Академический Документы
Профессиональный Документы
Культура Документы
Guide
ZTE University
Objectives
Fault classification
Common troubleshooting method
Fault Classification
Service fault
Transmission fault
Management and maintenance fault
Hardware fault
Service Fault
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
Check the current alarms and history alarms. If there are alarms
about RRU/FS/BPC board fault, reset, reboot, or change the faulty
board, and then the fault may disappear.
If there is transmission alarm, check whether the transmission
connections are reliable, the resistance is matching, and the
transmission bearer network quality meets the requirements.
If the check results show that the Node B configurations are normal,
check RNC configurations.
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
Transmission Fault
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]:
[Fault Phenomena]
[Troubleshooting]
Loop IMA link from the BTS optical terminal to the RNC
check whether the E1 TS is normal
Loop from the optical terminal to the BTS
Perform the loop test on the SDTA board
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
Log onto the CC board through the telnet and carry out
the dosFsShow /ROOT/ command to view the
remaining space of the FLASH disk, delete some files of
the previous specification package.
Carry out the cd /ROOT/sw1 or cd /ROOT/sw2
command to switch to the destination directory. Carry
out the ll command to display the version file in the
directory delete *.swv files under both directories
[Fault Phenomena]
[Troubleshooting]
Hardware Fault
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
[Fault Phenomena]
[Troubleshooting]
Check the configuration of the alarm input dry contact through the
OMCB,
Check whether there is alarm on the circuit breaker of the indoor
lightening protection box
Check the cable connecting the lightening protection box
Check the SA output cable
Check whether the SA board is loose in the slot
[Fault Phenomena]
[Troubleshooting]
RRU Abnormal
[Fault Phenomena]
RRU Abnormal
[Troubleshooting]