5 X 660MW
SUPER CRITICAL UNIT
OPERATION EXPERIENCES
Presented by
BHASKARPRASAD
Subcritical Unit
Controlled Circulation
V/s
Supercritical Boiler
Features
There are two design
features utilized in boiler water
wall design for once through supercritical boilers
The spiral tube furnace arrangement:
Supercritical Boiler
The vertical Features
tube furnace arrangement:
The vertical tube designs are used for larger units with
internal ribbed tube to enhance heat transfer.
RIBBED TUBES
LTRH
Inlet HDR
Emergency DSH
LTRH
Outlet HDR
FRH
Inlet HDR
FRH
Outlet HDR
Micro flow
DSH
Eco
Inlet
Header
Storage
Tank &
BCP
Eco Header
Under LTSH
Eco Header
Under
LTRH
Vertical
Walls &
Upper
Header
Separators
Transition
Intermediate
Header & Walls
FSH
I/O
HDR
Eco HDR or
Hanger (F&R)
Under LTSH
Band
Platen
SH
Water
wall
lower
header
Butterfly panel
Back pass
F&R Wall
LTSH
I/O
HDR
Spiral
Water
walls
Eco
Hanger
Outlet
Back pass
O HDR
Divisional
Wall, Spacer
tube & Lower
HDR
Back pass
side walls &
Upper HDR
Divisional
Upper I/H
HRH
LINE
MS
LINE411
C,
SEPARATOR
G
C
O
N
D
E
N
S
E
R
LPT
S
T
O
R
A
G
IPT
HPT E
LPT
T
A
N
K
492C,
FUR ROOF
I/L HDR
411
C,
FINAL SH
FINAL
RH
DIV PANELS SH
LTRH
PLATEN
SH
VERTIC
AL WW
329C,
45Ksc
569
C,
571C,
254 Bar
ECO
JUNCTION
HDR
ECONOMISER
ECO I/L
al
r
i
Sp ter
wa lls
wa
FEED WATER
BWRP
FUR LOWER HDR
292C,
FRS
BURNER
FIRE
BALL
BURNER
Theoratical Arrangement
Benefits of Supercritical
Unit
16
Environmental Benefits
17
Boiler equipment
Super heater
:16080m2
Re heater
:24402m2
WW high temp :41290m2
WW intermediate:30054m2
WW low temp
:13095m2
sum :84439m2
Boiler
Boiler
Boiler
PERFORMANCE DATA
FUEL DATA
Gross as Received
3927 kcal/kg
Total Moisture
10 %
Ash Content
37 %
Volatile Matter
27.6 %
Fixed Carbon
25.4 %
Boiler Efficiency
Boiler
ESP
Boiler
Unit-operation
Boiler specification
NO.
Item
Specification
Unit
model
SG2111/25.4 M986
mode
2111
t/h
25.4
MPa
569
1749.1
t/h
4.73
MPa
4.49
MPa
324
10
569
Feedwater pressure
28.8
MPa.g
11
Feedwater temperature
280
12
421
153.3
147.2
13
14
87.19% BMCR
15
87.2% BRL
16
Pulverizing type
17
Burner type
18
Draft type
19
Design fuel
Indian coal
20
Check fuel
Indian coal
21
balanced ventilation
390.37
t/h
466.90
t/h
337.80
t/h
22
23
24
Important parameters to
control:
1. Water / coal ratio 7:1
2. OHDR- 20 to 30
3. Maintaining Pressure at SH and RH
- 25.4 & 4.45
4. Effect of Excess air
5. Water Chemistry
6. Tube metal temperatures
Difference in Operation
1. Boiler initial filling.
2. BCP filling and operation
3. Pressure and Temp rise rate w.r.t Metal temps.
4. Change in Boiler operation phases in Unit
operation
(Wet to Dry state, Subcritical once through to
super critical once through)
5. Boiler tube failures - identification
6. Chemistry parameters methods of chemical
treatment
7. Unit startup and Shutdown(dry to wet opn)
8. Additional Protections for Boiler