 TO 1.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75

24/0.20
24/0.20
24/0.20
24/0.20
24/0.2

NO. OF
PAIRS

WEIGHT
KG/KM

2
5
10
20
30

184
299
489
920
1445

OVERALL
DIAMETER
(MM)
11.80
15.30
21.70
28.80
34.50

BRASS
A2
GLAND
20
25
32
40
50S

Temperature limits:
-20 to +65C.
*Bending radius:

Core identification:
Part 1 colour code chart on page 96.
Part 2 colour code chart on page 97.

5 x overall diameter.

Should not be installed at


temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION AND CONTROL CABLES - PAS5308

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

92

INSTRUMENTATION AND CONTROL CABLES - PAS5308


PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2
drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer
sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts
1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PAS5308 PART 2, TYPE 2 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced
propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN
50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PT1

CCC CODE

7118
7119
7120
7121
7122
7123
7124
7125
7155
7156
7157
7158
7159
7160
7161
7162
7189
7190
7191
7192
7193
7194
7195
7196
7208
7209
7210
7211
7212
7213

PT2

7318
7319
7320
7321
7322
7323
7324
7325
7355
7356
7357
7358
7359
7360
7361
7362
7389
7390
7391
7392
7393
7394
7395
7396
7408
7409
7410
7411
7412
7413

CONDUCTOR STRANDING No. OF WEIGHT OVERALL


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER
(MM)
0.5
16/0.20
1
242
10.8
0.5
16/0.20
2
288
11.7
0.5
16/0.20
5
535
17.3
0.5
16/0.20
10
868
22.3
0.5
16/0.20
20
1466
28.5
0.5
16/0.20
30
1944
33.3
0.5
16/0.20
50
3360
41.5
0.5
16/0.20 1 TRIPLE 259
11.0
0.75
24/0.20
1
270
11.1
0.75
24/0.20
2
330
12.3
0.75
24/0.20
5
719
19.2
0.75
24/0.20
10
1150
24.7
0.75
24/0.20
20
1704
30.7
0.75
24/0.20
30
2570
36.9
0.75
24/0.20
50
4400
46.4
0.75
24/0.20 1 TRIPLE 288
11.4
1.5
7/0.53
1
312
12.3
1.5
7/0.53
2
397
13.7
1.5
7/0.53
5
918
21.5
1.5
7/0.53
10
1466
27.8
1.5
7/0.53
20
2519
35.1
1.5
7/0.53
30
3352
41.9
1.5
7/0.53
50
5310
53.4
1.5
7/0.53 1 TRIPLE 357
12.6
2.5
7/0.67
1
395
13.1
2.5
7/0.67
2
490
15.9
2.5
7/0.67
5
1430
26.5
2.5
7/0.67
10
2235
35.1
2.5
7/0.67
20
3935
46.7
2.5
7/0.67 1 TRIPLE 407
13.7

GLAND
SIZE
(MM)
20/16
20S
20
25
32
32
50S
20/16
20/16
20S
20
25
32
40
50S
20S
20S
20S
25
32
40
50S
63S
20S
20S
20
20
40
50
20S

CLEAT
SIZE
(MM)
0.5
0.5
0.7
0.9
1.2
1.4
1.8
0.5
0.5
0.5
0.8
1.0
1.2
1.6
2.0
0.5
0.5
0.6
0.9
1.1
1.4
1.8
TC9
0.5
0.6
0.6
1.1
1.4
2.0
0.6

PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED LSZH


Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs,
collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, low
smoke zero halogen bedding (LSZH), galvanised steel wire armour, low smoke zero
halogen (LSZH) sheath, Black or Blue, generally to PAS5308 Part 1, Type 2 LSZH.
CCC
CODE
7255
7256
7257
7258
7259
7260
7261
7289
7290
7291
7292
7293

INSTRUMENTATION AND
CONTROL CABLES
ARMOURED WITH
COLLECTIVE SCREEN
(0.5MM2 TO 2.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5

Temperature limits:
-20 to +65C.
*Bending radius:
6 x overall diameter..

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2
24/0.2
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
1
2
5
10
20
30
50
1
2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
270
10.70
330
11.90
719
18.80
1150
24.30
1704
30.30
2570
36.9
4400
46.4
312
11.90
397
13.30
918
21.10
1466
27.40
2519
35.50

GLAND
SIZE
(MM)
20/16
20S
20
25
32
40
50S
20S
20S
25
32
40

CLEAT
SIZE
(MM)
0.5
0.5
0.8
1.0
1.2
1.6
2.0
0.5
0.6
0.9
1.1
1.4

Core identification:
Part 1 colour code chart on page 96.
Part 2 colour code chart on page 97.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

93

PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, each pair individually aluminium/mylar foil tape screened, complete
with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete
with 0.5mm2 drain wire, polyethylene bedding, galvanised steel wire armour,
PVC outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PAS5308 PART 2, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
each pair individually aluminium/mylar foil tape screened, complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer
sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts
1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
CCC CODE
PT1

PT2

7130
7131
7132
7133
7134
7135
7167
7168
7169
7170
7171
7172
7201
7202
7203
7204
7205
7206

7330
7331
7332
7333
7334
7335
7367
7368
7369
7370
7371
7372
7401
7402
7403
7404
7405
7406

CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER SIZE
(MM)
(MM)
0.5
16/0.20
2
460
16.8
20
0.5
16/0.20
5
730
19.90
20
0.5
16/0.20
10
1202
26.90
32
0.5
16/0.20
20
1870
34.3
40
0.5
16/0.20
30
2620
40.5
50S
0.5
16/0.20
50
4180
51.5
50
0.75
24/0..20
2
518
16.60
20
0.75
24/0.20
5
805
21.00
25
0.75
24/0.20
10
1323
28.50
32
0.75
24/0.20
20
2323
36.80
40
0.75
24/0.20
30
3312
42.90
50S
0.75
24/0.20
50
5520
54.00
63S
1.5
7/0.53
2
707
19.40
20
1.5
7/0.53
5
1185
24.40
25
1.5
7/0.53
10
1668
32.50
32
1.5
7/0.53
20
2956
41.60
50S
1.5
7/0.53
30
3650
50.8
50
1.5
7/0.53
50
5640
62.6
63

CLEAT
SIZE
(MM)
0.7
0.8
1.1
1.4
1.6
TC9
0.7
0.9
1.2
1.6
1.8
TC9
0.8
1.0
1.4
1.8
TC9
TC10

PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH


Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs,
each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2
drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm2
drain wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour,
low smoke zero halogen (LSZH) sheath, Blue or Black, generally to PAS5308 Part 1,
Type 2 LSZH.
CCC CODE

7267
7268
7269
7270
7298
7299
7297
7296

INSTRUMENTATION AND
CONTROL CABLES
ARMOURED WITH
INDIVIDUAL AND
COLLECTIVE SCREEN
(0.5MM2 TO 1.5MM2)

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5

24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53

NO. OF
PAIRS
2
5
10
20
2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
518
16.60
805
21.00
1323
28.50
2323
36.80
707
19.40
1185
24.40
1668
32.50
2956
41.60

GLAND
SIZE
(MM)
20
25
32
40
20
25
32
50S

CLEAT
SIZE
(MM)
0.7
0.9
1.2
1.6
0.8
1.0
1.4
1.8

Temperature limits:
-20 to +65C.
*Bending radius:

Core identification:
Part 1 colour code chart on page 96.
Part 2 colour code chart on page 97.

6 x overall diameter.

Should not be installed at


temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION AND CONTROL CABLES - PAS5308

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

94

INSTRUMENTATION AND CONTROL CABLES - PAS5308


PAS5308 PART 1, TYPE 3 CONSTRUCTION, OVERALL SCREENED
Plain annealed copper conductors, polyethylene insulated, laid up to form
pairs, each pair individually aluminium/mylar foil tape screened complete
with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete
with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel
wire armour, PVC outer sheath reduced propagation. Blue or Black.
PAS5308 PART 2, TYPE 3 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, PVC insulated laid up to form pairs,
each pair individually aluminium/mylar foil tape screened complete with
0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour,
PVC outer sheath reduced propagation. Blue or Black.
CCC CODE
PT1

PT2

7821
7822
7823
7824
7825
7826
7827
7971
7972
7973
7974
7975
7976
7977
7851
7852
7853
7854
7855
7856
7857

7921
7922
7923
7924
7925
7926
7927
7951
7952
7953
7954
7955
7956
7957

CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER SIZE
(MM)
(MM)
(MM)
0.75
24/0.20
1
700
15.7
20
0.75
24/0.20
2
795
16.8
20
0.75
24/0.20
5
1598
25.1
25
0.75
24/0.20
10
2280
29.4
32
0.75
24/0.20
20
3630
37.3
40
0.75
24/0.20
30
4385
43.1
50S
0.75
24/0.20
50
6895
53.1
63S
1.0
1/1.13
1
710
15.8
20
1.0
1/1.13
2
828
17.0
20
1.0
1/1.13
5
1627
25.0
25
1.0
1/1.13
10
2275
29.6
32
1.0
1/1.13
20
3149
37.6
40
1.0
1/1.13
30
4420
42.6
50S
1.0
1/1.13
50
6964
53.5
63S
1.5
7/0.53
1
940
16.9
20
1.5
7/0.53
2
1051
19.0
20
1.5
7/0.53
5
1973
27.4
32
1.5
7/0.53
10
2823
33.2
32
1.5
7/0.53
20
4498
42.1
50S
1.5
7/0.53
30
6207
50.1
50
1.5
7/0.53
50
8961
61.0
63

CLEAT
SIZE
0.7
0.7
1.0
1.2
1.6
1.8
TC9
0.7
0.7
1.0
1.2
1.6
1.8
TC9
0.7
0.8
1.1
1.4
1.8
2.0
TC10

Temperature limits:
-20 to +63C.
*Bending radius:
5 x overall diameter.
Core identification:
Part 1 colour code chart on page 96.
Part 2 colour code chart on page 97.
Should not be installed at
temperatures below 0C.

INSTRUMENTATION AND
CONTROL CABLES
LEAD SHEATHED
ARMOURED WITH
COLLECTIVE SCREEN
(0.75MM2 TO 1.5MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

95

PAS5308 PART 1, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED


Plain annealed flexible copper conductors, polyethylene insulated, laid up to
form pairs, collective aluminium/mylar tape screen, complete with 0.5mm2
drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour,
PVC outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PAS5308 PART 2, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath
reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and
3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
CCC CODE
PT1

PT2

7830
7831
7832
7833
7834
7835
N/A
N/A
N/A
N/A
N/A
N/A
7870
7871
7872
7873
7874
7875

7930
7931
7932
7933
7934
7935
N/A
N/A
N/A
N/A
N/A
N/A
7970
7971
7972
7973
7974
7975

CONDUCTOR STRANDING No. OF WEIGHT OVERALL GLAND


SIZE (MM2)
(MM)
PAIRS KG/KM DIAMETER SIZE
(MM)
(MM)
(MM)
0.75
24/0.20
2
1280
21.5
25
0.75
24/0.20
5
1810
26.0
25
0.75
24/0.20
10
2720
32.7
32
0.75
24/0.20
20
4270
40.9
50S
0.75
24/0.20
30
6000
46.3
50S
0.75
24/0.20
50
8330
58.5
63S
1.0
1/1.13
2
1280
22.3
25
1.0
1/1.13
5
1820
27.2
25
1.0
1/1.13
10
2750
34.2
40
1.0
1/1.13
20
4350
43.8
50S
1.0
1/1.13
30
6110
51.4
50
1.0
1/1.13
50
8350
62.5
63
1.5
7/0.53
2
1680
25.5
25
1.5
7/0.53
5
2300
30.0
32
1.5
7/0.53
10
4000
40.1
50S
1.5
7/0.53
20
6300
50.2
50
1.5
7/0.53
30
8110
57.6
63S
1.5
7/0.53
50
11160
70.6
75S

CLEAT
SIZE
0.9
1.1
1.4
1.8
2.0
TC10
0.9
1.1
1.4
1.8
TC9
TC10
1.1
1.2
1.6
2.0
TC10
TC12

Temperature limits:
-20 to +65C.
*Bending radius:
15 x overall diameter.
Core identification:
Part 1 colour code chart on page 96.
Part 2 colour code chart on page 97.
Should not be installed at
temperatures below 0C.

INSTRUMENTATION AND
CONTROL CABLES
LEAD SHEATHED
ARMOURED WITH
INDIVIDUAL AND
COLLECTIVE SCREENS
(0.75MM2 TO 1.5MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION AND CONTROL CABLES - PAS5308

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

96

INSTRUMENTATION AND CONTROL CABLES PAS5308


PART 1 COLOUR CODING
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

A
WIRE
BLACK
BLACK
BLUE
BLACK
BLUE
GREEN
BLACK
BLUE
GREEN
BROWN
BLACK
BLUE
GREEN
BROWN
WHITE
BLACK
BLUE
GREEN
BROWN
WHITE
RED
BLACK
BLUE
GREEN
BROWN

B
WIRE
BLUE
GREEN
GREEN
BROWN
BROWN
BROWN
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
ORANGE
ORANGE
ORANGE
ORANGE
ORANGE
ORANGE
YELLOW
YELLOW
YELLOW
YELLOW

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
WHITE
RED
ORANGE
BLACK
BLUE
GREEN
BROWN
WHITE
RED
ORANGE
YELLOW
BLACK
BLUE
GREEN
BROWN
WHITE
RED
ORANGE
YELLOW
GREY
BLACK
BLUE
GREEN
BROWN
WHITE

B
WIRE
YELLOW
YELLOW
YELLOW
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

For individual screened pairs, identification will be Black/Blue numbered pairs.


Two pair collectively screened cables are in quad formation colour coded in
rotation, Black, Blue, Green, Brown.
Single triple will be Blue , Black, Green.

PAS5308 PART 1 CORE


IDENTIFICATION

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

97

PART 2 COLOUR CODING


PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
RED/BLUE
RED/BLUE
RED/BLUE
RED/BLUE
RED/BLUE
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
ORANGE/RED
ORANGE/RED
ORANGE/RED
ORANGE/RED
ORANGE/RED

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

For individual screened pairs, identification will be White/Blue numbered pairs.


Two pair collectively screened cables are in quad formation colour coded in
rotation, Black, Blue, Green, Brown.
Single triple will be Blue, White, Orange.

PAS5308 PART 2 CORE


IDENTIFICATION

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION AND CONTROL CABLES PAS5308

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

98

INSTRUMENTATION AND CONTROL CABLES BSC


(CORUS) STANDARD
Plain annealed flexible copper conductors, PVC bedding, tinned annealed
copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC
outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20
part 4, Type 134. Flame propagation to BS EN 50265 and IEC 60332-1.
CCC
CODE

CONDUCTOR STRANDING
SIZE (MM2)
(MM)

BSC1342C
BSC1343C
BSC1344C
BSC1347C
BSC13412C
BSC13419C
BSC13427C
BSC13437C

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75

Temperature limits:
-20 to +70C.
*Bending radius:

24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2

NO. OF
CORES
2
3
4
7
12
19
27
37

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
420
13.4
452
13.8
490
14.4
579
15.9
906
19.5
1091
21.5
1562
25.5
1872
28.1

GLAND
SIZE
(MM)
20S
20S
20S
20S
20
20
25
32

SINGLE
CLEAT
0.6
0.6
0.6
0.7
0.8
0.9
1.1
1.2

Should not be installed at


temperatures below 0C.

6 x overall diameter.
CORE IDENTIFICATION:
NO. OF
CORES
2
3
4
7
12
19

27

37

INSTRUMENTATION CABLE
TO BRITISH STEEL
SPECIFICATION
CES20 TYPE 134
(0.75MM2)

COLOUR
BROWN
BLUE
BROWN
BLUE
GREEN/YLW
BROWN
GREY
GREEN/YLW
BLACK
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE RED/GREEN RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE RED/GREEN
RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK
BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE RED/GREEN
RED/YELLOW RED/WHITE RED/BLACK RED/BROWN BLUE/YELLOW BLUE/WHITE BLUE/BLACK
BLUE/ORANGE BLUE/GREEN BLUE./GREY GREEN/YLW GREEN/WHITE GREEN/BLACK GRN/ORANGE
GREEN/GREY BROWN/YLW BRN/WHITE BRN/BLACK BROWN/GREY VIOLET/YLW VIOLET/BLACK
VIOLET/WHT RED/GREY

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

99

Tinned annealed flexible copper conductors, PVC insulated and laid up to form
pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2
drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath.
Orange. 300/500 volts grade. Type 143. Flame propagation to BS EN 50265
and IEC 60332-1.
CCC
CODE
BSC1431P
BSC1432P
BSC1435P
BSC14310P
BSC14320P
BSC14330P
BSC14350P

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.75
0.75
0.75
0.75
0.75
0.75
0.75

NO. OF
PAIRS

24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20

Temperature limits:
-20 to +70C.
*Bending radius:

1
2
5
10
20
30
50

WEIGHT OUTSIDE
KG/KM DIAMETER
(MM)
260
10.70
320
11.90
672
18.80
1112
24.30
1665
30.30
2525
36.5
4137
46

GLAND
SIZE
(MM)
20/16
20S
20
25
32
40
50

SINGLE
CLEAT
0.5
0.5
0.8
1.0
1.2
1.6
2.0

Should not be installed at


temperatures below 0C.

6 x overall diameter.
CORE IDENTIFICATION ACCORDING TO ENATS 09-6 SECTION 3
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

INSTRUMENTATION CABLE
TO BRITISH STEEL
SPECIFICATION
CES20 TYPE 143
(0.75MM2)

A
WIRE
BLACK
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
BLUE
ORANGE
ORANGE
ORANGE
ORANGE
GREEN
GREEN
GREEN
BROWN
BROWN
GREY
BLACK
BLACK
BLACK
BLACK
WHITE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
GREEN
BROWN
GREY
WHITE
BROWN
GREY
WHITE
GREY
WHITE
WHITE
RED
YELLOW
VIOLET
RED

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
WHITE
WHITE
BLUE
BLUE
BLUE
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
GREY
GREY
ORANGE
ORANGE
YELLOW
YELLOW
BROWN
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

B
WIRE
YELLOW
VIOLET
RED
YELLOW
VIOLET
RED
YELLOW
VIOLET
GREY
ORANGE
YELLOW
BROWN
VIOLET
YELLOW
VIOLET
YELLOW
VIOLET
BROWN
VIOLET
VIOLET
BLACK
BLUE
RED
ORANGE
YELLOW

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

INSTRUMENTATION AND CONTROL CABLES BSC


(CORUS) STANDARD

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

100

INTERNAL TELEPHONE CABLES TYPE CW1308


Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC
sheathed. To BPO CW(M) 1308. Sheath colour: White. Flame propagation to
BS4066 PT1 and IEC 332 PT1.
CCC
CODE

STRANDING
(MM2)

No. OF
PAIRS

WEIGHT
KGS/KM

13000
13001
13002
13004
13005
13006
13013
13007
13008
13009
13010
13012
13014
13016
13018
13020
13022
13023

1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50

2
3
4
6
10
10+E
12
15
20+E
25+E
30+E
40+E
50+E
60+E
80+E
100+E
160+E
320+E

18
24
35
47
70
102
80
95
126
163
200
273
365
412
501
687
1135
2306

E. denotes earth core.


Temperature limits:
-20 to +70C.

OVERALL
DIAMETER
(MM)
3.6
4.5
5.8
6.8
8.3
8.6
9.1
9.8
10.7
11.4
12.2
15
17.5
20
22.5
24
30.5
39.5

GLAND
SIZE
(MM)
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20
20
20
25
25
32
32
32
40
50

*Bending radius:
5 x overall diameter.
Should not be installed at
temperatures below 0C.

CORE IDENTIFICATION:
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

INTERNAL TELEPHONE
CABLE TYPE CW1308

A
B
WIRE
WIRE
WHITE/BLUE BLUE/WHITE
WHITE/ORANGE ORANGE/WHITE
WHITE/GREEN GREEN/WHITE
WHITE/BROWN BROWN/WHITE
WHITE/GREY
GREY/WHITE
RED/BLUE
BLUE/RED
RED/ORANGE ORANGE/RED
RED/GREEN
GREEN/RED
RED/BROWN BROWN/RED
RED/GREY
GREY/RED
BLACK/BLUE
BLUE/BLACK
BLACK/ORANGE ORANGE/BLACK
BLACK/GREEN GREEN/BLACK
BLACK/BROWN BROWN/BLACK
BLACK/GREY
GREY/BLACK

PAIR
NUMBER
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

A
B
WIRE
WIRE
YELLOW/BLUE BLUE/YELLOW
YELLOW/ORANGE ORANGE/YELLOW
YELLOW/GREEN GREEN/YELLOW
YELLOW/BROWN BROWN/YELLOW
YELLOW/GREY GREY/YELLOW
VIOLET/BLUE BLUE/VIOLET
VIOLET/ORANGE ORANGE/VIOLET
VIOLET/GREEN GREEN/VIOLET
VIOLET/BROWN BROWN/VIOLET
VIOLET/GREY GREY/VIOLET
PINK/BLUE
BLUE/PINK
PINK/ORANGE ORANGE/PINK
PINK/GREEN
GREEN/PINK
PINK/BROWN BROWN/PINK
PINK/GREY
GREY/PINK

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

101

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13050
13051
13052
13053
13054
13055
13056

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.28
0.28
0.28
0.28
0.28
0.28
0.28

1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6

NO. OF
PAIRS
**2
5
10
20
30
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
170
9
238
12.07
454
15.91
496
17.18
697
18.1
1243
26.60
1825
29.8

GLAND
SIZE
(MM)
20/16
20S
20
20
20
32
32

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.7
0.8
1.1
1.2

Core identification:
See colour chart on page 104.

** 2 pair laid up in quad formation.


Temperature limits:
-20 to +70C.

Should not be installed at


temperatures below 0C.

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13081
13083
13084
13085
13086
13087
13088
13089
13090
13091

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63

1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9

NO. OF
PAIRS
**2
5
10
15
20
25
30
40
50
60
75
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
206
10.31
333
14.1
586
17.38
796
19.5
939
22.48
1245
21.3
1400
23.9
1686
28.2
1952
32.87
2183
35
2342
37
3613
41.8

GLAND
SIZE
(MM)
20S
20S
20
20
25
25
25
32
32
40
40
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.8
0.9
0.9
1.0
1.2
1.4
1.4
1.6
1.8

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13101
13103
13104
13105
13106
13107
13108
13109
13110
-

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63

1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9

NO. OF
PAIRS
**2
5
10
15
20
25
30
40
50
100

** 2 pair laid up in quad formation.

PVC INSULATED
MULTIPAIR ARMOURED
CABLE TO ESI
STANDARD

Temperature limits:
-20 to +70C.
*Bending radius: 6 x overall diameter.

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
213
10.4
379
14
650
17.8
805
20
955
21.7
1256
24.3
1413
25.9
1700
28.6
2110
31.5
3628
42

GLAND
SIZE
(MM)
20/16
20S
20
20
25
25
25
32
32
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.8
0.8
0.9
1.0
1.1
1.2
1.4
1.8

Core identification:
See colour chart on page 104.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

COMMUNICATION CABLES - TELEPHONE ENATS 09-6

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

102

COMMUNICATION CABLES - TELEPHONE ENATS 09-6


Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13381
13383
13384
13385
13386
13387
13388
13389
13390
13391

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8

NO. OF
PAIRS
**2
5
10
15
20
25
30
40
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
208
10.17
353
13.92
606
17.49
630
18.9
854
21.06
1159
23.2
1266
26.47
1549
28.82
1923
33.5
3000
43.4

GLAND
SIZE
(MM)
20S
20S
20
20
25
25
32
32
32
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.8

Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

PVC INSULATED
MULTIPAIR ARMOURED
CABLE TO ESI
STANDARD

13401
13403
13404
13405
13406
13407
13408
13409
13410
13411

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8

NO. OF
PAIRS
**2
5
10
15
20
25
30
40
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
223
10.3
349
13.74
599
18.14
795
19.4
900
22.34
1159
23.5
1332
25.21
1435
28
1926
31.44
3041
44.7

GLAND
SIZE
(MM)
20S
20S
20
20
25
25
25
32
32
50S

CLEAT
SIZE
SINGLE
0.5
0.6
0.8
0.8
0.9
1.0
1.0
1.2
1.4
1.8

Solid tinned annealed copper, polyethylene insulated, low smoke and zero
halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero
halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5.
CCC
CODE
13501
13503
13504
13506
13510
13511

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5
0.5
0.5

1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8

NO. OF
PAIRS
**2
5
10
20
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
200
9.5
326
13.7
598
17.47
783
20.7
1823
20.74
3041
41

GLAND
SIZE
(MM)
20/16
20S
20
25
25
50S

CLEAT
SIZE
SINGLE
0.6
0.7
0.9
0.9
1.8

Solid tinned, annealed copper conductors, polyethylene insulated, twisted to form


pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain, wire,
low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke
and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5.
CCC
CODE
13601
13603
13604
13606

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.5
0.5
0.5
0.5

NO. OF
PAIRS

1/0.8
1/0.8
1/0.8
1/0.8

**2 pair laid up in quad formation.


Temperature limits:
-20 to +70C.
*Bending radius: 8 x overall diameter.

**2
5
10
20

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
260
10.9
328
14.33
602
17.22
790
20.8

GLAND
SIZE
(MM)
20S
20S
20
25

CLEAT
SIZE
SINGLE
0.5
0.6
0.7
0.9

Core identification:
See colour chart on page 104.
Should not be installed at
temperatures below 0C or 40C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

103

Stranded plain annealed copper conductor,PVC insulated, PVC bedding,


galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to
BS6346 / ENATS 09-6. Flame retardant to IEC 60332-3-24c.
CCC
CONDUCTOR STRANDING
CODE
SIZE (MM)
6942X2/5ESI
2.5
7/0.67
6943X2/5ESI
2.5
7/0.67
6944X2/5ESI
2.5
7/0.67
6947X2/5/7
2.5
7/0.67
6940/12X2/5/7
2.5
7/0.67
6940/19X2/5/7
2.5
7/0.67
6940/27X2/5/7
2.5
7/0.67
6940/37X2/5/7
2.5
7/0.67

NO. OF
CORES
2
3
4
7
12
19
27
37

WEIGHT OVERALL GLAND SIZE SINGLE


(KG/KM) DIAMETER
(MM)
CLEAT
329
12.2
20S
0.5
396
13.5
20S
0.6
423
14.4
20
0.6
672
17.2
20
0.7
967
21.3
25
0.9
1482
25.4
25
1.1
1920
29.3
32
1.2
2185
33.1
40
1.4

Should not be installed at


temperatures below 0C or
above 40C.

Temperature limits:
-30 to +70C
*Bending radius:
6 x Overall Diameter
Core identification:
White numbered cores.

COMMUNICATION CABLES - TELEPHONE ENATS 09-6


PVC AND PE INSULATED
ARMOURED CABLES TO
ENATS STANDARD

Solid plain annealed copper conductor, polyethylene insulated, polyethylene


bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6
issue 6 section 3 table 2 - induced voltage between the pairs up to 15kv.
CCC CODE
13187
13188
-

CONDUCTOR STRANDING
SIZE (MM)
0.5
1/0.8
0.5
1/0.8
0.5
1/0.8

Temperature limits:
-20 to +70C
*Bending radius:

NO. OF
PAIRS
7
19
37

WEIGHT
900
1800
3000

OVERALL GLAND
SINGLE
DIAMETER SIZE (MM) CLEAT
22.5
25
0.9
32.1
32
1.4
41.7
50S
1.8

Should not be installed at


temperatures below 0C or
above 40C.

8 x Overall Diameter
Core identification:
7 pair: centre - red & yellow.
outer layer - black & violet, orange & grey**, green & brown, orange & blue**,
green & brown, orange & white**.
19 pair: centre - centre and first layer as 7 pair.
outer layer - black & violet, odd pairs red & yellow, even pairs green & brown,
blue & white.
37 pair: centre, first and second layer as 19 pair.
outer layer - black & violet, odd pairs red & yellow, even pairs green & brown,
blue & white.
**denotes carrier pairs.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

UTILITY INDUSTRY PVC CONTROL CABLES, ENATS 09-6

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

104

CORE IDENTIFICATION ACCORDING TO ENATS 3.6 AND 4.5


SECTION 3.6 COLOUR CODING
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

ENATS 09-6 SECTION


3.6 AND 4.5
CORE IDENTIFICATION

A
WIRE
BLACK
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
BLUE
ORANGE
ORANGE
ORANGE
ORANGE
GREEN
GREEN
GREEN
BROWN
BROWN
GREY
BLACK
BLACK
BLACK
BLACK
WHITE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
GREEN
BROWN
GREY
WHITE
BROWN
GREY
WHITE
GREY
WHITE
WHITE
RED
YELLOW
VIOLET
RED

PAIR
NUMBER
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

A
WIRE
WHITE
WHITE
BLUE
BLUE
BLUE
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
GREY
GREY
ORANGE
ORANGE
YELLOW
YELLOW
BROWN
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

B
WIRE
YELLOW
VIOLET
RED
YELLOW
VIOLET
RED
YELLOW
VIOLET
GREY
ORANGE
YELLOW
BROWN
VIOLET
YELLOW
VIOLET
YELLOW
VIOLET
BROWN
VIOLET
VIOLET
BLACK
BLUE
RED
ORANGE
YELLOW

All two pair cables are in quad formation and colour coded in rotation Blue, Orange, Green, Brown.
SECTION 4.5 COLOUR CODING
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

All two pair cables are in quad


formation and colour coded in
rotation - White, Red, Blue, Orange.
For 30 pair cables the formation will
be 3 X 10 pair units numbered - 1, 2
and 3.

Each unit is lapped with coloured


tape for identification as follows
UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6
UNIT 7
UNIT 8
UNIT 9
UNIT10

BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
RED
BLACK
YELLOW
VIOLET

If sub-units are used, binders


for corresponding sub-units
shall be the same colour.

For 40 pair cables the formation will be


2 X 20 pair units numbered - 1 and 2.
For 50 pair cables the formation will
be 5 X 10 pair units numbered - 1, 2
3, 4 and 5.
For 100 pair cables the formation will
be 5 X 20 pair units numbered - 1, 2,
3, 4 and 5.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

105

Solid plain annealed copper conductors, cellular polyethylene insulated,


petroleum jelly filled, PE outer sheath. Black. To CW1128A. Flame propogation
to BS4066 PT1 and IEC 332 PT1.
CCC
CODE

STRANDING
(MM)

NO. OF
CORES

WEIGHT
KG/KM

OVERALL
DIAMETER

GLAND
SIZE

13030
13031
13032
13034
13035

1/0.50
1/0.50
1/0.50
1/0.50
1/0.50

5
10
20
50
100

48
82
182
317
613

6.83
7.41
11.48
15.5
21.78

20/16
20/16
20
25
32

CLEAT
SIZE
(MM)
0.5
0.7
0.9

Solid plain annealed copper conductors, cellular polyethylene insulated,


petroleum jelly filled solid polyethylene bedding, galvanised steel wire armour,
PE outer sheath. Black. To BPO CW 1128A/1198A. (Concentric construction).
Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13040
13041
13042
13043
13044

PETROLEUM
JELLY FILLED TELEMETRY
CABLE TO CW1128,
CW1128/1198 AND
BS3573

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.196
0.196
0.196
0.196
0.196

NO. OF
PAIRS

1/0.5
1/0.5
1/0.5
1/0.5
1/0.5

5
10
20
50
100

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
(MM)
199
10.63
276
12.4
461
16.23
920
21.66
1416
26.58

GLAND
SIZE
SINGLE
20S
20S
20
25
32

CLEAT
SIZE
0.5
0.5
0.7
0.9
1.1

Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum


jelly filled, collective aluminium/mylar tape screen, polyethylene bedding,
galvanised steel wire armour, PVC outer sheath. Black. To BS3573 and
CW1128/1198. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
13150
13151
13153
13154

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
0.63
0.63
0.63
0.63

NO. OF
PAIRS

1/0.9
1/0.9
1/0.9
1/0.9

5
10
20
50

WEIGHT OVERALL
KG/KM DIAMETER
(MM)
(MM)
392
16.7
620
19.9
1078
24.8
2155
34.5

GLAND
SIZE
SINGLE
20
20
25
40

CLEAT
SIZE
0.7
0.8
1.0
1.6

COLOUR SCHEME FOR BS3573 - UNIT CONSTRUCTION


PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

Cables may be manufactured using 5pair sub-units coloured as 1-5 and 6-10

UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6
UNIT 7
UNIT 8
UNIT 9
UNIT 10

BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
RED
BLACK
YELLOW
VIOLET

If sub-units are used binders for


corresponding sub-units shall be the
same colour.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

COMMUNICATION CABLES PETROLEUM JELLY FILLED

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

106

DEFENCE STANDARD 61-12 CONTROL CABLES


Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder
tape, tinned annealed copper wire braid screen, PVC outer sheath. Black. 440 volts
grade. To Ministry of Defence Standard DEF 61-12 (Part 4 for 7/0.2 conductors, Part
5 for 16/0.2 conductors). Flame propogation to BS4066 PT1 and IEC 332 PT1.
CCC
CODE
722C
723C
724C
726C
728C
7212C
7218C
7225C
7236C
7250C
7260C
1622C
1623C
1624C
1626C
1628C
16210C
16212C
16218C
16225C
16236C
16250C
16260C

CONDUCTOR STRANDING
SIZE (MM2)
(MM2)
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
6
8
12
18
25
36
50
60
2
3
4
6
8
**10
12
18
25
36
50
60

23
27
32
55
69
83
110
150
200
270
310
69
79
92
120
146
190
198
250
320
450
564
670

OVERALL
DIAMETER
(MM)
4.1
4.3
4.6
5.9
6.0
7.2
8.5
9.8
11.2
13.0
13.8
6.9
7.2
7.7
8.7
8.9
11.8
11.0
12.5
14.6
16.7
18.5
20.3

GLAND
SIZE
(MM)
16
16
16
16
16
16
20
20
20
25
25
16
16
16
20
20
20
20
20
25
25
32
32

Tinned annealed flexible copper conductors, low smoke and zero halogen
(LSZH) insulation, non-hygroscopic binder tape, tinned annealed copper wire
braid screen, low smoke and zero halogen (LSZH) outer sheath. Black. 440 volt
grade. Generally to ministry of Defence Standard DEF61-12 Part 5 LSF.
CCC
CODE
LSF1622C
LSF1623C
LSF1624C
LSF1626C
LSF16212C
LSF16218C
LSF16225C

CONDUCTOR STRANDING
SIZE (MM2)
(MM2)
0.50
0.5
0.5
0.5
0.5
0.5
0.5

16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20

** Laid up in a pair configuration.


Temperature limits:
-55 to +70C.
*Bending radius:

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
6
12
18
25

69
79
92
120
198
250
320

OVERALL
DIAMETER
(MM)
6.9
7.2
7.7
8.7
11.0
12.5
14.6

GLAND
SIZE
(MM)
16
16
16
20
20
20
25

Core identification:
See colour chart on page 107.
Should not be installed at
temperatures below 0C.

6 x overall diameter.

DEFENCE
STANDARD SCREENED
MULTICORE
CABLE C TYPE

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

107

COLOUR CODING
CORE
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
35
36

COLOUR
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
VIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE
GREEN/RED
YELLOW/RED
WHITE/RED
RED/BLACK
YELLOW/BLUE
YELLOW/BLUE
WHITE/BLUE
BLUE/BLACK
ORANGE/BLUE
GREEN/BLUE
GREY/BLUE
YELLOW/GREEN
WHITE/GREEN
GREEN/BLACK
ORANGE/GREEN
GREY/GREEN
YELLOW/BROWN
WHITE/BROWN
BROWN/BLACK
GREY/BROWN
YELLOW/VIOLET
VIOLET/BLACK
VIOLET/BLACK
WHITE/VIOLET

Where 2 colours are shown the core


is striped e.g. Red/Blue - the core is
striped Red with Blue.

DEFENCE
STANDARD 61-12
PARTS 4 & 5 CORE
IDENTIFICATION

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

DEFENCE STANDARD 61-12 CONTROL CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

108

COMPENSATING AND THERMOCOUPLE CABLES


NON-ARMOURED
Plain annealed flexible conductors, PVC insulated, laid up to form pairs,
collective aluminium mylar foil tape screen, complete with 0.5mm2 drain
wire, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1
and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1.
NO OF
PAIRS

SIZE
(MM2)

1
2
5
10
20

0.75
0.75
0.75
0.75
0.75

STRANDING OVERALL GLAND


(MM)
DIAMETER SIZE
(MM)
(MM)
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20

6.7
7.7
13.7
18.1
23.9

Temperature limits:
-30 to +105C.
*Bending radius:

20/16
20/16
25
25
32

JX
CCC
CODE
7500
7501
7503
7505
7507

KCB
KX
CCC
CCC
CODE
CODE
(WAS VX)
7530
7570
7531
7571
7533
7573
7537
7575
7539
7577

TX
CCC
CODE
7550
7551
7553
7557
7559

Core identification:
See colour chart on page 93.
Should not be installed at
temperatures below 0C.

5 x overall diameter.

ARMOURED
Plain annealed flexible conductors, PVC insulated, laid up to form pairs,
collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Thermocouple
wires calibrated to BS4937, ANSI 96.1 and IEC 584.3.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
NO OF
PAIRS

SIZE
(MM2)

1
2
5
10
20

0.75
0.75
0.75
0.75
0.75

Temperature limits:
-30 to +105C.
*Bending radius:
6 x overall diameter.

PVC INSULATED
COLLECTIVE SCREENED
THERMOCOUPLE
EXTENSION AND
COMPENSATING CABLE
(0.75MM2)

STRANDING OVERALL GLAND


(MM)
DIAMETER SIZE
(MM)
(MM)
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20

11.1
12.3
19.2
24.7
30.7

20/16
20/16
20
25
32

JX
CCC
CODE
7600
7601
7603
7605
7607

KCB
KX
CCC
CCC
CODE
CODE
(WAS VX)
7640
7700
7641
7701
7643
7703
7645
7705
7647
7707

TX
CCC
CODE
7660
7661
7663
7665
7667

Core identification:
See colour chart on page 109.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

109

COLOUR CODING
EX

JX

KX

NX

TX

UX

VX

+-

+-

+-

+-

+-

+-

+-

CODE

BRITISH
BS1843: 1952

+-

+-

+-

+-

+-

+-

+-

AMERICAN
ANSI

+-

+-

+-

+-

+-

GERMAN
DIN

+-

+-

+-

+-

RC/SC

KCB

+-

+-

IEC 584-3

+-

COLOUR CODING OF
THERMOCOUPLE
EXTENSION AND
COMPENSATING CABLE

+-

+-

+-

+-

+-

IEC 584-3
INTRINSICALLY
SAFE

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

COMPENSATING AND THERMOCOUPLE CABLES

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

110

TRAFFIC SIGNALLING CABLES


TRAFFIC CONTROL CABLE WITH ARMOUR
Plain annealed solid copper conductors, PVC insulated, PVC bedding, galvanised
steel wire armour, PVC outer sheath, colour orange, generally to BS6346/87
CCC
CODE
TRAF4X1
TRAF8X1
TRAF12X1
TRAF16X1
TRAF20X1
TRAF4X1/5
TRAF8X1/5
TRAF12X1/5
TRAF16X1/5
TRAF20X1/5
TRAF8X1ESWA*

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.0

1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.38
1/1.38
1/1.38
1/1.38
1/1.38
1/1.13

NO. OF
CORES

WEIGHT
KG/KM

4
8
12
16
20
4
8
12
16
20
8

325
413
567
774
905
363
534
704
836
1040
533

OVERALL
DIAMETER
(MM)
13.3
15.6
17.9
19.9
22.0
12.5
15.8
18.5
20.0
21.5
16.3

GLAND
SIZE
(MM)
20S
20S
20
20
25
20S
20
20
20
25
20

LOOP FEEDER CABLE NON ARMOURED


Plain annealed solid copper conductors, PVC insulated, PVC sheathed, colour
orange, generally to BS6346/87, 600/1000v grade.
CCC
CODE

PVC INSULATED
ARMOURED
TRAFFIC SIGNAL CABLE,
LOOP FEEDER CABLE
AND LOOP
DETECTOR CABLE

TRAF8X1NA
TRAF12X1NA
TRAF8X1E*

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.0
1.0
1.0

1/1.13
1/1.13
1/1.13

NO. OF
CORES

WEIGHT
KG/KM

8
12
8

218
305
523

OVERALL
DIAMETER
(MM)
12.6
13.5
14.49

BRASS
A2
GLAND
20
25
25

Temperature limits:
-15 to +70C.
Core identification:
4 core - Red, Blue, Yellow, Green.
8 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange.
* includes additional 6mm2 integral
earth conductor
12 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue Violet.
16 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue, Violet,
Brown/Red, Yellow/Red, Grey/Red,
Black/Red.
20 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue, Violet,
Brown/Red, Yellow/Red, Grey/Red,
Black/Red, Violet/Red, Orange/Red,
Green/Red, Blue/White.
Should not be installed at
temperatures below 0C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

111

LOOP FEEDER CABLE NON ARMOURED


Plain annealed solid copper conductors, polyethylene insulated, polyethylene
outer sheath, colour orange, 600/1000v grade.
CCC
CODE
LOOP2X1/5
LOOP4X1/5
LOOP2X2/5
LOOP4X2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5

1/1.38
1/1.38
1/1.78
1/1.78

NO. OF
CORES

WEIGHT
KG/KM

2 (1pr)
4 (2pr)
2 (1pr)
4 (2pr)

80
123
110
180

OVERALL
DIAMETER
(MM)
9.0
9.1
9.3
10.7

GLAND
SIZE
(MM)
20S
20S
20S
20S

Temperature limits:
-15 to +70C.
*Bending radius:

Core identification:
2 core - Brown, Blue
4 core - Brown, Black, Grey, Blue.

6 x overall diameter.

Should not be installed at


temperatures below 0C.

TRAFFIC CONTROL CABLE ARMOURED


Plain annealed solid copper conductors, polyethylene insulated, polyethylene
bedding, galvanised steel wire armour, polyethylene outer sheath. Generally to
BS6346/87. Outer sheath colour: Orange. 600/1000 volts grade.
CCC
CODE
LOOP2X1/5SWA
LOOP4X1/5SWA
LOOP2X2/5SWA
LOOP4X2/5SWA

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
2.5
2.5

1/1.38
1/1.38
1/1.78
1/1.78

NO. OF
CORES

WEIGHT
KG/KM

2 (1pr)
4 (2pr)
2 (1pr)
4 (2pr)

235
300
279
383

OVERALL
DIAMETER
(MM)
11.8
12.7
12.5
15.0

GLAND
SIZE
(MM)
20S
20S
20S
20

Temperature limits:
-15 to +70C.
*Bending radius:

Core identification:
2 core - Brown, Blue
4 core - Brown, Black, Grey, Blue.

6 x overall diameter.

Should not be installed at


temperatures below 0C.

LOOP DETECTOR CABLE


Tinned flexible copper conductor, ethylene propylene rubber insulated (EPR),
polychloroprene sheathed (PCP), 600/100v generally to BS6500 + BS6195,
sheath colour black.
CCC
CODE
LOOP1/5
LOOP2/5

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
2.5

NO. OF
CORES

WEIGHT
KG/KM

1
1

53.8
64.0

30/.025
50/0.25

Temperature limits:
-30 to +85C.
*Bending radius: 6 x overall diameter.

PVC INSULATED
ARMOURED
TRAFFIC SIGNAL CABLE,
LOOP FEEDER CABLE
AND LOOP
DETECTOR CABLE

OVERALL
DIAMETER
(MM)
7.0
7.9

GLAND
SIZE
(MM)
20S
20S

Should not be installed at


temperatures below -25C.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES

TRAFFIC SIGNALLING CABLES

113

DATA AND COAXIAL CABLES

DATA AND
COAXIAL CABLES

114

DATA, COAXIAL AND LAN CABLES


BELDEN EQUIVALENTS:
8138/SWA/LSF 8 PAIR 28AWG COLLECTIVE SCREEN PLUS STEEL WIRE ARMOUR,LSF SHEATH.
8471
1 PAIR 16AWG UNSCREENED, PVC SHEATH.
8471/LSF
1 PAIR 16AWG UNSCREENED, PVC SHEATH.
8719
1 PAIR 16AWG COLLECTIVE SCREEN, PVC SHEATH.
8719/LSF
1 PAIR 16AWG COLLECTIVE SCREEN, LSF SHEATH.
8723/LSF
2 PAIR 22AWG INDIVIDUAL SCREEN ,LSOH SHEATH.
8723/SWA/LSF 2 PAIR 22AWG INDIVIDUAL SCREEN PLUS STEEL WIRE ARMOUR, LSF SHEATH.
8760
1 PAIR 18AWG COLLECTIVE SCREEN. PVC SHEATH.
8760/LSF
1 PAIR 18AWG COLLECTIVE SCREEN. LSOH SHEATH.
8761
1 PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH.
8761/LSF
1 PAIR 22AWG INDIVIDUAL SCREEN, LSOH SHEATH.
1 PAIR 20AWG COLLECTIVE SCREEN, PVC SHEATH.
8762
8762/LSF
1 PAIR 20AWG COLLECTIVE SCREEN, LSOH SHEATH.
3 PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH.
8777
8778
6 PAIR 22AWG INDIVIDUAL SCREEN, PVC SHEATH.
1 PAIR 22AWG COLLECTIVE SCREEN, PVC SHEATH.
9182
9463
TWIN AXIAL 20AWG, PVC SHEATH.
9463/SWA/PVC TWIN AXIAL 20AWG PLUS STEEL WIRE ARMOUR, PVC SHEATH.
9501
1 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH.
9501/LSF
1 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9502
2 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH.
9502/LSF
2 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9503
3 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH.
9503LSF
3 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9504
4 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH.
9504LSF
4 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9505LSF
5 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9506
6 PAIR 24AWG COLLECTIVE SCREEN, PVC SHEATH.
9506LSF
6 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9729
2 PAIR 24AWG INDIVIDUAL SCREEN, PVC SHEATH.
9773
3 PAIR 18AWG INDIVIDUAL SCREEN, PVC SHEATH.
9841LSF
1 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.
9842LSF
2 PAIR 24AWG COLLECTIVE SCREEN, LSOH SHEATH.

DATA AND
COAXIAL CABLES

COAXIAL CABLES
CT100
CT100LSOH
WF100BK
WC100BK
WF125BR
CT125
CT125LSOH
CT125BR
CT125RBS
CT167
CT167RBS
RG11AU
RG11SWA
RG58
RG59BU
RG59LSOH
RG59SWA
RG62AU
RG62SWA
URM202
URM203
URM70

75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, PE DIELECTRIC, PVC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PVC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, DIRECT BURIAL SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PVC SHEATH.
75OHMDOUBLESCREENED,LOWLOSSCOAX,FOAMFILLED,DIRECTBURIALSHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH.
75OHMBRAIDEDSCREEN,SOLIDPEDIELECTRICPLUSSTEELWIREARMOUR,PVCSHEATH.
50 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, LSOH SHEATH.
75OHMBRAIDEDSCREEN,SOLIDPEDIELECTRICPLUSSTEELWIREARMOUR,PVCSHEATH.
93 OHM BRAIDED SCREEN, PETUBE AND THREAD, PVC SHEATH.
93 OHM BRAIDED SCREEN, PETUBE AND THREAD PLUS SWA, PVC SHEATH.
75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH.
75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PVC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PVC SHEATH.

UTP CABLES
4UTPCAT5E
4UTPCAT5EBU
4UTPCAT5ELSF
4FTPCAT5E
4FTPCAT5ELSF
4UTPCAT5EDUCT
4FTPCAT5EDUCT
4FTPCAT5ESWA
4UTPCAT6
4UTPCAT6LSF

ENHANCED UNSCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH.


ENHANCED UNSCREENED 4 PAIR CAT 5 E, BLUE PVC SHEATH.
ENHANCED UNSCREENED 4 PAIR CAT 5 E, LSFVIOLET SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E, GREY PVC SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E, LSFVIOLET SHEATH.
ENHANCED UNSCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E PLUS SWA, LSF BLACK SHEATH.
UNSCREENED 4 PAIR CAT 6, GREY PVC SHEATH.
UNSCREENED 4 PAIR CAT 6, LSFVIOLET SHEATH.

115

RAILWAY CABLES

RAILWAY CABLES

RAILWAY CABLES

116

RAILWAY SIGNALLING CABLES


Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS76552.3 for types B1, LSZH insulated for types A1, A2, A3. Heavy duty PCP RS2 sheath
for types A1 & B1, LSZH sheath for types A2 & A3. Manufactured to Network Rail
specification NR/PS/SIG/00005 (formerly RT/E/PS/00005).

RAILWAY CABLES
SIGNALING
(0.75MM2 - 95MM2)

CCC
CODE

RAIL
CODE

A11X/75BR
A11X/75RD
A11X/75OR
A11X/75GY
A11X/75VIR
A11X/75BK
A11X115BK
A21X/75
A21X115
A32X/75
A34X/75
A36X/75
A310X/75
A314X/75
A336X/75
A348X/75
B11X2/5
B11X10
B11X35
B22X1/5
B22X2/5
B22X10
B22X16
B22X35
B22X70
B22X95
B24X/75
B24X1/5
B24X2/5
B24X10
B27X/75
B27X1/5
B27X2/5
B210X/75
B210X1/5
B210X2/5
B212X/75
B26PX/75
B212X1/5
B212X2/5
B219X/75
B219X1/5
B219X2/5
B227X/75
B227X1/5
B227X2/5
B237X/75
B237X1/5
B237X2/5
B248X/75
B248X1/5
B248X2/5

6/120002
6/120003
6/120004
6/120005
6/120006
6/120007
6/120008
6/120020
6/120024
6/120040
6/120041
6/120042
6/120043
6/120044
6/120045
6/120046
6/120061
6/120062
6/120063
6/120081
6/120082
6/120083
6/120113
6/120084
6/120085
6/120086
6/120087
6/120088
6/120089
6/120090
6/120091
6/120092
6/120093
6/120094
6/120095
6/120096
6/120111
6/120097
6/120098
6/120099
6/120100
6/120101
6/120102
6/120103
6/120104
6/120105
6/120106
6/120107
6/120108
6/120109
6/120110

Temperature limits:
-25 to +85C.
*Bending radius:

RAIL
TYPE

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND


SIZE
CORES (KG/KM) DIAMETER SIZE
(MM2)
A1 Brown
0.75
7/0.37
1
16
2.95
N/A
A1 Red
0.75
7/0.37
1
16
2.95
N/A
A1 Orange
0.75
7/0.37
1
16
2.95
N/A
A1 Grey
0.75
7/0.37
1
16
2.95
N/A
A1 Violet
0.75
7/0.37
1
16
2.95
N/A
A1 Black
0.75
7/0.37
1
16
2.95
N/A
A1 Black
1.15 16/0.30
1
20
3.25
N/A
A2
0.75
7/0.37
1
30
4.50
N/A
A2
1.15 16/0.30
1
35
4.80
20/16
A3
0.75
7/0.37
2
67
7.75
20/16
A3
0.75
7/0.37
4
108
9.20
20S
A3
0.75
7/0.37
6
160
11.10
20S
A3
0.75
7/0.37
10
259
14.35
25
A3
0.75
7/0.37
14
495
15.75
25
A3
0.75
7/0.37
36
752
24.20
32
A3
0.75
7/0.37
48
963
27.50
40
B1
2.5
7/0.67
1
34
8.05
20/16
B1
10
7/1.35
1
205
10.60
20S
B1
35
19/1.53
1
495
14.50
25
B2
1.5
7/0.53
2
135
10.75
20S
B2
2.5
7/0.67
2
170
11.80
20
B2
10
7/1.35
2
443
16.85
25
B2
16
7/1.70
2
625
18.80
25
B2
35
19/1.53
2
1232
25.05
32
B2
70
19/2.14
2
2043
64.80
75
B2
95
19/2.52
2
2945
74.70
90
B2
0.75
7/0.37
4
150
11.50
20S
B2
1.5
7/0.53
4
220
12.30
20
B2
2.5
7/0.67
4
295
13.35
20
B2
10
7/1.35
4
675
19.0
32
B2
0.75
7/0.37
7
225
13.25
20
B2
1.5
7/0.53
7
370
14.20
25
B2
2.5
7/0.67
7
500
15.50
25
B2
0.75
7/0.37
10
280
16.20
25
B2
1.5
7/0.53
10
401
17.50
25
B2
2.5
7/0.67
10
680
19.20
25
B2
0.75
7/0.37
12
321
16.65
25
B2
0.75
7/0.37
6pr
469
22.15
32
B2
1.5
7/0.53
12
410
18.00
25
B2
2.5
7/0.67
12
730
19.80
25
B2
0.75
7/0.37
19
425
19.15
25
B2
1.5
7/0.53
19
615
20.80
32
B2
2.5
7/0.67
19
815
22.95
32
B2
0.75
7/0.37
27
606
22.60
32
B2
1.5
7/0.53
27
897
25.00
32
B2
2.5
7/0.67
27
1200
27.65
40
B2
0.75
7/0.37
37
786
22.60
32
B2
1.5
7/0.53
37
1126
28.25
40
B2
2.5
7/0.67
37
1600
31.25
40
B2
0.75
7/0.37
48
972
28.95
40
B2
1.5
7/0.53
48
1280
31.60
40
B2
2.5
7/0.67
48
1960
35.10
50S

Core identification:
Black with white numbers.

8 x overall diameter.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

117

Stranded or flexible tinned copper conductors to BS6360, EPR insulated to


BS7655-3.2. Heavy duty PCP RS2 sheath for types C1 + C2, LSZH sheath for
types D1, D2, E1+E2. Manufactured to Network Rail specification
NR/PS/SIG/00005 (formerly RT/E/PS/00005).
CCC
CODE

RAIL
CODE

RAIL
TYPE

C11X2/5
C22X2/5
C24X2/5
C27X2/5
C210X2/5
C212X2/5
C216X2/5
D11X/75
D11X1/5
D11X2/5
D11X10
D11X35
D22X1/5
D22X2/5
D22X10
D22X16
D22X35
D24X1/5
D27X1/5
D210X1/5
D212X1/5
D219X1/5
D227X/75
D227X1/5
D227X2/5
D237X/75
D237X1/5
D237X2/5
D248X/75
D248X1/5
D248X2/5
E11X2/5
E22X2/5
E24X2/5
E27X2/5
E210X2/5
E212X2/5

6/120130
6/120140
6/120141
6/120142
6/120143
6/120144
6/120145
6/120211
6/120212
6/120213
6/120214
6/120215
6/120216
6/120217
6/120218
6/1220226
6/120219
6/120223
6/120228
6/120231
6/120234
6/120237
6/120238
6/120239
6/120240
6/120241
6/120242
6/120243
6/120244
6/120245
6/120246
6/120172
6/120170
6/120171
6/120173
6/120174
6/120175

C1
C2
C2
C2
C2
C2
C2
D1
D1
D1
D1
D1
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
E1
E2
E2
E2
E2
E2

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND


SIZE
CORES (KG/KM) DIAMETER SIZE
(MM2)
2.5
50/0.25
1
174
12.60
25
2.5
50/0.25
2
342
16.85
25
2.5
50/0.25
4
445
18.65
25
2.5
50/0.25
7
590
42.40
50
2.5
50/0.25
10
784
25.55
40
2.5
50/0.25
12
868
26.25
40
2.5
50/0.25
16
980
28.65
40
0.75
7/0.37
1
25
7.30
20/16
1.5
7/0.53
1
30
7.65
20/16
2.5
7/0.67
1
34
8.05
20/16
10
7/1.35
1
205
10.60
20S
35
19/1.53
1
495
14.50
25
1.5
7/0.53
2
135
10.75
20S
2.5
7/0.67
2
170
11.80
20
10
7/1.35
2
443
16.85
25
16
7/1.70
2
625.0
20.9
32
35
19/1.53
2
1232
25.05
40
1.5
7/0.53
4
200.0
13.2
25
1.5
7/0.53
7
370.0
15.8
25
1.5
7/0.53
10
401.0
19.4
32
1.5
7/0.53
12
410.0
17.3
32
1.5
7/0.53
19
615.0
23.1
32
0.75
7/0.37
27
606
22.60
32
1.5
7/0.53
27
897
25.00
32
2.5
7/0.67
27
1200
27.65
40
0.75
7/0.37
37
786
25.55
32
1.5
7/0.53
37
1126
28.25
40
2.5
7/0.67
37
1600
31.25
40
0.75
7/0.37
48
972
28.95
40
1.5
7/0.53
48
1280
31.60
40
2.5
7/0.67
48
1960
35.10
50S
2.5
50/0.25
1
174
12.60
20
2.5
50/0.25
2
342
16.85
25
2.5
50/0.25
4
445
18.65
25
2.5
50/0.25
7
590
21.20
32
2.5
50/0.25
10
784
25.55
32
2.5
50/0.25
12
868
26.25
40

Temperature limits:
-25 to +85C.
*Bending radius:
8 x overall diameter.
Core identification:
Black with white numbers.

RAILWAY CABLES
SIGNALING
(0.75MM2 - 35MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

RAILWAY CABLES

RAILWAY SIGNALLING CABLES

RAILWAY CABLES

118

RAILWAY TRAIN PROTECTION WARNING CABLES


Flexible tinned copper conductors to BS6360, EPR insulated to BS7655-2.3,
separate drain wire,single aluminium tape screen (polyester backed). Black
Heavy duty PCP RS2 sheath to BS7655 for type C3, LSZH sheath for type E3.
Manufactured to Network Rail specification NR/PS/SIG/OOOO5 (formerly
RT/E/PS/00005).
CCC
CODE

RAIL
CODE

RAIL
TYPE

C3TPWS
E3TPWS

6/160086
6/160090

C3TPWS
E3TPWS

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND

SIZE
(MM)
2.5
2.5

CORES (KG/KM) DIAMETER


50/0.25
50/0.25

1PR
1PR

250
250

17.50
17.50

SIZE
25
25

Temperature limits:
-25 to +85C.
*Bending radius:
8 x overall diameter.

RAILWAY CABLES
TRAIN PROTECTION WARNING
POINT HEATER

RAILWAY POINT HEATER CABLES


Flexible tinned copper conductor to B6360, EPR insulation type GP4 to BS7655, black
PCP type EM2 sheath to BS7655. Manufactured to Network Rail specification
NR/SP/ELP/40045 (formerly R/E/PS/40045).
CCC
CODE

RAIL
CODE

3184PH1/5
3188PH1/5
3188PH2/5
6388PH4
6388PH6
6388PH10
6388PH16

6/150002
6/153002
6/153103
-

CONDUCTOR
SIZE
(MM2)
1.5
1.5
2.5
4.0
6.0
10.0
16.0

STRANDING

NO. OF
CORES

30/0.25
30/0.25
50/0.25
56/0.30
84/0.30
75/0.40
118/0.40

4
8
8
8
8
8
8

WEIGHT OVERALL
(KG/KM) DIAMETER
220
460
510
830
1040
1799
2480

14.32
18.44
23.36
23.60
25.60
31.70
36.20

GLAND
SIZE
25
25
32
32
32
40
50S

Temperature limits:
-30 to +70C.
Core identification:
4 core - Yellow, Yellow, Blue, Blue.
8 core - Yellow, Yellow, Blue, Blue,
Brown, Brown, Black, Black.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

119

Solid plain annealed copper conductors, polyethylene insulation, petroleum


jelly filled, polyethylene outer sheath. Manufactured to Network Rail
specification RT/E/PS/0031.
CCC
CODE

RAIL
CODE

F1D0902
F1D0910
F1D0912
F1D0919
F1D0924
F1D1402
F1D1410
F1D1412
F1D1419
F1D1424

6/170001
6/170002
6/170003
6/170004
6/170005
6/170121
6/170122
6/170123
6/170124
6/170125

CONDUCTOR STRANDING
SIZE
(MM2)
0.63
1/0.9
0.63
1/0.9
0.63
1/0.9
0.63
1/0.9
0.63
1/0.9
1.5
1/1.4
1.5
1/1.4
1.5
1/1.4
1.5
1/1.4
1.5
1/1.4

NO. OF
PAIRS
2
10
12
19
24
2
10
12
19
24

WEIGHT OVERALL
(KG/KM) DIAMETER
165
526
633
1034
1326
318
1020
1691
1691
2419

13.20
21.60
24.80
31.20
33.80
23.40
30.00
32.00
37.30
42.30

GLAND
SIZE
25
32
32
40
50S
32
40
50S
50S
50S

Core identification:

RAILWAY CABLES
AXLE COUNTING CABLES
AND DATALINK

PAIR NO
1
2
3
4
5
6
7
8
9
10
11
12

A WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
YELLOW
YELLOW

B WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE

PAIR NO
13
14
15
16
17
18
19
20
21
22
23
24

A WIRE
YELLOW
YELLOW
YELLOW
VIOLET
VIOLET
VIOLET
VIOLET
VIOLET
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE

B WIRE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN

Two pair cables laid up in quad formation colour coded in rotation, Orange,
White, Green, Black.
Temperature limits:
-40 to +70C.
*Bending radius:
15 x overall diameter

RAILWAY DATALINK CABLE


Solid copper conductor, polythylene insulation, aluminium/polyethylene laminated
moisture barrier, polyethylene sheath black or blue. To BR1932.
CCC
CODE

RAIL
CODE

STRANDING

NO. OF
CORES

DATALINK2X1/27
DATALINK2X1/27BU
DATALINK2X1/27LSF

6/166065
6/166065
6/166065

1/1.27
1/1.27
1/1.27

2
2
2

Temperature limits:
PE sheath -40 to + 70C
LSZH sheath -10 to + 50C

WEIGHT OVERALL
(KG/KM) DIAMETER
136
136
136

12.47
12.47
12.47

GLAND
SIZE
25
25
25

*Bending radius:
15 x overall diameter
Core identification:
Blue, Red.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

RAILWAY CABLES

RAILWAY AXLE COUNTING CABLES

RAILWAY CABLES

120

RAILWAY AXLE COUNTING CABLE NON ARMOURED


Solid tinned annealed copper conductors, polyethylene insulation (type 03 to
BS6234), petroleum jelly filled (XPS and XQS types only), glass fibre weave,
aluminium/polymer laminate tape, polyetheylene sheath XPS type (type 03C
to BS6234) or LSZH XPZ type. Manufactured to Network Rail specification
RT/E/PS/0031. Spec AzLM axle counter cable NRL2SIG30060.
CCC
CODE

RAIL
CODE

CABLE
TYPE

XPS0902
XPS0910
XPS0912
XPS0919
XPS0924
XPS1402
XPS1410
XPS1412
XPS1419
XPS1424
XPZ0902
XPZ0910
XPZ0912
XPZ0919
XPZ0924
XPZ1402
XPZ1410
XPZ1412
XPZ1419
XPZ1419

006/170007
006/170008
006/170009
006/170034
006/170035
006/170036
006/170037
006/170038
006/170039
006/170040
006/170023
006/170024
006/170025
006/170026
006/170027
006/170028
006/170029
006/170030
006/170031
006/170032

XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ

CONDUCTOR STANDING NO. OF


SIZE (MM)
PAIRS
0.63
0.63
0.63
0.63
0.63
1.5
1.5
1.5
1.5
1.5
0.63
0.63
0.63
0.63
0.63
1.5
1.5
1.5
1.5
1.5

1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/1.4
1/1.4
1/1.4
1/1.4
1/1.4
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/1.4
1/1.4
1/1.4
1/1.4
1/1.4

WEIGHT OVERALL
(KG/KM) DIAMETER

2
10
12
19
24
2
10
12
19
24
2
10
12
19
24
2
10
12
19
24

215
530
584
810
982
320
910
1016
1460
1787
200
424
468
632
746
314
807
909
1284
1548

13.8
24.7
26.4
31.4
34.5
16.4
31.4
33.8
40.8
45.0
13.8
24.7
26.4
31.4
34.5
16.4
31.4
33.8
40.8
45.0

Temperature limits:
- 25 to + 85C
*Bending radius:
7.5 x overall diameter
Core identification:
Table 6 core colours:
Table 7 layer make-up:

RAILWAY AXLE COUNTING


CABLE NON ARMOURED

PAIR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

CORE COLOURS
White
White
White
White
White
Red
Red
Red
Red
Red
Yellow
Yellow
Yellow
Yellow
Yellow
Violet
Violet
Violet
Violet
Violet
Turquoise
Turquoise
Turquoise
Turquoise

Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown

NO. OF PAIRS
2
10
12
19
24

PAIR NOS. IN EACH LAYER


CENTRE
1ST LAYER
1&2
1&2
3 -> 10
1 -> 3
4 -> 12
1
2 -> 7
1&2
3 -> 10

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

121

Solid plain annealed copper conductors to BS6360, polytheylene insulation,


petroleum jelly filled, corrugated steel armour, polytheylene outer sheath.
Manufactured to Network Rail specification NR/PS/TEL/00015 (formerly
RT/E/PS/00015).
CCC
CODE

RAIL
CODE

13781
13784
13786
13788
13790

6/168061
6/168063
6/168064
6/168065
6/168066

CONDUCTOR STRANDING
SIZE
(MM2)
0.63
1/0.9
0.63
1/0.9
0.63
1/0.9
0.63
1/0.9
0.63
1/0.9

Temperature limits:
-25 to +85C.
Core identification:
2 PAIR (laid up in quad formation)
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10

A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED

NO. OF
PAIRS
2
10
20
30
50

WEIGHT OVERALL
(KG/KM) DIAMETER
250
520
820
915
1550

19.00
23.80
27.60
30.9
35.70

GLAND
SIZE
20
25
32
32
32

Bending radius:
10 x overall
diameter.

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

20 PAIR (laid up in 4x5 pair)


PAIR
NUMBER
1
2
3
4
5

SUB-UNIT (CODE A)
A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY

PAIR
NUMBER
1
2
3
4
5

SUB-UNIT (CODE B)
A
WIRE
RED
RED
RED
RED
RED

B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY

Each unit is lapped with coloured tape for identification as follows:


UNIT
NUMBER
1
2
3
4

UNIT
CODE
A
B
C
D

COLOUR OF
BINDINGS
BLUE
BLUE
ORANGE
ORANGE

30 PAIR (laid up in 3x10 pair)


50 PAIR (laid up in 5x10 pair)
PAIR
NUMBER
1
2
3
4
5
6
7
8
9
10

COPPER TRACKSIDE CABLE

SUB-UNIT (CODE A)
A
WIRE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED

Each unit is lapped with coloured


tape for identification as follows:
B
WIRE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY

UNIT
NUMBER
1
2
3
4
5

COLOUR OF BINDINGS
BLUE
ORANGE
GREEN
BROWN
GREY

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

RAILWAY CABLES

RAILWAY COPPER TRACKSIDE COMMUNICATION CABLES

RAILWAY CABLES

122

RAILWAY POWER AND TRACK FEEDER CABLES


POWER CABLES
Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath,
Black to BR880 06/142639. 600/1000 volts grade to BS 5467.
CCC
CODE

RAIL
CODE

SAC2X16NA
SAC2X25NA
SAC2X35NA
SAC2X50NA
SAC2X70NA
SAC2X95NA
SAC4X70NA

6/142419
6/142519
6/142609
6/142629
6/142639
6/142644
6/151469

CONDUCTOR
SIZE
(MM2)
16
25
35
50
70
95
70

Temperature limits:
+90C.
*Bending radius:

NO. OF
CORES

WEIGHT
(KG/KM)

OVERALL
DIAMETER

GLAND
SIZE

2
2
2
2
2
2
4

420
455
525
620
840
1020
1750

14.30
16.60
18.00
20.40
22.80
26.20
30.60

25
25
25
32
32
40
40

Core identification:
2 core - Brown, Blue.
4 core - Blue, Brown, Black, Grey.

8 x overall diameter.

RAILWAY CABLES
POWER &
TRACK FEEDER

TRACK FEEDER CABLES


Uncompacted circular stranded aluminium to BS6360 or uncompacted circular
stranded tinned copper to BS6360. CSP sheathed type RS4 to BS6899, black.
Manufactured to Network Rail specification NR/PS/ELP/21101 (formerly
RT/E/S/21101).
CCC
CODE

RAIL
CODE

POLARITY

TRACK150
TRACK161
TRACK240
TRACK500
TRACK500CU
TRACK630CU
TRACK800
TRACK1000
TRACK240LSF
TRACK800LSF
TRACK1000LSF

6/116601
6/132340
6/132990
6/132840
6/132992
6/116612
6/132991
6/116610
-

NEGATIVE
NEGATIVE
NEGATIVE
POSITIVE
NEGATIVE
POSITIVE
NEGATIVE
POSITIVE
NEGATIVE
NEGATIVE
POSITIVE

CONDUCTOR STRANDING NO. OF WEIGHT OVERALL GLAND


SIZE
CORES (KG/KM) DIAMETER SIZE
(MM2)
150 AL 37/2.25
1
540
19.40
25
161 CU 91/1.53
1
1887
24.80
32
240 AL 61/2.25
1
1076
28.30
40
500 AL 61/3.20
1
2245
40.20
50
500 CU 91/2.65
1
5291
40.60
50
630 CU 127/2.52
1
6692
44.20
63S
800 AL 127/2.85
1
3255
48.50
63S
1000 AL 127/3.20
1
3943
53.00
63
240 AL 61/2.25
1
1076
28.3
40
800 AL 127/2.85
1
3255
48.5
63S
1000 AL 127/3.2
1
3943
53.0
63

Temperature limits:
-25C to +85C.
*Bending radius:
Aluminium conductor - 10x overall
diameter
Copper conductor - 8x overall
diameter

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

123

MARINE AND OFFSHORE CABLES

MARINE AND
OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

124

MARINE AND OFFSHORE CABLES


Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)
insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts
grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2.
CCC
CODE
6571TQ1/5
6572TQ1/5
6573TQ1/5
6574TQ1/5
6575TQ1/5
6576TQ1/5
6577TQ1/5
6578TQ1/5
6570/10TQ1/5
6570/12TQ1/5
6570/19TQ1/5
6570/27TQ1/5
6570/30TQ1/5
6570/37TQ1/5
6571TQ2/5
6572TQ2/5
6573TQ2/5
6574TQ2/5
6575TQ2/5
6576TQ2/5
6577TQ2/5
6578TQ2/5
6570/10TQ2/5
6570/12TQ2/5
6570/19TQ2/5
6570/27TQ2/5
6570/30TQ2/5
6570/37TQ2/5
6571TQ4
6572TQ4
6573TQ4
6574TQ4
6575TQ4
6577TQ4
6571TQ6
6572TQ6
6573TQ6
6574TQ6

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
5
6
7
8
10
12
19
27
30
37
1
2
3
4
5
6
7
8
10
12
19
27
30
37
1
2
3
4
5
7
1
2
3
4

49
125
150
180
190
240
275
295
360
440
740
970
1015
1220
63
160
190
240
280
470
355
398
519
650
860
1220
1270
1610
90
240
280
360
425
530
115
305
370
475

OVERALL
DIAMETER
(MM)
5.5
8.9
9.4
10.3
11.0
12.2
12.5
13.3
16.2
16.4
19.3
23.5
24.3
26.0
6.0
9.8
10.4
11.4
12.6
16.9
13.7
15.3
17.7
18.3
21.7
26.3
27.1
29.5
6.9
12.0
12.7
13.9
15.3
17.7
7.5
13.1
13.9
15.4

UKOOA
CODE
WF102
WF202
WF302
WF402
WF502
WF702
WFA02
WFB02
WFC02
WFD02
WF103
WF203
WF303
WF403
WF503
WF703
WFA03
WFB03
WFC03
WFD03
WF104
WF204
WF304
WF404
WF504
WF704
WF106
WF206
WF306
WF406

Core identification:
White with Black numbers.
Single cores available in either Black
or Green/Yellow outer sheath.
Should not be installed at
temperatures below -15C.

EPR INSULATED
NON-ARMOURED
SHIPWIRING CABLE
(1.5MM2 TO 6MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

125

Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)


insulated, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts
grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2.
CCC
CODE
6571TQ10
6572TQ10
6573TQ10
6574TQ10
6571TQ16
6572TQ16
6573TQ16
6574TQ16
6571TQ25
6572TQ25
6573TQ25
6574TQ25
6571TQ35
6572TQ35
6573TQ35
6574TQ35
6571TQ50
6572TQ50
6573TQ50
6574TQ50
6571TQ70
6573TQ70
6574TQ70
6571TQ95
6573TQ95
6574TQ95
6571TQ120
6573TQ120
6571TQ150
6571TQ185
6571TQ240
6571TQ300
6571TQ400
6571TQ500
6571TQ630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
10
10
10
10
16
16
16
16
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
95
95
95
120
120
150
185
240
300
400
500
630

7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
19/1.35
19/1.35
19/1.35
19/1.35
19/1.53
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
37/1.78
37/1.78
37/1.78
37/2.03
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52

NO. OF
CORES

WEIGHT
KG/KM

1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
3
4
1
3
4
1
3
1
1
1
1
1
1
1

165
470
595
745
230
655
830
1045
380
1090
1340
1680
490
1310
1630
2130
640
1720
2210
2840
870
3080
3950
1150
4060
5170
1440
5130
1770
2200
2780
3450
4400
5600
6910

OVERALL
DIAMETER
(MM)
9.0
16.0
17.2
18.9
10.1
18.3
19.5
21.7
12.4
22.9
24.4
27.1
13.6
25.3
27.1
30.1
15.5
29.0
30.9
34.6
17.5
35.3
39.2
19.6
40.3
45.1
21.4
44.4
23.8
26.3
29.5
32.6
36.7
40.5
44.4

UKOOA
CODE
WF110
WF210
WF310
WF410
WF116
WF216
WF316
WF416
WF125
WF225
WF325
WF425
WF135
WF235
WF335
WF435
WF150
WF250
WF350
WF450
WF170
WF370
WF470
WF195
WF395
WF495
WF10A
WF30A
WF10B
WF10C
WF10D
WF10E
WF10F
WF10G
WF10H

Single core cables are available in


Black or Green/Yellow outer sheath.
Temperature limits:
-30 to +85C.
*Bending radius:
up to 25mm - 4 x overall diameter.
above 25mm - 6 x overall diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15C.

EPR INSULATED
NON-ARMOURED
SHIPWIRING CABLE
(10MM2 TO 630MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

126

MARINE AND OFFSHORE CABLES


Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)
insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid
armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black. 600/1000 volts
grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61304-1,2.
CCC
CODE
6582TQ1/5
6583TQ1/5
6584TQ1/5
6585TQ1/5
6586TQ1/5
6587TQ1/5
6580/12TQ1/5
6580/19TQ1/5
6580/27TQ1/5
6580/37TQ1/5
6582TQ2/5
6583TQ2/5
6584TQ2/5
6585TQ2/5
6586TQ2/5
6587TQ2/5
6580/12TQ2/5
6580/19TQ2/5
6580/27TQ2/5
6580/37TQ2/5
6582TQ4
6583TQ4
6584TQ4
6585TQ4
6587TQ4

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0

7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
5
6
7
12
19
27
37
2
3
4
5
6
7
12
19
27
37
2
3
4
5
7

300
325
395
407
425
525
790
1090
1515
1870
350
400
470
485
550
635
990
1390
1990
2500
480
530
585
700
897

OVERALL
DIAMETER
(MM)
13.3
13.8
15.0
15.2
16.5
17.2
21.7
24.7
29.3
33.2
14.2
15.0
16.1
16.9
18.2
18.5
23.9
27.6
33.2
36.7
16.6
17.3
18.4
20.2
22.7

UKOOA
CODE
WB202
WB302
WB402
WB702
WBA02
WBB02
WBC02
WBD02
WB203
WB303
WB403
WB503
WB703
WBA03
WBB03
WBC03
WBD03
WB204
WB304
WB404
WB504
WB704

Temperature limits:
-30 to +85C.
*Bending radius:
6 x overall diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15C.

EPR INSULATED
BRAIDED ARMOUR
SHIPWIRING CABLE
(1.5MM2 TO 4MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

127

Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)


insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire braid
armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts
grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61304-1,2.
CCC
CODE
6582TQ6
6583TQ6
6584TQ6
6582TQ10
6583TQ10
6584TQ10
6582TQ16
6583TQ16
6584TQ16
6582TQ25
6583TQ25
6584TQ25
6582TQ35
6583TQ35
6584TQ35
6582TQ50
6583TQ50
6584TQ50
6582TQ70
6583TQ70
6584TQ70
6582TQ95
6583TQ95
6584TQ95
6582TQ120
6583TQ120
6584TQ120
6582TQ150
6583TQ150
6584TQ150
6583TQ185
6584TQ185
6583TQ240
6584TQ240
6583TQ300
6584TQ300

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
6
6
6
10
10
10
16
16
16
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
240
240
300
300

7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
19/1.35
19/1.35
19/1.35
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
37/1.78
37/1.78
37/1.78
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
61/2.25
61/2.25
61/2.52
61/2.52

NO. OF
CORES

WEIGHT
KG/KM

2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
3
4
3
4

570
635
760
750
930
1080
1020
1190
1450
1500
1800
2500
1810
2400
2880
2510
3000
3670
2940
3980
4840
3813
5290
6310
4692
6480
7770
5634
7700
9400
9550
11520
12300
14840
14850
17938

OVERALL
DIAMETER
(MM)
17.9
18.7
20.1
21.0
22.4
24.0
23.7
24.9
26.9
29.0
30.7
33.6
31.0
34.0
36.2
36.0
38.1
41.0
36.0
42.8
46.1
40.9
48.5
52.6
44.9
52.9
57.4
48.9
57.9
63.1
63.8
69.6
71.5
78.3
78.8
84.9

UKOOA
CODE
WB206
WB306
WB406
WB210
WB310
WB410
WB216
WB316
WB416
WB225
WB325
WB425
WB235
WB335
WB435
WB250
WB350
WB450
WB270
WB370
WB470
WB295
WB395
WB495
WB20A
WB30A
WB40A
WB20B
WB30B
WB40B
WB30C
WB40C
WB30D
WB40D
WB30E
WB40E

Temperature limits:
-30 TO +85C.
*Bending radius:
6 x overall diameter
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15C.

EPR INSULATED
BRAIDED ARMOURED
SHIPWIRING CABLE
(6MM2 TO 300MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES

128

MARINE AND OFFSHORE CABLES


Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR)
insulated, low smoke, zero halogen (LSZH) bedding tinned phosphor bronze
braid armour, low smoke, zero halogen (LSZH) SW4 outer sheath. Black.
600/1000 volts grade to IEC90092-353, IEC60331-21, IEC60332-2, IEC60332-222, IEC60751-2,2 and IEC61034-1,2.
CCC
CODE
6591TQ6
6591TQ10
6591TQ16
6591TQ25
6591TQ35
6591TQ50
6591TQ70
6591TQ95
6591TQ120
6591TQ150
6591TQ185
6591TQ240
6591TQ300
6591TQ400
6591TQ500
6591TQ630

CONDUCTOR STRANDING
SIZE (MM2)
(MM)
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52

NO. OF
CORES

WEIGHT
KG/KM

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

245
320
395
565
740
940
1270
1600
1930
2330
3000
3710
4480
5340
6540
8000

OVERALL
DIAMETER
(MM)
11.7
13.4
14.5
17.3
18.4
20.3
22.7
25.0
27.2
29.5
33.1
36.6
40.0
43.9
48.1
52.3

UKOOA
CODE
WAB06
WAB10
WAB16
WAB25
WAB35
WAB50
WAB70
WAB95
WABOA
WABOB
WABOC
WABOD
WABOE
WABOF
WABOG
WABOH

Temperature limits:
-30 to +85C.
*Bending radius:
6 x overall diameter.
Core identification:
White.
Should not be installed at
temperatures below -15C.

EPR INSULATED SINGLE


CORE BRAIDED
SHIPWIRING CABLE
(6MM2 TO 630MM2)

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of
the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their
own judgement and experience of the capabilities of their cable, it is not a specification defined in standards.

129

INSTALLATION ACCESSORIES

INSTALLATION
ACCESSORIES

131

LML

LML Products Limited


Since its inception in 1968, LML has designed, manufactured and supplied a
comprehensive range of copper tube terminals including bespoke specials.
With in-house tooling and electroplating facilities, LML will always provide a
solution for its quality focused customers in compliance with BS EN ISO
9001:2000
Copper Tube Terminals
LML terminals are manufactured from seamless copper tube to BS EN 12449
and feature bell mouth entry up to 400mm2 and chamfered entry from
500mm2 to 1000mm2. All terminals and splices (other than parallel splices) are
provided with an inspection hole to ensure the conductor is fully inserted
before crimping. Internal barrel diameters suit standard cables as defined in
BS EN 6360.
Standard finish is bright electro tin plating to BS EN 1872. Other finishes can
be provided, e.g. nickel or silver. Terminals are independently tested to comply
with BS EN 61238-1, and are also approved for military use and by London
Underground.
Crimp Tooling
LML Products also supply a large range of manual hydraulic tools for crimping
terminals from 1.5mm2 to 1000mm2. LML also supplies a range of hydraulic
crimping tools with rechargeable battery.
Med/High Voltage Crimp Terminals
LML Products manufactures a range of copper tube terminals to suit 11kv and
33kv. We also manufacture water blocked splices and terminals.

www.

cmp-products

.com

SERVICES
AND SUPPORT
FROM CMP PRODUCTS

CMP
CMP PRODUCTS

CMP Products offers a comprehensive training program for the


installation of it's products. Whether you just need a video to show
you how it's done, require practical demonstrations at your
premises or indeed you require training on site for large groups,
CMP is able to assist. We offer certified training on all of our
products with all attendees receiving a training certificate following
successful completion of the course to demonstrate competence.

CERTIFIED TRAINING
AVAILABLE

for designers/specifiers
for installers
for a QA, QC Personnel
installation video's available for all
products
in multiple languages
for design engineers to assist with
correct product selection
to keep up with the latest standards
wherever you need it, when you
need it

ALSO
AVAILABLE
from CMP Products
Breather Drain Plugs
Adaptors & Reducers
Stopper Plugs
Unions
Locknuts
Serrated Washers
Earth Tags
Entry Thread Seals
Shrouds

135

RAXTON LIMITED

Raxton products are designed to solve the fundamental difficulties which


exist due to the variety of thread forms currently in use within the electrical
industry. These thread forms are predominantly Isometric, Imperial, N.P.T., BSP
and PG.
Problems caused by dissimilar threads can occur in many environments
including industrial, EExd, EExe and mining. Raxton conversions are fully
approved to meet these requirements, being certified by leading test
authorities including BASEEFA, SIRA, ISSEP, KEMA, DET NORSKE VERITAS and
Standards Association of Australia. They are marked accordingly.
Standard material is brass and readily available alternatives include mild
steel, stainless steel and aluminium. Our EExe range is also available in glass
filled nylon.
ADAPTORS
REDUCERS
HEXAGON HEAD PLUGS
RIGHT ANGLE ADAPTORS
MALE TO MALE ADAPTORS
UNIONS
STOPPING PLUGS
EARTH LEAD ADAPTORS
THREADED EARTH PLATES

NYLON GLANDS
SCREWED NIPPLING
COUPLERS
BUSHES
SHROUDS
LOCKNUTS/LOCKRINGS
EARTH TAGS
WASHERS

Legrand
cable management
solutions...

LEGRAND
CA B L E M A N AG E M E N T

www.legrand.co.uk

138

W. J. FURSE & COMPANY LIMITED

E-Klips is a division of W J Furse & Co Ltd, a multi-disciplined engineering and


marketing company employing nearly 200 people worldwide.
We are the largest UK manufacturer of a comprehensive range of industrial
fasteners, which are made available to the electrical/mechanical industry.
They provide a quick, efficient method of fixing without drilling or bracket making.
Our commitment to quality has set industry standards while our new designs
bring you all the benefits of E-Klips continuous product development philosophy.
Wholly manufactured in the UK, E-Klips fasteners can be found throughout
Europe and in many other countries in the world where our unequalled
combination of speed and quality is properly appreciated.
This combination can give you savings of up to 60% over a complete
installation a very significant competitive advantage!
E-Klips are available for every type of installation through our established
distributor network who are fully supported by our stocks and service.
So, if you would like to use the faster fastener, simply specify E-Klips and put
your opposition in the shade.

139

W. J. FURSE & COMPANY LIMITED

As a recognised world leader in the Earthing and Lightning Protection Industry,


W J Furse has a proven track record spanning over one hundred years.
The range complies with the requirements of relevant British and World
standards, and our design and manufacturing quality control systems are
independently assessed and approved to ISO9001. W J Furse can also offer a
level of competitiveness, service and technical support that is the envy of
competitors both in the UK and overseas.
Our extensive range includes the following:
Earth Rods
Copperbond, solid copper and stainless steel.
Earth Pits
Lightweight, high performance plastic and regular duty concrete pits.
Fittings
Clamps, bonds, clips and accessories in copper and aluminium alloys and
plastics suitable for flat tape and solid circular conductor systems.
Conductors
An extensive range of copper and aluminium conductors available bare and
PVC covered.
Specialist Products
Including weldable and adhesive conductor clips and earth rod seals.
Furseweld Process
An exothermic welding process with a simple self contained method of
forming high quality electrical connections which do not require external
power or heat source, making the process completely portable.

140

FRAMING AND SUPPORT SYSTEMS

AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL

141

AVAILABLE IN HOT DIP GALVANISED OR STAINLESS STEEL


*These items require a separate M10X40 cone bolt

Tel : 01642 217341 Fax: 01642 253723


em ai l : sales@bilcourt. co. uk

Cables & leads

Cable management

Heating & ventilation

Distribution, switchgear & enclosures


Lamps

Lighting products

Security & emergency

Site equipment. tools & fixings


Wiring accessories

MEMBER

offering a great deal more

Middlesbrough Branch

Milton Keynes Branch

Warrington Branch

Riverside Park Road,


Middlesbrough,
Cleveland TS2 1QW

7 Fitzhamon Court,
Wolverton Mill South,
Milton Keynes MK12 6LB

Tel: Sales 01642 241133 / Admin 254234


Fax: Sales 01642 226171 / Admin
226474

Tel: 01908 221414


Fax: 01908 221661

2 Bishops Court,
Calver Road,
Winwick Quay,
Warrington WA2 8QY

Email: miltonkeynes@clevelandcable.com

Tel: 01925 655383


Fax: 01925 655989
Email: warrington@clevelandcable.com

Email: sales@clevelandcable.com
Website: www.clevelandcable.com
Bristol Branch

London Branch

Bilcourt Electrical Distributors Ltd

St. Georges Industrial Estate,


St. Andrews Road,
Avonmouth,
Bristol BS11 9HS

Crabtree Manorway South,


Belvedere,
Kent DA17 6AB

Riverside Park Road,


Middlesbrough,
Cleveland TS2 1QW

Tel: 0208 311 4141


Fax: 0208 320 5454

Tel: 01642 217341


Fax: 01642 253723

Email: london@clevelandcable.com

Email: sales@bilcourt.co.uk

Glasgow Branch

Newcastle Branch

Aberdeen Office

56 Clydesmill Road,
Cambuslang Investment Park,
Cambuslang,
Glasgow G32 8RE

Fisher Street Industrial Estate,


Walker,
Newcastle Upon Tyne NE6 4LT

Westhill Business Centre,


Arnhall Business Park,
Westhill, Aberdeen AB32 6UF

Tel: 0191 2633363


Fax: 0191 2630601

Tel: Sales 01224 330565


Fax: Sales 01224 330564

Tel: 01179 382222


Fax: 01179 382220
Email: bristol@clevelandcable.com

Tel: 0141 646 5000


Fax: 0141 646 5001
Email: glasgow@clevelandcable.com

Email: newcastle@clevelandcable.com