AT V400kVA

Volvo 400kVA Technical Data

Model Stand By Power @ 50Hz Prime Power @ 50Hz

AT V400kVA 352kW/440kVA 320kW/400kVA

Key Features
Engine (Volvo, TAD1242GE) Charge alternator 24V Governor: Elec Alternator (Marelli MJB315MA) Single bearing alternator IP 23, insulation class H Radiator 50 C (122 F) max, air inlet with coolant cap Skid and vibration isolators Dry type air filter Main line circuit breaker Microprocessor control panel 24V battery, rack and cable Industrial silencer (loose) User manual Factory Test Certificate

AT V400kVA

Generator Ratings
Voltage Hz Phase Power Factor
0.8 0.8

Standby Amps
660 660

Standby Ratings kW/kVA


352/440 352/440

Prime Ratings kW/kVA


320/400 320/400

415/240 400/230

50 50

3 3

RRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. A 10% overload capability is available for a period of 1 hour within 12 hour period of operation, in accordance with ISO 3046-1. ESP: The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed.

Dimensions & Weights Openset Length (L) mm Width (W) mm Height (H) mm Weight (kg) Fuel Tank (lt) 3500 1100 1735 3537 482 Enclosure 4519 1687 2400 4482 705

AT V400kVA

Engine Data
Manufacturer/Model No of Cylinder / Configuration Displacement Bore and stoke Compression ratio Rated RPM Governor: type Engine Gross Power Aspiration Volvo, TAD1242GE 6 INLINE 12.13L 131 mm x 150 mm 17.5:1 1500 Rpm Electronic 398kWm Turbocharged and Intercooled

Exhaust System
Exhaust gas flow Exhaust temperature 69 m/min 525C

Fuel Consumption
100% 75% 50% 75.4 L/h 57.4 L/h 81.9 L/h

Oil System
Lubrication oil capacity 31L

Air intake
Combustion Air Flow Cooling Air flow 26 m/min 216 m/min

Coolant System
Coolant Capacity Cooling System 24L Water

Alternator Specifications
Manufacturer/Type Number of Phase Power Factor Pole: Number No of Bearing Insulation Class Voltage Regulation Excitation System No of Leads Degree of Protection Total Harmonic Content (No Load) Voltage Output Efficiency Marelli MJB315MA 3 0.8 4 Single H +/- 0.5% AVR (Automatic Voltage Regulator), Brushless 12 IP 23 <2% 230 / 400 VAC 93.7%

AT V400kVA

Control System
The control system used for this model is based the Deep Sea Electronics DSE7210 Digital Auto Start controller. This provides for the manual and automatic remote start of the generator and contains following features: Real time clock for improved event and performance monitoring 132 x 64 pixel LCD Display Multiple date and time maintenance scheduler Five key menu navigation Operated via Start, Stop, Auto and Manual soft touch membrane buttons on the front panel Coolant temperature with high temperature alarm and shutdown Coolant temperature low warning Oil pressure with low pressure alarm and shutdown Oil temperature, engine operating hours, battery charge volts and amps Volts, with Under/Over Volts protection Amps, with Over Current protection Frequency, kW, kVA, Power Factor Automatic cool-down timer function

Acoustic Enclosure
The acoustic enclosure is suitable for operation in harsh outdoor environments whilst providing excellent security and acoustic performance. The steel canopy and baseframe is of fully welded construction with a two-pack polyurethane egg-shell finish in RAL9001 white. Acoustically, the canopy is designed to meet the requirements of EU Legislation 2000/14/EC, achieved by extensive use of rock wool and perforated zintec steel lining, together with efficient management of cooling air. Exhaust noise is minimized by a unique high performance exhaust silencer, mounted within the baseframe. A steel bunded fuel tank is situated inside the baseframe to allow 8 hours running of the generator at 75% load. Also integrated within the baseframe are filler, gauge and accessory points. Other key features include: Lifting and holding down points on baseframe 4 no. eye lifting hooks Emergency Stop button relocated to canopy exterior External service access panels Heavy duty locks on all doors for total security Weather cap on exhaust discharge Side-opening doors with retainers for good service access

AT V400kVA

Key Mechanical Options Available:


Engine and Radiator
Heat shield protection Oil Drain extension Heavy Duty oil filter Lube oil drain pump Radiator core guard Battery charger Block header

Control Panel
Paralleling system Remote annunciator Co-map / Deepsea Key start panel

Alternator
Anti condensation heater Enforced impregnation Oversized alternator

Exhaust
Residential silencer Flexible exhaust connection

Enclosure
M227 85dba @ 1m silent canopy Special Colour

Fuel
24 hour day tank Bulk fuel tank connections Water separator fuel filter

* Please contact Autogen Sales Department for full details of these options.