Distillation Modeling

CHEN 4470 Process Design Practice


Dr. Mario Richard Eden Department of Chemical Engineering Auburn University
Lecture No. 13 Design of Overhead Condensers and Air-cooled HX February 16, 2012 Material Developed by Dr. Jeffrey R. Seay, University of Kentucky - Paducah

Overview
Purpose of Overhead Condensers
Provide reflux flow to the top of a column and acts as an additional theoretical stage above the trays/packing

Types of Condensers
Knock-back reflux Total condenser Partial condenser

Proper condenser design is critical to the optimum operation of a column!

Knock-Back Condenser
This design is easy to operate, but difficult to achieve precise control. Condenser will be larger due to the bi-directional traffic on the process side.
2-Phase Flow Region

Condenser can be in the vertical or horizontal position.


- Horizontal Process on the shell side. - Vertical Process is on the tube side. Elevation is critical.

Partial Condenser
Vapor Distillate

Used when vapor product is required, or if non-condensible gases are present in the overhead product. Controlling the vapor stream split can be challenging. Condenser can be in the vertical or horizontal position. - Horizontal Process on the shell side. - Vertical Process is on the tube side.
Liquid Distillate

Elevation is not critical.

Total Condenser
Total condensers are used when no non-condensable gases are present. As with other condensers, vertical or horizontal operation is possible. Elevation is not critical for a total condenser. Subcooling of the reflux can be a problem with overhead condensers, especially with vertical designs.

Liquid Distillate

Condenser Design
Considerations
The overhead condenser is often a critical part of the control concept of a column Because distillation is based on VLE principles, the overhead condenser can be used to control the temperature and pressure in the column A later lecture will present some control concepts and strategies for overhead condensers Condensers in series can also be used to optimize utility consumption

Condensers in ASPEN Plus

Air-Cooled Heat Exchangers


Typical Air-Cooled Condenser
Process Out

Process In

V FD

V FD

Tube Detail

Design Equations:

Cp (TAir ,out TAir ,in ) Q U A Tlm m


U
1 k C Re m Pr 3 OD

Air-cooled HX are primarily used when no other cooling utilities are available on site

Note:

The surface area, A, includes the area of the fins! C and m are parameters based on the size of the fin.

Air-Cooled HX Design
Design Considerations
Natural convection in turndown cases Changing ambient air conditions Effect of precipitation on operation of unit Possibility of water-hammer inside tubes

Possible Control Parameters


Air flow across the tube bank Position of louvers on top of the unit Liquid level inside the tubes