Академический Документы
Профессиональный Документы
Культура Документы
www.huawei.com
will be able to: Master data configuration procedure with CME Master procedure of NodeB data configuration
Page 2
References
WRAN CME User Guide BTS3812E&BTS3812A Initial Configuration Guide DBS3800 Initial Configuration Guide
Page 3
Page 4
Page 5
CME
RNS
RNC
RNS
NodeB
NodeB
RAN
RAN Initial Data Configuration
Configuring data based on the RAN network planning Exporting configuration data files Loading the files to the RNC and NodeB through LMTs
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6
CME
Script is downloaded and activated
RNS
RNC RNC
RNS
NodeB
NodeB
RAN
RAN Data Modification
Adding/deleting/modifying a RNC WRBS Adding/deleting/modifying a NodeB Adding/deleting/modifying a cell Modifying algorithm setting for RNO HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7
Configuring Transport
Page 8
Page 9
Create NodeB
Add NMPT
Add HBBU
Add HBBI Add HULP/HDLP Add UL BB Resource Group Add MTRU/MAFU Add HBOI Add NMON Add NAOI/NDTI NEMU/GPS Add NPMU Add NCMU
Add MRRU
Add NPSU
Add Battery
The basic data includes NodeB name and some basic NodeB data such as clock reference source, transmission line type, IP address, time zone, and demodulation mode
Note A NodeB name must be unique in one RNS
Page 11
Adding boards to the baseband subrack The board can be NMPT,NMON,HBBI,HBOI,HULP,HDLP,NDTI or NAOI board Note
You must configure NMPT first, and configure HBBI before configuring MTRU and MAFU. NMPT, HBBI/HBOI and NDTI/NAOI (alternative) are mandatory
H H H H H H B B U U U U B B L I I P L L L P P P
H H H H U U D D L L L L P P P P
N M P T
N M P T
N N N D A U T O T I I I
N M O N
N C C U
10
11
12
13 14
15
16
17
Page 12
Adding boards to the RF subrack. The board can be MTRU or MAFU board Note MTRU and MAFU have a one-to-one relationship You must add HBBI first before you are adding MTRU and MAFU
MAFU0
MAFU1
MAFU2
MAFU3
MAFU4
MAFU5
MTRU0
MTRU1
MTRU2
MTRU3
MTRU4
MTRU5
Page 13
Adding a UL baseband resource group and UL process units Note Each UL baseband resource group administrates up to six cells Cells in the same frequency band shall be assigned in the same UL baseband resource group
H H H H H H B B U U U U B B L I I P L L L P P P
H H H H U U D D L L L L P P P P
N M P T
N M P T
N N N D A U T O T I I
N M O N
N C C U
10
11
12
13 14
15
16
17
Page 14
Page 15
Adding HBBU
Adding an HBBU Note You can add only one HBBU to a NodeB
Page 16
Note
The MRRU chain or ring is configured to the HBBU/HBOI CPRI ports Each HBBU/HBOI has three CPRI ports The MRRU chain occupies one CPRI port, and the MRRU ring occupies two CPRI ports Adding MRRU
Chain Ring
Star
Note
For the data configuration of a distributed NodeB, each MRRU is considered as a subrack. The subrack number of an MRRU must be unique within the distributed NodeB system
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Antenna
Bracket
Jumper
TMA
Adding TMA
Adding a TMA
Jumper
Adding RET
Adding a RET
Feeder Jumper
NodeB Cabinet
Page 18
Page 19
Page 20
NBAP
CCP
Transport Network User Plane
CCP
Transport Network Control Plane Transport Network User Plane
ALCAP
A
SAAL UNI
B
SAAL UNI
C
AAL2 PATH
ATM
Physical Layer
Page 21
NodeB
CES AAL2 PATH CBR VBR-RT VBR-NRT NCP or CCP or ALCAP or IPoA
RNC
User Plane
NodeB
Adjnode
AAL2Path
RNC
AAL1
AAL2
AAL5
IMA/UNI/STM-1
VCI-101
VPI-10 VPI-10
ATM Cell
VCI-100 VCI-100
E1/T1/SDH(STM-1)
VCI-101
Page 22
Create NodeB
Add NDTI/HBBU
Add NAOI
Add ALCAP
Adding the physical links to the NodeB for data transmission over Iub interface Note
An E1/T1 port can be configured to any of the following links for data transmission:
UNI link Fractional ATM link IMA link CES link An optical port can be configured to any of the following links for data transmission: STM-1 link
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24
Physical ports(BTS3812E&A)
Board type Port number E1/T1 port No.0 E1/T1 port No.1 NDTI Work mode IMA,UNI, CES, Fractional ATM, Timeslot cross (connect with RNC) IMA,UNI, CES, Fractional ATM
IMA, UNI,
Timeslot cross (connect with lower level NodeB)
IMA,UNI
CES
STM-1
Page 25
Physical ports(DBS3800)
Board type Port number Work mode IMA,UNI, E1/T1 port No.0 Fractional ATM, Timeslot cross (connect with RNC) E1/T1 port No.1 IMA,UNI,
HBBU
E1/T1 port No.2~3
Fractional ATM
IMA, UNI, Timeslot cross (connect with lower level NodeB) E1/T1 port No.4~7 IMA,UNI
Page 26
ATM cell mapping field: 30 octets (TS1 - TS15 and TS17 - TS31) Header Header Header Header TS0 provides F3 OAM functions: Performance monitoring (CRC-4) Transmission of FERF and LOC Performance reporting Detection of loss of frame alignment TS16: Reserved for signaling
256 bits/125 ls
Page 27
PHY
PHY
Page 28
Add an IMA link to an IMA group IMA Link No. : defines the E1/T1 No. on the NDTI/HBBU
IMA Frame 2 IMA Frame 1 IMA Frame 0
...
ATM ATM ATM F ICP2 F
...
F ATM F ICP1 ATM
...
F ATM F ICP0
Link 0
m-1 F
...
1 F
0 F
m-1 ATM
...
m-1
...
2 F
0 F Link1
ICP2 ATM
ICP0 ATM
...
F ATM ATM ICP2 F ATM
...
F Time ATM layer cell ATM ICP1 ATM ATM
...
F ATM ICP0 ATM
Link2
Filler cell
ATM
Page 29
Adding a Fractional ATM Link Bearing port No. : defines the E1/T1 No. on the NDTI
ATM cell carrying Fractional ATM link NDTI E1 0/1 3G data Fractional E1 slots available for ATM cell, others may be used by 2G BTS
BTS38XX NDTI
RNC Iub interface board Transport other information rather than ATM cell
Page 30
Adding a Timeslot Across Channel Add the corresponding Fractional ATM link on NDTI/HBBU E1/T1 0 first
ATM cell carrying 3G data Fractional ATM Link Fractional E1/T1timeslots are used by Fractional ATM; other timeslots are used by timeslot across channel
BTS38XX NDTI
RNC Iub interface board Timeslot across channel timeslots available on NDTI No.2/3 E1/T1
2G BTS data
2G BSC data
Page 31
Adding a CES Channel If NDTI is used, NDTI No.0/1 E1 is directly connected to 2G BTS If NAOI is used, NAOI E1/T1 is directly connected to 2G BTS
3G data packed into ATM cell E1/T1 timeslot data packed into ATM cell E1/T1 timeslot data restored from ATM cell
BTS38XX NDTI/NAOI
RNC Iub interface board E1/T1, some timeslots available CES channel 2G BSC data
Page 32
Note
Only one NCP is configured to the NodeB Negotiated with the peer end RNC VPI and VCI of NCP Traffic over the NCP includes: Service type, Peak cell rate , Sustain cell rate
Page 33
Adding a CCP to the Iub interface Note One NodeB supports multiple CCPs
Page 34
Adding the ALCAP node to the NodeB and an ALCAP link to the Iub interface Note
Page 35
Page 36
Adding a Treelink PVC to the lower level NodeB The Treelink PVC enables the NodeB to connect with its upper level node and lower level NodeB through different E1/T1 ports Note
Page 37
AA RNC
E1/T1 or Optical fiber
D
BTS38XX(A)
A
E1/T1 or Optical fiber
BTS38XX(B)
Page 38
TREELINK PVC
AA RNC
E1/T1 or Optic fiber
A
E1/T1 or Optic fiber
BTS38XX (A)
BTS38XX (B)
BTS38XX (C)
Page 39
Page 40
User Plane
USCH FP
UDP IP Data Link Layer
NBAP
CCP CCP
SCTP
FACH FP
Physical Layer
Page 41
CPCH FP
Configure the MP
Configure the IP Route Configure the QoS NodeB (optional) Configure the NBAP IP Route Configure the OM IP Route Configure the IP path
End
Page 42
In a single transport mode, configure one type of transport links. In hybrid transport mode, configure E1 and FE transport links. For E1 links, configure PPP or MP. For FE links, configure PPPoE or Ethernet IP.
PDH/SDH
NodeB
IP network
RNC
IP hybrid transmission
Page 43
If the gateway type of the route is Ethernet, the next hop address and the gateway IP address must be in the same network segment If the NodeB and RNC are in layer 2 networking The IP addresses of the FE ports on the NodeB and RNC should be in the same subnet If the NodeB and RNC are in layer 3 networking The next hop address is the IP address of the router that connects to the NodeB or the IP address of the port on a layer 3 switch. The destination address of packets has the corresponding route in the routing table. The corresponding link layer address can be found only when the router specifies the next hop IP address (gateway). Configure just one route to the same destination address.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44
To configure signaling and OM priorities IP Quality of Service (QoS) is an IP network capability to provide specific services over the IP network that uses mutiple bottom-layer network technologies such as MP, FR, ATM, Ethernet, SDH, and MPLS IP QoS supports the switching between the IP precedence and DSCP The IP QoS configuration is flexible
Page 45
Configure destination IP address & local IP interface, port type and port number The IP routes for destination addresses are available Only one NCP can be configured Several CCPs can be configured The destination IP address, local port number, and destination port number of the NCP/CCP on the same link should be different When you choose one NCP/CCP on the NBAP tab page, the corresponding links are displayed in the middle part, and the corresponding routes are displayed in the lower part
Page 46
Ensure that the route from the LMT (or M2000) to the subnet is configured Only one OM channel can be configured
If you choose an OM channel in the upper part of the OM tab page, the corresponding route is displayed in the lower part The destination IP address of the OM channel is the IP address of the NodeB LMT or M2000
Page 47
The IP routes for destination addresses are available The IP path does not have bandwidth limit. Therefore, to configure the IP path is to differentiate service priorities. When the HSDPA service is transmitted, configure two IP paths with different path IDs. The two paths correspond to R99 service and HSDPA service. There is no service priority at the NodeB side. Therefore, configure one IP path at the NodeB side
If you choose one path on the upper part of the IP path tab page, the corresponding links are displayed in the middle part and the corresponding route is displayed in the lower part
Page 48
Page 49
Locall cell
Add Site
Add Sector
Page 50
Adding Site Adding a site to the NodeB Note A site number within one NodeB must be unique.
Adding Sector
Page 52
Page 53
maintenance:
Page 54
(A) (B)
IP0
IP1
Page 55
Configuring an IPoA maintenance channel to the NodeB Through the IPoA maintenance channel, you may log in to the NodeB remotely with the LMT or the M2000
Note
You can add only one IPoA maintenance channel to a NodeB Negotiated with the peer end RNC Local IP and Local IP Mask Peer IP and Peer IP Mask VPI/VCI Service Type
Page 56
Thank You