Вы находитесь на странице: 1из 14

FactoryTalk View Site Edition

Building a better View

Official HMI of

Rev 5058-CO900D

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

Client Server Studio

Station

FactoryTalk View Site Edition


V7.0 Release Information

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

FactoryTalk View v7.0


Release January 2013
Information Integration
Network View SE Station TrendX support for FactoryTalk Historian ME FactoryTalk VantagePoint Trend Active X support

Process Industry Support


Expanded System Topology Limits ISA 18.2 Alarming Standard support for Shelving State Remote Tag Based Alarming Commands Navigation Button

Usability
Streamlined Installation Process Cross Reference / Find and Replace in View Studio Gradient Shading and PNG Support
Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 3

TrendX Support for Historian ME


Overview
FactoryTalk View SEs TrendX now supports showing historical data being collected by one or more FactoryTalk Historian ME Modules

Benefits
FactoryTalk View SE Distributed and Network
SE Station can directly monitoring data from Historian ME module.

Data from multiple FactoryTalk Historian ME


modules can be shown on one TrendX

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

FactoryTalk VantagePoint Trend

Overview
To gain better access to VantagePoint data, you can now use the VantagePoint v4.5 Trend ActiveX with FactoryTalk View SE 7.0

Benefits
All the power of the FactoryTalk VantagePoint
Trend from a FactoryTalk View SE Screen

Create new trends at runtime and publish back


into FactoryTalk VantagePoint model
Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 5

Expanded View SE Station Capabilities


Overview
Network View SE Station is a new application type selection for FactoryTalk View SE 7.0. Network View SE Station expands the capability of single HMI stations for security and data access. No new catalog numbers same Station license can be used

Network Scope FT

Benefits
Enables View SE Station to access Network
Scope products like FactoryTalk Historian ME and SE and FactoryTalk Batch Up to 20 Network SE Stations can be configured in one FactoryTalk Directory Can participate in a Network FactoryTalk Security strategy Supports off-box RSLinx Enterprise Data Server that can be configured for redundancy
Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 6

Historian SE

View SE Distributed

View SE Station

Simplified Installation Process


Overview
Brand new installation workflow that streamlines and simplifies the process of installing FactoryTalk View SE Systems

Benefits
Allows user to pick main role of the target
computer Provides list of mandatory and optional installation selections per the selected role Automates IIS installation, when required, on newer operating systems Once all information is entered, steps through the required order of installation automatically.

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

Answering the Call for Larger Systems


FactoryTalk A&E Clients
50 5 2

Redundant FT View SE Server Pairs

Redundant FTAE Server Pairs

2.5x
20

2x

10

5x

10

V6.1

V7.0 Overview

V6.1

V7.0

V6.1

V7.0

Benefits
Synchronizes architecture limits to simplify
decision making Expands the number of clients and servers using FactoryTalk Alarms and Events Removes architecture barriers to FactoryTalk Alarms and Events adoption

To meet the growing demand for larger systems, FactoryTalk View SE 7.0 has expanded past server and client limits allowed in one application

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

Improved Alarm Management


Overview
New Shelve buttons available on Alarm Summary
To align with ISA Standard 18.2, FactoryTalk Alarms and Events 2.60 will support the Shelved State.

Benefits
Enter shelve time duration and comments

Shelving an alarm is similar to suppressing an


alarm but with an expiration time. ISA 18.2 aligns suppress as a programmatic command that should not be exposed to an operator. Shelved provides the benefit of allowing user to better manage their alarm strategies, make adjustments, and operate much better.

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

Broadening our Alarming Capabilities


Issue alarm commands from Alarm Summary and Device Faceplates

Overview
FactoryTalk Alarms and Events 2.60 (CPR 9 SR 6) Tag Based Alarms allows HMI Faceplates to issue alarm commands without forcing the user to go to the alarm summary

Benefits
FTAE Tag Based Server

Further empowers PlantPAx faceplate


capabilities for all Tag Based Alarm Commands Remote Acknowledge was supported in 2.30 (CPR 9 SR 3) New commands supported: Shelve, Unshelve, Enable, Disable, Suppress, Unsuppress User can enter Logix tags for Status and Control tags to enable this capability

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

10

Improving Operator Effectiveness


Overview
To improve operator effectiveness, we introduce a new Navigation Button and Commands that function in a similar fashion to a Web Browsers Back, Forward, and History buttons

Benefits
Removes need for VBA scripting to track
screens Simplifies navigation strategies so users can quickly get to the screen they need Offers flexibility for choosing the screens you want to track and enter a user friendly name for display in history Supports touch friendly font sizes and language switching
Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 11

Increasing Design Time Productivity


Overview
FactoryTalk View Studio in 7.0 adds Find and Replace capabilities for Displays and Global Objects and a Cross Reference for finding tags throughout the system

Benefits
Find and Replace searches for Tags and
Strings located in objects on Displays and Global Objects Cross Reference can find tags and strings in the Tag Database, Displays, Global Objects, Parameter files, Macros, and Data Logs. When performing a Find All or Cross Reference, double clicking on one of the results will open the component and highlight where the tag is located
Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 12

Enhanced Graphic Look and Feel


Overview
FactoryTalk View SE 7.0 enables users to create better, more appealing graphics while still maintaining operator effectiveness with the new Gradient Shading capability and support for PNG graphic types.

Benefits
Improve the look and feel of native View SE
shapes, buttons, backgrounds, and more.

Add gradient shading in ways that enhances


HMI Screens but not to distract operator from tasks

PNG Graphic types better support background


transparency to make buttons stand out.

Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.

13

Questions?

Follow ROKAutomation on Facebook & Twitter. Connect with us on LinkedIn. www.rockwellautomation.com


Rev 5058-CO900C Copyright 2013 Rockwell Automation, Inc. All rights reserved.

Вам также может понравиться