Вы находитесь на странице: 1из 29

Calibration Certificate

Config
7/25/2014 1
Create Material
7/25/2014 2
Change Class
7/25/2014 3
Classification
7/25/2014 4
Certificate Profile
7/25/2014 5
Define Certificate Types
7/25/2014 6
Config
7/25/2014 7
Create Certificate Profile Initial screen
7/25/2014 8
Create Certificate Profile-Header data
7/25/2014 9
Create Certificate profile-Header data
7/25/2014 10
Create certificate profile-Characteristic
Data
7/25/2014 11
Create certificate profile-Characteristic
Data
7/25/2014 12
Header data
7/25/2014 13
Profile Assignment
7/25/2014 14
Assignment type
7/25/2014 15
Create Certif. Assgn.Type
7/25/2014 16
Assignment
7/25/2014 17
Control Data
7/25/2014 18
Access Sequence
7/25/2014 19
Change Accesses
7/25/2014 20
Print Cert
7/25/2014 21
Print Certificate
7/25/2014 22
Print Certificate
7/25/2014 23
Print Certificate
7/25/2014 24
Print result in quality certificate for characteristics from routine
For printing of Quality certificates there are several options available:
like BATH, Inspection lot and deliveries.
As if u choose any options then u need to define the output types,
certificate profile and certificate type. In certificate profile you need to
assign the layout or say smart form where exactly u need to print your
characteristics and in that print program you need to defined the logic
for fetching of characteristics from referred routing but be cautious
your logic will be more clear. Secondly in certificate profile you just add
all you MIC's along with appropriate selection fields and provide logic
to fetch them on certificate accordingly.
Maintain proper values in profile like Insp specification origin, result
origin, result value etc. and provide assignments its works. and if
needed take help of a technical person.
http://boardreader.com/fp/Places_SCN_318809939/SAP_ERP_Operations_Q
uality_Management_SA_182343746.html
http://scn.sap.com/docs/DOC-50928


7/25/2014 25
Test Equipments Certificates For This Equipment
How do you calibrate a reference equipment -->
when the test passed --> the equipment is
calibrated for a certain period of time, for
example = 1 year.
This information is needed to be register on
the test equipment for later used.
7/25/2014 26
Solution
The following steps are in accord to our business.

It will be good as reference for your own company.

1. Create Test Equipments ( IE01)

2. Create MIC ( Master Inspection Characteristic ) : for what
parameter you want to record results ( QS21 ).

3. Create a Maintenance Task List With Header.

- a. QM Data as --> 300 ( Inspection Point for a Equipment)

- b. Refer MIC ( Master Inspection Characteristic ) by Selecting
Inspection Characteristic Overview
7/25/2014 27
Solution
5. Create a Maintenance Plan with Test Equipment by
mentioning order Type as a Calibration Order ( IP01 ).

- (Give required Plan Parameters and cycle length etc.)

6. Attach the calibration Task List created earlier.

7. Schedule PM Order ( IP10 )

8. This will create a Maintenance Order Linked with
Inspection Lot.

9. Record Results and Do Valuation for the Equipment by
Using QA32 .
7/25/2014 28
Important QM Tables
http://www.erpgreat.com/quality/important-
qm-tables.htm
Transparent Table Relate With PM Module
http://www.erpgreat.com/plant/transparent-
table-relate-with-pm-module.htm
Transparent tables for WCM
http://www.erpgreat.com/plant/transparent-
tables-for-wcm.htm

7/25/2014 29