Determination of the Identity of an unknown organic compound using selected physical properties, Infrared Spectroscopy, and NMR Spectroscopy
Unknown List: pp. 126 127 in Slayden Lab Manual References
Slayden, Pavia,
et al.
Schornick
04/11/13
http://classweb.gmu.edu/jschorni/chem318
Overview
Physical Properties
Boiling
Physical
(Relative to Water)
04/11/13
Title Use Short, Concise terms Simple Distillation, Refractive Index, IR Spectrum, etc.
Materials & Equipment (2 Columns in list (bullet) form) Note: include all reagents & principal equipment used
04/11/13
04/11/13
Several experiments in Chem 315/318 (Org Lab I & II) involve the identification of an unknown compound Liquid samples that students receive in Lab may contain some impurities in addition to the unknown compound that could produce ambiguous results when determining the chemical or physical properties of the compound Simple Distillation is used to purify the sample by separating the pure compound that comes over in a narrow temperature range corresponding to its boiling point from impurities that have boiling points either lower than or higher than the compound
04/11/13
04/11/13
Boiling Point The normal boiling point (also called the atmospheric boiling point or the atmospheric pressure boiling point) of a liquid is the temperature at which the vapor pressure of the liquid is equal to 1 atmosphere (atm), the atmospheric pressure at sea level At that temperature, the vapor pressure of the liquid becomes sufficient to overcome atmospheric pressure and allow bubbles of vapor to form inside the bulk of the liquid. The standard boiling point is now (as of 1982) defined by IUPAC as the temperature at which boiling occurs under a pressure of 1 bar 1 bar = 105 Pascals = 0.98692 atmospheres = 14.5038 psi (pounds per square inch)
6
04/11/13
Note: The distillation procedure description includes the equipment setup process and the steps taken to collect the data Equipment Heating Plate (from cabinet to right of entrance door) Sand Bath to hold distillation flask 25 mL Distillation Flask Distillation Head Thermometer & Thermometer Adapter
04/11/13 8
50 mL beaker for low boiling point and high boiling point impurities. 50 mL Erlenmeyer flask for purified sample
Procedure
Note: Adjust height of apparatus so that sample receiving containers (small beaker & small Erlenmeyer flask) can
04/11/13 9
Procedure (Cont) Use tablets, books, etc., to adjust height of Heating Plate Use blue clamp to attach distillation flask to distillation head Use blue plastic clamp to secure condenser tube to distillation head Tighten tongs of clamp supporting the condenser tube just enough to ensure condenser tube water-input/output ports point outward or slightly up Insert thermometer through adapter so that bulb is positioned just below elbow opening to
10
04/11/13
04/11/13
11
Set Hot Plate Heat control unit to 4-5 Use 50 mL beaker to collect low boiling point impurities Collect drops of condensate in waste beaker until temperature rise slows down and becomes constant Note: It may be necessary to increase the temperature setting on the controller
Collect purified sample condensate in 50 mL Erlenmeyer flask throughout the period when the temperature is relatively constant
04/11/13
12
If the temperature begins to increase again, turn the heat off, remove the Erlenmeyer flask, and collect any remaining condensate in the waste beaker Put the purified sample back into the original vial for further processing Dispose of any waste organic liquid in the jar in the hood
04/11/13
13
04/11/13
14
Refractive Index Abbe Refractometer (Bausch & Lomb) Clean prisms with tissues & methyl alcohol BE GENTLE!! Do not touch prism with fingers or other hard objects, use tissues Use sufficient drops of sample to cover pridm surface Close hinged prisms together - Gently Use switch on left to turn on the light Move hinged lamp up into position
15
04/11/13
Rotate coarse and fine adjustment knob on the right side of instrument until horizontal dividing line (may not be sharp at first) between the light (Top) and dark (Bottom) halves of the visual field coincide with the center of the cross-hairs Use eyepiece to focus cross-hairs If horizontal line dividing light & dark areas appears as a colored band (chromatic aberration), adjust with the knurled drum knob on the front of the instrument Press switch on left side of instrument down to make the scale visible
16
04/11/13
Index of Refraction (ND) is the ratio of the speed of light in a vacuum (air) vs. the speed of light in a medium The speed of light in a medium increases with decreasing density and decreases with increasing density Thus, Nd increases with increasing temperature (lower density) and decreases with decreasing temperature (higher density) Measured values of nD are adjusted to a standard 20oC. Read the room temperature using the thermometer attached to the instrument or use the one in your set.
Correction Factor = t * 0.00045 = (Rm Temp on 20) * slide) (Cont next
17
04/11/13
If temp > 20oC then t is positive - correction factor is added If temp < 20oC then t is negative - correction factor subtracted
is:
Ex: For 1.5500 an observed of 1.55231.5580 at 25oC, the correction 1.5523 value 1.5550 1.5600
Instrument is read to 4 decimal places The value corrected for temperature is: nD20 = nDrm temp + t (0.00045) t = Room Temp - 20.0oC nD20 = 1.5523 + (25 20)*(0.00045) = 1.5523 + 0.00225 =
04/11/13 18
IR Spectrum
Salt Plate Preparation 1 to 2 drops of liquid sample are placed between two single crystals of sodium chloride (Salt Plates) Note: not use plates
Solid Samples soluble in Acetone Dissolve sample in acetone Evaporate on Salt Plate Make Potassium Bromide (KBR) pellet
19
04/11/13
IR Spectrum
Place Salt Plate sandwich into base of Plate Holder Place Plate Holder top over base and press down Instructor - At the start of session enter new background Student - Insert Plate Holder into beam slot Select Memory location (X, Y, or Z)
20
Obtain Spectrum
04/11/13
IR Spectrum
04/11/13
21
Spectroscopy Experiment (NMR) When the Scan box in lower right corner
indicates Ready, press Plot to produce chart Remove Cell Holder Clean & dry Salt Plates with Acetone Place in desiccator, replace desiccator cap
An NMR Spectrum of your unknown will be handed out during the laboratory session. Summarize the principal NMR peaks in the :
Results section of the report opposite the procedure description The Results Summary Section
Analyze the NMR spectrum as part of the Analysis & Conclusion section
22