Вы находитесь на странице: 1из 76

OptiX RTN 600 Configuration

Using the T2000 and T2000 Web LCT

www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Foreword

Huawei provides NE-level, subnet-level and network-level

management systems for the RTN 600 series products.

This course describes the NE-level management system

OptiX iManager T2000 Web LCT and the subnet-level


management system OptiX iManager T2000.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 2

Reference

Digital Microwave Communication


principles

OptiX iManager T2000 Management


System Solution V2.31

OptiX iManager T2000 Web LCT


Installation Guide and User Guide

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 3

Objective
s

Upon completion of this course, you will be able to:


Describe the functions of the T2000 and the T2000 Web

LCT.
Install the T2000 Web LCT.
Configure services and protection by using the T2000

and the T2000 Web LCT.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 4

Contents
1.

Introduction to Networks
Management Systems

2. Introduction to T2000 Web LCT


3. Introduction to the T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 5

Comprehensive Management
System Solution
OSS or integrated
NMS

Integrated NMS & OSS

Service
management
layer

CORBA

CORBA

iManager T2100

MML

iManager T2000

iManager T2100
MML

CORBA

Network
management
layer

MML

iManager T2000

iManager T2000

NE
management
layer

iManager T2000
LCT

Qx

Qx

Qx

Qx

NE layer

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 6

Introduction to Management
Systems
The
orientation of each management system is as follows:

iManager T2000 LCT

iManager T2000

The iManager T2000 (T2000 for short) is a subnet management system


(SNMS) for transport networks. The T2000 manages the full series of
Huawei OptiX products. The T2000 supports all functions of the NE layer
and some of the network layer management functions.

iManager T2100

The T2000 local craft terminal (LCT) realizes the local maintenance and
equipment turn-up of Huawei OptiX products.

The iManager T2100 (T2100 for short) is a network-level management


system that uniformly manages the full series of Huawei OptiX products.
It manages large-scale optical transport networks in a uniform manner.

iManager MDS

The iManager MDS (MDS for short) is a business-level management


system for transport networks. It assists users to plan and simulate an
optical transport network.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 7

Contents
1.

Introduction to Management Systems

2. Introduction to the T2000 Web LCT

3. Introduction to the T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 8

Contents

Introduction to the
T2000 Web LCT

2.1 Main Characteristics

2.2 Application Scenario

2.3 Installation Guide

2.4 Connecting to NEs

2.5 Configuration Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 9

T2000 Web LCT Main Characteristics


The characteristics of the T2000 Web LCT are
as follows:

Web-based solution

Per-NE configuration and maintenance

Access to a local NE through a LAN/RS


232

Access to a remote NE through DCC

Management of NEs of various types

Concurrent login to a maximum of 32 NEs

Integration with the T2000, T2100 or


third-party management system

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 10

T2000 Web LCT Function


The T2000 Web LCT provides the following NE-layer management
functions:

Service configuration (including PDH and SDH microwave services)


Protection configuration (intermediate frequency protection, SNCP,
LMSP)

Setting and query of the intermediate frequency attributes

Setting and query of the radio frequency attributes

Data services (the 10M/100M fast Ethernet transparent


transmission board EFT4 is supported)

Setting and viewing of alarms and performance data

Communication and security

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 11

Contents
Introduction to the T2000 Web LCT

2.1 Main Characteristics

2.2 Application Scenario

2.3 Installation Guide

2.4 Connecting to NEs

2.5 Configuration Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 12

T2000 Web LCT Application Scenario


Stand-alone

The equipment maintenance personnel installs


the T2000 Web LCT on a PC.

The equipment maintenance personnel


manages local or remote NEs by using the
T2000 Web LCT.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 13

T2000 Web LCT Application Scenario


Integrated

The personnel at the network operations center install the EMS or NMS on a PC.

Install the T2000 Web LCT as a part of the EMS. The NMS need not be installed.

The personnel at the network operations center starts the T2000 Web LCT by
using the EMS or NMS client.

NMS

DCN
EMS

EMS

NE network
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

NE network
Page 14

Contents

Introduction to the T2000 Web


LCT

2.1 Main Characteristics

2.2 Application Scenario

2.3 Installation Guide

2.4 Connecting to NEs

2.5 Configuration Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 15

T2000 Web LCT Installation


Guide
Pre-installation

Configuration requirements

The T2000 Web LCT runs on the Windows operating


system.

Hardware requirements

CPU: Pentium III 700 MHz or higher

RAM: 256 MB (recommended 512 MB or higher)

Monitor: 1024 x 768 resolution

Serial port: RS 232

Ethernet port: 10M/100M

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 16

T2000 Web LCT Installation


Guide
Pre-installation (continued)

Software requirements

Windows XP Professional SP2/Windows 2003


Server Standard SP1

Internet Explorer 6.0 or better

Tomcat 5.0

JDK1.4.2

Servlet 2.3

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 17

T2000 Web LCT Installation


Guide

Prerequisite: Windows XP Professional SP2 or Windows 2003


Server standard SP1 must be installed.

Procedure

Step 1 Uncompress the installation package or Insert the


installation CD, and run the setup.exe file. Click Next.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 18

T2000 Web LCT Installation


Guide
Step 2 Select I accept the terms of the license agreement and

click Next.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 19

T2000 Web LCT Installation


Guide
Step 3 Enter your user name, company name, and

serial number Click Next.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 20

T2000 Web LCT Installation Guide

Step 4 Click Next.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 21

T2000 Web LCT Installation


Guide

Step 5 Click Install and the Setup Status dialog box is displayed.

After the T2000 Web LCT is installed, the Installation Complete dialog
box is displayed.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 22

T2000 Web LCT Installation


Guide

Step 6 Click Finish.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 23

T2000 Web LCT Installation


Guide
Checking the Installation

After you install the T2000 Web LCT, you need to check the
correctness of installation. Check directories and files as follows:

The T2000 Web LCT installation directory.

The installation directory of the jre software.

By default is C:\Web_LCT\jre.

The installation directory of the Tomcat software.

By default is C:\Web_LCT.

By default is C:\Web_LCT\Tomcat .

Check the shortcut icon on desktop. The iManager T2000 Web


LCT group is created in the Windows Program bar.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 24

Contents

Introduction to the T2000


Web LCT

2.1 Main Characteristics

2.2 Application Scenario

2.3 Installation Guide

2.4 Connecting to NEs

2.5 Configuration Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 25

T2000 Web LCT Connecting to


To use the T2000 Web LCT to configure and manage NEs, you need
NEs

to connect the T2000 Web LCT to NEs with an Ethernet cable or a


serial port.

Procedure

By using a network cable


1. Connect a network cable to the computer where the T2000
Web LCT resides.
2. Route the network cable to the equipment side and connect
the RJ-45 connector of the network cable to the network
management interface on the front panel of the equipment.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 26

T2000 Web LCT Connecting to


NEs
Procedure (continued)

By using DCN
1. Use a network cable to connect the computer where the
T2000 Web LCT resides to the DCN.
2. Connect one end of another network cable to the network
management interface on the front panel of the
equipment. Connect another end to the DCN.

By using an RS 232 serial port cable


1. Connect the serial port cable to the computer where the
T2000 Web LCT resides.
2. Route the serial port cable to the equipment side.
Connect the RS 232 connector of the serial port cable to
the RS 232 interface on the front panel of the equipment.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 27

Contents

Introduction to the T2000 Web


LCT

2.1 Main Characteristics

2.2 Application Scenario

2.3 Installation Guide

2.4 Connecting to NEs

2.5 Configuration
Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 28

Contents

Configuration Operations

2.5.1 Logging In to an NE

2.5.2 Modifying the NE ID

2.5.3 Configuring IF Protection

2.5.4 Setting IF Attributes

2.5.5 Setting RF Attributes

2.5.7 Configuring Service

2.5.7 Configuring SNCP Service

2.5.8 Converting service

2.5.9 Alarm

2.5.10 Performance

2.5.11 Communications and


Security

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 29

Web LCT Configuration Logging In to an


NE
Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to
launch the T2000 Web LCT.
Step2 The User Login screen is displayed. Enter the user name and
password. Click Login.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 30

Web LCT Configuration Logging In to an


NE
Create an NE in one of the following two ways.
1. Click NE Search and specify the search criteria. Select the NE to
be added to create a new NE.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 31

Web LCT Configuration Logging In to an


NE
2. Create an NE directly. Click the Add NE and Enter the
information of the NE and create the NE.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 32

Web LCT Configuration Logging In to an


NE

Step 4: In the NE List, select the target NE and click NE Login.Then,


the IE displays the NE Login dialog box.

Step 5:Enter the User Name and the Password. Then, click OK.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 33

Web LCT Configuration Modifying the NE


ID
Step 1 In the NE Explorer, choose Configuration > NE Attribute
from the Function Tree. Click Modify NE ID.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 34

Web LCT Configuration Modifying the NE


ID
Step 2 Enter a new ID and click OK.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 35

Web LCT Configuration Modifying the NE


ID
Step 3 In the NE list, delete the original NE. Create a new NE with
the new ID.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 36

Web LCT Configuration Configuring IF


Protection

The supported IF protection is 1+1 HSB, 1+1 SD, and 1+1 FD.
Create

IF protection

Step 1 In the NE Explorer, choose Configuration > IF 1+1


Protection from the Function Tree.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 37

Web LCT Configuration Configuring IF


Protection
Step 2 Click New and enter the information of the IF protection.
Click OK or Apply.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 38

Web LCT Configuration Configuring IF


Protection

Perform IF protection external switching. The priorities of external


switching commands are as follows: clear, lockout, force, and manual.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 39

Web LCT Configuration Setting IF


Attributes

You can set the following IF attributes by using the T2000 Web LCT:
working mode, link ID, IF port loopback, 2 Mbit/s wayside service,
and ATPC-related information.

In the NE Explorer, select an IF board and choose IF Interface from


the Function Tree.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 40

Web LCT Configuration Setting IF


Attributes
You can enable automatic transmit power control (ATPC), and
adjust the threshold and the ATPC adjustment.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 41

Web LCT Configuration Setting RF


Attributes

By using the T2000 Web LCT, you can query and configure the
following RF attributes: transmit frequency, T/R spacing,
transmitted power, ODU manufacturer information, RF loopback
status, and ODU status.

Frequency attributes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 42

Web LCT Configuration Setting RF


Attributes
Power attributes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 43

Web LCT Configuration Setting RF


Attributes
ODU manufacturer information

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 44

Web LCT Configuration Setting RF


Attributes
In the Advanced Attributes tab, you set ODU status.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 45

Web LCT Configuration Configuring a


Service

This operation is applicable to VC4, VC3, and VC12 services.

Procedure
Step 1 In the NE Explorer, Configuration -> CrossConnection Configuration from the Function Tree.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 46

Web LCT Configuration Configuring a


Service

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 47

Web LCT Configuration Configuring a


Service
Step 2 Click New, enter the information of a service and click OK or
Apply.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 48

Web LCT Configuration Configuring an SNCP


Service

This operation is applicable to VC12, VC3, and VC4 SNCP services.

Procedure
Step 1 In the Cross-Connection Configuration window, click
Create SNCP. Enter the information of an SNCP service.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 49

Web LCT Configuration Configuring an SNCP


Service
Step 2 After you create an SNCP service, the window is divided
into two panes. The upper pane displays the working service and
the lower pane displays the protection service. You can perform
external switching for the working and protection services.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 50

Web LCT Configuration Converting a


Service

The T2000 Web LCT supports the conversion between a normal


service and an SNCP service.

To convert a normal service to an SNCP service, select a normal


service, right-click and choose Convert to SNCP from the shortcut
menu. Enter the source of the service in the protection channel
and click OK.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 51

Web LCT Configuration Converting a


Service

You can convert the working or protection channel of an SNCP service to


a normal service.

To convert a working channel, right-click the service in the working


channel and choose SNCP Working Service Change to Normal
Service from the shortcut menu.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 52

Web LCT Configuration Converting a


Service

To convert a protection channel, right-click the service in the protection


channel and choose SNCP Protection Service Change to Normal
Service from the shortcut menu.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 53

Web LCT Configuration Alarm

By using the T2000 Web LCT, you can view the current and history
alarms, the reporting status of alarms for an NE and boards, and
abnormal events.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 54

Web LCT Configuration


Performance
The T2000 Web LCT supports 15-minute and 24-hour
performance monitoring intervals.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 55

Web LCT Configuration


Performance

You can view the current and history performance data, UAT events,
threshold crossings, and performance monitoring status. You can set
the performance threshold and reset a board registry.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 56

Web LCT Configuration Communications

The RTN 600 uses the OSP NE platform.

You can set multiple protocol stacks, including the OSI, IP,
and HWECC.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 57

Web LCT Configuration Communications

For DCC management, an IF board supports the configuration of


different DCC rates in different working modes.

When the working mode is PDH, the configuration of onebyte DCC (D1-D1) rate is supported.
When the working mode is SDH, the configuration of D1-D3,
D4-D12, D1-D12, and D1-D1 is supported.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 58

Contents
1.

Introduction to Management
Systems

2.

Introduction to T2000 Web LCT

3. Introduction to T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 59

Contents

Introduction to T2000

3.1 Main Characteristics

3.2 Application Scenario

3.3 Configuration
Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 60

T2000 Main Characteristics

The T2000 consists of server and client.

The server is developed based on C++ and the client


is based on Java.

The T2000 manages a maximum of 1000 equivalent


NEs and supports concurrent operations of 32 clients.
T2000 server

T2000 client

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

T2000 client

Page 61

T2000 Main Characteristics

Modular architecture

Open and integrated

High efficiency and reliability

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 62

Contents

Introduction to T2000

3.1 Main Characteristics

3.2 Application Scenario

3.3 Configuration
Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 63

T2000 Application Scenario

Subnet management system (SNMS)

Applicable to small and medium network


management

Provides power NE management functions

Uniformly manage the RTN/SDH/ASON/MSTP/WDM


equipment

Provides the standard northbound interfaces and


supports OSS integration

iManager T2000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 64

Contents

Introduction to T2000

3.1 Main Characteristics

3.2 Application Scenario

3.3 Configuration
Operations

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 65

Contents

Configuration Operations

3.3.1 Microwave link

3.3.2 Alarm

3.3.3 Performance

3.3. 4 Linear MSP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 66

T2000 Configuration Creating a


Microwave Link

The T2000 allows you to create a Microwave link. You can view the
networking on the Main Topology.
Step 1 On the Main Topology, right-click and choose Microwave link
from the shortcut menu. Enter the information of the Microwave
link.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 67

T2000 Configuration Creating a


Microwave Link

Alternatively, click the icon on the toolbar to display the Create


Link window.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 68

T2000 Configuration Creating a Microwave Link


Step 2 Click OK or Apply. The link is displayed as
follows:

When the source and the sink have different working modes, the link status is
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 69

Current Alarm Statistics

An NE reports current alarms to the T2000.


You can filter alarms according to the report
time of alarms.
You can view alarm statistics in each NE.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 70

Customizing Alarm Attributes

You can customize alarm functions, such as alarm


severity, alarm suppression, and alarm reporting.

The T2000 supports a maximum of 16 alarm templates.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 71

Alarm Correlation Analysis and


Suppression
A number of NE alarms

Alarm analysis rule

Root alarm

Characteristics:

Retain the root alarms.

Suppress the non-root alarms.

Customize the analysis rules.

Suppress nonroot alarms

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 72

Customizing Performance Threshold


The T2000 supports customization of a
maximum of 16 performance thresholds.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 73

History Performance Analysis

The T2000 provides graphic history performance data analysis.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 74

T2000 Configuration

The T2000 and T2000 Web LCT are the same in terms of service
configuration, IF protection, IF and RF attributes, and
communications. Refer to the description in the T2000 Web LCT
part.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page 75

Thank You
www.huawei.com
www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Вам также может понравиться