Вы находитесь на странице: 1из 2

epro • System III BS Between Slab Waterproofing

Seamless System • Extremely Strong and Durable • Excellent Adhesion • Exception Chemical Resistance • Redundant Protection

System Description Features & Benefits


System III BS is a field installed composite Seamless System - The fluid applied membrane
waterproofing system comprised of a water-based component of composite system ensure a
polymer modified asphalt (PMA) membrane with monolithic barrier even at the transitions.
polyester fabric reinforcement laminated to either a
Extremely Strong and Durable - The polyester fabric
polyolefin or HDPE geomembrane that is protected reinforcement increases the strength of the system
by a HDPE or polypropylene drainage composite, while the HDPE or polyolefin fabric provide a tough
with exceptional water and chemical protections. protective layer.

System Components Excellent Adhesion - The polymeric makeup of the


waterproofing membrane provides excellent
bonding to substrate even in damp conditions.
Ecoline-S (Interior Course): A spray fluid applied,
water-based polymer modified asphalt (PMA) Exceptional Chemical Resistance - The HDPE and
membrane. polyolefin component are very resistant to most
Ecoshield-E (Middle Course): A tough polyolefin contaminates.
geomembrane.
Redundancy - Provided by multiple waterproofing
Ecodrain-S (Exterior Course): A polypropylene membranes, protection courses and drainage.
core and non-woven polypropylene fabric drainage
composite.

Additional Information

Specifications - See Concrete Deck


Detail Drawing - Reference all CD and WP labeled
OF DIFFE
drawings. W
OR
LD RE
N
CE
A

Installation Guidelines - Reference 1.


Waterproofing Membrane Installation (Horizontal
S
FO

ON
R

Reinforced) 2. Waterproofing Membrane


TI

Wa te r p r oo f i n g Sys tems EA I
R

LW ND
ORLD CO

Installation (Vertical Reinforced) 3. Ecoshield 800-882-1896 • www.eproserv.com


Installation 4. Ecodrain Installation.
Insert drawings M-1 and N-1a on back

rev.sys3_bs010709
Drawing M-1

Drawing N-1a

epro • System III BS - Between Slab Waterproofing


Epro Between Slab Waterproofing System Testing
Water-based polymer modified asphalt (PMA) membrane with polyester fabric reinforcement laminated to either a
polyolefin or HDPE geomembrane. ( Ecoshield-E / Ecoline-S / Ecodrain-S )

Tensile Strength* ......................... ASTM D-412 .... 662 psi Chemical Permeation** .... ASTM F-739 Perm Rate Perm Rate
Elongation* .................................. ASTM D-412 .... 45% Ug/cm2 ml/day
Adhesion to Concrete*** .............. ASTM C-836 .... 11 lbf/in Chlorinated Solvent
Adhesion to Film .......................... ASTM C-836 .... 28.363 lbf/in Perchloroethylene ................................... 69.4 .......... 0.0008
Puncture Resistance ................... ASTM D-1709 .. 123 lb. Trichloroethylene .................................... 89.8 .......... 0.0012
Aromatic Hydrocarbon
Soil Burial* ................................... ASTM D-4068 Benzene .................... ............................ 59.3 .......... 0.0013
Weight change ..................... See Note 1 ...... 1.2% .......... passed
Tensile Strength ................... See Note 1 ...... 9.89% ........ passed Chemical Resistance** ...... ASTM D-543 Net change
Elongation ............................ See Note 1 ...... 2.2% .......... passed
Chlorinated Solvents ......... ASTM D-882 Mod. (Less 10% pass)
Heat Aging* ................................. ASTM D-4068 Perchloroethylene
Tensile Strength .................. See Note 1 ...... 8.6% .......... passed Weight ........................ ............................ 4.1%
Elongation .......................... See Note 1 ...... 8.9% .......... passed Tensile Strength ......... ............................ 6.5%
Tricholorethylene
Environmental Stress Cracking* .. ASTM D-1693 Weight ........................ ............................ 5.4%
Failure ................................ See Note 2 ...... 620 hrs. ..... passed Tensile Strength ......... ............................ 6.0%

Oil Resistance* .......................... ASTM D-543 & Aromatic Hydrocarbon


ASTM D-412 Benzene
Weight change ..................... See Note 1 ...... 7.6% .......... passed Weight ........................ ............................. 4.1%
Tensile Strength ................. See Note 1 ...... 1.1% .......... passed Tensile Strength ......... ............................ 4.4%
Elongation .......................... See Note 1 ...... 4.4% .......... passed
Gases
Methane Transmission* .............. ASTM D-1434 Hydrogen Sulfide
See Note 3 ...... 3.70xE-15... passed Weight ........................ ............................. 0.6%
Tensile Strength ......... ............................. 0.8%
* Tests performed by SGS / US Testing
** Tests performed by TRI Environmental
*** Tests performed by Momentum Technologies
OF DIFFE
LD RE
OR N
W
CE
A

Note 1: LA requires less than 10%


Note 2: LA requires over 500 hrs.
S
FO

ON

Note 3: LA requires less than 3 ml per day


R

Wa te r p r oo f i n g Sys tems
TI

EA I
R

LW ND
O RL D C O

800-882-1896 • www.eproserv.com

rev.sys3bs_122208

Вам также может понравиться