Вы находитесь на странице: 1из 68

Huawei GENEX Series

www.huawei.com

Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow Using Probe for Data Collection Other Features Case Study

www.huawei.com

2
Huawei confidential, 2007-10

Huawei GENEX Family


GENEX Nastar is a platform for monitoring and optimizing the performance of GSM/CDMA/WCDMA wireless networks

GENEX Nastar Network Performance Analysis System

GENEX Probe GENEX Assistant Test & Post-Process Tools


Downlink + Uplink

The GENEX Probe, network optimization and drive test data collection system, is an air interface test tool for WCDMA/HSDPA/HSUPA/GSM/GP RS networks. GENEX Assistant is a professional wireless test data post-processing software system.

RNC

GENEX U-Net Radio Network Planning Tool


3

GENEX U-Net is a radio planning tool that fully supports the technologies of GSM,GPRS-EDGE, CDMA IS95, WCDMA/UMTS/HSDPA/HSUPA, CDMA 2000/1xRTT/1xEVDO, and TD-SCDMA wireless networks.

www.huawei.com

3
Huawei confidential, 2007-10

Whole Flow Overview

GENEX covers the network lifecycle

Radio Network Planning Tool

Air Interface Test Tool and PostProcessing Tool Network Performance Analysis Tool

Make full use of 2G resources

www.huawei.com

4
Huawei confidential, 2007-10

GENEX Partners in The World


Applied in the Huawei 2G and 3G planning and optimization projects Covers more than forty countries, including commercial and pilot offices Assists the renowned operators in establishing and optimizing the network with high quality. The network operators include but not limited to: China Mobile, China Unicom, China Telecom, China Netcom, Vodafone, PBTL, T-Mobile, Orange, CellPlus, PCCW(Sunday), Telecom, eMobile. Aims at consistently providing the customers with professional and high-level solutions for network planning and optimization. Employed by network operators and designing institutes all over 26 provinces and municipalities Integrates the experiences of renowned operators, advancing with customers hand by hand.

www.huawei.com

5
Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow Using Probe for HSDPA / HSUPA DT Data Collection Other Features Case Study

www.huawei.com

6
Huawei confidential, 2007-10

GENEX Probe drive test system


*Support WCDMA 850/9001800/1900/2100Mhz

GARMIN Series GPS

Huawei Dual Mode Mobile(U626/U636)

Qualcomm TM6250/ 6275

AT Command Huawei WCDMA/HSDPA Data card Supported Mobile

Trimble Series GPS

DTI Scanner (Built-in GPS)

Anritsu Scanner

Equipment Composition Physical connection


support multi UE carry out different tests simultaneously
7

Equipment bag easy to carry and suitable to be used in the car 7

www.huawei.com

Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow Using Probe for Data Collection Other Features Case Study

www.huawei.com

8
Huawei confidential, 2007-10

DT Operation Flow
1. 2. 3. 4. 5. 6. 7. Probe Installation. Plug Probe dongle. (Must be installed Shared Hardware key) Connect Hardware device to the laptop. Hardware device configuration. System Configuration. (Set Log mask) Test Plan Configuration. Open the parameter widows you want to observe, such as RSCP and Ec/Io in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message, NAS Message, etc. 8. Import engineering parameters, open Map window and import the related Mapinfo file (.TAB). (Routes, Streets, etc) 9. Start Test, start recording. 10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start Test first, then start to make call test.
9

www.huawei.com

9
Huawei confidential, 2007-10

Probe Interface

Navigation

Area

Workspace Area

Status Area
10

www.huawei.com

10
Huawei confidential, 2007-10

Probe Interface
Navigation View

11

www.huawei.com

11
Huawei confidential, 2007-10

Project Template
Project Template
Site Verification
Optimize Benchmark Acceptance Customize

12

www.huawei.com

12
Huawei confidential, 2007-10

Hardware Configuration Before Test


Hardware configuration
In Navigation Area

Delete Device Add Device

Hardware Test

!!

Connect and config devices one by one

13

www.huawei.com

13
Huawei confidential, 2007-10

Hardware Configuration Before Test


Hardware configuration

!!

PS domain tests (Data Service) need set Modem port.

Hardware Configuration Test

Hardware Test

Devices status bar


14

www.huawei.com

14
Huawei confidential, 2007-10

Hardware Configuration Before Test


Hardware configuration Windows port allocation (port number)

15

www.huawei.com

15
Huawei confidential, 2007-10

Hardware Configuration Before Test


Hardware configuration General Parameters Personal Main Cities Test

Device

Type

Model DTI WCDMA (869.0-894.0 MHz) HUAWEI U1205 HUAWEI U1205 HUAWEI E270 Card***

Baudrate 115200 230400 230400 230400

Com Port A definir A definir A definir A definir

Modem Port A definir A definir A definir A definir

MSISDN A definir A definir A definir A definir

Scanner1 Scanner UE1 UE2 UE3 UE UE UE

*** No es el modelo pero funciona adecuadamente

16

www.huawei.com

16
Huawei confidential, 2007-10

Hardware Configuration Before Test


Hardware configuration General Parameters Personal Acceptance Test

Device UE1 UE2 UE3

Type UE UE UE

Model HUAWEI U1205 HUAWEI U1205 HUAWEI E270 Card***

Baudrate 230400 230400 230400

Com Port A definir A definir A definir

Modem Port A definir A definir A definir

MSISDN A definir A definir A definir

*** No es el modelo pero funciona adecuadamente

17

www.huawei.com

17
Huawei confidential, 2007-10

DT Operation Flow
1. 2. 3. 4. 5. 6. 7. Probe Installation. Plug Probe dongle. (Must be installed Shared Hardware key) Connect Hardware device to the laptop. Hardware device configuration. System Configuration. (Set Log mask) Test Plan Configuration. Open the parameter widows you want to observe, such as RSCP and Ec/Io in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message, NAS Message, etc. 8. Import engineering parameters, open Map window and import the related Mapinfo file (.TAB). (Routes, Streets, etc) 9. Start Test, start recording. 10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start Test first, then start to make call test.
18

www.huawei.com

18
Huawei confidential, 2007-10

System Configuration Before Test


Log Mask setting
Set Log Mask

Set Log Name Set Log file size Location of saved logs

19

www.huawei.com

19
Huawei confidential, 2007-10

Log Mask Setting Before Test


Log Mask setting General Parameters Personal Main Cities Test
Log item Setting: Valores que aparecen por defecto

Device

Limit

Size Type Time (Minutes) Time (Minutes) Time (Minutes) Time (Minutes)

Minutes 15 15 15 15

Log File Directory A convenir A convenir A convenir A convenir

Scanner1 Limited UE1 UE2 UE3 Limited Limited Limited

20

www.huawei.com

20
Huawei confidential, 2007-10

Log Mask Setting Before Test


Log Mask setting General Parameters Personal Acceptance Test
Log item Setting: Valores que aparecen por defecto

Device UE1 UE2 UE3

Limit Limited Limited Limited

Size Type Time (Minutes) Time (Minutes) Time (Minutes)

Minutes 15 15 15

Log File Directory A convenir A convenir A convenir

21

www.huawei.com

21
Huawei confidential, 2007-10

System Configuration Before Test


Event setting
We can define the event we need through Event setting.

22

www.huawei.com

22
Huawei confidential, 2007-10

System Configuration Before Test


Alarm setting
We can define the alarm event we need through Alarm setting.

23

www.huawei.com

23
Huawei confidential, 2007-10

System Configuration Before Test


Other setting
We can set the Time Record Mode for a Log Packet, GPS synchronization Mode, DialUp Property for Data Service, Display Filter for Log Data, Replay Mode for Event and Parameters for DTI Scanner which we need through other setting.

24

www.huawei.com

24
Huawei confidential, 2007-10

DT Operation Flow
1. 2. 3. 4. 5. 6. 7. Probe Installation. Plug Probe dongle. (Must be installed Shared Hardware key) Connect Hardware device to the laptop. Hardware device configuration. System Configuration. (Set Log mask) Test Plan Configuration. Open the parameter widows you want to observe, such as RSCP and Ec/Io in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message, NAS Message, etc. 8. Import engineering parameters, open Map window and import the related Mapinfo file (.TAB). (Routes, Streets, etc) 9. Start Test, start recording. 10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start Test first, then start to make call test.
25

www.huawei.com

25
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Configuration
Control each device's behavior by selecting Test Plan items and setting property parameters of each test items.

26

www.huawei.com

26
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Configuration Add & Config Scenarios for UE
Set the Test Plan respectively for each device (UE/Scanner).

1. Select Test Device 2. Add Test Scenario 4. Set Test Properties

3. Add Test Item

27

www.huawei.com

27
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Configuration Auto Call scenario

!!

Check the enable status

To modify the scenario To run scenario automatically

28

www.huawei.com

28
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Configuration Add & Config Scenarios for DTI Scanner
2. Set Item Property

1. Select Test Item

!!

Check the enable status

29

www.huawei.com

29
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
1. Voice call

Suggestion: When testing voice call, do not perform PS dialup on the Modem of the outgoing UE manually. Otherwise, voice call maybe hangs up abnormally. The UE that is performing PS services can serve as an incoming UE for Voice Call or Video Phone test. Thus, the CS and PS concurrent test can be performed on the same UE.
30

www.huawei.com

30
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Voice Call:
Call type
Continuous Call: The call continues if it does not fail, drop, or hang up. If the call fails, drops, or hangs up, Probe waits for a call interval to originate another call. Call by Call: call: The call lasts and waits for the predetermined calling duration and call interval, and repeats for the times defined in call count.

Setup time: the maximum time for call setup. If the call cannot be setup within the defined period,
the call setup fails.

Calling duration: the duration of one call, from call setup to call normal release. (apply only to
call by call)

Call interval: the time between two calls, from the previous call disconnection to the beginning of
the next call.

Exceptional Interval The interval between the exceptional end of a call drop and the
beginning of the next call.

Count Mode: the limitations on the call number -> Finite / Infinite.
31

www.huawei.com

31
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
2. Ftp Upload / Ftp Download

Note: PS connection can be set up by one FTP Download test item if correct APN has been set in UE.
32

www.huawei.com

32
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Ftp Download / Ftp Upload :
User, Password: FTP user name and password. For anonymous login, also need to input
anonymous as username.

Remote File: Destination file address, input the detailed download path, such as,
ftp://10.0.0.1/download/1.dat

Local File: Local path to save the download file, such as, C:\1.dat MultiTask Count: When we use multi-threading download, set the number of threads here. Test Interval (sec): The time interval between multi downloads. After finishing a download, wait
for several time, then start another download test.

FTP Count: the total number of ftp download test.

33

www.huawei.com

33
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Ftp Download / Ftp Upload:
Disconnection Mode: the mode of Disconnection, there are three choices:
Keep Disconnected: Do not perform PDP context deactivation ( remain RRC connection) after
the target files are loaded completely, just wait for interval time then continue next ftp download test.

Disconnect By Time: Perform PDP context deactivation periodically. The period for the PDP
context deactivation is represented by the Valid FTP Duration parameter. If the target files are not loaded completely within the predefined time, the loading result shows timeout. Probe considers this loading as failure and initiates another PDP context deactivation in the next loading.

Disconnect After Transfer Complete: Each time when the file load is complete, PDP
context deactivation would be performed.

FTP QoS : Indicates the type of the traffic as: Background class
Conversational class Interactive class Streaming class Subscribed class

FTP Upload:
Parameters are the same with FTP downloads. Probe will upload the local file to the destination path automatically. **Make sure you have the authority to upload file before test.
34
Huawei confidential, 2007-10

34

www.huawei.com

Test Plan Configuration Before Test


About APN, QoS Setting
If leave APN, QoS parameters blank Probe wont send the associated command to the UE if the parameters mentioned above is not set, that is the UEs default setting will be maintained. Methods for setting APN, QoS and their correlationship

1) Set by AT command in MODEM initial command


2) Set by Probe in Test Plan

!!

When both Probe and MODEM have APN and QoS information, because AT command in MODEM initial command is send to UE more closely before PS connection setup, it will replace the information send to UE by Probe. That is Probes setting doesnt work if AT command also exists in the MODEM initial command.

35

www.huawei.com

35
Huawei confidential, 2007-10

Test Plan Configuration Before Test


About APN, QoS Setting
Method 1 (By Windows) Method 2 (by Probe)

36

www.huawei.com

36
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan Configuration for DTI Scanner

!! Check the enable status

37

www.huawei.com

37
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Voice Call Short Call General Parameters Personal Main Cities and Acceptance Test
UE: Scenario Name: UE1 Short Call Test Item: Voice Call Destination: Call Type: Setup Time(sec): Call Duration(sec): A definir Call by Call 20 60

Call Interval(sec):
Exceptional Interval(sec): Count Mode:

10
20 Infinite

38

www.huawei.com

38
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Voice Call Long Call General Parameters Personal Main Cities and Acceptance Test
UE: Scenario Name: UE2 Long Call Test Item: Voice Call Destination: Call Type: Setup Time(sec): Call Duration(sec): A definir Call by Call 20 180

Call Interval(sec):
Exceptional Interval(sec): Count Mode:

10
20 Infinite

39

www.huawei.com

39
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan FTP Test Download General Parameters Personal Main Cities and Acceptance Test
UE:
Scenario Name:

UE3
FTP Download Test Item: Ftp Download Port: User: Password: 21 A definir A definir A definir False 5 5 999 Disconnected after transfer complete Background Class

APN:

Remote File: Write Local File: MultiTask Count: Test Interval(sec): Ftp Count: Disconnection Mode: Traffic Class: UL Max Rate(Kbps): DL Max Rate(Kbps):

gprs.personal.com

40

www.huawei.com

40
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Scanner General Parameters Personal Main Cities Test
Scanner:
Item Name*: Channel: Scanner Type: Pilot Number(N): Correlation Taps: Chip Window Size: PNThreshold(dB): ScanRate(ms): Measure Ec/Io: Measure Time Offset: Measure Aggregate Ec/Io: Measure Delay Spread: Measure Eps/Io: Measure Ess/Io:
41

Scanner1
TopN Pilot Scan Enable: TRUE A convenir A convenir 10 1 32 -20.5 100 TRUE FALSE TRUE FALSE FALSE FALSE 41
Huawei confidential, 2007-10

Measure Rake Finger Count: Measure SIR:

FALSE TRUE

*Los demas Item Name (Pilot Scan, Spectrum Analysis, CW, SCH Scan, RSSI 3.84M) deben estar en FALSE en la opcion de Enable.

www.huawei.com

DT Operation Flow
1. 2. 3. 4. 5. 6. 7. Probe Installation. Plug Probe dongle. (Must be installed Shared Hardware key) Connect Hardware device to the laptop. Hardware device configuration. System Configuration. (Set Log mask) Test Plan Configuration. Open the parameter widows you want to observe, such as RSCP and Ec/Io in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message, NAS Message, etc. 8. Import engineering parameters, open Map window and import the related Mapinfo file (.TAB). (Routes, Streets, etc) 9. Start Test, start recording. 10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start Test first, then start to make call test.
42

www.huawei.com

42
Huawei confidential, 2007-10

Parameter Window
Common used windows for HSDPA & R99

43

www.huawei.com

43
Huawei confidential, 2007-10

Parameter Window
WCDMA - Serving, Active Set & Neighboring Cells
Display PSC, RSCP, Ec/Io for active set, monitor set and detective set

In the figure, rectangle legend implicates active set data, circle implicates monitor set data, and triangle implicates detected set data. The data of the same type is distinguished from each other with different colors. Move the mouse to a place to get the scrambling code of the current point.
When the UE is in idle state, PSC in active set is about the cell where the UE resides.
44

www.huawei.com

44
Huawei confidential, 2007-10

Parameter Window
WCDMA - Power Control
DL SIR, SIR Target

Rx: UE received power; Tx: UE tx power

UL/DL transmit power control

45

www.huawei.com

45
Huawei confidential, 2007-10

Parameter Window
WCDMA - WCDMA BLER

Displays BLER of different transport channels.

In HSDPA connection mode, ADPCH's DL BLER is being displayed.

46

www.huawei.com

46
Huawei confidential, 2007-10

Parameter Window
WCDMA - HSDPA Link Statistic

47

www.huawei.com

47
Huawei confidential, 2007-10

Parameter Window
Message - MAC/RLC Messages
The MAC/RLC Messages window displays the messages about Media Access Control (MAC) and Radio Link Control (RLC). The messages are visible only when the associated items in LogMask are selected.

48

www.huawei.com

48
Huawei confidential, 2007-10

Parameter Window
Message - RRC Messages
All the UEs or single UE are displayed on the window. The messages selected on the left navigation tree are displayed. The detailed information is displayed by double-clicking on the message.

49

www.huawei.com

49
Huawei confidential, 2007-10

Parameter Window
Message - NAS Messages
Whatever mode UE is in, WCDMA, HSDPA or GSM, all the NAS messages are displayed here as follow:

50

www.huawei.com

50
Huawei confidential, 2007-10

Parameter Window
Scanner TopN Pilot & Spectrum Analysis

Top N Pilot test

51

www.huawei.com

51
Huawei confidential, 2007-10

Parameter Window
Data Service - App Throughput
Display both UL and DL application layer data rate, NAS rate and TCP retransmission rate.

52

www.huawei.com

52
Huawei confidential, 2007-10

Parameter Window
Data Service - RLC Throughput
Display both UL and DL RLC layer throughput, UL PDU retransmission ratio and DL PDU error ratio.

53

www.huawei.com

53
Huawei confidential, 2007-10

Parameter Window
Data Service - FTP Service Quality Evaluation
Displays the associated indicators on the user plane of the FTP service, including Login time, download time, download rate, etc.

54

www.huawei.com

54
Huawei confidential, 2007-10

Parameter Window
UE State
Displays the information of the mobile status and network parameters (cell, rnc, MCC, MNC, LAC, RAC)

55

www.huawei.com

55
Huawei confidential, 2007-10

Parameter Window
Information
Displays the information of hardware used and the test plan running

56

www.huawei.com

56
Huawei confidential, 2007-10

Parameter Window
Map Window

57

www.huawei.com

57
Huawei confidential, 2007-10

Parameter Window
Map Window Load WCDMA sites

58

www.huawei.com

58
Huawei confidential, 2007-10

59

www.huawei.com

59
Huawei confidential, 2007-10

Contents

Case1. Inter-RAT handover test Case2. WCDMA inter-frequency handover test Case3. Multi-frequency Scanning

60

www.huawei.com

60
Huawei confidential, 2007-10

Case1. Inter-RAT handover test


Inter-RAT handover test

Event observation Location of handover point

61

www.huawei.com

61
Huawei confidential, 2007-10

Case1. Inter-RAT handover test


Inter-RAT handover

Time of Handover signaling

Messages and measurement from different networks

62

www.huawei.com

62
Huawei confidential, 2007-10

Case2. WCDMA inter-frequency handover test


WCDMA inter-frequency handover

The signal frequency in active set is 2137.40 when the test starts
Signaling window

Log file:
63

www.huawei.com

63
Huawei confidential, 2007-10

Case2. WCDMA inter-frequency handover test


WCDMA inter-frequency handover process
Signaling observation before handover

64

www.huawei.com

64
Huawei confidential, 2007-10

Case2. WCDMA inter-frequency handover test


WCDMA inter-frequency handover process

Observe it again, and the frequency handover to 2132.40


65

www.huawei.com

65
Huawei confidential, 2007-10

Case3. Multi-frequency Scanning


Simultaneous scanning of multifrequency
2. Scanned multifrequency

1. Set multi-frequency

3. Select specified frequency to observe it


66

www.huawei.com

66
Huawei confidential, 2007-10

Case3. Multi-frequency Scanning


Simultaneous scanning of multi-frequency
Simultaneous observation of different frequencies

67

www.huawei.com

67
Huawei confidential, 2007-10

www.huawei.com

Huawei confidential, 2007-10

Вам также может понравиться