IT IS DIODE WHICH EMITS LIGHT OF REQUIRE COLOUR WHEN FORWARD BIASED

DOPING MATERIAL, WAVELENGTH AND OPERATING VOLTAGE FOR COLOUR EMITTED BY LED

Colour

Wavelength

Voltage

Semiconductor Material Aluminium gallium arsenide (AlGaAs) Gallium arsenide phosphide (GaAsP) Aluminium gallium indium phosphate (AlGaInP) Gallium(III) phosphide (GaP) Gallium arsenide phosphide (GaAsP) Aluminium gallium indium phosphide (AlGaInP) Gallium(III) phosphide (GaP) (AlGaP) Indium gallium nitride (InGaN) / Gallium(III) nitride (GaN) Gallium(III) phosphide (GaP) Aluminium gallium indium phosphide (AlGaInP) Aluminium gallium phosphide

RED

610 < < 760

1.63 < V < 2.03

Yellow

570 < < 590

2.10 < V < 2.18

Green

500 < < 570

1.9[< V < 4.0

WHAT IS LED SIGNALS?


IT IS REPLACEMENT FOR FILAMENT LAMP WITH LOT OF ADVANTAGES OVER DRAWBACK OF FILAMENT LAMP
Aspect control circuit with LED signal arrangement Relay room
Fuse 0.63 Amp MOTHER BOARD & HMU CARD UNDER GROUND CABLE

CLS Unit
AC I/P

BX110 V AC NX110 V AC

ECR
DC I/P

OTHER SELECTION UNIVERSAL CURRENT REGULATOR LED SIGNAL UNIT

Comparison between filament lamp & LED circuit


Aspect control circuit arrangement with filament lamp & LED signal
RELAY ROOM Fuse 0.63 /2 Amp UNDER GROUND CABLE CLS UNIT

BX110 V AC

ECR

NX110 V AC OTHER SELECTION MOTHER BOARD & HMU CARD

Fuse 0.63 Amp

AC I/P

BX110 V AC NX110 V AC

ECR
DC I/P

OTHER SELECTION UNIVERSAL CURRENT REGULATOR LED SIGNAL UNIT

ADVANTAGES OF LED SIGNALS


Long life 1,00,000 hours Pre-focused Better visibility Very good short view No focusing on curved track Same type of ECR for all aspect and signal No phantom effect

NO PHANTOM EFFECT

Signal with LED lamp & door open

Signal with Filament lamp & door open

NO FOCUSING REQUIRE

WHETHER LED EMITS NOMINATED COLOUR ONLY?

A good quality LED emits nominated colour only There is very remote possibility that it may emits wrong colour if biased current changes

COMPONENT OF LED SIGNAL


FUSE LAMP CHECKING RELAY (ECR) HEALTH MONITORING UNIT (HMU) UNIVERSAL CURRENT REGULATOR LED SIGNAL UNIT

COMPONENT OF LED SIGNAL

Fuse

Health monitoring unit

LED signal lighting unit

Lamp checking relay ECR

Universal current regulator

FUSE TO BE USED WITH LED SIGNALS


Fuse shall be 0.63 Amps capacity Whether fuse of 0.63 capacity is available in ND type open fuse?

ND type open fuse

G type closed fuse

HEALTH MONITORING UNIT

Front View

Rear View

RELAY COMPATIBLE WITH LED SIGNALS

Any type of relay recommended (metal to carbon/ metal to metal )by Railway board can be use There is a recommended ECR for LED signal The selection of jumper on the UCR shall be as per ECR used.

RELAYS TO USED WITH LED SIGNALS


Sr No Type of ECR b ON-Metal to Metal OFF-Metal to Metal Make M/s ABB M/s Siemens M/s CGL Compan y code QECX51 HRC-1 ON-Metal to Carbon 180&110 ma M/s HMCR-1 Hytronic s
Suitability with LED signal

C- Rout Shu ON e nt YES YES


YES YES -

Mai n

P-up & DA current 180&110 ma 145&62ma 180&110 ma

Relay Contacts 3F/3B 3F/3B front 2,12,13 & back 3,4 ,14 4F/B, front A1/A2 to D1/D2 Back A3/A4 toD3/D4 4F/B ,front A1/A2 to D1/D2 Back A3/A4 toD3/D4 3F/3B ,Front A1/A2,D1/D2 & D3/D4 Back A3/A4, A5/A6 &D5/D6 4F/B , front A1/A2 to D1/D2 Back A3/A4 toD3/D4 4F/B , front A1/A2 to D1/D2 Back A3/A4 toD3/D4

YES YES YES YES

108/110ma

LED AC ECR-Metal to carbon LED DC ECR-Metal to carbon Conventional ECR

QECX61 QECR2 YES YES YES YES 80 &55ma YES YES YES YES 108 & 72 ma

Rest conventional ECR are not suitable for LED signal Reference RDSO Latter Nob .STS/E EL-LED Dated 02.06.2006

COMPONENT OF LED SIGNAL LIGHTING UNIT

Quality LEDs

Sensors

Poly-carbonet Dom

Power supply socket

Feed back socket

INPUT POWER SUPPLY, OUT PUT & FUNCTIONS


Input to all type of LED signal unit is 25% of 110 volts DC Input to LED signal unit for main aspect is taken from O/P of current regulator O/P is beam nominated colour (110 Lux for OFF aspect & 120 Lux for ON aspect) Also gives feed back about light O/P to current regulator if sensors are provided

INPUT POWER SUPPLY, OUT PUT & FUNCTIONS


Sr No LED signal unit Function gives out red light beam gives out yellow light beam In put & connectio n Out put Minimu AC Immunity m Visibilit AC I/P DC I/P y

RED Main runnin g signal YELLOW

GREEN 2 3 4 Directional route indicator Calling ON signal Shunt signal

gives out green light beam

Optical output Feedback to current regulator ( if sensors are provided

120 lux DC & 15% +25% appro. 600Mts 125% of AC Input of 110 lux noise 300 current immuni volts 15% +25% regulator ty 60 AC & current 50 lux -15% 400Mts Volts regulation +25% 2% & 50 lux -15% Direct +25% 200Mts 30 lux -15% +25%

gives out lunar white light beam gives out yellow light beam gives out lunar white light beam

LED SIGNAL UNIT FOR MAIN SIGNALS


ON ASPECT RED FRONT VIEW OFF ASPECT YELLOW OFF ASPECT GREEN

REAR VIEW

WHETHER LED SIGNALS ARE AVAILABLE FOR MAIN SIGNAL ONLY ?

LED SIGNAL UNIT FOR ROUTE INDICATOR

LED SIGNAL UNIT FOR SHUNT SIGNAL

LED SIGNAL UNIT FOR CALLING ON SIGNAL

WHETHER LED LIGHTING UNIT IS FOR MAIN SIGNAL ONLY?


LED SIGNAL UNIT FOR SUBSIDIARY SIGNALS
CALLING ON SIGNAL FRONT VIEW ROUTE INDICATOR SHUNT SIGNAL

REAR VIEW

I/P POWER SUPPLY, O/P OF CURRENT UNIVERSAL REGULATOR

It for main aspect only Placed inside CLS unit I/P 110 20 volts AC/DC O/P 125% of I/P & always DC O/P Current regulation 2 %

I/P POWER SUPPLY, O/P & FUNCTIONS OF CURRENT UNIVERSAL REGULATOR


Sr No Universal current regulator for Main running signal In put per unit current volts Out put Function AC 125 ma Separate 5% fixed in DC 105 ma CLS unit 5% AC 25 ma 5% DC 23 ma 5% Inbuilt AC 125 ma 5% DC 105 ma 5% AC 125 ma 5% DC 105 ma 5%

Directional route indicator

Calling ON signal

AC/DC 110 VOLTS 20%

Shunt signal

Supply constant regulate current to LED SIGNAL UNIT DC Scope for approxim adjustment of circuit ate current to suite pick 125% of up current of ECR I/P & Scope for adjustment current to suite cascaded and regulation non-cascaded aspect margin control circuit. 2% Regulates current as per feedback from LED signal unit

Note parameter as per specification RDSO/SPN/153/2002

I/P POWER SUPPLY, O/P & FUNCTIONS OF CURRENT UNIVERSAL REGULATOR


Sr No Universal current regulator for Main running signal Directional route indicator Calling ON signal Separat e fixed in CLS unit

In put per unit


current AC 140 ma +10,-20 (rms) DC 125 ma +10,-20 (rms) AC 25 ma 5% DC 23 ma 5% AC 150 ma +10,-20 (rms AC 125 ma +10,-20 (rms AC 55 ma 5% DC 50ma 5% AC/DC 110 VOLTS 20% volts AC/DC 110 VOLTS 25%

Out put

Function

Inbuilt

Shunt signal

Supply constant regulate current to LED SIGNAL UNIT DC Scope for approxim adjustment of circuit ate current to suite pick 125% of up current of ECR I/P & Scope for adjustment current to suite cascaded and regulation non-cascaded aspect margin control circuit. 2% Regulates current as per feedback from LED signal unit

Note parameter as per specification RDSO/SPN/153/2004 effective from 1.1.2007

PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT


Transformer 110/12 Volts 40 VA MECR (If provided ) Signal lighting unit Inner colour lens Outer Clear lens Lamp holder Lamp Clamp

PROVISION OF LED SIGNAL IN EXISTING FILAMENT LAMP CLS OUTDOOR ARRANGEMENT Items to be removed from CLS unit:
CLS Transformer & Lamp MECR (if provided) Lamp holder & clamp assembly inner & Outer lens

Items to be fitted:
Current Regulator LED light unit

PROVISION OF LED SIGNAL IN EXISTING FILAMENT LAMP CLS INDOOR ARRANGEMENT


Items to be removed/add from Relay room: Check 110 AC fuse, shall be 0.6 Amps ECR, if it is not as per RB guide lines If required Aspect monitoring card per Aspect of HMU

PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT

Signal lighting unit

PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT

Signal transformer

MECR

Inner colour & outer clear lens

Lamp, holder & clamp

FIXING OF LED SIGNAL UNIT & UNIVERSAL CURRENT REGULATOR

FIND OUT THE FAULT FIG -1 FIG -2

Can you interchange the led signal unit in CLS?

CHECKS- DURING REPLACEMENT LED SIGNAL IN EXISTING FILAMENT LAMP CLS


Fuse of Aspect control circuit shall be 0.63 amps Existing ECR & shall be as RB guidelines Make the jumper settings on UCR & HMU to suite ECR The availability/non-availability of cascading in Aspect control cct. Make the jumper setting (blanking/non-blanking) on UCR accordingly Check whether HMU is in circuit OR bypass mode