Вы находитесь на странице: 1из 4

1

Single Door 10 cm
15 cm
back side of the product
Evaporation
ring position
TB001526
Title: Repair for gas leakage through the
evaporation ring Single Door Built-in
Affected products:
Single Door built-in of CARINARO (47)
Platform: Single Door Built-in
Factory: Carinaro (47)
S/N: ALL
Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work,
other than when undertaking specified observation checks.
Intervention to be done:
1) The product has been pressurized and internal leakage was
detected (Fig. 1). Leave the capillaries and the return pipe
disconnected from the compressor, because when the recovery
operation of the internal circuit will be completed, before carrying
out the vacuum and charging, the circuit cleaning should be
performed.
2) Looking at the back of the product, locate the position of the
evaporation ring at a height of 10 cm from the top and 15 cm from
the right side panel (see Fig.2 and Fig.3)
Fig. 1
Fig. 2
Technical Bulletin
What the Customer notes
Hot fridge
Problem Root Cause
No perfect sealing on the evaporation ring
A can of polyurethane foam

C00058201 RING LOKRING 5/2 NRMS00

C00143875 ALLOY FOR WELDING CU/AL DIAM.2X50
Spare Parts to be used
Profile: General
Issued: September 2014
Written by: F.L.
Approved by: P.U.
Revision: 02
2
Ensure that the appliance is disconnected from the MAINS
SUPPLY before carrying out any work, other than when
undertaking specified observation checks.
Intervention to be done:
3) Starting from that point, make an opening of 10x10cm. Do not cut
the plastic panel from all four sides, but leaving a hooked portion
so as to close again as shown in Fig 4.
4) Free the ring from the foam so you can make the repair (Fig. 4)
5) Cut the aluminum tube no more than 2 cm from the ring, and cut
the capillary (Fig. 5 and Fig. 6)
6) Pull down with a pliers the capillary so as to approach the latter to
the aluminum tube to do the repair (Fig. 7).

TB001526
Fig. 4
Fig. 6
Fig. 5
Fig. 7
10 cm
10 cm
Fig. 3
15 cm
10 cm
Title: Repair for gas leakage through the
evaporation ring Single Door Built-in
Technical Bulletin
Affected products:
Single Door built-in of CARINARO (47)
Platform: Single Door Built-in
Factory: Carinaro (47)
S/N: ALL
Profile: General
Issued: September 2014
Written by: F.L.
Approved by: P.U.
Revision: 02
3
Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work,
other than when undertaking specified observation checks.
Intervention to be done:
7) You can perform the leakage repair in two ways:
with welding: insert the capillary inside the aluminum tube for
a maximum of 2 cm (Fig. 8 and Fig 9). Put a protective plate
behind the point to be welded to avoid causing damage to the
appliance (Fig. 10). Perform welding between copper and
aluminum using the alloy C00143875 (Fig. 11 e Fig. 12).

TB001526
Fig. 8
Fig. 9
Fig. 10
Fig. 11 Fig. 12
Title: Repair for gas leakage through the
evaporation ring Single Door Built-in
Technical Bulletin
Affected products:
Single Door built-in of CARINARO (47)
Platform: Single Door Built-in
Factory: Carinaro (47)
S/N: ALL
Profile: General
Issued: September 2014
Written by: F.L.
Approved by: P.U.
Revision: 02
4
Ensure that the appliance is disconnected from the MAINS SUPPLY before carrying out any work,
other than when undertaking specified observation checks.
Intervention to be done:
with lokring: put glue on both ends of the pipes and place the
lokring paying attention to align the same with the two pipes to
be connected. Clamp the connector (Fig. 13 and Fig. 14).
8) To reduce the noise produced during operation, noise due to the
expansion of the gas, you can apply soundproof material (C00306744 -
TEROSTAT 82) to the weld or to the lokring ring as shown in Figure 15.
Place the pipes back into the appliance.
9) To insulate the parts where the insulating material was removed, use
the foam caring to counteract the expansion of the polyurethane
foam, using properly secured jigs (made of cardboard, wood, etc.).
This contributes to a better density of the foam, as well as to avoid
that any foam leak may soil the cabinet (Fig. 16).
10) Apply some silicon to let the plastic panel previously opened adhere
well and close properly securing it with tape.
11) Replace the filter then weld it again.
12) Do an empty and recharge of the product.
TB001526
Fig. 13
Fig. 16
Title: Repair for gas leakage through the
evaporation ring Single Door Built-in
Technical Bulletin
Affected products:
Single Door built-in of CARINARO (47)
Platform: Single Door Built-in
Factory: Carinaro (47)
S/N: ALL
Profile: General
Issued: September 2014
Written by: F.L.
Approved by: P.U.
Revision: 02
Fig. 14
Fig. 15

Вам также может понравиться