Deversity Faults

QUESTION??? I need help on how to tackle RX Diversity faults from RBS 2111 config 4/4/4 because it clears and then it comes back.what other procedure can i use so that it clears for good?. 8 avril 2011 -----------------------------------------------------------------------------ANSWERS !! * How you can configurate 444 on 2111 when in the OMT (and their capacity) is max 222? * Do you have configuration Master/Slave? * Do you have connected 2 feeders (TX/RX) in each sector or only one (TX)? * Do you use diplexer? * RX Diversity Lost and RX Path Imbalance alarm normally appear after 45min or 2hs. If you need to test if the alarm will appear without to wait 2hs, you need to down the time in "monitoring" RX Diversity (Mantenaince/Monitor/Rx Diversity) in the OMT. Pay attention: If you have connected only one feeder in the RBS, in BSC, you need to configurate RXD=A. If use diplexer, test the signal (without diplexer) on every freq and then set in OMT diplexer=YES. If use M/S configuration, check that free cross feeder. if the RX Diversity Lost are on sector 2 or 2&3, Im shure the problem is in BSC configuration. Chances are that the BSC guy configurated 2+2+2 with 2TRXs space, instead of 2+2+2 without intermediate space.

----------------------------------------------------------------------------ANSWERS !!!

I have 2111 master/slave with 2 feeders (TX/RX) in each sector without diplexer. Could you please give me more details about 2+2+2 with 2TRXs space & 2+2+2 without intermediate space?----------------------------------------------------------------------------ANSWERS !!!!
Hi Zineddine When you need to integrate a 2106/2206 as 222, normally the BSC guy integrate 222 with the following configuration: TRXs # 0&1 (sector 1) / # 4&5 (sector 2) / # 8&9 (sector 3). The physical hardware configuration (on RBS) can be with or without space becouse the relation is between cables connection and OMT configuration. In a 2111, the physical configuration is fixed and only it has capacity to 6TRXs, so, you need to configurate in BSC with TRXs from #0 to #5 (0&1--S1, 2&3--S2, 4&5--S3). This configuration is fixed on OMT and BSC. If the BSC guy did the configuration as 6102, the sectors 2 (and may be S3 too) will appear RX Diversity Lost. Always talking BSC data transcrip, for M/S configuration, you need to configurate 2 TG (one with TF=M, and other with TF=S) for each RBS 2111, with 6 TRXs (TRXs from #0 to #5) each TG, with 2 TRXs each sector. I hope this is the problem and their solution. Any question my skype user is psanmart01. Please if you add me, send me "Hi, Im linkedin contact". BR Pablo --------------------------------------------------------------------------------PROPOSE !! We had the same problem with RBS 2206, issue resolved when the CXU-10 changed --------------------------------------------------------------------------ANSWERS !!! There arent CXU in 2111. The TRXs config is fixed. (uncombined) -----------------------------------------------------------------------------

Thank You

Вам также может понравиться