OLYMPIC CABLE COMPANY SDN. BHD.

11KV SINGLE CORE, CROSS-LINKED POLYETHYLENE (XLPE) INSULATED, COPPER TAPE SCREENED, PE OVERSHEATHED NON-ARMOURED CABLE
REF DESCRIPTION UNIT 630 mm
2
x 1C
1 Reference standard
2 Voltage (Uo / U) kV
3 Number of cores
4 Conductor
- Material Hard Drawn Aluminium Wires
- Cross sectional area mm
2
- Number of strands Nos. Min. 53
- Conductor shape
- Conductor's outermost lay direction Right-handed (Z)
5 Conductor Screen
-Material
6 Insulation
- Material
- Nominal thickness mm
7 Insulation Screen
-Material
-Nominal thickness mm
-Diameter over insulation screen (Approx.) mm
8 Metallic Screen
-Material
-Nominal thickness mm
9 Outer Sheath
- Material
- Nominal thickness mm
10 Condition Upon Which Current Carrying
Capacities are Based
- Soil thermal resistivity K-m/w
- Ground temperature
o
C
- Ambient air temperature
o
C
- Burial depth mm
- Type of duct material
- Type of earth bonding-Trefoil
- Load factor %
- Number of circuit
11 Minimum Radius of Bend
- Laid direct in ground mm
- Laid in duct mm
- Laid in air mm
12 Minimum interal diameter of duct mm
13 Maximum DC Resistance of Conductor at 20
0
C ohm/km
14 Maximum Conductor Temperature
- Laid direct in ground
0
C
- Drawn into duct
0
C
- Laid in air
0
C
IEC 60502-2:1998
Copper Tape
Black MDPE
2.3
3.40
0.60
Semi-conducting compound
6.35 / 11
1
630
Semi-conducting compound
TECHNICAL DATA
800
25
40
1.2
90
90
90
0.0469
Bonding at both ends
510
100
510
67
510
PVC
1
37.70
Compacted circular
Cross-linked Polyethylene
0.08
Page 1 of 2
OLYMPIC CABLE COMPANY SDN. BHD.
11KV SINGLE CORE, CROSS-LINKED POLYETHYLENE (XLPE) INSULATED, COPPER TAPE SCREENED, PE OVERSHEATHED NON-ARMOURED CABLE
REF DESCRIPTION UNIT 630 mm
2
x 1C
15 Maximum Current Carrying Capacity Based
on condition Specified (See Ref : 14)
- Laid in ground Amp
- Drawn into duct Amp
- Laid in air Amp
16 Conductor Short Time Current Rating
-Initial temperature
0
C
-Maximum conductor short time temperature
0
C
Short circuit current rating:-
-For 1 second kA
-For 3 second kA
17 Copper Tape Earth Fault Current Rating
- Initial temperature
0
C
- Maximum conductor fault teperature
0
C
- Short circuit current rating:-
- For 1 second (individual core) kA
- For 3 second (individual core) kA
18 Maximum Volt Drop at Maximum Conductor
Temperature
- For 1 - phase circuits mV/A.m
- For 3 - phase circuits mV/A.m
DiscIuimer
0.18
0.92
0.53
80
200
-
TECHNICAL DATA
34.38
90
592
783
250
59.55
632
Producf specificofions, fechnicoI dofo & ofher informofion ore for reference onIy. They moy chonge from fime fo
fime wifh odvonces in reseorch & fieId experience. The compony reserves fhe righf fo moke such chonges of ony
fime wifhouf prior nofice.
Page 2 of 2