Вы находитесь на странице: 1из 44

ZXSDR Node B Troubleshooting

Guide
ZTE University

Objectives

To guide the troubleshooting of ZXWR RNS


(V4.00) NodeB faults
To introduce the analysis and troubleshooting
process of ZXWR RNS (V4.00) NodeB faults and
to give typical cases

Fault Classification and Troubleshooting


Method

Fault classification
Common troubleshooting method

Fault Classification

Service fault
Transmission fault
Management and maintenance fault
Hardware fault

Common Troubleshooting Method

In the order of hardware, configurations, and


protocol.

Hardware running normally


Configurations and software version correct
Service flow. According to the protocol stack structure
of the interface, from bottom layer to high layer.

From easy to difficult

Service Fault

Faults related to R99 service


DPA and UPA service faults

Faults Related to R99 Service- Cell Setup


Fails

[Fault Phenomena]

NBAP message displays that the cell setup fails.

[Troubleshooting]

Check the current alarms and history alarms. If there


are alarms about RRU/FS/BPC board fault, reset,
reboot, or change the faulty board, and then the fault
may disappear.
Check whether the cell configurations are consistent on
the RNC and Node B, especially CELLID, LOCALCELLID, CELL-POWER, and BAND.

Faults Related to R99 Service- RNC Initiates


Cell Deletion

[Fault Phenomena]

The RNC initiates the cell deletion.

[Troubleshooting]

Check the current alarms and history alarms. If there are alarms
about RRU/FS/BPC board fault, reset, reboot, or change the faulty
board, and then the fault may disappear.
If there is transmission alarm, check whether the transmission
connections are reliable, the resistance is matching, and the
transmission bearer network quality meets the requirements.
If the check results show that the Node B configurations are normal,
check RNC configurations.

Faults Related to R99 Service- CCH is Set up


and Deleted Repeatedly

[Fault Phenomena]

After the Common Transport Channel (CCH) is set up, it


is deleted soon. And then, the CCH is setup again.
Such case repeats continuously.

Faults Related to R99 Service- CCH is Set up


and Deleted Repeatedly

[Troubleshooting]

Check whether the transmission parameter


configurations are consistent on the RNC and Node B.
ATM transmission parameters:
ATM addresses are consistent on the RNC and Node B.
AAL2 state is normal.
PVC path bandwidth and path group bandwidth are limited.
IP transmission parameters:
Service IP address is configured correctly.
IP path bandwidth and path group bandwidth are limited.

Faults Related to R99 Service- UE Can Not


Register Normally

[Fault Phenomena]

The UE can not receive signals and can not register


normally.

[Troubleshooting]

Check whether the network mode of the UE is WCDMA.


Check whether the USIM is distributed
Check whether LAC and RAC configurations are correct.
Check whether the power configurations of all CCH are
normal.
Check whether RF connection in the cell of Node B is
normal and is consistent with actual connection.

Faults Related to R99 Service- UE Can Not


Perform Service Normally

[Fault Phenomena]

The UE can receive nice signals but can not perform


services normally.

Faults Related to R99 Service- UE Can Not


Perform Service Normally

[Troubleshooting]

Enable PMS and check whether the cell digital/analog


transmission power and the UL RSSI is normal, and
whether there are strong interferences from the outside.
Check whether RACH package is increased normally
Check whether the pilot detection threshold is normal.
Check whether the ratio of RACH data package and
FACH data package is normal
Check whether the parameter settings related to FACH
are correct
Check whether the cell radius settings are reasonable

DPA Service Faults- HSDPA Download Rate


is too Low or Drops Suddenly

[Fault Phenomena]

When HSDPA service is being downloaded, the rate is


too low.

[Troubleshooting]

Check whether the prescription of the (U) SIM card is


correct
Check the HSDPA cell configurations

DPA Service Faults- HSDPA Download Rate


is too Low or Drops Suddenly

Check whether there are too many HSDPA users in the


cell
Check whether the CQI reported is too low
Check whether the re-transmission proportion is normal
Check the times of cells scheduling
Try sending some data packages from RNC to check
whether the rate can reach the ideal rate

UPA Service Faults- HSUPA Upload Rate is


too Low or Drops Suddenly

[Fault Phenomena]

When HSUPA service is being uploaded, the rate is too


low.

[Troubleshooting]

Make sure that HSDPA serving is working normally


Check in the cell measurement, the difference between
first receiving bandwidth and second receiving
bandwidth should be about 3 db
Check the value of SIR in UE measurement

UPA Service Faults- HSUPA Upload Rate is


too Low or Drops Suddenly

Check whether the cell is overloaded


Check whether the value of UPH, HLBS, and TEBS in
UPA UE measurement is correct
Check whether the values of HarqFail, First
transmission error bit rate, Second transmission error
bit rate, and Third transmission error bit rate in UPA UE
measurement are too large
In QXDM, check whether the authorization is fluctuated,
whether UEs BLER is too large, whether there are too
many DTX, and whether the power of DPCCH is high

Transmission Fault

Ethernet transmission faults


E1/T1 transmission related faults
OMCB failed to access NodeB

Ethernet Transmission Fault- SCTP Link


Abnormality

[Fault Phenomena]

The alarm that SCTP is abnormal occurs

[Troubleshooting]

Check whether the hardware connections are normal


Check whether parameter configurations are correct
Check whether SCTP link is set up successfully

E1/T1 Transmission Faults- E1/T1 LOS Alarm

[Fault Phenomena]

The electric signal is lost. The receiving end can not


detect the line pulse or logic 1 during a period, so the
RNC reports LOS (Loss Of Signal) alarm. Usually, the
signals on the peer line can not be detected because
Rx end of the E1/T1 physical line is faulty.

[Troubleshooting]

Check the physical state of E1 line:


Check whether SA board is inserted stably.
Check whether E1 connector is loose.

E1/T1 Transmission Faults- E1/T1 LOS Alarm

Check whether the connector pins are intact, without


slant pins and broken pins.
Check whether the external connector of the E1 line is
damaged and whether it is good contact with the peer
end.
Check whether the layout of E1 transmission cable
complies with the engineering specifications and
whether there is force from the outside.
Use the E1 self-loop line to loop the faulty line. If the
alarm resumes, check the E1 line on the peer end.

E1/T1 Transmission Faults- E1/T1 Remote


Alarm Indication

[Fault Phenomena]

RAI (Remote Alarm Indication) is detected by the local


end.

[Troubleshooting]:

If Tx end sends the line fault alarm or the link is


disconnected, check whether Tx line connection is
normal (refer to E1/T1 LOS alarm).
Check whether E1 frame structure matches. Check
whether both ends of the line are working in the same
mode, dual-frame mode or multi-frame mode.
Check whether there are a great number of error codes
on the Tx line.

E1/T1 Transmission Faults- E1/T1 LIF Alarm


of Near-End Receiving Link

[Fault Phenomena]

On the NM, the IMA link state is available on the near


end and unavailable on the far end.
Sscop signaling link connection disconnected (514)
E1/t1 Ima group is in non-working state (508)

[Troubleshooting]

Loop IMA link from the BTS optical terminal to the RNC
check whether the E1 TS is normal
Loop from the optical terminal to the BTS
Perform the loop test on the SDTA board

OMCB Failed to Access Node B

[Fault Phenomena]

When the OMCB accesses the Node B, it prompts the


failure or timeout.

[Troubleshooting]

Check whether the route from the PC to the RNC is


added correctly.
Check whether FTP server configuration is correct.
Check whether the route is added on the PC and OMM.
Check whether the Node B is enabled normally.
Check the firewall settings and see whether OMCB
connection is blocked.

Management and Maintenance Fault

Version load abnormality

Version Load Abnormality- Specification


Package Download Failure

[Fault Phenomena]

The specification package download fails

[Troubleshooting]

Log onto the CC board through the telnet and carry out
the dosFsShow /ROOT/ command to view the
remaining space of the FLASH disk, delete some files of
the previous specification package.
Carry out the cd /ROOT/sw1 or cd /ROOT/sw2
command to switch to the destination directory. Carry
out the ll command to display the version file in the
directory delete *.swv files under both directories

Version Load Abnormality- Specification


Package Activation Fails

[Fault Phenomena]

The specification package fails in activation and the


system prompts that there is data/software being
synchronized.

[Troubleshooting]

Wait until the standby CC board completes the software


synchronization. Check the current state of the standby
CC through the OMCB. If the state does not contain the
synchronous state, it indicates that the standby board
has completed the synchronization and the specification
package can be activated now.

Hardware Fault

Temperature related faults


Clock reference related faults
Lightening protection box alarms
RRU abnormality

Lightning Arrester Fault

[Fault Phenomena]

Alarm on the LMT interface: Lightning Arrester Alarm At


Indoor Lightning Protection Box (1536)

[Troubleshooting]

Check the configuration of the alarm input dry contact


in OMCB
Check whether there is an alarm on the indoor
lightening protection box
Check the connection cable that connects the external
alarm device on the equipment
Check the connection cable on the SA
Check whether the SA board is loose in the plug

Environmental Temperature is High

[Fault Phenomena]

Alarm on the EOMS interface: Environmental


Temperature is High (1500)

[Troubleshooting]

check whether the dustproof net is blocked


Check whether the equipment is BS8900
Check whether the air conditioner is normal in the
equipment room

Environmental Temperature is High

Choose EOMS maintenance navigator Ground


resources Environment monitor, set the value of
Upper limit as 50
Choose DMS Maintenance navigator Diagnosis and
Test Environment monitor information query, if the
value of Control layer inlet temperature is larger than
50, replace the FA (Fan Amplifier).

LOS Alarm on Ir Optical Port

[Fault Phenomena]

On the OMCB interface, there is the alarm:

On the LMT interface, there is the alarm: Ir optical port


has LOS alarm (Ir optical port ID: 2).

LOS Alarm on Ir Optical Port

[Troubleshooting]

On the LMT, check whether the RRU is configured in


the topo structure
Check whether the RRU is powered on
Exchange the receiving fiber and sending fiber on the
optical fiber on the FS interface board of the eBBUB
Use one standby optical fiber to connect the Tx and Rx
of the FS alarm optical port to perform the loop

LOS Alarm on Ir Optical Port

Make sure that the optical fiber on the RRU is


connected to the Optical port 1, not Optical port 2,
Make sure that the optical fiber is in good contact with
optical module on the RRU
Replace the standby fiber on the faulty RRU
Replace the optical module of the RRU

Clock Critical Alarm

[Fault Phenomena]

On the LMT interface, there is the alarm: Clock critical alarm


(AD9516 unlocked) and FS is performing soft reset repeatedly.

[Troubleshooting]

On the OMCB, check if , there is serdes clock alarm on the CC


board
Unplug and plug the CC board
Replace the CC board.
Unplug and plug the FS board
Replace the FS board
Insert the previous FS board into a normal shelf

Clock Reference Source Faults- BITS 2MBps


clock is degraded

[Fault Phenomena]

Clock Reference Source Faults- BITS 2MBps


clock is degraded

[Troubleshooting]

Check whether the interface connecting the E1 cable is


in good contact. If not, tighten the cable.
Check and replace the E1 cable.
Replace the SA and check whether the pins on the
backplane slot of the SA is bending or broken.
Check whether the external reference clock is normal.
Replace the CC board with alarm.

Clock Reference Source Faults- Internal GPS


clock reference is lost

[Fault Phenomena]

Clock Reference Source Faults- Internal GPS


clock reference is lost

[Troubleshooting]

Check whether the CC board supports the GPS.


Check whether the GPS lightening arrester or GPS
antenna is damaged.
Check whether the GPS feeder is connected nicely.
Check whether the clock reference source is configured
correctly.
Check and replace the GPS lightening arrester or GPS
antenna, especially check whether the GPS grounding
complies with the engineering specifications.
Check and replace the GPS feeder.

Indoor Lightning Protection Box Alarm

[Fault Phenomena]

On the LMT interface, there is the alarm: Circuit Breaker Alarm At


Indoor Lightning Protection Box(1537).

[Troubleshooting]

Check the configuration of the alarm input dry contact through the
OMCB,
Check whether there is alarm on the circuit breaker of the indoor
lightening protection box
Check the cable connecting the lightening protection box
Check the SA output cable
Check whether the SA board is loose in the slot

Outdoor Lightning Protection Box Alarm

[Fault Phenomena]

On the LMT interface, there is the alarm: Outdoor


Lightning Protection Box Alarm(1538)

[Troubleshooting]

Check the configuration of the alarm input dry contact


corresponding to the indoor lightening protection box
through the OMCB
Check the dry contact connector
Check whether there is an alarm on the indoor
lightening protection box
Check the cable with alarm
Check the RRU dry contact interface

RRU Abnormal

[Fault Phenomena]

The RRU can not be started or any of the following


alarm occurs:
Optical signal loss on the Ir optical port
RRU LOS/LOF alarm
Bottom-layer check error code on the Ir optical port

RRU Abnormal

[Troubleshooting]

Check whether the optical fiber and optical module are


intact and whether the connection of them is correct.
Check whether the optical module is 1.25 G as
prescribed
Check whether the FS board is normal
Check whether the topo structure is configured correctly