Scheme
Utilization of Electrical
Energ
TH
6 SEMESTER ELECTRICAL
Barjinder singh
ENGG.
Senior Lecturer Electrical
11/03/2013
Engg.
Government Polytechnic
College,
Guru Teg Bahadurgarh, Moga
Topics
1.
2.
3.
4.
5.
6.
7.
8.
9.
Introduction
Nature of light
Terms used in illumination
Law of illumination
Electrical methods of producing light
Sources of light
Arc lamps
Filament lamps
Gaseous discharge lamps
11/03/2013
Topics
10.Sodium vapor lamp
11.Mercury vapor lamp
12.Fluorescent tube
13.Neon lamp
14.Halogen lamp
15.Compact fluorescent lamp
16.Candle power and its measurement
17.Lighting scheme
18.Street light
19.Flood lighting
11/03/2013
Introduction
As we know that almost all human activities
depends on light. Sun is a prime natural
source of light but artificial lighting plays
almost main role in our daily life. These
artificial
lights
are
produced
by
mechanical lamps and electrical lamps.
But due to poor performance the
mechanical light are totally replaced by
electrical lights. The electrical lighting
are mainly used for decorative purpose,
advertising, traffic control , medical field
and street lighting etc.
11/03/2013
Electrical Lighting
Electrical
lighting
has
following
advantages :
1. Cleanliness
2. Easy to control
3. Economical
4. Easy to handle
5. Steady output
6. Better reliability
7. Suitable for almost all purposes etc.
11/03/2013
11/03/2013
light
That part of radiant energy
from a hot body which
produced
the
visual
sensation on human eye is
called light.
11/03/2013
Luminous Flux
The total quantity of radiant
energy
per
second
responsible
for
visual
sensation from a luminous
body is called Luminous Flux.
It is represented as F of and
measured in lumens.
11/03/2013
Lumen
It is the unit of luminous flux.
One lumen is defined as the
luminous flux emitted per
unit solid angle from a point
source of one candle power.
11/03/2013
Plane Angle
The angle subtended at a point by two converging lines lying in
the same plane is called plane angle. It is measured in radians and
equal to the ratio of the length of the arc too its radius,
= arc/ radius = l/ r radians
11/03/2013
Solid Angle
The angle subtended by the partial surface area of a sphere at its
centre is called as solid angle. It is measured in steradians and equal
to the ratio of area of the surface to the square of radius of sphere,
= area of surface/ square of radius = A/ r2 steradians
11/03/2013
Steradian
the unit of solid angle. One
steradian is defined as the solid
angle that is subtended at the
centre of a sphere by its surface
having area equal to radius
square,
= surface area/ (radius)2
= r 2 / r2 = 1 steradian
11/03/2013
Candle Power
The light radiating capacity of a
source is called its candle power.
The number of lumens given out by
a source per unit solid angle in a
given direction is called its candle
power. It is denoted by C.P.
Total flux emitted = CP X solid angle
= 1 X 4 = 4 lumens
= 4 lumens
11/03/2013
Luminous Intensity
Luminous
intensity
in
any
particular direction is the luminous
flux emitted by the source per unit
solid angle in that direction.
It is denoted by I and its unit is
candela or candle power (CP) .
Luminous intensity of source in a
particular direction, I = /
11/03/2013
Reduction Factor
reduction factor of a source of
light is the ratio of its mean
spherical candle power to its
mean horizontal candle power.
Reduction factor = MSCP/ MHCP
11/03/2013
Illumination
When light falls on a surface, it
becomes visible, the phenomenon
is called as illumination.
It is defined as luminous flux falling
on a surface per unit area. It is
denoted by E and measured in
lumen per square meter or metercandle.
E = / A lux
11/03/2013
Lux
One meter candle or lux is defined
as the illumination produced by a
uniform souce of one CP on the
inner surface of a sphere of
radius one meter.
11/03/2013
Glare
Lamp Efficiency
Lamp efficiency
The efficiency of fluorescent lamp is
more than tungsten lamp.
11/03/2013
Reflection Factor
Whole of the light incident on a
reflecting surface is not reflected.
Some portion of it is absorbed by the
surface.
The ratio of the reflected light to the
incident light is called reflection
factor.
11/03/2013
Law of Illumination
The illumination on a surface depends
upon the luminous intensity, distance
between the source and surface and
the direction of rays of light. It is
governed by following laws :
1.Inverse square law
2.Lamberts cosine law
11/03/2013
Lamberts Cosine
Law
This law states that the illumination on any surface is
proportional to the cosine of angle between the direction of the
incident flux and perpendicular to the area. E = 1/d 2 cos
11/03/2013
Electrical method of
producing Light
Following are the methods of producing
light :
1.By developing arc between two
electrodes
2.By passing a current through a filament
3.By electric discharge through vapors or
gases
11/03/2013
Arc Lamp
The principle of an arc lamp is that when
two electrodes carrying current are
separated through a small distance, an
arc is struck between them. The arc
lamps were used in the past for street
lighting purposes but now a day these
are used when extreme brightness is
required.
Most commonly use arc lamp is
Carbon Arc Lamp
11/03/2013
ARC Lamps
For maintaining the arc, a minimum voltage
required is given by :
V = (39 + 28 L ),
where
11/03/2013 L is length of arc in centimeter.
Filament or Incandescent
Lamp
Working Principle :
As we know when a room heater is
switched On , it gives out red light
with heat at the working temperature
of 750 oC and at this temperature the
radiations are mostly in infra red
regions. This working principle is
used to develop the filament lamp.
11/03/2013
Filament or Incandescent
Lamp
When an electric current is passed
through a fine metallic wire , it raises
the temperature of wire. At low
temperature only heat is produced but
at higher temperature light radiations
goes on increasing. As filament lamp
consists of fine wire of high resistive
material placed in an evacuated glass
bulb. This type of lamps are operated
at the temperature of 2500 oC .
11/03/2013
Filament Lamp
A tungsten filament is enclosed in evacuated glass
bulb but to improve its performance some chemical
like argon or nitrogen gas are filled.
11/03/2013
11/03/2013
11/03/2013
Fluorescent Tube
it is a low pressure mercury vapor
lamp. It consists of a glass tube 25
mm in diameter and 0.6 m, 1.2 m
and 1.5 m in length. The tube
contains argon gas at low pressure
about 2.5 mm of mercury. At the two
ends, two electrodes coated with
some electron emissive material are
placed.
11/03/2013
Fluorescent Tube
The colors produce by this tubes are as :
Material Color
Zinc silicate Green
Calcium tungsten Blue
Cadmium borate Pink
Calcium Holo phosphate White or day light
Magnesium tungsten Bluish white
11/03/2013
Fluorescent Tube
11/03/2013
Fluorescent Tube
Working :
A choke is connected in series with the
tube which act as a blast and provide a
high voltage at starting glow in the
tube. During running condition the
same choke absorbs some supply
voltage and remain a voltage of 110 V
across the tube. A capacitor is
connected to improve the power factor.
11/03/2013
Advantages of Fluorescent
Tube
11/03/2013
Disadvantages of
Fluorescent Tube
1. Its brightness is less.
2. Initial cost is more
3. Overall maintenance cost is high.
11/03/2013
Neon Lamp
These lamps are operated at a very low
temperature of about 200 oC thats why these
are called cold cathode discharge lamps.
Two electrodes are housed at the two ends of
the tube which contain neon gas. The
electrodes are made of iron or nickel cylinder
without any coating and practically they do
not emit electrons. It gives red light whereas
with mixture of mercury and argon it gives
bluish green color. Voltage require for starting
and operation is 10000 V. This high voltage is
obtained from transformer.
11/03/2013
Neon Lamp
Working :
When the supply is switched ON at primary side
of transformer, a voltage of 10000 V develops
across secondary side which come across two
electrodes. At this voltage a discharge occurs
in neon gas.
Different colors can be obtained by changing
the constituents of gases and mercury filled
in the tubes.
11/03/2013
Neon Lamp
11/03/2013
Neon Lamp
Applications :
Neon lamps are generally used for
advertising. Most of letters having
two ends at which electrodes are
placed. In letter having more than
two ends , the tube path is repeated
for some portion.
11/03/2013
Halogen Lamp
Halogen lamp is a special type of
tungsten filament lamp which was
developed in 1959, in this lams, a
small amount of halogen vapor is
added to the inert gas of the bulb. Its
glass bulb is small in size and
mechanically strong. It operates at
high temperature of 3000 oC .
11/03/2013
Halogen Lamp
When the supply is given to the lamp,
a filament glows and produce light.
The halogen in addition to inert gas
causes the evaporated tungsten to
resettle back on the filament during
cooling, thats why lamp can be
operated at high temperature.
It
provides high intensity light.
11/03/2013
Halogen Lamp
11/03/2013
Advantages of Halogen
Lamp
1.
2.
3.
4.
5.
6.
It is smaller in size.
It does not need any blast.
Good colors can be obtained.
Excellent optical control.
Gives same output throughout life
It has long life
11/03/2013
Disadvantages of Halogen
Lamp
1. During maintenance the handling of
lamp is difficult.
2. Radiant heat is more which heats
the surroundings.
3. Operating temperature is high which
effects its life.
11/03/2013
Compact fluorescent
Lamp( CFL)
It
Compact fluorescent
Lamp( CFL)
11/03/2013
Advantage of CFL
1.
2.
3.
4.
the
Applications of CFL
The compact size, longer life, low
running and maintenance cost,
instant glow makes these lamps
suitable for all places where
uniform illumination is required.
It is used in offices, shops, hotels,
hospitals,
cinema
halls,
residential buildings etc.
11/03/2013
Measurement of Candle
Power
The candle power of a source in
any
given
direction
is
measured by comparing it with
a standard or substandard
source with the help of an
optical
instrument
called
PHOTOMETER.
11/03/2013
Photometer
Photometers are mostly based on inverse
square law of illumination and may be
classified as stationary and portable
photometers.
The stationary photometers are usually
installed in a dark room with dead black
walls and ceiling in order to eliminate
error due to reflected light.
The portable photometers are direct
reading instruments used to measured
illumination
in
houses,
offices
,
commercial and industrial places.
11/03/2013
Lighting Schemes
Lighting
schemes
are
classified
according
to
the
location,
requirement and purpose etc. are as
under :
1. Direct lighting
2. Indirect lighting
3. Semi direct lighting
4. Semi indirect lighting
5. General lighting
11/03/2013
Direct Lighting
As is clear from the name, in this system
almost 90 to 95 % light falls directly on
the object or the surface. The light is
made to fall upon the surface with the
help of deep reflectors. Such type of
lighting scheme is most used in
industries and commercial lighting.
Although this scheme is most efficient
but it is liable to cause glare and
shadows.
11/03/2013
Indirect Lighting
11/03/2013
General Lighting
This system employs such type of
luminaries, shades and reflectors
which give equal illumination in all
the directions.
11/03/2013
Illumination Level
This is the most vital factor in deciding
the
number
and
wattage
of
luminaries so that we are able to see
and recognize the object properly.
Colors of the body have the property
of reflecting the light in different
proportions, degree of illumination,
its distance from the viewer, contrast
between the object to be seen and
its surroundings.
11/03/2013
Illumination Level
Type of work recommended illumination level
Offices 100-400 lumens/ meter square
Schools 250-400 lumens/ meter square
Industry 1000 lumens/ meter square
Shops 250-500 lumens/ meter square
Hotels 80-100 lumens/ meter square
Hospitals
250-3500 lumens/ meter square
11/03/2013
Quality of Light
This means that the illumination should
not be harmful to the viewers. It should
be glare free, shadow less and contrast
free. Direct glare from the source of
light is most common factor. Presence
of polished and glassy surface will
cause indirect glare unless diffused
light is used. Hard and long shadows
can be avoided by using a large
number of lamps and adjusting the
mounting height.
11/03/2013
Co efficient of Utilization
A surface to be illuminated receive light
either directly from the lamps or reflected
from the ceiling and walls or both. In this
case, the total flux reaching the surface
will never be equal to the flux emitted by
the lamp, due to absorption by reflectors,
ceiling and walls.
Utilization factor = lumens reaching at the working
place
total lumens emitted by the source
Usually it varies from 0.5 to 0.8.
11/03/2013
Depreciation Factor
The total flux emitted by the source
and its fitting may be reduced due to
deposition of dust upon the surfaces.
Similarly quantity of light reflected
from the ceiling and walls also
decreases with the passage of time.
This is called as depreciation facto.
Usually it varies from 1.3 to 1.6.
11/03/2013
Thank You
11/03/2013