Вы находитесь на странице: 1из 38

LESSON 6

SUBSCRIBER LOOP
DESIGN
MOCK QUIZ
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the conventional subscriber loop.
Wire pair
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the maximum values for an
average-sized country for SLR.
16.5
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the principal parameter for
measuring the quality of a speech
connection
Loudness rating
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the minimum value of SLR.
- 1.5
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the current of talk battery.
36 mA
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the maximum values for an
average-sized country for RLR.
13
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is a function of the conductivity of
the loop conductor and its diameter or
gauge.
Signaling Limits
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the meaning of DSL?
Digital Subscriber
Line
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the reference frequency (Hz)
and the attenuation limit (dB) in North
America?
1000 Hz, 9 dB
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
Based on opinion results, what is the
best overall loudness rating (dB)?
5 to 15 dB
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What are the two variables/criteria to
be considered when designing a
subscriber loop?
(1) Maximum loop
resistance/signaling limit
(2) Maximum loss or
attenuation on the
loop/attenuation limit
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the pair of wire connecting the
subscriber to the local serving switch.
Subscriber Loop
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
Unique pairs of audio tones,
representing digits 1-0 are transmitted
to what serving equipment?
Exchange switching
equipment
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the American wire gauge that
has a diameter of 0.644 mm?
#22
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is defined as the loudness loss
between the speaking subscribers
mouth and an electric interface in the
network.
Send Loudness
Rating (SLR)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is the distance from the subscriber
subset to the switch/feed bridge. Also
the length of subscriber loop.
Loop length
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It refers to AC-loss at reference
frequency measured in decibels.
Attenuation Limits
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
This value is a function of the circuit
in the switch where the loop
terminates.
Maximum loop
resistance
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is a function of the IR drop of the
line.
Signaling Limits
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is a dc loop in that it is a wire pair
supplying a metallic path.
Subscriber loop
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the reference frequency (Hz)
and the attenuation limit (dB) in
Europe and other countries?
800 Hz, 6 dB
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It has been widely used loaded cable
in Europe for long-distance operation?
19H66
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is also known as the Resistance
Design Criteria.
Signaling Limits
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the inductance (in mH) of
24B88 loaded cable?
88 mH
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the American wire gauge that
has the smallest diameter?
#28 (0.032 mm)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is also known as Transmission
Design Criteria.
Attenuation Limits
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
24B88 loaded cable has load coils
inserted at how many intervals?
3000 ft or 915 m
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
The telephone dial that, when operated,
makes and breaks the direct current on the
closed loop, which indicates to the
switching equipment the ___________ with
which communication is desired.
Number (of the
distant telephone)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the American wire gauge that
has a diameter of 0.405 mm?
#26
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the American wire gauge that
has the largest diameter?
#19 (0.91 mm)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is defined as the loudness loss
between an electric interface in the
network and the listening subscribers
ear.
Receive loudness
rating (RLR)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What are the three most commonly
used load coil spacings?
B, D and H
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is a device that increases battery
voltage on a loop; extends signaling
range.
Range Extender
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is defined as the loudness loss
between the speaking subscribers
mouth and the listening subscribers
ear via a connection.
Overall Loudness
Rating (OLR)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
What is the formula for finding the DC
loop resistance?

=
0.1095

2

15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
It is defined as the loudness loss
between two electric interfaces in a
connection or circuit, each interface
terminated by its nominal impedance,
which may complex.
Circuit loudness
rating (CLR)
15 14 13
12 11
10 9 8 7
6 5
4 3
2
1
Inductive loading tends to reduce the
transmission loss at the expense of
amplitude-frequency response beyond
what frequency range?
3000 3400 Hz

Вам также может понравиться