Вы находитесь на странице: 1из 57

Internal

NodeB Data Configuration


V100R007

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Upon completion of this course, you

will be able to: Master data configuration procedure with CME Master procedure of NodeB data configuration

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

References
WRAN CME User Guide BTS3812E&BTS3812A Initial Configuration Guide DBS3800 Initial Configuration Guide

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Chapter 1 Data Configuration Overview


Chapter 2 Configuring Physical Equipment Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell


Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

Data Configuration Overview


Configuration Tool CME

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

CME for Initial Configuration in Network Commissioning


Planned Radio data Cell Radio Parameter templates NodeB Templates

Wizards of the task focused Script is downloaded and activated


RNC

CME

RNS

RNC

RNS

NodeB

NodeB

RAN
RAN Initial Data Configuration

Configuring data based on the RAN network planning Exporting configuration data files Loading the files to the RNC and NodeB through LMTs
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6

CME for Data Modification in Network Expansion


Planned Radio data Cell Radio Parameter templates NodeB Templates

Wizards of the task focused Upload

CME
Script is downloaded and activated

RNS
RNC RNC

RNS

NodeB

NodeB

RAN
RAN Data Modification
Adding/deleting/modifying a RNC WRBS Adding/deleting/modifying a NodeB Adding/deleting/modifying a cell Modifying algorithm setting for RNO HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7

Data Configuration Overview


Procedure of NodeB Data Configuration

Configuring NodeB Data

Configuring Physical Equipment

Configuring Transport

Configuring Local cell

Physical equipment must be configured first

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

Chapter 1 Data Configuration Overview


Chapter 2 Configuring Physical Equipment Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell


Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Configuring Physical Equipment


Procedure of Physical Equipment Configuration
Physical Equipment Configuration

USED FOR 3812E&A

Create NodeB

USED FOR DBS3800

Add NMPT

Add HBBU

Add HBBI Add HULP/HDLP Add UL BB Resource Group Add MTRU/MAFU Add HBOI Add NMON Add NAOI/NDTI NEMU/GPS Add NPMU Add NCMU

Add MRRU Chain/Ring


Add NPMU for MBBU

Add MRRU

Add NPSU

Add Battery

Add NPMU For MRRU

End HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10

Configuring Physical Equipment


Creating NodeB

Adding NodeB basic data

The basic data includes NodeB name and some basic NodeB data such as clock reference source, transmission line type, IP address, time zone, and demodulation mode
Note A NodeB name must be unique in one RNS

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Configuring Physical EquipmentBTS3812E/A


Adding Boards to Baseband Subrack

Adding boards to the baseband subrack The board can be NMPT,NMON,HBBI,HBOI,HULP,HDLP,NDTI or NAOI board Note

You must configure NMPT first, and configure HBBI before configuring MTRU and MAFU. NMPT, HBBI/HBOI and NDTI/NAOI (alternative) are mandatory

H H H H H H B B U U U U B B L I I P L L L P P P

H H H H U U D D L L L L P P P P

N M P T

N M P T

N N N D A U T O T I I I

N M O N

N C C U

10

11

12

13 14

15

16

17

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Configuring Physical Equipment BTS3812E/A


Adding Boards to RF Subrack

Adding boards to the RF subrack. The board can be MTRU or MAFU board Note MTRU and MAFU have a one-to-one relationship You must add HBBI first before you are adding MTRU and MAFU

MAFU0

MAFU1

MAFU2

MAFU3

MAFU4

MAFU5

MTRU0

MTRU1

MTRU2

MTRU3

MTRU4

MTRU5

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Configuring Physical Equipment BTS3812E/A


Adding UL Baseband Resource Group

Adding a UL baseband resource group and UL process units Note Each UL baseband resource group administrates up to six cells Cells in the same frequency band shall be assigned in the same UL baseband resource group

H H H H H H B B U U U U B B L I I P L L L P P P

H H H H U U D D L L L L P P P P

N M P T

N M P T

N N N D A U T O T I I

N M O N

N C C U

10

11

12

13 14

15

16

17

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 14

Configuring Physical Equipment BTS3812E/A


Adding NPMU (only for BTS3812A)

Adding an NPMU and its PSU and batteries

Adding NCMU (only for BTS3812A)

The NCMU is the temperature control unit of the


BTS3812A.

Configuring NEMU (only for BTS3812E)

The NEMU is a peripheral of the NodeB

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Configuring Physical Equipment ----DBS3800

Adding HBBU

Adding an HBBU Note You can add only one HBBU to a NodeB

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 16

Configuring Physical Equipment DBS3800


Adding MRRU Chain/Ring

Adding an MRRU chain or ring

Note
The MRRU chain or ring is configured to the HBBU/HBOI CPRI ports Each HBBU/HBOI has three CPRI ports The MRRU chain occupies one CPRI port, and the MRRU ring occupies two CPRI ports Adding MRRU

Chain Ring

Star

Note
For the data configuration of a distributed NodeB, each MRRU is considered as a subrack. The subrack number of an MRRU must be unique within the distributed NodeB system
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17

Configuring Physical Equiment


Configuring GPS Receiver

Antenna

GPS receiver is a peripheral of the NodeB It is used to locate UE

Bracket

Jumper
TMA

Adding TMA

Adding a TMA
Jumper

Adding RET

Adding a RET
Feeder Jumper
NodeB Cabinet

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Chapter 1 Data Configuration Overview


Chapter 2 Configuring Physical Equipment Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell


Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Chapter 3 Configuring Transport


Sector 1 Configuring Transport over ATM

Sector 2 Configuring Transport over IP

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

Configuring Transport over ATM


Iub Interface protocol over ATM
Control Plane Radio Network Layer
NCP

User plane RACH FP FACH FP

NBAP
CCP
Transport Network User Plane

CCP
Transport Network Control Plane Transport Network User Plane

Transport Network Layer

ALCAP

A
SAAL UNI

B
SAAL UNI

C
AAL2 PATH

ATM
Physical Layer

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

Configuring Transport over ATM


Iub Interface protocol
Control Plane
ALCAP CCP 1~n NCP

NodeB
CES AAL2 PATH CBR VBR-RT VBR-NRT NCP or CCP or ALCAP or IPoA

RNC

User Plane

NodeB
Adjnode

Iub data segmentation packing

AAL2Path

RNC

AAL1

AAL2

AAL5

IMA/UNI/STM-1
VCI-101

VPI-10 VPI-10

ATM Cell

VCI-100 VCI-100

E1/T1/SDH(STM-1)

VCI-101

VPI-20 AAL Layer ATM Layer Physical Layer

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Configuring Transport over ATM


Procedure of Transport Configuration
Transport Configuration

Create NodeB

Add NDTI/HBBU

Add NAOI

Add IMA Group

Add UNI LINK

Add Fractional ATM Add Time Slot Across

Add STM-1 Link

Add IMA Link

Add ALCAP

Add NCP/CCP/ IPoA Device

Add Treelink PVC

Add CES (only3812E&A)

Add AAL2 Path

End HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23

Configuring Transport over ATM


Configuring Physical Links at Transport Layer

Adding the physical links to the NodeB for data transmission over Iub interface Note

An E1/T1 port can be configured to any of the following links for data transmission:
UNI link Fractional ATM link IMA link CES link An optical port can be configured to any of the following links for data transmission: STM-1 link
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24

Configuring Transport over ATM


Physical Links Configuration

Physical ports(BTS3812E&A)
Board type Port number E1/T1 port No.0 E1/T1 port No.1 NDTI Work mode IMA,UNI, CES, Fractional ATM, Timeslot cross (connect with RNC) IMA,UNI, CES, Fractional ATM

E1/T1 port No.2~3

IMA, UNI,
Timeslot cross (connect with lower level NodeB)

E1/T1 port No.4~7 NAOI

IMA,UNI

E1/T1 port No.0~3


Optical port No.0~1

CES
STM-1

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

Configuring Transport over ATM


Physical Links Configuration

Physical ports(DBS3800)
Board type Port number Work mode IMA,UNI, E1/T1 port No.0 Fractional ATM, Timeslot cross (connect with RNC) E1/T1 port No.1 IMA,UNI,

HBBU
E1/T1 port No.2~3

Fractional ATM
IMA, UNI, Timeslot cross (connect with lower level NodeB) E1/T1 port No.4~7 IMA,UNI

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Configuring Transport over ATM


Physical Links Configuration

Add an UNI link


Header ATM cell 53 octets

ATM cell mapping field: 30 octets (TS1 - TS15 and TS17 - TS31) Header Header Header Header TS0 provides F3 OAM functions: Performance monitoring (CRC-4) Transmission of FERF and LOC Performance reporting Detection of loss of frame alignment TS16: Reserved for signaling

256 bits/125 ls

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 27

Configuring Transport over ATM


Physical Links

Configuration Add an IMA Group


IMA group PHY Physical I ink #0 PHY IMA group

Physical I ink #1 PHY


Original ATM cell stream ATM from ATM layer

PHY Physical I ink #2

Recovered ATM cell stream to ATM layer

PHY

PHY

IMA virtual link

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 28

Configuring Transport over ATM


Physical Links Configuration

Add an IMA link to an IMA group IMA Link No. : defines the E1/T1 No. on the NDTI/HBBU
IMA Frame 2 IMA Frame 1 IMA Frame 0

...
ATM ATM ATM F ICP2 F

...
F ATM F ICP1 ATM

...
F ATM F ICP0

Link 0

m-1 F

...

1 F

0 F

m-1 ATM

...

m-1

...

2 F

0 F Link1

ICP2 ATM

ICP1 ATM ATM ATM ATM

ICP0 ATM

...
F ATM ATM ICP2 F ATM

...
F Time ATM layer cell ATM ICP1 ATM ATM

...
F ATM ICP0 ATM

Link2

Filler cell

ATM

ICP2 ICP cell in frame #2

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

Configuring Transport over ATM


Physical Links Configuration

Adding a Fractional ATM Link Bearing port No. : defines the E1/T1 No. on the NDTI
ATM cell carrying Fractional ATM link NDTI E1 0/1 3G data Fractional E1 slots available for ATM cell, others may be used by 2G BTS

BTS38XX NDTI

RNC Iub interface board Transport other information rather than ATM cell

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

Configuring Transport over ATM


Physical Links Configuration

Adding a Timeslot Across Channel Add the corresponding Fractional ATM link on NDTI/HBBU E1/T1 0 first
ATM cell carrying 3G data Fractional ATM Link Fractional E1/T1timeslots are used by Fractional ATM; other timeslots are used by timeslot across channel

NDTI No.0 E1/T1

BTS38XX NDTI

RNC Iub interface board Timeslot across channel timeslots available on NDTI No.2/3 E1/T1

2G BTS data

2G BSC data

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 31

Configuring Transport over ATM


Physical Links Configuration

Adding a CES Channel If NDTI is used, NDTI No.0/1 E1 is directly connected to 2G BTS If NAOI is used, NAOI E1/T1 is directly connected to 2G BTS
3G data packed into ATM cell E1/T1 timeslot data packed into ATM cell E1/T1 timeslot data restored from ATM cell

ATM cell transport

BTS38XX NDTI/NAOI

RNC Iub interface board E1/T1, some timeslots available CES channel 2G BSC data

E1/T1, some timeslots available 2G BTS data

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Configuring Transport over ATM


Adding NCP

Adding the NCP to the Iub interface

Note
Only one NCP is configured to the NodeB Negotiated with the peer end RNC VPI and VCI of NCP Traffic over the NCP includes: Service type, Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 33

Configuring Transport over ATM


Adding CCP

Adding a CCP to the Iub interface Note One NodeB supports multiple CCPs

Negotiated with the peer end RNC


CCP No. VPI and VCI of CCP Traffic over the CCP includes: Service type, Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

Configuring Transport over ATM


Adding ALCAP Node and link

Adding the ALCAP node to the NodeB and an ALCAP link to the Iub interface Note

One NodeB is configured with only one ALCAP link


Negotiated with the peer end RNC ATM address of NodeB VPI and VCI of the ALCAP link Traffic over the ALCAP link includes :Service type, Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

Configuring Transport over ATM


Adding AAL2 Path

Adding an AAL2 path to the Iub interface


Note One NodeB may have multiple AAL2 paths The number of paths can be calculated based on the traffic model over the Iub interface Negotiated with the peer end RNC AAL2 path ID VPI and VCI of the AAL2 path Traffic over the AAL2 path includes :Service type, Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 36

Configuring Transport over ATM


Adding Treelink PVC

Adding a Treelink PVC to the lower level NodeB The Treelink PVC enables the NodeB to connect with its upper level node and lower level NodeB through different E1/T1 ports Note

Optional for NodeB initial configuration


Add Treelink PVCs to all the upper level NodeBs when the NodeB is cascaded with the other NodeBs Negotiated with the lower level NodeB PVC to lower level NodeB Negotiated with the upper level NodeB PVC to upper level NodeB

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 37

Configuring Transport over ATM


Architecture of Treelink PVC
AAL layer and higher layer
TREELINK PVC

ATM layer (PVC)

ATM layer PVC

ATM physical layer bearer Transport Physical medium

ATM physical layer bearer Transport Physical medium

AA RNC
E1/T1 or Optical fiber

D
BTS38XX(A)

A
E1/T1 or Optical fiber

BTS38XX(B)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 38

Configuring Transport over ATM


VPI Planning for VP-only Switching Treelink PVC
AAL layer and the higher layer

TREELINK PVC

ATM layer (PVC)

ATM layer PVC

ATM physical layer bearer Transport Physical medium

ATM physical layer bearer Transport Physical medium

AA RNC
E1/T1 or Optic fiber

A
E1/T1 or Optic fiber

BTS38XX (A)

BTS38XX (B)

BTS38XX (C)

VPI range: (6, 6)

VPI range: (7, 7)

VPI range: (8, 8)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 39

Chapter 3 Configuring Transport


Sector 1 Configuring Transport over ATM

Sector 2 Configuring Transport over IP

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 40

Configuring Transport over IP


Iub interface protocol over IP
Control Plane
RACH FP

User Plane
USCH FP
UDP IP Data Link Layer

Radio Network Layer Transport Network Layer


NCP

NBAP
CCP CCP

Transport Network User Plane

Transport Network User Plane

SCTP

IP Data Link Layer

FACH FP

Physical Layer

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 41

CPCH FP

Configuring Transport over IP


Start

Configure the PPP

Configure the MP

Configure the PPPoE

Configure the Ethernet IP

Configure the IP Route Configure the QoS NodeB (optional) Configure the NBAP IP Route Configure the OM IP Route Configure the IP path

End

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 42

Configuring Transport over IP


Configure the PPP, MP, PPPoE, and Ethernet IP

In a single transport mode, configure one type of transport links. In hybrid transport mode, configure E1 and FE transport links. For E1 links, configure PPP or MP. For FE links, configure PPPoE or Ethernet IP.
PDH/SDH

NodeB

IP network

RNC

IP hybrid transmission

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 43

Configuring Transport over IP


Configure the IP route

If the gateway type of the route is Ethernet, the next hop address and the gateway IP address must be in the same network segment If the NodeB and RNC are in layer 2 networking The IP addresses of the FE ports on the NodeB and RNC should be in the same subnet If the NodeB and RNC are in layer 3 networking The next hop address is the IP address of the router that connects to the NodeB or the IP address of the port on a layer 3 switch. The destination address of packets has the corresponding route in the routing table. The corresponding link layer address can be found only when the router specifies the next hop IP address (gateway). Configure just one route to the same destination address.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44

Configuring Transport over IP


Configure the QoS

To configure signaling and OM priorities IP Quality of Service (QoS) is an IP network capability to provide specific services over the IP network that uses mutiple bottom-layer network technologies such as MP, FR, ATM, Ethernet, SDH, and MPLS IP QoS supports the switching between the IP precedence and DSCP The IP QoS configuration is flexible

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 45

Configuring Transport over IP


Configure the NBAP

Configure destination IP address & local IP interface, port type and port number The IP routes for destination addresses are available Only one NCP can be configured Several CCPs can be configured The destination IP address, local port number, and destination port number of the NCP/CCP on the same link should be different When you choose one NCP/CCP on the NBAP tab page, the corresponding links are displayed in the middle part, and the corresponding routes are displayed in the lower part

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 46

Configuring Transport Based on IP


Configure the OM

Ensure that the route from the LMT (or M2000) to the subnet is configured Only one OM channel can be configured

If you choose an OM channel in the upper part of the OM tab page, the corresponding route is displayed in the lower part The destination IP address of the OM channel is the IP address of the NodeB LMT or M2000

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 47

Configuring Transport over IP


Configure the IP path

The IP routes for destination addresses are available The IP path does not have bandwidth limit. Therefore, to configure the IP path is to differentiate service priorities. When the HSDPA service is transmitted, configure two IP paths with different path IDs. The two paths correspond to R99 service and HSDPA service. There is no service priority at the NodeB side. Therefore, configure one IP path at the NodeB side

If you choose one path on the upper part of the IP path tab page, the corresponding links are displayed in the middle part and the corresponding route is displayed in the lower part

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 48

Chapter 1 Data Configuration Overview


Chapter 2 Configuring Physical Equiment Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell


Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 49

Configuring Local Cell


Procedure of Local Cell Configuration

Locall cell

Add Site

Add Sector

Add Local Cell

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 50

Configuring Local Cell

Adding Site Adding a site to the NodeB Note A site number within one NodeB must be unique.

Adding Sector

Adding a sector to the NodeB


Note A sector number must be unique within one NodeB Configuring a sector is mainly configuring the corresponding antenna and feeder system
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51

Configuring Local Cell

Adding Local Cell


Adding a local cell to the NodeB Note Local Cell ID must be unique within the same NodeB Negotiated with the peer end RNC Local Cell ID Uplink Frequency Downlink Frequency

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 52

Chapter 1 Data Configuration Overview


Chapter 2 Configuring Physical Equiment Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell


Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 53

Configuring Operation and Maintenance Channel


NodeB provides two modes of operation and

maintenance:

Near end operation and maintenance:


Far end operation and maintenance:
NMPT Ethernet Port IP address IPoA Peer IP RNC BAM IP IPoA local IP SNTP Server Subnet 1 Subnet 2 RNC M2000 BTS3812E LMT1 LMT 2 Subnet 3 Subnet 5 Subnet 4

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 54

Operation and Maintenance Channel Configuration


IPoA maintenance configuration
The route to LMT (IP4), SNTP Server, gateway: IP2 IPoA peer IP: IP2

(A) (B)

Configure IPoA local IP: IP1

(C) Configure LMT Ethernet


IP: IP4

(D) Configure the route to BTS3812E (IP1), gateway:IP3

BTS3812E NMPT ETH IP


Lower level Node B IP6

IP0

IP1

IP2 IP4 LMT

IP3 LocalBTS3812E IP5 RNC

The route to LMT(IP4) gateway:IP5

Configure IPoA local IP: IP6

(B) Configure networking PVC

IPoA peer IP:IP5

Configure the route to lower NodeB (IP6), gateway:IP3

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 55

Configuring Operation and Maintenance Channel


Adding IPoA Device

Configuring an IPoA maintenance channel to the NodeB Through the IPoA maintenance channel, you may log in to the NodeB remotely with the LMT or the M2000

Note
You can add only one IPoA maintenance channel to a NodeB Negotiated with the peer end RNC Local IP and Local IP Mask Peer IP and Peer IP Mask VPI/VCI Service Type

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 56

Thank You
www.huawei.com

Вам также может понравиться