Вы находитесь на странице: 1из 30

Inova Fairfax Hospital

South Patient Tower


Falls Church, VA

Penn State Senior Capstone Project Jianhong Qiu| Construction Management Advisor: James Faust

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM

Inova Fairfax Hospital


South Patient Tower
Falls Church, VA

I.
II. III. IV. V. III.

PROBLEM IDENTIFICATION
BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. IV. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM SCHEDULE ACCELERATION

BREADTH TOPICS DYNAMIC GLASS/ELETRICAL BREADTH MECHANICAL BREADTH

IV.

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. IV. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL ELECTRICALBREADTH DYNAMIC GLASS

V.

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD)

I.
II. III. VI. VII.

PROBLEM IDENTIFICATION
STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

Penn State Senior Capstone Project Jianhong Qiu| Construction Management Advisor: James Faust

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

PROJECT OVERVIEW
LOCATION: 3300 GALLOWS ROAD, FALLS CHURCH, VA FUNCTION: HEALTHCARE 174 PRIVATE ROOMS INTENSIVE CARE UNITS SIZE: 236,000 SQ. FT. 147.55 FT COST: 76MILLION $ DATE OF CONSTRUCTION : JULY 2010-AUGUST 2012 EDLIVERY METHOD: DESIGN-BID-BUILD
ORINIGAL SITE

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

PROJECT OVERVIEW
PROJECT PARTICIPANTS
OWNER: GERNAL

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

INOVA HEALTHCARE SYSTEM


CONTRACTOR: TURNER CONSTRUCION COMPANY WILMOT SANZ, INC.

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

ARCHITECT: MEP: CIVIL:

RMF ENGINEERING, INC. DEWBERRY & DAVIS LLC CAGLEY & ASSOCIATES TURLAND SERVICE CORPORATION

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

STRUCTURE: ELECTRICAL:

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 4

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

PROJECT OVERVIEW
STRCTURE:
CONCRETE STRUCTURE TWO-WAY FLAT SLAB

FAADE:
45,000 SF. ARCHITECTURAL PRECAST (INCLUDING 22,000SF. THIN BRICK-CLAD ) 282 METAL PANELS GLAZED INTO ALUINUM CURTAIN WALL

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

TYPICAL 24IN. X 24IN. COLUMNS


12FLOORS ABOVE GRADE /1FLOOR BELOW GRADE

SUSTAINABILITY:
LEED SILVER CERTIFICATION

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

MECHANICAL SYSTEM:
5TH FLOOR WITH 4X 5,000 CFM AIR HANDLING UNITS 2 AIR HANDER FOR CAFETERIA AND KITCHEN ON WEST ROOF OF 2ND FLOOR 10,000CFM AND 13,000 CFM 3 HEAT EXCHANGER IN BASEMENT (715 GALLONS/MINS )

GREEN ROOF, RAIN GARDEN

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

ELECTRICAL SYSTEM:
TWO 2,000KVA TRASFORMERS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

2,000KW EMERGENCY GENERATOR

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

AYALYSIS #1 IMPLEMENTATION OF BIM Problem Identification:


BIM NOT STRICTLY REQUIRED BY OWNER NOT USED TO FULL TENSION EXISTING BIM USES 3D COORDINATION OF MEP SYSTEM PREFIBRACATE MEP COMPONENTS

PROTENTIAL SOLUTIONS
INVESTIGATION OF BIM TOOLS BIM ROI BIM SCORE CARD

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. IV. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM SCHEDULE ACCELERATION

IV.

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY


I. II. III. IV. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL ELECTRICALBREADTH DYNAMIC GLASS

EXPLORE ADDITIONAL BIM USAGE

V.

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 6

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

AYALYSIS #1 IMPLEMENTATION OF BIM BIM RETURN ON INVESTMENT (ROI) ROI= EARNING/COST


REVIT ARCHITECTURE SOFTWARE SURVEY
A B C D E 6000 4200 3 50 25

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

(B-(B/(1+E))) X (12-C) = 1st Year ROI A+ ( B x C x D)


A: Cost of hardware and software($) B: Monthly labor cost($) C: Training time (Months) D: Productivity lost during training(%) E: Productivity gain after training(%)

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

(4200-(4200/(1+25%))) X (12-3) = 61.46% 6000+ ( 4200 x 3 x 50%)


SCHEDULE COMPRESSION BY 10%
7

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

AYALYSIS #1 IMPLEMENTATION OF BIM


BIM SCORECARD-DETERMINE HOW MANY BIM CAPABILITIES ARE USED IN OPERATION 7 CATEGORIES:
1.PORTFOLIO 2.COST 3.COST

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

AND PROJECT MANAGEMENT

IV.
IV.

SCHEDULE ACCELERATION

PLANNING

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

CONTROL
PLANNING CONTROL

4.SCHEDULE

5.PRODUCTION 6.DESIGN

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

COORDINATION

7.DESIGN

TEAM ENGAGEMENT

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 8

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

AYALYSIS #1 IMPLEMENTATION OF BIM


BIM SCORECARD
1.PORTFOLIO 2.COST 3.COST

REVIEW AREAS FOR IMPROVEMENT OPPORTUNITIES


COST PLANNING SCHEDULE PLANNING DESIGN TEAM ENGAGEMENT

AND PROJECT MANAGEMENT

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

PLANNING CONTROL PLANNING CONTROL

IV.
IV.

SCHEDULE ACCELERATION

4.SCHEDULE

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

5.PRODUCTION 6.DESIGN 7.DESIGN

COORDINATION
TEAM ENGAGEMENT

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 9

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

AYALYSIS #1 IMPLEMENTATION OF BIM


INVESTIGATION OF BIM TOOLS
VICO 5D MODEL SOFTWARE:
2D 3D 4D 5D

HOW DATA FLOW WORK

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

DRAWING CONSTRUCTABILITY AND COORDINATION SCHEDULING AND PRODUCTION CONTROL ESTIMATION AND COST PLANNING

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 10

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

AYALYSIS #1 IMPLEMENTATION OF BIM


FURTHER BENEFITS CASE STUDY
MIDDLE 555,000

INOVA FAIRFAX 2015 CAMPUS IMPROVEMENT PLAN

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

EXPENSION OF 600,000SF. WOMEN HOSPITAL


TENNESSEE MEDICAL CENTER SF. BUDGET SAVING

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

$3MILLIONS ADDITIONAL

$1MILLION SAVING DUE TO BIM ENABLED PREFABRICATION


COMPLETED

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

TWO MONTHS AHEAD OF SCHEDULE

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 11

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #2 SHORT INTERVAL PRODUCTION SCHEDULE(SIPS)


PROBLEM IDENTIFICATION

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

SIMILAR AND REPETITIVE FLOOR PLANS PATIENT ROOMS ALONG WITH WORKING SESSION IDENTIFY ROOM NUMBERS AND DIMENSIONS
FLOOR PLAN

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

POTENTIAL SOLUTION

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

IDENTIFY AREAS FOR NEW SIPS SCHEDULE


PREDESIGNED SMART ROOM CREATE NEW SCHEDULE
12

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

ANALYSIS#2 SHORT INTERVAL PRODUCTION SCHEDULE(SIPS) ORIGINAL CONSTRUCION FLOW

13

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS#2 SHORT INTERVAL PRODUCTION SCHEDULE(SIPS)


IDENTIFY AREA FOR SIPS:
RED

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

AREA FROM EAST TO SOUTH

IV.
IV.

SCHEDULE ACCELERATION

FLOW:

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

3,4,6,7,8

FLOOR MEDICAL/SURGERY ROOM


ICU BEDS

9-11FLOOR

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 14

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #2 SHORT INTERVAL PRODUCTION SCHEDULE(SIPS)

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

SCHEDULE ACCERLATOIN-SMART ROOM


PREDESIGNED MEDICAL CARE/SURGERY ROOM BY HILL-ROM FINALIZEINTERIOR ROOM LAYOUT 2D, 3D REDERINGS FOR CLIENTS

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 15

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #2 SHORT INTERVAL PRODUCTION SCHEDULE(SIPS)

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

SCHEDULE ACCELERATION
SUPERSTRUCTURE ABOVE CEILING MEP FAADE INTERIOR SAVING ONE MONTH AUGUST2011-JULY2011

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 16

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

Analysis #3 NET ZERO ENERGY BUILDING SUSTAINABILITY


PROBLEM IDENTIFICATION
OPERATE 24/7 HIGH COOLING,ELECTRICITY HOT WATER DEMANDS EMERGENCY BACKUP, OPERATIONAL DURING NATURAL AND OTHER DISASTER TIGHT CONTROL OF TEMPERATURE, HUMIDITY, VENTILATION. VARY AMONG DIFFERENT SPACE TYPES SPT GOAL: ENERGY REDUCTION 24.5 % BASED ON DATABASE OF SIMILAR BUILDINGS

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

DAY-TO-DAY OPERATION EQUIPMENT INTENSIVE, NO EFFICIENCY


RATING SYSTEMS FOR MEDICAL EQUIPMENTS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 17

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

Analysis #3 NET ZERO ENERGY BUILDING SUSTAINABILITY


NET ZERO ENERGY BUILDING CERTIFICATION REQUIREMENT:
CONSTRUCTION AND RENEWABLE ENERGY SYSTEM CURB THE PROJECTS CONTRIBUTION TO THE EFFECTS OF SPRAWLED DEVELOPMENT THE BUILDING OPERATES AT NET ZERO ENERGY

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

NATIONAL RENEWABLE ENERGY LABORATORY(NREL)


DEFINITION SUGGESTED BELOW TO DEFINE NET ZERO ENERGY: NET ZERO SITE ENERGY

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

NOT PRECLUDE ANOTHER BUILDING


ATTRACTIVE AND INSPIRING

NET ZERO SOURCE ENERGY


NET ZERO ENERGY COSTS NET ZERO ENERGY EMISSIONS

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 18

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

Analysis #3 NET ZERO ENERGY BUILDING SUSTAINABILITY

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL CHILLED BEAM PASSIVE/ACTIVE/MULTI-SERVICE COMBINED HEAT AND POWER(CHP) SOLAR ELECTRIC

IV.
IV.

SCHEDULE ACCELERATION

UTILITY BILL: PRODUCED VS. USED ADD UP MONTYLY READINGS OF ONE YEAR EXTRA ENERGY: SELL BACK TO UTILITY COMPANIES FIXED PRICE

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

ROOF/GROUND/MOUNTED FACING SOUTH


NO SHADE 9:00AM-3:00OM DECEMBER 2-4% NET COST
19

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

PRESENTATION OUTLINE: I. PROJECT OVERVIEW II. I. ANALYSIS IMPLEMENTATION OF BIM PROJECT#1: OVERVIEW I. PROBLEM IDENTIFICATION ANALYSIS #1: IMPLEMENTATION OF BIM II. I. III. II. IV. III. V. IV. III. BIM SCORECARD ENERGY REDUCTION STUDIES BIM ROI LAYOUT AND DESIGN SYSTEM INVESTIGATION OF BIM TOOLS STRUCTURAL IMPACT CASE STUDY AND FEASIBILITY ENERGY IMPACT

II.

Analysis #3 NET ZERO ENERGY BUILDING SUSTAINABILITY BREADTH TOPIC: DYNAMIC GLASS
THE FAADE DESIGN TOOL 4A MIXED HUMID CLIMATE

DESIGN PARAMETERS:

WINDOW AREA/DAYLIGHTS CONTROLS /


SHADING/GLASS&FRAME TYPE

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) V. FINANCIAL FEASIBILITY I. PROBLEM IDENTIFICATION II. IDENTIFY AREA FOR SIPS I. CASE STUDIES III. SMART ROOM II. INITIAL PREFABRICATION PLANNING IV. SCHEDULE ACCELERATION III. SCHEDULE AND COST REDUCTION ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY IV. SCHEDULE COMPRESSION I. PROBLEM IDENTIFICATION V. MODULAR DESIGN II. NZE BUILDING CERTIFICATION III. TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL I. BIM EXECUTION GUIDE IV. ELECTRICALBREADTH DYNAMIC GLASS II. CASE STUDIES ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) III. OPTIMAL DETERMINED USES I. PROBLEM IDENTIFICATION IV. VIRTUAL MOCK-UPS II. STUDY ON IPD GUIDE

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS)

IV.

IV.

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY

V.

V. VI. VI.
VII. VII.

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) III. MULTI PRIME CONTRACTS SUMMARY AND CONCLUSION SUMMARY AND CONCLUSION
ACKNOWLEDGEMENTS ACKNOWLEDGEMENTS 20

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

BREADTH TOPIC: DYNAMIC GLASS

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

IV.
IV.

SCHEDULE ACCELERATION

SOUTH FACADE

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS

EAST FACADE

WEST FACADE

21

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

Analysis #3 NET ZERO ENERGY BUILDING SUSTAINABILITY

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

BREADTH TOPIC: DYNAMIC GLASS


DYNAMIC GLASS REDUCE VISUAL GLARE REDUCING COOLING HEATING USAGE BY 20% REDUCING PEAK LOAD BY 30% COST:20$ / SF.

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 22

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

BREADTH TOPIC: DYNAMIC GLASS

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

TOTAL ENERGY SAVING= 31,789,200kBTU x 25%= 7,947,300kBTU TOTAL COST SAVINGS=7.9473 x 1000 x 35.16= $ 279,427 SOLADIGM INC. $20 /SF TOTAL COST= $20/ ft2 x 22450 ft2 = $449,000

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 23

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #4 INTEGRATED PROJECT DELIVERY (IPD) PROBLEM IDENTIFICATION


COMPLEXITY OF MEP SYSTEM:
MORE THAN ONE YEAR BIM COORDINATION NO EARLIER CONTRIBUTION TO DESIGN PHASE AND COORDINATION PROCESS EAST ELEVATION EXTERIOR WALL:

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

LIGHT GAGE METAL FRAIMING


REDESIGN TO COORDINATE BETTER WITH WOMENS HOSPITAL

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

REVISED ENGINEERING DRAWINGS


PREPARED BY FRAMING SUBCONTRACTOR.

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 24

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #4 INTEGRATED PROJECT DELIVERY (IPD) PROBLEM IDENTIFICATION


SOUTH ELEVATION :
1ST AND 2ND FLOOR CURVED WALL CURVES NOT MATCH ARCHITECTURE AND ENGINEERING DRAWING MISTAKES SCHEDULE DELAYED

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 25

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY
Team

ANALYSIS #4 INTEGRATED PROJECT DELIVERY (IPD)


STUDY ON INTEGRATED PROJECT DELIVERY A Guide(AIA)
Items Traditional Project Delivery Fragmented, minimumnecessary basis, strongly hierarchical Integrated Project Delivery Mutual Respect and Trust

ABILITY TO CHANGE DECREASE COST OF CHANGES INCREASE IPD PUT MORE EFFORT IN PREDESIGN/SCHEMATIC DESIGN PHASE

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

IV.
IV.

SCHEDULE ACCELERATION

Compensation/re ward

Individually pursued

Mutual Benefit and Reward

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

Risk

Individually managed, possible

Collaborative Innovation

transferred to the greatest extent and Decision

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS


Process

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

linear, segregated,information hoarded.

Early Involvement of Key Participants, goal Definition, Intensified Planning

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS


Communication Paper based,2 dimensional Digital based, BIM, Open Communication

26

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #4 INTEGRATED PROJECT DELIVERY (IPD) RISKS:


TRYING

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

MOST IDEAL WAY TO ACHIEVE IPD


COMBINE ALL NEW TECHNOLOGIES BIM LEAN SUSTAINABILITY

SOMETHING NEW AND UNTESTED WITHOUT A GMP

IV.
IV.

SCHEDULE ACCELERATION

BUILDING OWNER

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

TAKING RISKS BACK


TO MEASURE THE BENEFIT

DIFFICULT

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 27

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

ANALYSIS #4 INTEGRATED PROJECT DELIVERY (IPD) MULTI PRIME CONTRACTS

DIVISION OF CAPITAL ASSET MANAGEMENT OF COMMONWEALTH OF MASSACHUSETTS FREQUENT MEETINGS SHARING SENSITIVE, PROPRIETARY OR CONFIDENTIAL

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

INFORMATION
SELECT AND BUILD STRONG IPD PROJECT TEAMS MASTER KEY COMPONENTS OF CONTRACTS AND RISK

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

MANAGEMENT
UNDERSTAND ECONOMIC AND MARKET FACTORS THAT ARE DRIVING IPD ADOPTION

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 28

I. II.

PROJECT OVERVIEW ANALYSIS #1: IMPLEMENTATION OF BIM I. II. III. IV. V. PROBLEM IDENTIFICATION BIM SCORECARD BIM ROI INVESTIGATION OF BIM TOOLS CASE STUDY AND FEASIBILITY

SUMMARY AND CONCLUSION

III.

ANALYSIS #2: SHORT INTERVAL PRODUCTION SCHEDULES(SIPS) I. II. III. PROBLEM IDENTIFICATION IDENTIFY AREA FOR SIPS SMART ROOM

ANALYSIS#1INCREASE IMPLEMENTATION OF BIM


SCHEDULE/COST PLANNING ANALYSIS#2 SIPS ACCELERATE SCHEDULE PREDESIGNED SMART ROOM

ANALYSIS#3 NET ZERO ENERGY INCREASE BUILDING ENERGY EFFICIENCY ANALYSIS#4 INTEGREATED PROJECT DELIVERY ELIMINATE BARRIERS INCREASE PRODUCTIVITY

IV.
IV.

SCHEDULE ACCELERATION

ANALYSIS #3: NET ZERO ENERGY BUILDING SUSTAINABILITY I. II. III. PROBLEM IDENTIFICATION NZE BUILDING CERTIFICATION TOP STRATEGIES FOR ENERGY EFFICIENT HOSPITAL

IV.
V.

ELECTRICALBREADTH DYNAMIC GLASS

ANALYSIS #4: INTEGRATED PROJECT DELIVERY (IPD) I. II. III. PROBLEM IDENTIFICATION STUDY ON IPD GUIDE MULTI PRIME CONTRACTS

VI. VII.

SUMMARY AND CONCLUSION ACKNOWLEDGEMENTS 29

ACKNOWLEGEMENTS
PENN STATE AE FACULTY ADVISOR: JAMES FAUST CRAIG DUBLER TURNER CONSTRUCTION: TESSA R. TEODORO JOHNNY F. WEAVER DREW KELLEHER VICO SOFTWARE INTEGRATING CONSTRUCTION: HOLLY ALLISON

PACE INDUSTRY MEMBERS


MY FAMILY AND FRIENDS

30

Вам также может понравиться