The parameter about FACH

Parameter
hsDschInactivityTimer = 2
Time after which a connection with low throughput is
downswitched from HS-DSCH to CELL_FACH.
inactivityTimer = 30
When both the downlink and uplink throughput have
been 0 kbps (no data has been transmitted) for this
length of time, a downswitch from CELL_FACH to IDLE
state is requested.
The Analysis Of Data
The timer was modified from 30s to 5s.

The adjustment was done in TM01R on 5
th
June.

According to the chart, the PS DCR made improvement
obviously, especially Fach DCR.
The Analysis Of Data
The FACH and PS Drop Rate: