1. Data Configuration Overview 2. Preparation 3. Configuring the Global Information 4. Configuring the Equipment Data
Page1
Configuration Tools
a) Batch mode: multiple MML commands in a script b) Single Command Mode: one command at a time and carry it out directly CME (Configuration Management Express)
Based on GUI (Graphic User Interface)
Page2
LOAD
Page3
Contents
Preparation
1. Data Configuration Overview 2. Preparation 3. Configuring the Global Information 4. Configuring the Equipment Data
Global data configuration
LOAD
Page4
Preparation
1. Configuration Management:
2.Configuration Mode:
Page5
Preparation (Cont.)
1. Get configuration management rights (REQ CMCTRL) 2.Configure BSC through commands 3. release configuration management rights (RELCMCTRL)
User 1
Page6
Preparation (Cont.)
1. Get configuration management rights (FOC CMCTRL) 2.Configure BSC through commands 3. release configuration management rights (RELCMCTRL)
User 2
Page7
Preparation (Cont.)
FAM
Command BAM
Update database
LMT
Page8
Preparation (Cont.)
Step 1: Command
FAM
BAM
Update database Saved as *.MML LMT
Step 2:
restart FAM BAM Format from *.MML to *.DAT
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page9
Command
LMT
Contents
Preparation
1. Data Configuration Overview 2. Preparation 3. Configuring the Global Information 4. Configuring the Equipment Data
Configuring the Global Information
LOAD
Page10
Set the basic GSM data Add a primary GSM operator Add an OPC Add a DPC
Page11
Set the basic GSM data SET BSCBASIC: <Name>, <AreaCode>, <CC>, <AVer>, <UmVer>, <AbisVer>, <SupportVoiceTFO>, <HiFreqBandSupport>, <NTPSrv>, <ServiceMode>,......;
Name: name of the BSC, Actual Value Range: 1~64 characters AreaCode: Local area code, for example, 0755 for Shenzhen CC: Country code, for example, 86 for China AVer, UmVer, AbisVer: Phase tag for GSM protocols supported by the A, Um, Abis interface
Page12
SupportVoiceTFO: Whether to enable the tandem free operation (TFO) function, Actual Value Range: NO, YES
HiFreqBandSupport: Type of a high frequency type supported by the BSC6900, Actual Value Range: DCS1800, PCS1900
NTPSrv: IP address of the network time protocol (NTP) server that provides the time for the BSC system
ServiceMode: Service mode of the BSC6900, Actual Value Range: SEPARATE, TOGETHER, AIP
Page13
ATERTRANSMODE: Transport mode of the Ater interface, Actual Value Range: TDM, IP
Example:
SET BSCBASIC: Name="BSC6900", AreaCode=0755, CC=86, AVer=GSM_PHASE_2Plus, UmVer=GSM_PHASE_2Plus, AbisVer=GSM_PHASE_2Plus, SupportTFOCodecOptimize=NO, HiFreqBandSupport=DCS1800, ServiceMode=SEPARATE, ATERTRANSMODE=TDM;
Page14
Add a primary GSM operator ADD GCNOPERATOR: <OperatorType>, <OPNAME> <MCC>, <MNC>;
OperatorType: Primary operator or secondary operator, Actual Value Range: PRIM, SEC
OPNAME: Name of the operator MCC: Mobile country code MNC: Mobile network code
Page15
Example:
Page16
NAME: OSP name SPX: OSP index, Actual Value Range: 0~4 NI: Network ID, Actual Value Range: INT, INTB, NAT, NATB SPCBITS: OSP code bits, Actual Value Range: BIT14, BIT16, BIT24
SPC: Hexadecimal OSP code, Actual Value Range: 1~16383(BIT14), 1~65535(BIT16), 1~16777215(BIT24)
Page17
Add an OPC
Example:
Page18
Add a DPC ADD N7DPC: <NAME>, <DPX>, <SPX>, <SPDF>, <DPC>, <DPCT>, <BEARTYPE>;
NAME: DSP name DPX: DSP index. It is unique SPX: OSP index DPC: DSP code DPCT: DSP type, choose A for GSM only mode BEARTYPE: DSP bearer type, it indicates whether the lower layer bearer is the MTP3 or M3UA
Page19
Add a DPC
Example:
Page20
Contents
1. Data Configuration Overview 2. Preparation 3. Configuring the Global Information 4. Configuring the Equipment Data
Preparatio n
Configuring the Global Information
LOAD
Page21
Set the system information SET SYS: <SYSDESC>, <SYSOBJECTID>, <SYSCONTACT>, <SYSLOCATION>, <SYSSERVICES>;
SYSDESC: Description of the Base Station Controller SYSOBJECTID: Identifier of the Base Station Controller SYSCONTACT: Contact way of the Base Station Controller supplier
SYSLOCATION: Location of the Base Station Controller SYSSERVICES: Services provided by the Base Station Controller
Page22
Example:
SET SYS: SYSDESC="Lab use", SYSOBJECTID="Zone 13-1", SYSCONTACT="http://support.huawei.com", SYSLOCATION="BH01", SYSSERVICES="CS & PS";
Page23
CN: Cabinet No. CABT: Whether the added cabinet is a remote cabinet Example:
Page24
SRN: Subrack No. SRName: Name of the subrack to be added TYPE: Type of the subrack Example:
Page25
Add a board ADD BRD: <SRN>, <BRDCLASS>, <BRDTYPE>, <LGCAPPTYPE>, <SN>, <MPUSUBRACK>, <MPUSLOT>;
SRN: Subrack No. BRDCLASS: Classes of boards classified according to function modules, Actual Value Range: INT, DPU, XPU, TNU, OMU
BRDTYPE: Type of the board, Actual Value Range: PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa, OMUa, OMUb
Page26
Add a board
LGCAPPTYPE: Logic function type of the board, Actual Value Range: OAM, TDM_Switching, GCP, UCP, RGCP, RUCP, IBCA, GTC, GPCU, UUP, ATM, IP, FR, HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP
Page27
Add a board
Example:
Page28
Add a communication path between two subracks ADD SRCONPATH: <SRN1>, <SRN2>, <TDMN1>, <TDMN2>;
SRN1, SRN2: Number of the subrack of one end of the intersubrack connection channel
TDMN1, TDMN2: TDM Port No, each TNU board has 6 ports, ranging from 0 to 5.
Example:
Page29
Set the time zone and daylight saving time SET TZ: <ZONET>, <DST>;
ZONET: Time zone DST: Whether daylight saving time starts Example:
Page30
Add the information about the SNTP server ADD SNTPSRVINFO: <IP>, <PT>;
IP: IP address of the SNTP server PT: Number of the port that provides the time information on the SNTP server, the default port number of M2000 is 123
Example:
Page31
Contents
1. Data Configuration Overview 2. Preparation 3. Configuring the Global Information 4. Configuring the Equipment Data
Preparatio n
Configuring the Global Information
LOAD
Page32
Add an Ater connection path between the MPS and the TCS ADD ATERCONPATH: <ATERIDX>, <BMSRN>, <BMSN>, <BMPN>, <TCSRN>, <TCSN>, <TCPN>;
BMSRN: BM subrack No. where one end of the ATER connection channel is located
BMSN: BM slot No. where one end of the ATER connection channel is located
Page33
Add an Ater connection path between the MPS and the TCS
TCSRN: TC subrack No. where one end of the ATER connection channel is located
TCSN: TC slot No. where one end of the ATER connection channel is located
TCPN: TC port No. where one end of the ATER connection channel is located
Example:
Page34
CNNODEIDX: Node index of an MSC DPX: DSP index DPCGIDX: Signaling group of a DSP OPNAME: Name of the operator CNID: Used to uniquely identify an MSC
Page35
Add an E1/T1 over the A interface ADD AE1T1: <SRN>, <SN>, <PN>, <DPCGIDX>, <OPCIDX>, <BSCFLAG>, <STCIC>;
SRN: Subrack No. SN: Slot No. PN: Port No. DPCGIDX: DPC group index OPCIDX: OPC index
Page36
ALLTSTYPE: Value ALLCIC indicates that all E1/T1 timeslots on the A interface are of CIC type, Value ALLNULL indicates that all E1/T1 timeslots on the A interface are of null type
BSCFLAG: It indicates whether the A interface E1/T1 is the primary BSC or secondary BSC
STCIC: Number of the start CIC. The CIC of other timeslot will be calculated automatically on the basis of this parameter
Page37
Example:
Page38
SIGLKSX: To identify an signaling link set uniquely DPX: DSP index NAME: Signaling link set name Example:
Page39
Add an MTP3 signaling link ADD MTP3LNK: <SIGLKSX>, <SIGSLC>, <BEARTYPE>, <TCMODE>, <ATERIDX>, <ATERTSMASK>, <ASRN>, <ASN>, <MTP2LNKN>, <APN>, <ATSMASK>;
SIGLKSX: To identify an signaling link set uniquely SIGSLC: M3UA link ID of the specified link set BEARTYPE: Link bearer type TCMODE: To specify the mode of TC ATERIDX: Index of an Ater connection path
Page40
ATERMASK: Ater interface timeslot mask ASRN: A interface subrack No. ASN: A interface slot No. MTP2LNKN: To identify an MTP2 link APN: A interface port No. ATSMASK: A interface timeslot mask NAME: One MTP3 link name
Page41
Example:
ADD MTP3LNK: SIGLKSX=0, SIGSLC=0, BEARTYPE=MTP2, TCMODE=SEPERATE_PRINCIPAL, ATERIDX=0, ATERMASK=TS16-1, ASRN=3, ASN=20, MTP2LNKN=0, APN=0,
Page42
DPX: DSP index SIGLKSX: To identify an signaling link set uniquely NAME: One MTP3 route name Example:
Page43
Add a CN node
Example:
Page44
Contents
1. Data Configuration Overview 2. Preparation 3. Configuring the Global Information 4. Configuring the Equipment Data
Preparatio n
Configuring the Global Information
LOAD
Page45
Set the clock source of the interface board SET CLK: < SRT>, <SRN>, <SN>, <BT>, <REF2MCLKSR>, <BACK8KCLKSW1>;
SRT: Type of the subrack SRN: Subrack No. SN: Slot No. BT: Board type Example:
Page46
Add the clock source of the system ADD CLKSRC: <SRCGRD>, <SRCT>;
Page47
Set the work mode of the system clock source SET CLKMODE: <MODE>;
Page48
Page49
Summary
We have configured the finished the BSC6900(GO) data configuration, including: global data configuration, equipment data configuration, interfaces data configuration and clock cata configuration.
Page50
Thank you
www.huawei.com